Model EARTH RESISTANCE CLAMP USERS MANUAL EARTH RESISTANCE C L A M P : CAT II. 1mA 20A AL : ~ 600V

Similar documents
Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

User s Manual. Ground Resistance Clamp On Tester MODEL

Digital Clamp Meter Model: &

OPERATOR S INSTRUCTION MANUAL

AC/DC CLAMP METER USER S MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Model UT233 OPERATING MANUAL

UT232. Operating Manual. Digital Power Clamp Meter

ET-3888 True RMS Clamp Meter. User Manual

8PK-ST1520 Digital Earth Resistance Tester

User Manual Digital Clamp Multimeter. model no.: MSR-C600

MS2030 CAT III 600 V A V AUTO RS232

EARTH RESISTANCE TESTER

Multifunction Digital

Pen-type DIGITAL MULTITESTER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

3B SCIENTIFIC PHYSICS

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

Contents. 1. Safety Description Specifications Operation Instructions Battery Replacement...20.

1. Multi-Point Grounding System Limited Point Grounding System Single-Point Grounding System IX. Bill of Loading X.

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

True RMS Digital Multimeter Model:

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

AMM-1022 Digital Multimeter USER`S MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Digital Multimeter, Pen Type

MANUAL PCE-UT232

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DVM1190 DIGITAL MULTIMETER

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Model UT511 OPERATING MANUAL

MW3105 DIGITAL CLAMP MULTIMETER

CONTENTS MS2033A. 1.Introduction Safety Information...01

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

MS2109A AC/DC Clamp Meter. User Manual. Contents

KMD-S04 Multímetro de bolsillo

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

NOTE: Fully read and understand this manual before using this Digital Multimeter.

OPERATOR S INSTRUCTION MANUAL

Clamp-On Ground Resistance Tester Model 3705

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Model: &

Mini Clamp Meter Model:

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER AUTORANGING

MS2302. Digital Earth Resistance Tester

DIGITAL CLAMP METER Use s Manual

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

UT231. Operating Manual. Digital Power Clamp Meter P/N:

User Manual 4 wire Earth Resistance Tester Model GRT300

Digital Clamp Meter (TRMS) Model : 2727

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Instruction Manual for Digital Grounding Resistance Meter

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

The Meter Structure The Figure 2-1 shows the Meter structure.

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Micro-Ohmmeter Model UM200

UT207/208. Digital Clamp Multimeter P/N:

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Model UT201/202: OPERATING MANUAL. Table of Contents

Model : OPERATING MANUAL Table of Contents (1)

Clamp-On Ground Resistance Tester Models 3711 and 3731 USER MANUAL

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

ATK Clamp Meter

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

VC835 DIGTAL MULTIMETER Operation Manual

Model UT10A: OPERATING MANUAL Table of Contents (1)

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

CLAMP-ON METER 670. User Manual

User Manual Digital Multimeter

USER MANUAL Clamp Meters ACM-2353

Not for Reproduction

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DCM730. Digital Clamp Meter User s Manual

MS8223A. CAT.IIi 600 V

DM-46 Instruction Manual

Model DIGITAL MULTIMETER

AX-C Introduction. 2. Safety Information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Transcription:

Model 57276 EARTH RESISTANCE CLAMP USERS MANUAL EARTH RESISTANCE C L A M P A A : 600V : 0.01 1200 CAT II AL : 1 100 1mA 20A MEM : 1 99

CONTENTS WARNING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 MAINTENANCE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 INTRODUCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 FRATURES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 SUMMARY OF FUNCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 LAYOUT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 LCD DISPLAY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 OPERATION ON/OFF OPERATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 EARTH RESISTANCE MEASUREMENT - - - - - - - - - - - - - - - - - - - - 7 CURRENT MEASUREMENT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10 HOLD BUTTON - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11 ALARM OPERATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11 MEMORY FUNCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12 SPECIAL FUNCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 SPECIFICATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 FEATURES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 ACCESSORY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16 CHANGING THE BATTERIES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16 CHARGE THE BATTERIES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17 APPLICATION FIELD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18

WARNING * Before measuring, note that the metal objects or the conductors that connect with the electric equipment are dangerous, as well as the earth system. So when you test the electric equipment, you must especially pay attention to safety. * The warning letter that is in the back of your instrument reminds you of the values that must not be exceeded, the measurement ranges, and briefly, the operation of the clamp. * Do not exceed the permissible overloads of loop current. * Before switching the instrument on, you must press the trigger several times to ensure the clamp is closing correctly. * When switching on and the clamp it is auto-calibrating, do not open the clamp or hook the clamp jaw around any conductor. READ THE INSTRUCTIONS BEFORE USING THE INSTRUMENT MAINTENANCE * Keep the surfaces of the clamp jaw clean, any dirt may cause malfunction of the clamp. * Use the soft damp cloth to clean the clamp jaw faces, do not use abrasives, solvents, or alcohol. * Avoid any shock, especially the clamp jaw faces. * Avoid the immediate proximity of metallic masses. * After each measurement, press the HOLD button to reduce consumption of the batteries. * Remove the batteries from the instrument in case of prolonged non-use. 1

INTRODUCTION Modern industrial electronic equipment is in quick development. A good Earth ground is becoming an efficient system to prevent from interference and thunderbolt. A safe and quick earth tester is most needed. The Earth resistance clamp is a breakthrough from traditional testers. Neither the supplementary earth leads nor the break earth equipment is necessary. Ground resistance results can be safely and quickly obtained only by clamping the ground line. Current testing is also provided. This high sensitivity clamp meter can measure the leakage current to 1mA, neutral current to 20A RMS. It is especially important for testing ground circuit with strong interference and ripple that will influence the electrical quality. In addition to industrial electronic equipment, it is also widely used in the field of electric power distribution, telecommunication and architectural ground. FEATURES 0.01Ωhigh accuracy for low resistance measurement 0.001Ωhigh resolution Record 99 resistance measurement values With alarm function of resistance limit, set alarm threshold in 1Ω to 100Ω Measure leakage current and neutral current 1mA20A 45mm 32mm large jaws of exactitude measurement probe Digital measurement, autorange,easy operation Double insulation, strengthen the interference resistance Untouched measurement,ensure the safety Time per measurement : 1 second Current overload display : >20A RMS, display OL 2

SUMMARY OF FUNCTION FUNCTION BUTTON ON/OFF/EXIT SET MODE A MEASUREMENT/ ALARM VALUE INCREASE/ RECORD NUMBER SELECT Ω MEASUREMENT/ ALARM VALUE MINISH / RECORD NUMBER SELECT HOLD DISPLAY SELECT ALARM MODE SELECT /SET MEMORY MODE A Ω HOLD AL MEM SWITCH BUZZER ON/OFF +Ω SET ALARM VALUE AUTO POWER OFF FUNCTION SET READ SAVED MEASUREMENT VALUE RESET MEMORY TO ZERO +AL +HOLD +MEM HOLD+MEM LAYOUT 1. Clamp jaw 2. Trigger 3. MEM Button 4. Button(ON/OFF BUTTON ) 5. LCD Display 6. AL Button 7. Ω Button 8. A Button 9. HOLD Button 3

1 2 3 4 EARTH RESISTANCE P A M C L A 9 8 7 5 6 A : 1mA 20A 600V : 0.01 1200 CAT II AL : 1 100 MEM : 1 99 LCD DISPLAY (Note: when switch is on, the clamp performs a rapid auto-test of the whole display. All the symbols on the LCD are displayed for this short time.) 4

1 2 3 4 5 20 19 18 6 7 8 9 17 16 15 14 13 12 11 10 1. Buzzer ON symbol 2. HOLD symbol : holds the last measurement 3. Interference Symbol: shows that the current in the loop is disturbed such that the resistance measurement value is not guaranteed. 4. Clamp symbol: shows that the clamp is closed incorrectly, cannot measure. 5. Wait symbol: shows that the instrument is auto-calibrating 6. Current measurement unit 7. Resistance measurement unit 8. Decimal points 9. Percent sign of the batteries actual service life 10. Alarm threshold value of resistance unit 11. Digital display of the battery actual service life or Alarm threshold value 5

12. High Alarm symbol 13. Low Alarm symbol 14. Alarm mode symbol 15. Low voltage indication symbol 16. Auto Power Off symbol 17. Record number symbol 18. Read memory mode symbol 19. save in memory mode symbol 20. 4 digit LCD digital display OPERATION 一 ON/OFF OPERATION button switches ON/OFF. Press button so the clamp switch is on, Press the button for 2 seconds, the instrument switches off. As soon as it switches on, the earth resistance clamp begins to auto-calibrate to obtain better resolution. When it is calibrating, the instrument will count from CAL 9 to CAL 0. The user must wait for the clamp to complete calibration. Do not open the clamp or hook the clamp jaw around the conductor or the object to be measured during the calibration. After the calibration is completed, the instrument returns to the measurement mode when last switch off. If the instrument is in resistance measurement mode when switch off, the LCD will display the primary resistance measured value. 6

二 EARTH RESISTANCE MEASUREMENT 1. After switching on, the instrument is automatically in measurement current mode, you can press the Ω button to configure for resistance measurement mode. 2. Hook the clamp jaw around earth leads or electrode to be tested. 3. If symbol - - - and symbol are shown on the display, it indicates that the clamp is closed incompletely. You must press the trigger of the instrument several times to close the clamp jaw correctly. After the symbol disappears from the display, meter is in the normal measurement mode. 4. Read the measurement value on the display. 5. When the display shows the NOISE symbol, it indicates that there is an interference current in the loop, the resistance measurement may be innaccurate. 6. Schematic of measurement Buzzer ON A loop earth resistance of 36.2Ω The batteries service life is 87% 7

Buzzer ON A loop earth resistance of 68.7Ω The earth resistance value is above the high alarm threshold 50Ω, a beep is emitted Buzzer ON A loop earth resistance of 0.5Ω The earth resistance value is less than the low alarm threshold value 8Ω, a beep is emitted 8

Buzzer ON A loop earth resistance of 19.6Ω The earth resistance value is less than the high alarm threshold value 30Ω, no beep is emitted 6 recorded values in the memory Buzzer ON Read the 22nd recorded measurement, the loop earth resistance of 176.4Ω The low alarm threshold of earth resistance set at 15Ω Buzzer ON A interfered current is in the loop resistance, the current measured resistance is 55.2Ω, the value is not guaranteed The batteries service life is 86% 9

Buzzer ON A loop earth resistance of 93.7Ω The batteries service life is 18% and less than 20%.The display shows the low voltage indication Auto Power Off function is valid 55 recorded values in the memory The clamp jaw is closed incorrectly, --- is displayed The batteries service life is 90% 三 CURRENT MEASUREMENT 1. Press the A button on the instrument. 2. The display shows the current unit A or ma, the instrument is in 10

current measurement mode. You can measure current of the conductor. 3. Read the measurement value on the display. 4. If the display shows symbol OL, it indicates the measured value exceeds the measurement range. 四 HOLD BUTTON Press the HOLD button to lock display of the current measured value and the last measurement on measurement mode. 五 ALARM OPERATION 1. On resistance measurement, press the AL button, AL symbol and the value of the alarm threshold is displayed. 2. According to the measurement demand, you can press the AL button time after time to select one of three alarm modes: ---- LOW ALARM MODE: this signals measurement below the alarm threshold, a continuous beep at low frequency. The symbol is displayed. ---- HIGH ALARM MODE: this signals measurement above the alarm 11

threshold, a continuous beep at high frequency. The symbol is displayed. ---- NO ALARM MODE: signals measurement is not confined in alarm threshold. 3. Set the alarm threshold The earth resistance clamps initial Alarm threshold value is high alarm threshold of 20Ω. In resistance measurement mode, press the +Al to set in Alarm threshold value setting mode, then AL symbol and the Alarm threshold value are displayed; press A or Ω button, you can increase or decrease the Alarm threshold value, the Alarm threshold is from 1 to 100Ω inclusive. After switching off the threshold value is not changed. Setting Alarm threshold value completed, you can press AL button to select one of the three Alarm modes: HIGHT ALARM MODE, LOW ALARM MODE, NO ALARM MODE. When the selection is completed, you can press the button to exit Alarm threshold value setting mode. 六 MEMORY FUNCTION 1. Clear memory Press the HOLD+MEM for 3 seconds, then the CLR symbol is shown on the display. At a beep, the memory is cleared. The instrument returns to measurement mode automatically. 2. Save measured value When pressing the MEM button,the MEM symbol is displayed; press this button for 2 seconds to save the current measured value in memory. 12

The number of record goes up by 1 automatically and is shown on the display, when the number of the record is 99, if MEM button is pressed again at this time, a beep is emitted and the instrument prohibits saving the measurement value. When the batteries service life is less than 20%, a beep warns that the saving measured value is prohibited. 3. Read the saving measurements Press the +MEM for 1 second, then the instrument is in the read memory mode, the MR and HOLD symbol are displayed, the number of the record and the measured value are shown at one time. To display previous record or subsequent record in the memory press A button or Ω button. You can press the button to exit read the record mode to return resistance measurement mode. 七 SPECIAL FUNCTION 1.Press +Ω button, & the buzzer symbol disappears from the display, the buzzer & beep function is switched off by pressing button and Alarm function is invalid; press the +Ω to switch to turn on the buzzer again. 2.ON/OFF Auto Power Off function Press +HOLD button, the LCD displays P symbol, the Auto Power Off function switch is on. After no operation for 5 minutes, the instrument switches off automatically. Press +HOLD again, then the P symbol disappears from the display, the Auto Power Off function switch is off. To switch off the instrument press the button for 2 seconds. 13

3. Symbol When the battery service life is less than 20%,the symbol is continually displayed, the clamp cannot save the measured value in memory in this case. When the batteries service life is less than 15%, prompt beeps is continually emitted. After 10 beeps is emitted, the instrument switch turns off automatically. 4.NOISE Symbol NOISE appears on the display indicates that an interference current of testing earth resistance is too high, the resistance measurement is not accurate. 5. Symbol This symbol indicates that the clamp is closed incorrectly and cannot make a measurement. 6.WAIT Symbol This symbol is shown on the display when the instrument switch is on and begins to auto-calibrate, it is from CAL 9 to CAL 1 to calibration count. 7.OL Symbol Measured resistance value exceeds 1200Ω or measured current value exceeds 20A, this symbol is shown on the display. 14

SPECIFICATION RANGE ACCURACY RESOLUTION 0.01Ω0.999Ω ±(1.5%+0.01Ω) 0.001Ω 1Ω9.99Ω ±(1.5%+0.1Ω) 0.01Ω RESISTANCE 10Ω99.9Ω ±(2.0%+0.3Ω) 0.1Ω 100Ω199.9Ω ±(3.0%+1Ω) 1Ω 200Ω400Ω ±(6.0%+5Ω) 5Ω 400Ω500Ω ±(10%+10Ω) 10Ω 500Ω1200Ω approx. 20% 20Ω 100mA ±(2.5%+1mA) 0.1mA 300mA ±(2.5%+2mA) 0.3mA CURRENT 1A ±(2.5%+0.003A) 0.001A 3A ±(2.5%+0.01A) 0.003A 10A ±(2.5%+0.03A) 0.01A 20A ±(2.5%+0.05A) 0.03A TESTING CONDITIONS: Temperature 23 ±3 Humidity 50%RH±10% Battery Voltage >7V

External magnetic field <40A/m External electric field <1 V/m Testing frequency of current 45Hz65Hz FEATURES Test voltage : 3700V Electric clearance : 6.5mm ( IEC1010 double insulation CATⅡ 600V ) Electric shock : IEC1010-1 Limiting overload : 20A RMS current Average consumption : approx. 50mA Range : autorange Display : LCD 4 digits, 9999 Low voltage indication : display symbol Power supply : Ni-MH 600mAh 1.2V 6 AAA Average service life: recharge 500 times, per time approx. 1012 hours for continued use Time per measurement : 1 SECOND Operating temperature : -10 50 (14 to 122 ) Storage temperature : -20 60 (-4 to 140 ) Conductor size : ф32mm OR 45mm 32mm Dimensions : 54mm 104mm 276mm Weight : approximate 1050g (including batteries)

ACCESSORIES Calibration loop of resistance (0.01Ω) Calibration loop of resistance (1Ω) Calibration loop of resistance (10Ω) 1 piece 1 piece 1 piece 1.2V Batteries ( Ni-MH ) 6 pcs Users manual Battery charger Carry case 1 piece 1 pcs 1 piece CHANGING THE BATTERIES When the display appears the symbol, the batteries are weak, they must be changed. Please follow these steps: 16

1.Switch off the meter 2.Unscrew the screw on the battery cover 3.Remove the cover 4.Take the battery box out of the instrument 5.Replace with new batteries of the same type 7.Reinstall the battery box 8.Replace the battery cover 9.Reinstall the screw batteries battery box battery cover CHARGE THE BATTERIES Refer to the operation manual on the battery charger. 17

A : 0.01 1200 CAT II AL : 1 100 MEM : 1 99 C L EARTH RESISTANCE APPLICATION FIELD EARTH RESISTANCE CLAMP is designed for testing earth resistance of any loop system, for example not only earth resistance of electric power transportation conductors and communication circuitry, but also earth resistance of electric equipment and lightning arresters can be tested. When there is an interference current in the grounding loop, the accuracy of resistance measurement is affected, the interference current can be tested by the earth resistance clamp. PRINCIPLE OF MEARSUREMENT : R x : R 1 R 2 R n : R earth : R guard wire : earth resistance value to be tested multiple parallel earth resistance normally be regard as 0Ω normally be regard as 0Ω R Loop =R x +R earth +(R 1 // R 2 // R n )+R guard wire When R 1 //R 2 // R n <<R x, then R Loop =R x I guard wire A : 1mA 30A 600V A M P E Rx R1 R2 Rn Rearth 18

A A : 1mA 30A 600V : 0.01 1200 CAT II AL : 1 100 MEM : 1 99 EARTH RESISTANCE C L A M P 一 TESTING EARTH RESISTANCE OF ELECTRIC POWER 1.TESTING EARTH RESISTANCE OF DISTRIBUTION CIRCUITRY Usually most electrodes of neutral wire are connected in parallel for three-phase, four-wire systems. The resistance is very low, so you only hook the clamp around earth conductor to be measured to test the distribution circuitry. Other earth electrodes become supplementary electrode naturally. 2.TESTING TRANSMIT ELECTRICITY CIRCUITRY(SUBSTATION TOWER) Transmit electricity circuitry works by substation tower. The earth system of tower connects with lightning rod of tower, so tower that is not tested becomes very well supplementary electrode. This is a great breakthrough from traditional testers which threw into supplementary electrode on the road. 19

1mA 30A : 0.01 1200 CAT II AL : 1 100 MEM : 1 99 A EARTH RESISTANCE C L A M P EARTH RESISTANCE C L A MEM : EARTH RESISTANCE C L A M P A A : 1mA 30A 600V : 0.01 1200 CAT II AL : 1 100 MEM : 1 99 1mA 30A : 0.01 1200 CAT II AL : 1 100 MEM : 1 99 A C L A M P EARTH RESISTANCE 二 ELECTRIC POWER MAINTAIN OF THE FACTORY Usually the factory is divided into several different earth network fields, so you can test earth resistance in this way: TESTING CONDUCTOR R3 R2 A : 600V EARTH RESISTANCE CLAMP A : 600V R1 EARTH NEWWORK OF OIL TROUGH 三 TESTING EARTH RESISTANCE OF TELECOMMUNICATION INSULATES THE CABLES To test the shield lay which avoids circuit interference, the earth resistance clamp can measure earth resistance directly and easily. WIRE OF CABLE SCREEN LAY WIRE EARTH CONDUCTOR EARTH CONDUCTOR A M P A : 1mA 30A 600V : 0.01 1200 CAT II AL : 1 100 1 99 EARTH RESISTANCE CLAMP MULTIPLE EARTH IN PARALLEL BE SUPPLEMENTARY ELECTRODE 20

EARTH RESISTANCE A M P C L A MEM : 1 99 四 APPLICATION OF FARADAY-CAGE PROTECT SYSTEM Use FARADAY-CAGE to avoid instrument and equipment static interference, so it is very important that we can control earth resistance. If the user wants to test the earth resistance value of each electrode, it is not necessary to set the supplementary electrode, the user can test referring to the follow diagram. If the user wants to test integrate earth resistance of all FARADAY-CAGE, you can make the measurements with the low value earth electrode being the supplementary electrode. EARTH CONDUCTOR A : 1mA 30A 600V : 0.01 1200 CAT II AL :1 100 EARTH RESISTANCE CLAMP MULTIPLE EARTH IN PARALLEL BE SUPPLEMENTARY ELECTRODE 五 TESTING EARTH RESISTANCE OF OIL TROUGH The oil trough often has over two earth electrodes. Note: When the oil trough is itself an earth conductor, it very often becomes a short circuit; the user can make the measurement with the other oil trough being the supplementary electrode. 21

A : 1mA 30A 600V : 0.01 1200 CAT II AL :1 100 MEM : 1 99 A EARTH RESISTANCE C L A M P OIL TROUGH MULTIPLE EARTH IN PARALLEL BE SUPPLEMENTARY ELECTRODE EARTH RESISTANCE CLAMP EARTH CONDUCTOR 六 TESTING EARTH RESISTANCE OF LIGHTNING ROD When the lightning rod only uses one earth conductor and earth electrode, you can apply the another earth object as being the supplementary electrode to form a loop. EARTH CONDUCTOR EARTH RESISTANCE CLAMP When lightning rod has over two earth conductors, you can make measurement as the following diagram. The resistive value measured in this way is a sum for local earth in series and resistance of earth conductors. (when resistance of earth conductors is very low, it can be ignored.) 22

A WAIT : 0.01 1200 CAT II AL : 1 100 MEM : 1 99 EARTH RESISTANCE C L P A M A A 1mA 30A MEM : 1 99 EARTH RESISTANCE CLAMP A : 1mA 30A 600V C L A M P 七 APPLICATION OF GAS STATION For gas stations it is necessary to test earth resistance to prevent static electricity. Apply earth electrode of oil trough to the supplementary electrode to test earth resistance of gas station. The tested result sum of earth resistance of the gas station and earth resistance of oil trough in series is noticeable. EARTH NETWORK OF GAS STATION EARTH CONDUCTOR NETWORK OF OIL TROUGH EARTH RESISTANCE : 600V : 0.01 1200 CAT II AL: 1 100 EARTH RESISTANCE CLAMP 23