Level control drain valve tuning. Walter Bischoff PE Brunswick Nuclear Plant

Similar documents
Experiment 9. PID Controller

Different Controller Terms

International Journal of Research in Advent Technology Available Online at:

Getting the Best Performance from Challenging Control Loops

Procidia Control Solutions Dead Time Compensation

CHBE320 LECTURE XI CONTROLLER DESIGN AND PID CONTOLLER TUNING. Professor Dae Ryook Yang

Controller Algorithms and Tuning

The Discussion of this exercise covers the following points: Angular position control block diagram and fundamentals. Power amplifier 0.

Paul Schafbuch. Senior Research Engineer Fisher Controls International, Inc.

CHAPTER 2 PID CONTROLLER BASED CLOSED LOOP CONTROL OF DC DRIVE

-binary sensors and actuators (such as an on/off controller) are generally more reliable and less expensive

Introduction To Temperature Controllers

CHAPTER 4 PID CONTROLLER BASED SPEED CONTROL OF THREE PHASE INDUCTION MOTOR

Closed-Loop Position Control, Proportional Mode

PID Control Technical Notes

MM7 Practical Issues Using PID Controllers

LESSON 2: ELECTRONIC CONTROL

Control Theory. This course will examine the control functions found in HVAC systems and explain the different applications where they are applied.

PID control. since Similarly, modern industrial

Understanding PID Control

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

PID. What is PID and how does it work? Auto tuning PID with the 5400 Controller. Visit our website at:

Application Note. Renu Electronics Private Limited. PID Instruction In IEC. Page 1

Configuration Example of Temperature Control

Class 5. Competency Exam Round 1. The Process Designer s Process. Process Control Preliminaries. On/Off Control The Simplest Controller

PROCESS DYNAMICS AND CONTROL

Process Control Laboratory Using Honeywell PlantScape

Neural Network Predictive Controller for Pressure Control

F. Greg Shinskey. "PID Control." Copyright 2000 CRC Press LLC. <

Instrumentation and Process Control. Process Control. Pressure, Flow, and Level. Courseware Sample F0

Introduction To Temperature Controllers

1. Consider the closed loop system shown in the figure below. Select the appropriate option to implement the system shown in dotted lines using

STANDARD TUNING PROCEDURE AND THE BECK DRIVE: A COMPARATIVE OVERVIEW AND GUIDE

Relay Based Auto Tuner for Calibration of SCR Pump Controller Parameters in Diesel after Treatment Systems

Servo Tuning Tutorial

GL101B Intelligent Temperature Controller User s Guide

PROCESS DYNAMICS AND CONTROL

Optimal Control System Design

Module 08 Controller Designs: Compensators and PIDs

GL102 Intelligent Temperature Controller User s Guide

InstrumentationTools.com

Gain From Using One of Process Control's Emerging Tools: Power Spectrum

ChE 4162 Control Laboratory Methodologies Fall Control Laboratory Methodologies

VOLTAGE STABILITY OF THE NORDIC TEST SYSTEM

TEMPERATURE PROCESS CONTROL MANUAL. Penn State Chemical Engineering

6.4 Adjusting PID Manually

ChE 436 Lab Project 1 Armfield Level Control

Position Control of DC Motor by Compensating Strategies

Proportional pressure controller

Design of Self-Tuning Fuzzy PI controller in LABVIEW for Control of a Real Time Process

Find, read or write documentation which describes work of the control loop: Process Control Philosophy. Where the next information can be found:

PROCESS CONTROL DIAGNOSTICS. F. Greg Shinskey Process Control Consultant North Sandwich, NH 03259

PID Tuner (ver. 1.0)

Comparative Study of PID Controller tuning methods using ASPEN HYSYS

Fundamentals of Servo Motion Control

Closed Loop Control System. Controllers. Analog Controller. Prof. Dr. M. Zahurul Haq

Design of Model Based PID Controller Tuning for Pressure Process

STABILITY IMPROVEMENT OF POWER SYSTEM BY USING PSS WITH PID AVR CONTROLLER IN THE HIGH DAM POWER STATION ASWAN EGYPT

6.9 Jump frequency - Avoiding frequency resonance

Closed-Loop Speed Control, Proportional-Plus-Integral-Plus-Derivative Mode

Laboratory PID Tuning Based On Frequency Response Analysis. 2. be able to evaluate system performance for empirical tuning method;

SxWEB PID algorithm experimental tuning

Logic Developer Process Edition Function Blocks

Nonlinear Control Lecture

When you configure a PID loop in iocontrol, choose one of the following algorithms: Velocity ISA Parallel Interacting

PALO VERDE NUCLEAR GENERATING STATION

Simulation of process identification and controller tuning for flow control system

PROCESS CONTROL LAB. Lab In charge COURSE OBJECTIVES

Figure 1: Unity Feedback System. The transfer function of the PID controller looks like the following:

Performance Analysis of Conventional Controllers for Automatic Voltage Regulator (AVR)

Application Note CTAN #287

Compensation of Dead Time in PID Controllers

Servo Closed Loop Speed Control Transient Characteristics and Disturbances

The PID controller. Summary. Introduction to Control Systems

EVALUATION ALGORITHM- BASED ON PID CONTROLLER DESIGN FOR THE UNSTABLE SYSTEMS

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2844 PID CONTROLLER WITH FEED FORWARD COMPENSATION

QuickBuilder PID Reference

Determining the Dynamic Characteristics of a Process

HPVFP High Performance Full Function Vector Frequency Inverter

CONTROLLER TUNING FOR NONLINEAR HOPPER PROCESS TANK A REAL TIME ANALYSIS

Auto-tuning of PID Controller for the Cases Given by Forbes Marshall

CSE 3215 Embedded Systems Laboratory Lab 5 Digital Control System

Determining the Dynamic Characteristics of a Process

Tuning interacting PID loops. The end of an era for the trial and error approach

Modified ultimate cycle method relay auto-tuning

Design of an Intelligent Pressure Control System Based on the Fuzzy Self-tuning PID Controller

Application sheet for Green 300 series controllers. Title. Purpose. Application Controller Loop Configuration: Wiring: Explanation :

COMPARISON OF TUNING METHODS OF PID CONTROLLER USING VARIOUS TUNING TECHNIQUES WITH GENETIC ALGORITHM

SECTION 6: ROOT LOCUS DESIGN

CHAPTER 4 AN EFFICIENT ANFIS BASED SELF TUNING OF PI CONTROLLER FOR CURRENT HARMONIC MITIGATION

PYKC 7 March 2019 EA2.3 Electronics 2 Lecture 18-1

AN EXPERIMENTAL INVESTIGATION OF THE PERFORMANCE OF A PID CONTROLLED VOLTAGE STABILIZER

TI25 - Pre-Instructional Survey

6545(Print), ISSN (Online) Volume 4, Issue 1, January- February (2013), IAEME & TECHNOLOGY (IJEET)

BIDIRECTIONAL SOFT-SWITCHING SERIES AC-LINK INVERTER WITH PI CONTROLLER

A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators Under Test Contribute to Whole System Stability

12. ELECTRONICS & INSTRUMENTATION FOR TEMPERATURE

Relay Feedback based PID Controller for Nonlinear Process

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental

Proportional pressure controller

Transcription:

Level control drain valve tuning Walter Bischoff PE Brunswick Nuclear Plant

Tuning Introduction Why is it important PI and PID controllers have been accepted throughout process design and all forms of controllers. Everyone has a PI and/or PID controllers in their station. PI and PID controllers are everywhere in your station some common areas include: FWHs level controllers (drains) Rx level control (SULCV) Drain tanks Tuning is an art and often hard to be a precise science EPRI Improper tuning can result in system instability in response to transients, loss of efficiency, Rx level oscillations. For a longer duration, improper tuning will result in unusual equipment degradation rates 2

Tuning basics Set Point (SP), Process Variable (PV), Output (OP) Controller: Generates a signal (output) in response to a process error detected by the feedback loop. The most common type is a PI (Proportional and Integral) Error (e): Difference between Set Point and Process Variable Proportional Response (P): The proportional response is a control response in which there is a continuous linear relationship between the output and the input. Proportional response can be obtained by multiplying the error (e) by the process Gain (K c ). Proportional Band (PB%): (Do not confuse with Gain or Proportional Term) Measured as a percent with respect to gain inverse x 100 PB = 100 / K c OR K c = 100 / PB Large gain = Large response, Large PB = Small response P out = K c x (e) * (t) For an error with a magnitude of 10 and a controller gain of 5 the response would be 50. 3

Tuning basics Gain comparison This simulation lacks offset 4

Tuning basics Integral Response (I): Intended to eliminate offset. Integral sums up the error over time. When (e) = 0 controller output is likely not equal to 0. Units may be in resets/min OR minutes / reset. Response is based on a rate of change Gain alone is difficult to tune to. Excessive gain will result in overshoot, insufficient gain will result in large offset from PV and SP. Hysteresis: Some devices will yield a different PV for the same OP depending on whether the OP went up or down to get there. A valve might allow 25 GPM through after moving from 20% to 30%, but 30 GPM after moving from 40% to 30% (too low of gain or no integral) Offset: difference between set point and process variable. Tank with drain valve (P) Tank with inlet and outlet flow (I) 5

Tuning basics Integral comparison Comparison of what an integral and proportional bands 6

Tuning basics After inducing an upset, the PV is approaches the SP. Proportional and Integral react in opposite directions. Allows PV of a well tuned loop to approach the SP without excessively overshooting or undershooting. In a typical reverse-acting loop, the proportional will try to lower the OP as the PV rises toward the SP. The integral response will raise the OP because PV is below SP. As the PV gets closer to the SP, integral action decreases resulting in the PV smoothly decelerating into the SP. 7

BNP OE event discussion Post EPU and satisfactory performance Series of inputs and outputs from the loop The loops is normally operated with 3 condensate pumps In March 2015 B222R1 refueling outage, Condensate Margin project was implemented. Allows the station allowed to transition from 3 to 2 condensate pump operation. 8

9

Comparison of Unit 1 (2 pumps) and Unit 2 (3 pumps) CBP discharge header Plot-0 350 350 340 \\HST_BNP\U1CODL072 285.77 PSIG \\HST_BNP\U2CODL072 313.53 PSIG 330 320 This simulation lacks offset 310 300 290 280 270 260 250 250 5/21/2015 6:01:39 AM 24.00 hours U1 CBP Disch Hdr Press U2 CBP Disch Hdr Press 5/22/2015 6:01:39 AM 10

Transitioning from 3 to 2 Cond pump operation Irregularities observed On 5/26/15 at 0954 Operations transitioned from three to two condensate pump operation. After securing the third condensate pump, system pressure dropped and system oscillations were observed. This shift in performance and system pressure oscillations have been present since securing the 3 rd condensate pump and have not deviated. Booster pump discharge header pressure dropped expectedly from 320 to 260 psig. Unexpected 30-40 psi CBP pressure oscillations and HDD level oscillations 44 to 52 inches. Normal level is ~48 inches +/- 0.5 inches. Concern over opening HDD backup dump valve, HDD pump trip, CBP auto start, RFP suction pressure alarms. Operations started the 3 rd condensate pump. Oscillations stopped and pressures returned to normal. 11

Comparison of Unit 1 and Unit 2 CBP discharge header in 2 pump operation Plot-0 320 350 310 \\HST_BNP\U1CODL072 292.33 PSIG \\HST_BNP\U2CODL072 286.79 PSIG 300 290 This simulation lacks offset 280 270 260 250 240 230 220 250 5/26/2015 1:56:00 PM 24.00 hours U1 CBP Disch Hdr Press U2 CBP Disch Hdr Press 5/27/2015 1:56:00 PM 12

Tuning basics 13

Heater drain pump performance Single controller 2-HD-LC-91 receives input from the HDD tank level element. The controller output goes to 3 individual positioners and valve actuators. The controller output began at 67.5% output and dropped 4% and quickly recovered by 2% output. The output continued to decline until output was 52.5%. Overall, there was a 15% decline in output with sawtooth patterns. Once the 3rd condensate pump was restored to service, the controller output only oscillated between 54 to 57% in a stable sinusoidal. In two condensate pump operation, the HDD control valve position was observed at approximately 27% open. In three condensate pump operation, the HDD control valve position was observed at approximately 47% open. Known fact, the HDD discharge valves are oversized and are expected to operated more closed than open. 14

Corrective Actions Performed in 2010 In 2010 a new valve trim was installed with quick opening characteristics. Tuning was performed for 3 HDD pumps. Outside contractor requested to perform evaluation and provide tuning characteristics. Controller tuning parameters as-left settings 3.4 Gain and 1.55 min/reset. Pressure oscillations were normal 10-15 psig (as seen in the first graph) Satisfactory performance observed. 15

Investigation Performed in 2015 Compared positioner responses between A and B HDP discharge valve positioners (equipped with feedback arm). Dissimilar outputs and valve position indicates degradation in the positioner or valve. Similar responses in output and feedback observed Confirmed valves were further closed Swapped from A and B HDPs to A and C HDPs to assess the performance in the C and B loops and determine system sensitivity. No change in performance obseved Observed all other inputs and extractions from the loop to/from external reservoir or loop. Observed internal extractions and return lines such as the FWHs and RFP speed controls. There was NO apparent cause relating to equipment damage or externally induced. 16

Former and new valve curve with new trim Post-2010 valve curve Pre-2010 valve curve 17

Corrective Actions Performed in 2015 The new valve trim was changed to a quick opening trim. Throttling valves operate as a steady state, steady flow device. The entering and exiting mass flow rates are the same; i.e. flow is continuous, and the Continuity Equation is applicable 18

Post Tuning results Plot-0 320 350 310 \\HST_BNP\U1CODL072 279.92 PSIG \\HST_BNP\U2CODL072 290.01 PSIG 300 290 This simulation lacks offset 280 270 260 250 240 230 220 250 6/15/2015 1:56:00 PM 24.00 hours U1 CBP Disch Hdr Press U2 CBP Disch Hdr Press 6/16/2015 1:56:00 PM 19

Closer look at finding tuning issues Component changes Make sure your EC package contains tuning evaluation and basis. Tuning should only be performed ONLY when all other plausible failure modes have been ruled out. Maybe you have a latent failure mode? Following a new plant mod or change operations. Did you: Install a new component such as a valve? Transition from a 2(3) pump operation to 3(2) pump operation? Implement EPU? ANYTHING that may affect flowrates Or maybe no one has ever noticed it 20

21

How to tune Requires access to adequate trending parameters especially Set Point, Controller Output, and Process Variable. Most controllers start with a gain of 1.0 (PB 100%) and a reset of 1.0 rpm. Tuning should be performed with a simulator or when there are no margin concerns such as auto pump starts, trips, and no impact on reactivity. Approximation: Loops where the PV changes quickly due to a change in Output (flow, or pressure or level in vessels with fast turnover) should have low Gain (Higher PB) perhaps 0.2 (20%) and higher reset (1.5 10 rpm). Loops where the PV changes slowly, or changes its direction of movement due to change in Output (temperature and level in vessels with slow turnover) typically need high gain (3 100) and low reset (0.05 0.3). 22

How to tune Several approaches. However it is your choice of what method you use. All have advantages and disadvantages. Tuning methods include: Ziegler-Nichols Method Trial and error Cohen-Coon method Process Reaction Curve Quarter wave dampening (preferred) 23

How to tune Process reaction curve 24

How to tune Process reaction curve 25

How to tune Ziegler-Nichols Method Remove integral and derivative action. Set integral time (T i ) to 999 or its largest value and set the derivative controller (T d ) to zero. Create a small disturbance in the loop by changing the set point. Adjust the proportional, increasing and/or decreasing, the gain until the oscillations have constant amplitude. Record the gain value (K u ) and period of oscillation (P u ). Use the following table to obtain new settings 26

How to tune Ziegler-Nichols Method 27

How to tune Quarterwave Quarter wave dampening approach. A good method to determine a decent setting. Induce an upset and ideally try to obtain this result No basis for the 0.25 ratio. However it has been successful and recognized in the industry including EPRI documents. 28

How to tune When you really can t tune At BNP management challenge denied original tuning plan to combination Ziegler-Nichols Method / QWD approach. HDD trip would trip the 3, 4, and 5 FWHs (6 total) on Hi-Hi level OR trip all HDPs on Low- Low level (both would result in a major power reduction) Talk of taking the integral band to the max AND inducing an upset is very uneasy given the already unstable controller. Tuning plant equipment while in service and connected directly to feedwater and reactivity is high-risk. Tuning should be performed when you are at full power operation. Do not tune at 50% power and ride up to 100% expecting similar results. Consider using the plant simulator to tune. Verify the accuracy of the simulator before attempting to tune. Most simulators you can tune equipment 29

Do not tune at reduced power Observed flowrates during start up 30

How to tune tips Apply Engineering Judgement (that term everyone is so afraid of) Be patient and watch the controllers, outputs and Process Variables. The Control valves on the HDD had response times (to respond, overshoot, settle) of over 5 minutes. Compare performance across units and across trains. If the valve was properly tuned in the past and plant conditions change tuning the gain alone should be sufficient. At BNP the Gain on the HDD controller was reduced by half. Induced a set point change and achieved the Quarter wave dampening performance that was desired. There are likely multiple tuning parameters that will deliver satisfactory performance. Do not look for one specific set of parameters 31

How to tune tips Quarter Wave dampening is important to verify you did not over dampen the controller. At steady state a dampened controller will appear stable. However if there is a plant transient, the controller may not be quick enough to recover. 32

Questions 33

34