SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT DC-4 GHz

Similar documents
HIGH REPEATABILITY, TO-5 RELAYS DPDT

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

HIGH REPEATABILITY, DC-8 GHz/20Gbps TO-5 RELAYS, DPDT

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 16 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 18 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

MAGNETIC-LATCHING DC-8 GHz TO-5 RELAYS 4PST

HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ, 20 Gbps MAGNETIC-LATCHING RF RELAY

LoopBack Relay. GLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

MAGNETIC-LATCHING DPDT HALF-SIZE CRYSTAL CAN HIGH POWER RF RELAY DC-3 GHZ

CENTIGRID ESTABLISHED RELIABILITY RELAYS

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS

Electromechanical Relays Selection Guide

Electromechanical Relays Selection Guide

Electromechanical Relays Selection Guide


1 GHz capable, 3 W carrying power (at 1 GHz), 50Ω impedance and 2 Form C relays

SMALL POLARIZED RELAY WITH HIGH SENSITIVITY

POST REFLOW HEIGHT DIMENSIONS

Series HR255/HR257 DC up to 3 GHz Magnetic Latching Space Grade DPDT Relay

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

Features. = +25 C, 50 Ohm System, Vcc= 5V

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

Series HR422/ HRS422 DC up to 1 GHz Magnetic Latching Space Grade DPDT Relay

PAGE 1/12 ISSUE SERIES DP3T/SPDT PART NUMBER R595 XXX XXX

LOW PROFILE 2 FORM C RELAY TQ RELAYS Ð Ð.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC. 200 mw.

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

Series HR412K/ HRS412K DC up to 1 GHz, High Shock Non-Latching Space Grade DPDT Relay

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Limiter Diodes Features Description Chip Dimensions Model DOT Diameter (Typ.) Chip Number St l Style Inches 4 11

Series CCS-37K/CS-37K Miniature DC 36 GHz Latching TRANSFER Coaxial Switch

Table of Contents. Kilovac Time Delay Relays

Series HR422K/ HRS422K DC up to 1 GHz, High Shock Magnetic Latching Space Grade DPDT Relay

Series CCRS-33S/CRS-33S Miniature DC 18 GHz Failsafe 2P3T Coaxial Switch

1.5 GHz MICROWAVE RELAYS. FEATURES 1. Excellent high frequency characteristics. V.S.W.R. (Max.) 1.5 (at 900 MHz) Impedance

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

Series CCT-38S Multi-Throw DC 12 GHz, SP7T & SP8T Normally Open Coaxial Switch

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

Series CCR-39S/CR-39S Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch

TITANIUM SERIES R 51 PART NUMBER SELECTION. High Performance Multiport Switches. Our Most Important Connection is with You.

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Series CCP-32N Low PIM DC 3 GHz Latching SPDT Coaxial Switch

Series CCT-38S/CT-38S Multi-Throw DC 18 GHz/DC-22 GHz Normally Open Coaxial Switch

Series CCT-59S/CT-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

AN-B21C-0004 Applications Note


AXICOM Telecom-, Signal and RF Relays. D2n V23105 Relay Nov. 07 Rev A ECOC: JM10

New pin layout (LT type) added. Best seller with broad lineup and AC 2000 V breakdown voltage.

PAGE 1/6 ISSUE SERIES Micro-SPDT PART NUMBER R516 XXX 10X. (All dimensions are in mm [inches]) R 516 _ 1 0 _

Series CCRT-33S/CRT-33S Internal 50Ω Termination DC 18 GHz/DC-22 GHz Latching SPDT Coaxial Switch

Series CCRT-33S/CRT-33S Internal 50Ω Termination DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

8W Wide Band Power Amplifier 1GHz~22GHz

AXICOM Telecom-, Signal and RF Relays. FX2 Relay Nov. 07 Rev. E ECOC: JM10

SURFACE MOUNT HIGH FREQUENCY, ACTIVE RF SWITCH SPDT

SURFACE MOUNT HIGH FREQUENCY, ACTIVE RF SWITCH SPDT

Compact Relay Family with Forcibly Guided Contacts

Series CCT-59S Multi-Throw DC-18 GHz, SP7T & SP8T Latching Coaxial Switch, Internal 50Ω Termination

30W Solid State High Power Amplifier 2-6 GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

Series CCP-47N Low PIM DC 3 GHz Latching TRANSFER Coaxial Switch

DPDT MJN2CF-IN* MJN2C-IN 3PDT MJN3CF-IN* MJN3C-IN Latching Plug-in DPDT MJN2CK

4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES

Features. = +25 C, Vcc = +5V. Parameter Min. Typ. Max. Units Frequency Range GHz Power Output 3 dbm SSB Phase 10 khz Offset -60 dbc/hz

4W Ultra Wide Band Power Amplifier 0.1GHz~22GHz

Series CCS-19 Multi-Throw DC-2 GHz Latching Coaxial Switch

PAGE 1/6 ISSUE Jul SERIES Micro-SPDT PART NUMBER R516 XXX 10X R 516 _ 1 0 _

SURFACE MOUNT HIGH FREQUENCY, ACTIVE RF SWITCH SPDT

5W Ultra Wide Band Power Amplifier 2-18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

RAMSES SERIES R 570 PART NUMBER SELECTION. SPDT up to 18 GHz. Our Most Important Connection is with You. N - TNC - BNC

Series CCRS-53S/CRS-53S Miniature DC 26.5 GHz Failsafe 2P3T Coaxial Switch

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

HMC6380LC4B. WIDEBAND VCOs - SMT. Electrical Specifications, T A. Typical Applications. Features. General Description. Functional Diagram

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Series CCR-58S/CR-58S Multi-Throw DC 26.5 GHz Normally Open Coaxial Switch

Series CCR-33K/CR-33 K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Series CCS-37S/CS-37S Miniature DC 18 GHz Failsafe TRANSFER Coaxial Switch

SMA - 50 Ohm Connectors

Ultra Wide Band Low Noise Amplifier GHz. Electrical Specifications, TA = +25⁰C, With Vg= -5V, Vcc = +4V ~ +7V, 50 Ohm System

Features. = +25 C, Vcc = +5V [1]

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Class Sealing Fully sealed Contact configuration Rated coil voltage Model Basic Type SPDT 4.5 VDC G6Y-1 5 VDC 9 VDC 12 VDC 24 VDC

Features. = +25 C, Vdc = +7V

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Series CCRT-53S/CRT-53S Internal 50Ω Termination DC-26.5 GHz Failsafe SPDT Coaxial Switch

RESISTIVE POWER SPLITTERS AND DIVIDERS

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Table of Contents. CII Mid-Range Relays

Series CCR-48K/CR-48K Multi-Throw DC 40 GHz Normally Open Coaxial Switch

Series CCR-33S/CR-33S Miniature DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

HIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))

Electromechanical Relays - Frequently Asked Questions

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Series H-33S DC up to 26.5 GHz Latching SPDT Space Grade Coaxial Switch

Parameter Min. Typ. Max. Min. Typ. Max. Units

DIP 14 SERIES REED RELAYS

Features. = +25 C, Vcc = +5V

Transcription:

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT DC-4 GHz SERIES RELAY TYPE GRF7 GRF73 Repeatable, RF relay Sensitive, repeatable, RF relay DESCRIPTION The ultraminiature GRF7 and GRF73 relays are designed to provide a practical surface-mount solution with improved RF signal repeatability over the frequency range. GRF7 and GRF73 relays feature a unique ground shield that isolates and shields each lead to ensure excellent contact-tocontact and pole-to-pole isolation. This ground shield provides a ground interface that results in improved high-frequency performance as well as parametric repeatability. The GRF7 and GRF73 extend performance advantages over similar RF devices that simply offer formed leads for surface mounting. These relays are engineered for use in RF attenuator, RF switch matrices, ATE and other applications that require dependable high frequency signal fidelity and performance. The GRF7 and GRF73 feature: High repeatability Broader bandwidth Metal enclosure for EMI shielding High isolation between control and signal paths High resistance to ESD The following unique construction features and manufacturing techniques provide excellent robustness to environmental extremes and overall high reliability: Uniframe motor design provides high magnetic efficiency and mechanical rigidity Minimum mass components and welded construction provide maximum resistance to shock and vibration Advanced cleaning techniques provide maximum assurance of internal cleanliness Gold-plated precious metal alloy contacts ensure reliable switching Hermetically sealed ENVIRONMENTAL AND PHYSICAL SPECIFICATIONS Temperature (Ambient) Vibration (General Note I) Shock (General Note I) Enclosure Weight Storage Operating GRF3 GRF33 65 C to +125 C 55 C to +85 C 1 g s to 5 Hz 3 g s, 6ms half sine Hermetically sealed.9 oz. (2.55g) max..16 oz. (4.5g) max. INTERNAL CONSTRUCTION UPPER STATIONARY CONTACT MOVING CONTACT LOWER STATIONARY CONTACT GROUND SHIELD UNIFRAME ARMATURE 215 TELEDYNE RELAYS (8) 284-77 www.teledynerelays.com GRF7/GRF73 Page 1

SERIES GRF7 / GRF73 TYPICAL RF CHARACTERISTICS (See RF Notes) Isolation Across Contacts (RF Note 4) Isolation Pole to Pole (RF Note 5) -1-1 -2-2 -3-3 -4-4 -5-5 -6-6 Insertion Loss (RF Note 6) VSWR (RF Note 6) 2. -.2 1.8 -.4 1.6 -.6 VSW R 1.4 -.8 1.2-1 1. 1.1 GRF7/GRF73 Time Response (RF Note 6).9.7 9% 37ps reference Volt.5 62.3ps propagation delay time.3.1 51.1ps pulse rise time 1% -.1-1 1 2 3 4 5 6 7 8 9 T ime ( ps) RF NOTES 1. Test conditions: a. Fixture:.31" copper clad, reinforced PTFE, RT/duroid 62 with SMA connectors. (RT/duroid is a registered trademark of Rogers Corporation.) b. Room ambient temperature. c. Terminals not tested were terminated with 5-ohm load. d. Contact signal level: 1 dbm. e. No. of test samples: 4. 2. Data presented herein represents typical characteristics and is not intended for use as specification limits. 3. Data is per pole, except for pole-to-pole data. 4. Data is the average from readings taken on all open contacts. 5. Data is the average from readings taken on poles with coil energized and de-energized. 6. Data is the average from readings taken on all closed contacts. 7. Test fixture effect de-embedded from frequency and time response data. GRF7/GRF73 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 215 TELEDYNE RELAYS

SERIES GRF7/GRF73 TYPICAL RF REPEATABILITY PERFORMANCE (See RF Notes 1,2 and 3) 1 Million Cycle Repeatability ±.1 db from DC to 3GHz.12 Typical repeatability of attenuation during life (normally open contacts).1.8 ±db.6.4.2 MAX X MIN. 1 2 3 4 5 6 7 8 9 1 Number of cycles X1 6.12 Typical repeatability of insertion loss during life (normally closed contacts).1.8 ±db.6 MAX X MIN..4.2 1 2 3 4 5 6 7 8 9 1 Number of cycles X1 6 RF NOTES 1. One million cycle repeatability data is based upon 396 observations with an average repeatability ±.33 db and a range of ±.93 db. 2. Repeatability of attenuation values were obtained from tests conducted in a 2 db attenuator network with a dbm input signal. 3. Relay operates at frequencies higher than 3 GHz with reduced RF performance characteristics. 4. Curves were developed from tests performed on a.31" copper clad, reinforced PTFE circuit board at 2 C (ref). The unutilized contacts were terminated in 5 ohms; characteristic impedance of measuring equipment is 5 ohms. The relays were mounted fl ush to the circuit board ground plane without the relay header soldered to the ground plane. 215 TELEDYNE RELAYS (8) 284-77 www.teledynerelays.com GRF7/GRF73 Page 3

SERIES GRF7 / GRF73 GENERAL ELECTRICAL SPECIFICATIONS (@25 C) Contact Arrangement Rated Duty Contact Resistance Contact Load Rating Contact Life Ratings Coil Operating Power Operate Time Release Time Intercontact Capacitance Insulation Resistance Dielectric Strength 2 Form C (DPDT) Continuous.15 Ω max. Resistive: 1Amp/28Vdc Low level: 1 to 5 μa @ 1 to 5 mv 5,, cycles (typical) at low level GRF7-5: 5 mw @ nominal coil GRF73-5: 25 mw @ nominal coil GRF7: 4. ms max. GRF73: 6. ms max. GRF7: 3. ms max. GRF73: 3. ms max..4 pf typical 1, MΩ min. between mutually isolated terminals 35 Vrms (6 Hz) @ atmospheric pressure DETAILED ELECTRICAL SPECIFICATIONS (@25 C) BASE PART NUMBERS (GRF7) GRF7-5 GRF7-12 Coil Voltage, Nominal (Vdc) 5. 12. Coil Resistance (Ohms ±2%) 5 39 BASE PART NUMBERS (GRF73) GRF73-5 GRF73-12 Coil Voltage, Nominal (Vdc) 5. 12. Coil Resistance (Ohms ±2%) 1 85 GRF7/GRF73 Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 215 TELEDYNE RELAYS

SERIES GRF7/GRF73 OUTLINE DIMENSIONS.335 MAX (8.51).31 (.79) REF.35 (.89) REF.315 MAX (8) (GRF3).425 MAX (1.6) (GRF33) SEE NOTE 3.375 MAX (9.52) 6 LEADS.35 REF (.89) U.S. PATENT PENDING.2 ±.1 (5.98 ±.25) (Viewed From Terminals) 36 ±3 TYP SCHEMATIC DIAGRAMS 9 8 7 6 1 2 3 4 GRF7/GRF73 NOTES: 1. DIMENSIONS ARE IN INCHES, METRIC EQUIVALENTS SHOWN IN [ ]. 2. POSTITIONS 5 AND 1 ARE FOR UNINSULATED CASE GROUND OPTIONS. 3. NO PROTRUSION BELOW BOTTOM OF HEADER WHEN GROUND PINS ARE INSTALLED 4. TO ORDER THE CASE GROUND OPTION, AFTER THE SERIES DESIGNATOR, ADD Y TO THE PART NUMBER FOR POSITION 5 OR Z TO THE PART NUMBER FOR POSITION 1. 5. UNLESS OTHERWISE SPECIFIED, TOLERANCES ON DIMENSIONS ARE ±.1 INCH (.25 MM) Teledyne Part Numbering System for GRF7/GRF73 Relays Relay Series GRF73 Y - 5 Ground Pin Option (See Appendix A) Nominal Coil Voltage GENERAL NOTES I. Relays will exhibit no contact chatter in excess of 1 μsec or transfer in excess of 1 μsec. II. For reference only. Coil resistance not directly measureable at relay terminals due to internal series diode. 215 TELEDYNE RELAYS (8) 284-77 www.teledynerelays.com GRF7/GRF73 Page 5