Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

Similar documents
Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data

Instruction Manual RT-93285SL RR-93285SL Thirty-two Channel Video Multiplexer With Two Bi-directional Data Channels

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels

af i Instruction Manual MR-944C Four Channel Video Receiver With One Bi-Directional Multi-Protocol Data Channel american fibertek 11/30/2012 JPK

Instruction Manual MX-480 Bi-directional Multi-Protocol Data

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Document # Rev. C October, GEMINI EXPRESS MULTIPLEXER User s Guide

Series 3000 Model R-107A

OM7AT & OM7AR1 (Stand alone) ROM7AT & ROM7AR1 (Rack mount)

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

Gemini Express Fiber Multiplexer User s Guide

Video/Audio Transmission System Series VA700. (formerly Series DVL4A)

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

Data Acquisition Modules/ Distributed IO Modules

DL102 Counter Loop Amplifier

PTR-1500 AUDIO TONE TELEPROTECTION TERMINAL FEATURES DESCRIPTION

Active CCTV Receiver Balun Installation Guide

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Glass Electrode Meter

AMP-13 OPERATOR S MANUAL

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide

Contents. Warranty and Disclaimer 2 Introduction 3

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

TIA-527 Balanced Optical/Electrical Converter. Operating Instructions

Instruction Manual Model M Switch, DPDT, Manual Select

Model 7000 Low Noise Differential Preamplifier

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

INSTALLATION GUIDE. 8 Port IP Video Extender Over Coax With Built-In Gigabit PoE Switch

LongReach II Active CCTV Receiver Hub [8P], [16P] Installation Guide

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Amplified High Speed Photodetectors

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Broadband Step-Up Transformer. User Manual

LTX-5520 Electrical / Optical Converter Operating Instructions

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

RFTX-1 Installation Manual

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

PCO-7114 Laser Diode Driver Module Operation Manual

Digital Lighting Systems, Inc.

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

MaxLite LED Self-Driven LiteBars

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

1.5µm PbSe Power Detector

INSTRUCTION MANUAL. March 11, 2003, Revision 3

A-16D A-Net Distributor

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Document Version 1.2

TIA-500 Optical/Electrical Converter Operating Instructions

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

CAB LINK User Guide. Radial Engineering Ltd Kebet Way, Port Coquitlam BC V3C 5M5 Tel: Fax:

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

PI-10 Broadband Power Indicator

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Y1160A EIA Rack Sliding Shelf Installation Note

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Copyright Teletronics International, Inc. Patent Pending

Transmitter. User Manual. Firmware version 1.0 and greater

User s Manual. VA700XD Series. Fiber Optic Baseband Video /Audio. Installation and User Guide

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

PI-150 Broadband Power Indicator

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

TIA-952 Optical/Electrical Converter. Operating Instructions

Manual and User Guide

Serial Communications RS232, RS485, RS422

Model 1791 VHF Radio User's Manual

PSI MIN MODULATOR BIAS CONTROLLER BOARD

16 Port. RF Multicoupler User s Guide 16 PORT RFM

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

Amplified Photodetectors

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

VPD (Video/Power/Data) Combiners

VideoEase Component Video Hub (500250, , , ) Installation Guide

Synthesized Base Station Transmitter

Cross-Connect Interface

Big Bang. SpeakerCraft. BB1235 Owner s Manual. Power Amplifiers

80i-600A AC Current Probe

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

INSTALLATION INSTRUCTIONS ROLLER SHADES

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

VOLUME CONTROL CONNECTION TERMINAL

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers

XIA3145 INSTALLATION/OWNER S MANUAL 2/1-Channel Mobile Power Amplifier

ACT-IR220Li/220LN IrDA Serial Port Adapter

Submittal 420I Converter

Transcription:

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data Copyright 2005, American Fibertek, Inc. 1027JD

Table of Contents Functional Description...3 Installation...3 Power Source...4 Power Connection...4 Input / Output Connections...4 Typical System Data Connections...5 Data Configuration Switches...6 MTX-8485C Status LED Indicators...8 MRX-8485C Status LED Indicators...9 Data Termination Requirements...10 Offset Bias - RS485 Data Signals...11 Warranty and Service Information...12 2

INSTALLATION AND OPERATION INSTRUCTIONS INTRODUCTION Thank you for purchasing your American Fibertek Series 8485C multimode four channel video multiplexer with bi-directional data. Please take a few minutes to read these installation instructions in order to obtain the maximum performance from this product. FUNCTIONAL DESCRIPTION The 8485C Series units operate as a transmitter / receiver pair for the transmission of four simultaneous, real time baseband NTSC/PAL video signals with field configurable bi-directional data over a single multimode fiber optic cable. This link can accommodate either a single RS485 interface (2 or 4 wire) or both a RS422 and RS232 interface. When used in RS422/RS232 mode, each interface functions independent of the other. These units are factory shipped configured in the RS485 (4 wire) configuration. The MTX-8485C transmitter accepts four video inputs and multiplexes these signals along with the data signals onto a single optical output port for connection to the fiber transmission system. Correspondingly, the MRX-8485C receiver converts the optical signal to four independent video output signals along with the data signals. The 8485C Series units operate on 50 um or 62.5 um multimode fiber. Refer to the data sheets for detailed performance specifications. The individual units may be configured for rack mounting or wall mounting depending upon the position of the included mounting hardware. INSTALLATION THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES. To install the MTX-8485C or MRX-8485C it is first necessary to mount the rack flanges to the unit. For rack mounting the ears are installed on the sides of the unit with the surfaces that have oval holes flush with the front of the unit as in Figure 1. Mount the ears with the #10 flathead screws provided. To mount in the rack cabinet, use mounting screws that are appropriate for the rack cabinet being used. 3

For mounting the unit flush to a wall or other rigid surface, the ears may be installed on the sides with the oval holes flush with the bottom of the unit as in Figure 2. Mount the ears with the #10 flathead screws provided. Mount the unit to a rigid surface using #10 (5mm) screws. POWER SOURCE The internal power supply accepts universal line voltage. Any mains supply from 100 to 240 VAC, 50 to 60 Hz may be used without modification or adjustment. A universal power connector is provided on the rear of the unit to facilitate connection to the power mains. POWER CONNECTION The unit is supplied (in the US and UK only) with a three conductor power cord. The ground conductor is directly connected to the chassis. INPUT / OUTPUT CONNECTIONS The fiber optic connection is made via a ST connector located at the back of the unit. Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used. Video input and output connections are located on the rear of the unit. A BNC connector is provided for each channel. Please note that channels five through eight are not used in this unit. The video inputs are connected to an appropriate 75Ω baseband source such as a camera or a video recorder output. The 75Ω video outputs can be looped through typical baseband video inputs of switchers, recorders and other equipment as required. For proper operation, the outputs must be terminated with 75Ω. For optimum performance the video cables should be the shortest length of coax practical. Data input and output connections are located on the rear panel terminal block. A mating plug connector is provided. The figure below identifies the specific connections for the RS485 data connections. See next page for RS422 / RS232 data connections. 4

The figure below identifies the specific connections for the RS422 / RS232 data connections. TYPICAL SYSTEM DATA CONNECTIONS An example of the RS422 or RS485 four wire interconnection between the 8485C series unit and the copper device to which it is attached is shown below. This illustration is based on industry standard EIA terminology for the transmission of electronic data signals. Using this terminology, the driver of an electronic signal is labeled TX or data out. Correspondingly, the receiver of an electronic signal is labeled RX or data in. Not all manufactures follow standard EIA terminology. Consult the installation instructions for your copper device if you are unsure which two wires are the drive (data out) wires and which two wires are the receive (data in) wires. MTX-8485C or MRX-8485C Please note that Data In on the MTX-8485C becomes Data Out on the MRX-8485C after going across the fiber. The reverse flow follows the same orientation. Also note that RS485 two wire transmission uses only pins 6, 7, and 8 of the data terminal block. 5

DATA CONFIGURATION This link accommodates transmission of: 1) 1 bi-directional RS485 (2 wire or 4 wire) data channel, or 2) 1 bi-directional RS422 data channel, or 3) 1 bi-directional RS232 data channel, or 4) 1 bi-directional RS232 data channel and 1 bi-directional RS422 data channel. These units are factory shipped configured for RS485 (4 wire) configuration with data input and output termination resistors in and no offset bias. There is a rear panel data configuration switch bank which is available to select: 1) RS485 or RS422/RS232 data modes 2) RS485 (2 or 4 wire) format 3) Internal data input/output terminations 4) RS485 Offset Bias Option RS485 FOUR WIRE SWITCH SETUP The following is an illustration of the data configuration switches that identifies the specific switch function and up/down direction for RS485 four wire transmission. 6

RS485 TWO WIRE SWITCH SETUP The following is an illustration of the data configuration switches that identifies the specific switch function and up/down direction for RS485 two wire transmission. RS422 / RS232 SWITCH SETUP The following is an illustration of the data configuration switches that identifies the specific switch function and up/down direction for RS422/RS232 transmission. 7

MTX-8485C STATUS INDICATORS The MTX-8485C transmitter provides the following front panel LED status indicators to aid in installation and troubleshooting: DATA These indicators turn green when any data activity is present. An active DATA TX LED indicates data is present at the input terminals to the MTX-8485C. An active DATA RX LED indicates data is present at the output terminals of the MTX-8485C. When configured for RS-485, an active Hi- Z LED indicates the MTX-8485C has seized the data line to allow data flow. The intensity of the indicators will vary with input data patterns, however, the Hi-Z LED will typically appear dimmer than the data Tx and Rx LEDs. The data channels associated with these front panel DATA LEDs are listed below. Configuration Protocol DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX RS485 Configuration RS485 Tx RS485 Rx Hi-Z Hi-Z RS422 Configuration RS422 Tx RS422 Rx Not Used Not Used RS232 Configuration Not Used Not Used RS232 Tx RS232 Rx RS422/RS232 Configuration RS422 Tx RS422 Rx RS232 Tx RS232 Rx OLI A bi-color LED indicator monitors the optical input power of the data signal that is being received at the MTX-8485C from the MRX-8485C. AC power and optical input status associated with this LED are summarized below. Optical Level Indicator AC Power Status Optical Status Green On Proper Optical Input Power Present Red On Optical Input Not Detected Off Off Check Power Supply Input VIDEO A bi-color LED indicator is provided for each of the four video channel inputs. Please note that video channels five through eight are not used in this unit. AC power and video status associated with each of these LEDs are summarized below. Video Presence LED AC Power Status Video Status Green On Proper Input Video Present Red On Input Video Not Detected Off Off Check Power Supply Input 8

MRX-8485C STATUS INDICATORS The MRX-8485C receiver provides the following front panel LED status indicators to aid in installation and troubleshooting: DATA These indicators turn green when any data activity is present. An active DATA TX LED indicates data is present at the input terminals to the MRX-8485C. An active DATA RX LED indicates data is present at the output terminals of the MRX-8485C. When configured for RS-485, an active Hi-Z LED indicates the MRX-8485C has seized the data line to allow data flow. The intensity of the indicators will vary with input data patterns, however, the Hi-Z LED will typically appear dimmer than the Data Tx and Rx LEDs. The data channels associated with these front panel DATA LEDs are listed below. Configuration Protocol DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX RS485 Configuration RS485 Tx RS485 Rx Hi-Z Hi-Z RS422 Configuration RS422 Tx RS422 Rx Not Used Not Used RS232 Configuration Not Used Not Used RS232 Tx RS232 Rx RS422/RS232 Configuration RS422 Tx RS422 Rx RS232 Tx RS232 Rx OLI 1 A bi-color LED indicator monitors the power of the optical input signal that is being received at the MRX-8485C from video channels one through four of the MTX-8485C. AC power and optical input status associated with this LED are summarized below. Please note that data is sent as a subcarrier on channel one s video signal. Optical Level Indicator AC Power Status Optical Status Green On Proper Optical Input Power Present Red On Optical Input Not Detected Off Off Check Power Supply Input 9

DATA TERMINATION REQUIREMENTS RS232 Data Signals The RS232 interface standard is a point to point transmission protocol for digital signals. It allows for a single transmitter device communicating to a single receiving device. This configuration is mirrored in the opposite direction to create one bi-directional data path. Devices using this protocol have terminating resistors built into their data path. This eliminates the need for any switch selection for termination resistors in the RS232 mode. RS422 Data Signals The electrical interface described in RS422 is a data transmission standard for balanced digital signals. It allows for a single transmitter device communicating to as many as 32 receiving devices. This type of data signal is well suited to systems that require data to be distributed to several points without a return data path. Several companies offer camera telemetry controllers using this data interface. Because there is only one transmitting device on the network, this one may remain active at all times. There is no need for the driver to go into a high impedance state to allow others to "talk." A configuration using multiple drivers on the same wire pair is exclusive to RS485 described in the next section. In most cases termination resistors are not required to be applied to RS422 data outputs. In long copper runs (over 500 feet) termination resistors may be required to eliminate data reflections. Termination resistors for RS422 data can be selected in the MTX-8485C and MRX-8485C using switch #2 and switch #5. RS485 Data Signals RS485 differs from RS422 in the ability of the transmitter devices to go into a high impedance (Hi-Z) state. This allows multiple transmitter devices to reside on the same wire pair. The software must dictate a protocol that allows one device to transmit at any one time to prevent data crashes. Data wiring can use two wires or four wires. Using two wires the system works in half duplex. This means that data is exchanged between two points sequentially. When a fourwire system is used, the system may be full duplex. In many cases the system head end controller will continuously poll data from all remote devices. The remote devices all respond back to the head end (one at a time!) as they are addressed. This property of the network rests solely in the hands of the software (firmware). The driver chips used in RS485 communications are capable of changing into their high impedance state very rapidly. On even short lengths of wire there can exist a residual voltage after a driver circuit turns off. This can interfere with circuits that are used to detect the Hi-Z state. It is very important that the copper communications lines be terminated with resistors across the data wire pair. The best place to locate such resistors is at the furthest electrical devices at the ends of the wire pair. For instance, if several RS485 devices are connected in a daisy chain fashion, the wire connection would loop across all devices in a chain. The furthest two points in the chain would need to be terminated. Termination resistors for RS485 four wire data can be selected in the MTX-8485C and MRX-8485C using switch #2 and switch #5. A termination resistor for RS485 two wire data can be selected in the MTX-8485C and MRX- 8485C using switch #5. 10

OFFSET BIAS RS485 The RS485 specification requires receivers to detect input signals down to 200mVp-p of voltage level. In many cases this can cause systems to be sensitive to noise on the data wires. In an effort to eliminate the effects of low levels of noise, some manufacturers of equipment that communicate using RS485 have introduced a small voltage bias to the data lines. This is usually accomplished using a 470 Ohm resistance to +5V on the positive line and 470 Ohm resistance to ground on the negative line. When used in conjunction with the appropriate termination resistors referred to in the previous section, this introduces about a 300 mv offset, improving noise immunity. Offset bias for four wire RS485 can be applied on the MTX-8485C and MRX-8485C by setting switch # 1 and switch # 3 down. Please note that these switches work as a set and must be either both down or both up. In a majority of cases, bias will not be required and these switches should remain in the up position. If using offset bias, it is important that termination resistor switch # 2 and switch # 5 be in the down (applied) position. Using offset bias without a termination on the line will cause communications to fail. Offset bias for two wire RS485 can be applied on the MTX-8485C and MRX-8485C by setting switch # 4 and switch # 6 down. Please note that these switches work as a set and must be either both down or both up. In a majority of cases, bias will not be required and these switches should remain in the up position. If using offset bias, it is important that termination resistor switch # 5 be in the down (applied) position. Using offset bias without a termination on the line will cause communications to fail. 11

LIFETIME WARRANTY INFORMATION American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of defects in materials and workmanship. Defective products will be repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization (RMA) number is required to send the products back in case of return. All returns must be shipped prepaid. This warranty is void if the products have been tampered with. This warranty shall be construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for contingent, consequential, or incidental damages. No agreement or understanding, expressed or implied, except as set forth in this warranty, will be binding upon American Fibertek unless in writing, signed by a duly authorized officer of American Fibertek. SERVICE INFORMATION There are no user serviceable parts inside the unit. In the event that service is required to this unit, please direct all inquiries to: American Fibertek, Inc. Phone: (877) 234-7200 120 Belmont Drive Phone: (732) 302-0660 Somerset, NJ 08873 FAX (732) 302-0667 E-mail: techinfo@americanfibertek.com 12