Process Protection Acoustic sensors for pump monitoring

Similar documents
Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

SALES SERVICE +358 (0)

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Isolators A3/1. Vibration Transducer Supply Unit Series

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

KINAX WT 707 Transmitter for angular position

Binary Output Series 9175

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1.

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolating Repeater Input Series 9163

Positioner with HART Communication Type 3780

Operating Instructions

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Temperature Input Module for Zone 1 Series 9482/32

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Digital Input Output Module for Zone 2 Series 9470/33

Binary Output without Power Supply Series 9176

Level Limit Switch nivotester FTL 325 P

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

Digital I/O Coupler (4-wire) Series 9413/21

SITRANS T measuring instruments for temperature

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Inductive sensor slot-type SI2-K08-AP7

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Technical Data. General specifications. Rated operating distance s n 3 mm

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 2 Series 9470/33

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Fieldbus Isolating Repeater Series 9185/11

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Level Limit Switch nivotester FTL 370, FTL 372

Isolators A3/1.

Installation guide 971 SmartRadar LTi

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

OPTITEMP TT 10 C/R Technical Datasheet

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS T measuring instruments for temperature

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

RMA42. Technical Information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Remote Switching Unit nivotester FTL 320

Temperature Measurement

OEM radar transmitter, for aggressive media level measurement

ED701 General Industry Pressure Transmitter

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Head mounted Temperature Transmitter TF02/TF02-Ex

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

KFS. Flap-type flow meter. Design and range of application

Rudder or propeller angular position transmitter KINAX WT720

Page Type Resolution (mm) min. max. Output

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Resistance thermometer Model TR30, compact design

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Temperature Measurement Transmitters for mounting in sensor head

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Remote I/O. 74 Remote I/O. Remote I/O System

Plug-in module SIRAX TI 807 Passive DC signal isolator

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Technical Information Nivector FTC968, FTC968Z

Design and applications

... for hydraulic and general applications in hazardous areas

Ultrasonic level measuring device, non-contact

SITRANS P. Transmitters for level. Introduction 1/42. Application

Submersible pressure sensor For water and wastewater Model LW-1

Coriolis Massflowmeter

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Relative and absolute pressure transmitter type 528

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Level and Pressure. Product Information. Vibrating level switches

Ultrasonic level meters ULM 70

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

SITRANS T measuring instruments for temperature

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Single-Channel Safety Barriers Series 9001

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Technical Information Condumax CLS21D/CLS21

Coriolis Massflowmeter

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Transcription:

coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement pumps In the version for material flow monitoring; on pipes, conveying equipment or channels. It comprises an electric diagnostic unit and up to four acoustic sensors. enefits enefits when pump monitoring Increased availability of the system through: - dvanced maintenance planning thanks to early recognition of defective components - Reduced downtimes (no fault locating necessary) - Increased maintenance intervals - Greater pump reliability Prevention of expensive consequential damage Increased safety of critical applications Early recognition of a reduction in power Increased productivity enefits when material flow monitoring Detection of insufficient or excessive inflow of material in a liquid or gas flow Detection of blockages or clogging Reduction of down times Increased product quality Increased availability Guaranteed operational safety Increased productivity pplication In the version for pump monitoring, the allows continuous, simultaneous and independent monitoring of up to four flow control valves in a pump for leaks. In addition, another four inputs are available for monitoring standard signals (e.g. diaphragm and temperature monitoring). This means that the condition of an oscillating displacement pump is monitored in every phase of its operation. The is used in all industries where an oscillating displacement pump is used. The version for material flow monitoring monitors the material flow in liquids or gases that is usually as a result of impact or friction, e.g. against the pipe or channel wall. If the acoustic diagnostic unit is used in potentially explosive areas, the sensors as well as the acoustic diagnostic unit can be installed in the Ex-zone. If using the unit in potentially explosive areas, you have two options: Operation of the sensors over the safety barriers or Operation of the sensors over the with explosion protection Function Product features Continuous and independent status monitoring: Of the flow control valves, for leaks Of the membranes, for material fatigue Of the temperature loading of the hydraulic oil Of flowing bulk solids in pipes, conveying equipment or channels Communication of the status to superordinate control systems: Via digital outputs Digitally, via PROFIUS DP or PROFIUS P Simple to operate and parameterize: Locally, via digital display and keys PROFIUS DP and PROFIUS P Mode of operation Principle of measurement Leaks in the flow control valves of oscillating displacement pumps are flows in which cavitation occurs. This results in sound waves that are transmitted to the valve housing, where they are recorded by the structure-borne sound sensor in the on the outside. The utilizes the fact that with both an open valve and a closed intact valve, no cavitation occurs and the measured sound level thus corresponds to the operating noise of the pump. y contrast, with a closed defective valve cavitation does occur, which can be identified by a period increase in the sound level (see figures). The measured value from the corresponds exactly to this increase in the sound level. In the version for material flow monitoring, continuously detects high-frequency acoustic oscillations by means of structure-born noise sensors. /5

coustic sensors for pump monitoring acoustic diagnostic unit These oscillations are created by: Friction and impact of bulk solids in: - pipes, raceways or channels -chutes -conveyors Friction and impact of mechanical parts ursting of bubbles Cavitation Turbulence in gas and liquid flows The following shows an example of signal levels at an oscillating displacement pump Signal from structure-borne sound sensor with intact valve Signal from structure-borne sound sensor with defective valve Sensor operation The structure-borne sound sensor works on the piezoelectric principle. The structure-borne sound is injected into the sensor via the sensor base (mounting surface) and inside it is converted into an electrical voltage by a piezo-ceramic element. This is amplified in the sensor and transmitted via the cable. The sensor frequency range lies in the ultrasonic range (> 20 khz). The sensor is non-directional, i.e. the angle at which the sound wave impacts on the sensor base is not important. Mode of operation of the safety barrier The safety barrier comprises intrinsically-safe circuits. These circuits serve to operate intrinsically-safe components such as sensors and to isolate safety from the non-hazardous area with the diagnostic unit. Technical specifications With coustic channels 4 Cycle time 10 ms Only for connection to intrinsically safe sensors with: Max. voltage U o - 5.5 V Max. current I o - 70 m Max. power P o - 100 mw Internal capacitance C i - 1.2 F Internal inductance L i - Negligible Universal inputs 4 Cycle time 80 ms Low pass filter time 1 s Universal analog current input Load < 105 <12 Resolution 0.1 % ccuracy 0.5 % Fault signal > 21 m or < 3. m (at 4... 20 m) larm monitoring hysteresis 0.5 % Static destruction limit 40 m, 4 V - Max. supply voltage U i - 30 V Max. short-circuit current I i - 100 m Max. power P oi - 1 W Internal capacitance C i - 11 nf Internal inductance L i - 70 H Universal input 24 V digital signal resistance > 19 k Signal level Low < 4.5 V or open Signal level High >7V Hysteresis >1V Static destruction limit ± 40 V - Max. supply voltage U i - 30 V Max. short-circuit current I i - 100 m Max. power P oi - 1 W Internal capacitance C i - 11 nf Internal inductance L i - 70 H Universal input closing contact For connection to closing contact with the maximum values: - Max. voltage U o - 10 V - Max. current I o - 1 m -Max. power P o - 5mW - Internal capacitance C i - 11 nf - Internal inductance L i - 70 H 8.2 V source for NMUR signal (DIN EN 0947-5-) Open circuit voltage 8.2 V ± 0.3 V, - short-circuit proof resistance < 950 - Static destruction limit for incorrect wiring +20 V/-10 V - /

With Output Digital outputs (applicable for NMUR switch hardener) Semiconductor relay Individually isolated, - short circuit- proof Switching voltage 24 V C/3 V DC, - any polarity Destruction limit 35 V C, 50 V DC - Max. switching current 100 m - Signal status Low (no response) - 1.2 m (source to DIN 19234) Signal status High (response) - 2.1 m (source to DIN 19234) For connection with an intrinsically safe switching amplifier to DIN 19234 with: Max. supply voltage U i - 15.5 V Max. short-circuit current I i - 25 m Max. power P oi - 4 mw Internal capacitance C i - 5.2 nf Internal inductance L i - Negligible Installation conditions Vertical wall mounting, cables fed in from below Climatic class Class 4K4 according to EN 0721-3-4 Mounting location - Zone 1 or zone 2 Permissible ambient temperature -20... +0 C (-4... +140 F) - Temperature class T5... T1-20...+0 C (-4... +140 F) Temperature class T -20...+50 C (-4... +122 F) Mechanical load Class 4M3 according to EN 0721-3-4 Degree of protection to EN 0529 IP5 Electromagnetic Compatibility Emitted interference and To EN 132 and NMUR NE 21 interference immunity Usage limits for water Delivery side 10 bar a Number of strokes Min. 4 min -1, max. 10... 500 min -1 Weight (without options) pprox. 2.5 kg Dimensions (W x H x D) in mm 172 x 320 x 80 (.8 x 12. x 3.2) (inch) Enclosure material Macrolon (polycarbonate + 20 % glass fiber) Makrolon (Polycarbonate + 20 % glass fibers), surface attenuated with CrNi layer and painted Electrical connection via screw terminals Cable inlet via plastic cable joints 2 x Pg 13.5 5 x Pg 11 Rigid 2.5 mm (0.984 inch) Flexible 1.5 mm (0.59 inch) Flexible with connector sleeves 1.5 mm (0.59 inch) coustic sensors for pump monitoring acoustic diagnostic unit With Power supply Rated voltage 24 V DC 1 V DC Operating range 19... 3 V DC 15... 17 V DC Current consumption < 100 m < 40 m Max. supply voltage U i - 17.4 V Max. short-circuit current I i - 191 m Max. power P oi - 1.35 W Internal capacitance C i - 33 nf Internal inductance L i - 28 H Certificates and approvals to EN 50014, EN 50020 and EN 50021 Intrinsic safety "i" - TÜV (German Technical Inspectorate) 0 TEX 2952 Marking - II 2(1) G EEx is [ia] IIC T Communication PROFIUS DP RS 485, switchable terminating resistor Protocol Cyclic with Master C1 and acyclic with Master C2 Power supply - us-supplied us voltage - 9... 24 V Current consumption - 10.5 m ± 10 % us connection with FISCO supply unit, ia/ib group IIC or II - Yes Layer 1 and 2 from PROFIUS P, - transfer technology from IEC 1158-2 C2 connections - 4 connections are supported in master class 2 Device profile - PROFIUS P Profil V3.0 Rev. 1, Class Device address - 1... 12 (12 factory-set) PC parameterization software SIMTIC PDM (not included in the scope of delivery) /7

coustic sensors for pump monitoring acoustic diagnostic unit Sensor for Setup Piezoceramic sensor with pre-amplifier Encapsulated electronics 4-wire cable with anti-kink sleeve Permissible ambient temperature -40... +110 C (-40... +230 F) Degree of protection to EN 0529 P/IP8 Mechanical load Class 4M7 according to EN 0721-3-4 Climatic class Class 4K4 according to EN 0721-3-4 Housing material Stainless steel 1.4571 (31Ti SST) Cable Ends with wire protectors and cable shoe for connection to the SITRNS D400 Weight 125 g (0.27 lb) Mounting location Zone 0/1 or zone 20/21/22 Dimensions (W x H x D) in mm (inch) 2 x 29 x 40 (1.02 x 1.14 x 1.57) Power Supply Power fed from device Certificates and approvals Intrinsic safety "i" TÜV 2005 TEX 287 X Marking II 1 G EEx ia IIC T/T5/T4 or II 1 D EEx ia D 20/21/22 T10 Permissible ambient temperature Category 1G - Temperature class T4, T5-20... +0 C (-4... +140 F) - Temperature class T -20... +50 C (-4... +122 F) Category 2G - Temperature class T4-40... +110 C (-40... +230 F) - Temperature class T5-40... +80 C (-40... +17 F) - Temperature class T -20... +5 C (-4... +149 F) Category 1D or 2D - Temperature class T10-40... +110 C (-40... +230 F) Ex barriers for sensors pplication area For the intrinsically safe supply of the acoustic sensors in zone 1; the safety barriers must be installed between the acoustic diagnostic unit and the sensor if only the sensors are being operated in the Ex zone. maximum of two sensors can be connected. Degree of protection to EN 0529 IP20 Permissible mbient Temperature -20... +0 C (-4... +140 F) Weight 115 g (0.254 lb) Housing material Plastic, polyamide Type of installation Installation on mounting rail NS 32 or NS 35/7.5. The acoustic diagnostic unit and the safety barrier must be operated outside the Ex zone. Dimensions (W x H x D) in mm (inch) 8 x 77 x 42 (2.8 x 3.03 x 1.5) Certificates and pprovals Intrinsic safety "i" TÜV 05 TEX 2917 X Marking II (2) G [EEx ib] IIC Selection and Ordering data rticle No. coustic diagnostics unit 7MJ2400-7 7 0 7 with local programming and display Click on the rticle No. for the online configuration in the PI Life Cycle Portal. Communication PROFIUS DP 1 PROFIUS P 2 With EEx ia/ib to TEX 1) pplication software For continuous condition monitoring of positive displacement pumps For material flow monitoring in pipes, raceways and conveyors coustic sensors for diagnostics unit Click on the rticle No. for the online configuration in the PI Life Cycle Portal. With EEx ia to TEX 1 2 7MJ2000-1 7 7 0 0 Cable (incl. pin and allen screw M) 20 m 40 m C 100 m F Safety barriers for sensors For rail mounting NS 32 and NS35/7.5 in non-hazardous areas Explosion-protected output circuit EEx ib 7MJ2010-1 1) Not in combination with trigger sensor. /8

coustic sensors for pump monitoring acoustic diagnostic unit Dimensional drawings.5 (0.2) Ø40 (1.57) 7 (0.28) 11 (0.43) 10 (0.39) 15 (0.59) 9 (0.35) Ø3 (0.12) 2 (1.02) 28.5 (1.12) (0.24) Out1, Out2 SENSOR 49 (1.9) 47 (1.8) 42 (1.) 70 (2.7) In1, In2 12 (0.5) Foot element Sensor for, dimensions in mm (inch) 8 (2.7) 172 (.77) D 5 (0.2) 10 (0.394) D - D 77 (3.0) 30 (12.05) 94 (3.70) D 94 (3.70) 28 ± 0.2 (11.2 ± 0.008) 1) Ø.5 (0.2) Ø13 (0.511) 29 (10.59) Safety barrier for, dimensions in mm (inch) Circuit diagrams 41 42 51 52 Out1 Ground terminal 22 21 32 31 In1 17 (0.7) 1) 152 ± 0.2 (5.98 ± 0.008) 80 (3.15) pprox. 30 (1.18) Out2 41 42 51 52 Intrinsically safe towards sensor In2 22 21 32 31 Not intrinsically safe towards Pg 13.5 SW 24 Pg 11 SW 22 1) 3 mounting holes (M) Safety barrier for, terminal assignment, dimensions in mm (inch) Supply L+/L- DO Sens Power supply (ny polarity with PROFIUS P) Digital output Sensor In yl gr br bl I+ Yellow Green rown lack nalog current input + DI Ground Digital input Signal (green) with PROFIUS DP, any with PROFIUS P Signal (red) with PROFIUS DP, any with PROFIUS P, terminal assignment /9