Spectroradiometer series NEW

Similar documents
Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

CS-2000/2000A. Spectroradiometer NEW

Achieving 100,000 : 1 contrast measurement

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Ultimate and Versatile 2D Spectroradiometer is finally released!

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Spectroradiometer specbos 1201

Broadbandradiometer specbos 1211

Ultra low luminance measurement performance of the industry's top-level.

Miniaturized Spectroradiometer

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting

Konica Minolta LS-110 Specs Provided by

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

JETI Specbos Instruments

specification display & lighting hera spectrometer

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

LED Tester BTS256-LED

ILLUMINANCE METER LUMINANCE METER CHROMA METER T-10A /T-10MA/ T-10WSA/T-10WLA CL-200A CL-500A LS-100/LS-110 CS-100A CS-200

ILLUMINANCE METER T-10 Series

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

We bring quality to light. MAS 40 Mini-Array Spectrometer

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

illumia Plus Temperature Controlled Light Measurement Systems

Chameleon Spectroradiometer

ILLUMINANCE METER T-10 Series

Illuminance Meter. series

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Eternal Shine Technology Co.,Ltd. EST

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Gamma Scientific Display Measurement Systems

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

AvaLight-DHc Full-range Compact Light Source

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

QPL ID # PLG2YNJ831VZ

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

BTS2048-VL-CP-ILED-B-IS-1.0-HL

Microscope-Spectrometer

Imaging Photometer and Colorimeter

Photometry for Traffic Engineers...

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

REVOLUTION LIGHTING TECHNOLOGIES INC

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

PR-655 PR-670 PR-680 and PR-680L SpectraScan

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

RoHS QPL ID # PLC6V1PABNUJS

Contents. Contents. Part 4. Specification. Part 1. Feature. Feature Merit Configuration. Specification Dimension Diagram

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

We bring quality to light. CAS 120 CCD Array Spectrometer

Cat# LED Wall-PACK

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

We bring quality to light. CAS 140CT Array Spectrometer

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometry for Traffic Engineers...

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

EDUCATION EXPERIMENT. Determining Color Difference (Delta E) Introduction

Transcription:

Spectroradiometer series Added Special HighSpeed mode.

Topcon provides wide variety of Spectroradiometer for ultra-low luminance measuring, ultra-high luminance and Near infrared measurement. SR-LED series is best suited for the inspection of High-intensity LED. Half band-width is 5nm or less 0.0005 to 5,000,000 cd/m 2 0.0005 to 5,000,000 cd/m 2 10 to 4,500,000 cd/m 2 SR series Spectroradiometer is suited to measure Spectral distribution, Luminance, Chromaticity and Correlated color temperature of the light emitted from display device, car interior and lamp. Customize 0.0005 to 300,000 cd/m 2 0.0005 to 300,000 cd/m 2 0.001 to 300,000 cd/m 2 Product features Half band-width is 5nm or less. SR-LEDW-5N has a half-width of 5 nm or less, which is required by colorimetry (JIS Z 8724-1997) in a visible light region. Most suitable for measuring directly to ultra-high intensity LED light. Ultra-high intensity LED light can be measured directly without Integrating sphere, diffusing board and external ND filter. It is easy to manage by the luminance which repeatability is higher. Also, measurement range of luminance is up to 4,500,000 cd/m 2 when measurement angle is 1. *Only SR-LED series High uniformity of the sensitivity on the measurement area. Uniformity of the sensitivity on the measuring area is within 5% in luminance and within 0.001 in chromaticity at measuring angle of 1. * SR-LEDW only. High accuracy measurement of flashing light. Synchronous measurement function. The instrument can detect and measure frequency of flash by inputting synchronous signal. Arbitrary frequency value can be set manually. Integral time delay function. Following kind of light can be measured with stable; Frequency flashing of light on black screen, Intermittent light, and Periodic flashing light. Spectral observation. SR series can conduct spectral radiance measurement and so that spectral distribution and spectral radiance can be observed. High accuracy Luminance and Chromaticity measurement. Accuracy (Luminance) : ±2%, Accuracy (Chromaticity) : dxdy ±0.002 * In Normal speed mode at measuring angle of 2 for standard illuminant A. High speed measurement for in-line inspection is 0.4sec (minimum). LAN (Ethernet 10/100 BASE-TX) communication allows high speed measurement of 0.4sec. *Under angle 2, Integral time 100ms, High speed mode and LAN (STB command). *SR-LEDH only FIX mode. time is faster about 1.5sec than normal when measuring same kind of object in succession. * SR-LEDW, SR-LEDH only. The SR-NIR can measure spectral distribution in near infrared range (600-1030nm)with high accuracy. Combine with SR series for visible light, Spectral distribution can be measured from visible to near infrared range(380-1030nm). No need of warm-up after power on. Measuring field:2 Luminance of object to be measured is 1cd/m 2 or above. Improvement of chromaticity accuracy. Chromaticity:dx,dy:±0.0013 (for standard illuminant A) *SR-UL2s only 2

The SR-NIR achieves high accuracy measurement of very faint Near infrared. reliability The SR series spectroradiometer is built-in spectroscope and measure spectral radiance of each wavelength from 380 to 780nm. And luminance, chromaticity, other color data is output using color matching function. Other measuring instruments can be calibrated using the result data of SR series as reference. Note: except Near infrared spectroradiometer SR-NIR. Near infrared spectroradiometer Ultra-high speed measurement mode e.g.) SR-UL1R (Measuring angle 1 ) 600 to 1030 nm Standard Illuminant A: 0.1cd/m 2 Standard Illuminant A: 10cd/m2 248s 6.9s 4.3s 98% Decrease 62% Decrease 16.7s 60s 3.8s 3.1s 2.6s Normal HighSpeed HighSpeed2 HighSpeed3 Normal HighSpeed HighSpeed2 HighSpeed3 Normal HighSpeed HighSpeed 2 HighSpeed 3 Approx 1 to 248sec. / * Approx 1 to 31sec. Approx 1 to 17sec. Approx 1 to 60sec. / * Approx 1 to 10sec. Approx 1 to 6sec. 0.1 to 300,000 cd/m 2 Applicable model: Spectroradiometer SR-LEDW, SR-UL2,SR-UL1R, SR-3AR The measurement time differs depending on the measurement target. *SR-3AR only CIE170-2:2015 Color Matching Function This color matching function is using cone fundamentals for the Fundamental Chromaticity Diagram with Physiological Axes which was released in 2006. Visual color difference is obtained the result less than CIE 1931 in the field of OLED, QD, BT2020 with laser, wide color gamut display of HDR and general lighting. 2 degree viewing angle : High color gamut Display etc. 10 degree viewing angle : General Illumination etc. 1.7mm 8.8mm 50cm 50cm CIE 170-2:2015 Color matching function (2 degree viewing angle) CIE 170-2:2015 Chromaticity Diagram (2 degree viewing angle) 2.0 1.5 xf(λ) yf(λ) zf(λ) x(λ) y(λ) z(λ) CIE 1931 CIE 170-2 0.80 0.70 0.60 0.50 CIE 1931 Available to change field of view(2 degree or 10 degree) and CIE(1931 or 170-2) using application software named CS-900A that is standard accessory. 1.0 0.5 y 0.40 0.30 0.20 *Even if chromaticity is same due to difference of color range in chromaticity diagram, color tones are different in CIE1931 and CIE170. 0.10 0.0 380 480 580 680 780 0 0.10 0.20 0.30 0.40 0.50 0.60 0.70 X 3

Provides high accuracy of spectrophotometry per 1 nm and a host of calculation features. Usage SR-LEDW / SR-LEDH / SR-UL2s / SR-UL2 / SR-UL1R / SR-3AR Large Television Car Navigation Monitor of mobile phone Speed meter in automobile LED Traffic signal Head lamp Next-generation illumination Optical characteristic evaluation of Flat Panel Display(LCD,OLED,QD,LD), Fluorescent material, Large Television, Mobile phone, Automobile (Component, Interior panel and various type of lamp), Indicator (Large Panel LED, Traffic light, mobile phone), Parts for display (LCD module, LED and Optical filter), Material (Back light, Fluorescent material, Optical filter, Organic EL and LED). SR-NIR For measuring NIR LED illumination of the safety prevention in automobile. For measuring NIR LED illumination of the monitoring camera. For measuring NIR beam coming from remote controller. For measuring emission line of Ne and Ar lamps. For measuring Transmission characteristics in NIR of optical film and lens. For monitoring output of NIR LED of near-infrared range Other near-infrared measurement. Color Systems Display of Calculation Results Computing common with SR-LEDW / SR-LED / SR-UL2 / SR-UL1R / SR-3AR Not only spectral distribution but also chromaticity, Tristimulus value, luminance and correlated color temperature can be determined by calculation immediately. Tristimulus value X,Y,Z, at 10 degree observers can be determined also. Luminance / Chromaticity mode (Lv, x,y) Radiance / Luminance mode (Le, Lv) Correlated color temperature / Deviation mode (Tc, duv, Lv) MeasuringNo. mode Absolute value The current measuring field Chromaticity Chromaticity Luminance The current color matching function type No entry: CIE 1931 C : CIE 170-2 Measuring angle status when Correction factor displayed data was measured No entry : No correction factor is valid [ f1 ] : Spectral correction factor is valid [ fx ] : XYZ correction factor is valid [ ff ] : both of spectral and XYZ correction factor are valid Tristimulus value mode (XYZ) Luminance / Chromaticity mode (Lv, u,v ) Block diagram Telescopic system makes it possible to measure the absolute value of the spectral radiance of light sources or objects without coming in contact with them. This optics also make it possible to verify the object to measure through a finder. Objective lens Relay lens Light guide Relay lens Finder shutter Eyepiece Diffraction grating View field Measuring spot Object Aperture mirror Imaging lens AC Adapter DC-DC power supply CPU A/D converter USB/RS-232C Interface LCD Display Operation keys External sync input connector CCD Analogue PCB 4

Standard accessory software can control Spectroradiometer and can process measured data with simple operation. Colorimetry software CS-900A (Standard accessory) Color Rendering Index data Colorimetry data Spectral radiance data / Spectral irradiance data peak wavelength Time line graph conditions / Note Spectral radiance Chromaticity diagram xy diagram u'v' diagram a*b* diagram u*v* diagram Hue-chroma diagram The CS-900A for Windows can control the SR series and collect, save, and, graph measured data. The measurement time can be shortened by selecting Colorimetry mode. In Colorimetry mode, the instrument will omit spectral radiance data and send the measured data of luminance, chromaticity, and color temperature. ANSI C78.377 * Judging the unevenness of LED color, classifying LED color into ANSI rank, and judging whether or not measured color data fall within certain rank. * You can specify area in the color diagram and CS-900A judge whether or not color data fall within the area. Total luminous flux measuring function SR series mounted to Integrating sphere, CS-900A has a function to calculate Total luminous flux from SR series measured data. * Integrating sphere, standard light, Auxiliary light, and adapter for SR series should be purchased by customer. Color rendering index (CRI) Color rendering index is measure of how well light source render the color of object compared to reference light source. Ideal light source for CRI is rated as 100. Light sources with a high CRI are desirable. The lower the CRI rating, the less accurately colors will be reproduced. test color samples Evaluation for Accessible design Age-related luminance contrast, which is used in illumination and visual display design, can be evaluated complying with JIS S 0031. Evaluation items (1).Contrast ratio CR (2).Weber ratio Cw (3).Michelson contrast Cm Evaluation based on Photopic and Scotopic are also available when entering their sensitivity data into software. No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 No.10 No.11 No.12 No.13 No.14 No.15 red yellow green blue Skin Color Leaf green Asian Skin Color 10-19 years old 40-49 years old 70-79 years old This new Color Matching Function is corresponded to the latest CIE 170-2:2015 technical report. Display Color system Function Mode Condition setting Evaluation : Spectral radiance graph, other graph : L, xy, XYZ, Spectral radiance, u'v', u*v*, L*a*b*, Color temperature, Deviation, Dominant wavelength, Excitation purity, Color Rendering Index : Fundamental operations of Spectral data : Spectral mode, Colorimetry mode : Auto/Frequency/Integral time, Integ. delay mode, speed, angle, Average, Single / Interval / Continue : CIE standard observer, Light source, Color Rendering Index Hardware requirement OS CPU HDD Memory Port : Windows 7 Ultimate / Professional (32bit/64bit) Windows 8.1 Pro or more (32bit/64bit) Windows 10 Pro or more (32bit/64bit) : Intel Core i3 2.4GHz or more *In the 64bit, the CS-900A support and 64 only. : 1GB or more : 1GB or more : USB 2.0 (1pce), RS-232C serial port *use inter-link RS-232C cable for DOS/V 5

Specification SR-LEDW SR-LEDW-5N Optical system SR-LEDH SR-NIR Objective lens: f= 82 mm F2.5, Eyepiece lens: 5º view field, Diopter adjustment range: ±5diopter Objective lens: f= 82 mm F2.5, Collimation lens:: 5º view field Objective lens: f= 82 mm F2.5, Eyepiece lens: 5º view field, Diopter adjustment range: ±5diopter Diffraction grating Dispersing element Photodetector Electronically cooled linear CCD Measuring angle / / / Electronically cooled back incidence type CCD Electronically cooled linear CCD / / / / collimation only (motor drive) 350 mm to (distance from metallic tip of objective lens) Measuring distance Measuring distance (mm) (distanc e from metallic tip of objective lens) Measuring angle 350 400 500 600 800 1000 2000 10.0 11.7 15.1 18.6 25.4 32.2 66.4 169 4.99 5.84 7.55 9.26 12.7 16.1 33.2 84.4 1.00 1.17 1.51 1.86 2.54 3.22 6.64 16.9 0.50 0.59 0.76 0.93 380nm to 780nm 1.27 1.61 3.32 Measuring diameter (mmø) Wavelength range Spectral accuracy 5nm or less (half width) 8.44 600 to 1030nm ±0.5nm (on Hg emission line) ±0.3nm (on Hg emission line) Spectral band width 5000 5 to 8nm (half width) 6 to 9nm (half width) 5 to 8nm (half width) Wavelength resolution 1nm mode Auto / Manual (integral time / frequency), FIX Auto/manual (integral time/frequency), external vertical sync signal input Auto / Manual (integral time / frequency), synchronous, FIX(INTEG / FREQ) Spectral radiance (W, sr -1, m -2, nm -1) Measuring object Radiance (Le: W, sr -1, m -2), luminance (Lv: cd, m -2), Calculation function - CIE1931 chromaticity coordinates xy, CIE1976 chromaticity coordinates u'v', tristimulu s value XYZ Correlated color temperature (Tc: K) and deviation (duv), CIE standard observer /10º Repeatability with in ±7% Luminance : ±2% Chromaticity(x,y) : ±0.002 (for standard illuminant A) (600 to 1030nm for Topcon Standard light) 1.5% (0.0005 to 0.005 cd/m2) Luminance *1 Repeatability 0.3%(0.1 cd/m2 or more) 2% or less 0.005(0.0005 to 0.005 cd/m2) (600 to 1030nm for Topcon Standard light) Chromaticity 0.0015(0.005 to 0.1 cd/m2) *2 0.0005(0.1 cd/m2 or more) Luminance range (cd/m2) (for standard illuminant A) *3 0.3% 0.4% (0.005 to 0.1 cd/m2) 0.0005 0.0005 to 1,500,000 10 to 1,500,000 0.5 to 3,000 *4 0.0015 to 4,500,000 30 to 4,500,000 1 to 9,000 *4 0.0375 to 5,000,000-20 to 70,000 *4 0.15 to 2,000,000-100 to 300,000 *4 1.000E-01 - Minimum luminance display Polarization error 5.000E-06 Luminance 1% or less, Spectral radiance 2% or less (400nm to 780nm) Interface Parity: Odd/even/none, Date length: 7/8 bits, Stop bit: 1/2 bits Spectral radiance 5% or less Luminance 1% or less, Spectral radiance 5% or less (400nm to 780nm) RS-232C Baud rate : 9600/19200/38400 bps, RS-232C Baud rate: 4800/9600/19200/38400 bps, Parity : even, Date length : 7 bits, Stop bit : 1 bits, Parity: Odd/even/none, Date length: 7/8 bits, Stop bit: 1/2 bits RS-232C Baud rate: 4800/9600/19200/38400 bps, LAN : TCP/IP, Ethernet 10/100BASE-TX USB : USB2.0 USB : USB2.0 Provided AC adapter AC100V-240V, 50/60Hz, DC12V Power supply Power consumption Operating conditions Approx.36W Approx.33W Approx.36W Temperature : 5ºC to 30ºC Temperature : 5ºC to 35ºC Temperature : 5ºC to 35ºC Humidity: 80%R.H. and below (No condensation) External dimensions About 406 mm x 150 mm x 239 mm (L x W x D) Weight About 5.5 kg (main unit only) About 413 mm x 98 mm x 231.5 mm (L x W x D) About 406 mm x 150 mm x 239 mm (L x W x D) About 5.3 kg (main unit only) About 5.5 kg (main unit only) * 1: 2σ from 10 times continuous measurement at measuring angle in normal speed mode. * 2: Max value - Min value from 10 times continuous measurement at measuring angle in normal speed mode. * 3: Measurable range in Normal and High speed mode. *4: SR-NIR can not measure quantity of luminance. The value is for reference, when measuring standard illuminant A. *: The measuring distance is the distance from the metallic tip of the objective lens. *: The values in this table are design reference values and may differ somewhat from the actual diameter. Dimensions SR-LEDW / SR-UL2s / SR-UL2 / SR-UL1R / SR-3AR / SR-NIR 150 41.5 272.7 68-92 193 116.5 1/4-20 UNC (Depth: 6) Camera tripod screw (JIS B 7103) 10 10 M49x0.75, Depth: 5 7.7 ø73 ø77 ø51 ø65 70 (238.5) 195.5 1.5 (4) 100.5 9.4 30 136.5 166.5 ø52 39 35 Tool taps (3-M4, Depth: 6) 168 29 SR-LEDH 41.5±3 290.5 44.5-68.5 98 193 46 46 8.5 1/4-20 UNC (Depth: 6) Camera tripod screw (JIS B 7103) 140 ø87 ø51 70 ø47 104.6 203 (270.5) 231.5 ø65 39 C mount 11.5 Tool taps (3-M4, Depth: 6) 168 53 M49x0.75, Depth: 5 Units : mm 6

Specification Optical system Dispersing element Photodetector Measuring angle Measuring distance Measuring angle Measuring diameter (mmø) Wavelength range Spectral accuracy Spectral band width Wavelength resolution mode Measuring object Calculation function Repeatability Repeatability Luminance range (cd/m 2 ) (for standard illuminant A) *3 Luminance *1 Chromaticity *2 Minimum luminance display Polarization error Interface Power supply Power consumption Operating conditions External dimensions Weight 350 10.0 4.99 1.00 0.50 SR-UL2s 400 11.7 5.84 1.17 0.59 *1: 2σ from 10 times continuous measurement at measuring angle in normal speed mode. *2: Max value - Min value from 10 times continuous measurement at measuring angle in normal speed mode. *3: Measurable range in Normal and High speed mode. *: The measuring distance is the distance from the metallic tip of the objective lens. *: The values in this table are design reference values and may differ somewhat from the actual diameter. Objective lens: f= 82 mm F2.5, Eyepiece lens: 5º view field, Diopter adjustment range: ±5diopter Diffraction grating Electronically cooled linear CCD / / / 350 mm to (distance from metallic tip of objective lens) Measuring distance (mm) (distanc e from metallic tip of objective lens) 500 15.1 7.55 1.51 0.76 0.93 1.27 380nm to 780nm ±0.3nm (on Hg emission line) 5 to 8nm (half width) 1nm Auto/manual (integral time/frequency), external vertical sync signal input Spectral radiance (W, sr -1, m -2, nm -1 ) Radiance (Le: W, sr -1, m -2 ), luminance (Lv: cd, m -2 ), CIE1931 chromaticity coordinates xy, CIE1976 chromaticity coordinates u'v', tristimulu s value XYZ Correlated color temperature (Tc: K) and deviation (duv), CIE standard observer /10º Luminance : ±2% Chromaticity(x,y) : ±0.0013 Luminance : ±2% Chromaticity(x,y) : ±0.002 (for standard illuminant A) (for standard illuminant A) 1.5% (0.0005 to 0.005 cd/m 2 ) 0.4% (0.005 to 0.1 cd/m 2 ) 0.3% (0.1 cd/m 2 or more) 0.005 (0.0005 to 0.005 cd/m 2 ) 0.0015 (0.005 to 0.1 cd/m 2 ) 0.0005 (0.1 cd/m 2 or more) 0.0005 to 3,000 0.0015 to 9,000 0.0375 to 70,000 0.15 to300,000 5.000E-06 SR-UL2 600 18.6 9.26 1.86 800 25.4 12.7 2.54 SR-UL1R 1.5% (0.001 to 0.005 cd/m 2 ) 0.4% (0.005 to 0.1 cd/m 2 ) 0.3% (0.1 cd/m 2 or more) 0.005 (0.001 to 0.005 cd/m 2 ) 0.0015 (0.005 to 0.1 cd/m 2 ) 0.0005 (0.1 cd/m 2 or more) 0.001 to 3,000 0.003 to 9,000 0.075 to 70,000 0.3 to 300,000 1.000E-05 Luminance 1% or less, Spectral radiance 2% or less (400nm to 780nm) RS-232C Baud rate: 4800/9600/19200/38400 bps, Parity: Odd/even/none, Date length: 7/8 bits, Stop bit: 1/2 bits USB : USB2.0 Provided AC adapter AC100V-240V, 50/60Hz, DC12V Approx.36W Temperature : 5ºC to 30ºC Humidity: 80%R.H. and below (No condensation) About 406 mm x 150 mm x 239 mm (L x W x D) About 5.5 kg (main unit only) 1000 32.2 16.1 3.22 1.61 2000 66.4 33.2 6.64 3.32 SR-3AR 0.3% 0.0005 0.1 to 3,000 0.3 to 9,000 7.5 to 70,000 30 to 300,000 1.000E-03 5000 169 84.4 16.9 8.44 NORMAL SPEED MODE: About 1 to 31seconds. HIGH SPEED MODE: About 1 to 17seconds. (excludes communication time with computer) Approx.34W Temperature : 5ºC to 35ºC System Diagram 1/2-inch CCD camera (*) ITV adapter IA-2 White standard board WS-3 ND Filter (10X, 100X set) Attachment Lens AL-6, AL-11,AL-12 Fiber probe FP-3 Illuminance adapter ZV-30 AC adapter (Standard accessory) 顕微鏡 アダプタ AL-4 RS-232C Interlink cable (*) LAN(10/100BASE-TX) cable(*) USB cable (Standard accessory) 顕微鏡対物レンズ ( ) Personal computer (*) Fine Adjustment tripod head S-4 Tripod 5N Tripod head (included in Tripod 5N) Tripod Tripod-SR Colorimetry program CS-900A for SR-LEDW / SR-LEDH / SR-UL2s / SR-UL2 / SR-UL1R / SR-3AR / SR-NIR ->RS-232C / USB SDK-Sample program for SR-LEDH ->RS-232C / LAN (Standard accessory) Colorimetry program CS-900A (Standard accessory) * : Commercial model 7

Optional accessories (Specifications for Measuring Small Objects) angle area (Diameter mmø) Attachment lens 3 sets AL-6 / AL-11 / AL-12 These lenses make focal length shorten and make measurement area shrink. AL-6 distance 51.72 to 68.53mm 2.00 to 2.88 1.00 to 1.44 0.20 to 0.29 0.10 to 0.14 AL-11 distance 19.56 to 24.80mm 1.18 to 1.53 0.59 to 0.76 0.15 to 0.19 0.06 to 0.08 * distance may differ slightly depending on aperture mirror machining accuracy. * distance is from metal tip of attachment lens to the object. AL-12 distance 165 to 197mm 3.23 to 4.00 1.62 to 2.00 0.32 to 0.40 0.16 to 0.20 Fiber probe FP-3P Light guide used for remote detection of light from measurement object. Effective measurement angle: diameter: 3 to 10 mmø distance: 31.0 to 84.9 mm Fiber length: Approx.1m Reference White Board WS-3 Used for measurement of object color or light source with directionality. Luminance factor : 90% or above (for measurement parameters of 0º incidence and 45º observation) Material: Barium sulfate (BaSO4) Dimensions: 78 mm, t = 12.5 mm Effective white surface: 40 mm (at center) CCD Adapter IA-2 Adapter for connecting instrument to the CCD camera. (C mount, 1/2 size) ND filter (10x / 100x set) Neutral density filter for measuring higher luminance than the measuring range of instrument. Tripod 5N Simplifies collimation of measurement object. Max height : 1835mm Min height : 585mm Folder length : 810mm Leg sections : 3 Weight : 4.81Kg (including Tripod stand) Fine Adjustment Stand S-4 Simplifies vertical and lateral collimation. Elevation angle : 40º Depression angle : 80º Rotation : 360º Weight : Approx. 1.7Kg Tripod Tripod-SR Simplifies collimation with smooth movement. Max height : 1614mm Min height : 234mm Folder length : 694mm Leg sections : 3 Weight : 3.0Kg (including Tripod stand) The adapter for microscope: AL-4 AL-4 is for connecting between the lens for microscope and objective lens of instrument. It is possible to measure very small area using the lens for microscope. Illuminance adapter (Cosine receptor) for SR-series ZV-30 Complying with JIS C1609-1:2006 AA class The spectral irradiance and illuminance may be measured by attaching an illuminance adapter to the Spectroradiometer. *Calibration of your Spectroradiometer and Illuminance adapter is required in Topcon factory before you use the illuminance adapter with your instrument. For measuring illuminance, chromaticity, color temperature, and color rendering index of light from LED, OLED illumination. For measuring illuminance of light from projector. range 0.001 to 30,000,000 lx (SR-LEDW at measuring angle with ZV-30) 0.02 to 60,000 lx (SR-UL1R at measuring angle with ZV-30) 6 to 7,000,000 lx (SR-ULR at measuring angle with ZV-30) 2 to 60,000 lx (SR-3AR at measuring angle with ZV-30) 600 to 7,000,000 lx (SR-3AR at measuring angle with ZV-30) Accuracy Ev : ±2%, xy : ±0.002 (for standard illuminant A) SR-LEDW / SR-UL2s / SR-UL2 / SR-UL1R / SR-3AR / SR-NIR Standard package Main body...1ea. AC adapter...1ea. Carrying case...1ea. CD-ROM (Colorimetry software CS-900A / CS-900A CF Tool / Instruction manual)...1ea. Quick manual...1ea. USB cable...1ea. Objective lens cap...1ea. SR-LEDH Standard package Main body...1ea. AC adapter...1ea. CD-ROM (Colorimetry software CS-900A / CS-900A CF Tool / Instruction manual)...1ea. Objective lens cap...1ea. *Some screens are simulated. *The specifications and external appearances of product in this catalogue may be changed without prior notice due to improvements. *The catalogue includes products that are sold separately. *The actual color of products may differ slightly from the catalogue due to lighting and printing conditions. 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580 JAPAN Phone: +81-3-3558-2666 Fax: +81-3-3558-4661 E-mail: techno-info@topcon.co.jp SAFETY PRECAUTIONS Make sure to carefully read the "Manual" to ensure that you use the product properly and safely. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. For more information please visit our website. http://www.topcon-techno.co.jp/en/ 2009 TOPCON TECHNOHOUSE CORPORATION Printed in Japan 2017 12 9