MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements

Similar documents
MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements

MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS

USB-UT350(T) Portable Ultrasonic Pulser/Receiver and Analog to Digital Converter. User s Guide

Description of a device and software for precise sound velocity measurement

Technical Datasheet UltraScope USB

Guide to OPKUD and OPBOX Ultrasonic testing units Software Revision 3.0 / 2003

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Advanced Test Equipment Rentals ATEC (2832)

Instrumentation for High-Power Ultrasonic Applications

Basic functions of the universal flaw detector GEKKO

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Rapid. Simplicity Capability Reliability

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

Fast, portable, user-friendly...the complete C-scan solution.

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

Development and Application of 500MSPS Digitizer for High Resolution Ultrasonic Measurements

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

Fast, portable, user-friendly...the complete C-scan solution.

S.K.Lalwani 1,a, G.D.Randale 1, V.H.Patankar 1, J.L.Singh 2, P.Jyothi 1, A.A.Agashe 1, R.K.Jain 1 and T.S.Ananthakrishnan 1

SUPPERIOR MODERN PERFORMANCE

Digital Ultrasonic Flaw Detector

Digital Ultrasonic Flaw Detector

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

GFT Channel Digital Delay Generator

GFT1504 4/8/10 channel Delay Generator

Multiple Instrument Station Module

Agilent ESA-L Series Spectrum Analyzers

FFT 3010 EMI TEST RECEIVER

ISONIC Superior Performance Portable Smart All-In-One Ultrasonic Flaw Detector and Recorder with A-, B-, CB-Scan, and TOFD Functionality

Model 310H Fast 800V Pulse Generator

GFT bit High Speed Digitizer

ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

Technische Spezifikation (Technical Specification)

TS9050/60. microgen. electronics TM FM Modulation and Spectrum Analyser

Model 865 RF / Ultra Low Noise Microwave Signal Generator

High-speed programmable attenuator MAT800

ULTRASCOPE USB, ULTRAWOOD. all the power of a. the palm of your

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

PN9000 PULSED CARRIER MEASUREMENTS

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

Arbitrary/Function Waveform Generators 4075B Series

Portable Multi-Channel Recorder Model DAS240-BAT

Model 855 RF / Microwave Signal Generator

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

DG5000 series Waveform Generators

Specification RIGOL. 6 Specification

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

WaveStation Function/Arbitrary Waveform Generators

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Keysight Technologies N9320B RF Spectrum Analyzer

WaveStation Function/Arbitrary Waveform Generators

TG1010A AIM & THURLBY THANDAR INSTRUMENTS. 10MHz programmable DDS function generator. Direct Digital Synthesis

Agilent N9320B RF Spectrum Analyzer

radar target generator RTG

DDA55 DISCONTINUOUS DISTURBANCES ANALYSER

HMC-T2240. Synthesized Signal Generator, 10 MHz to 40 GHz

Willtek. Handheld Spectrum Analyzer

Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0) Fax:++972-(0)

Audio Analyzer R&S UPV. Up to the limits

DSA700 Series Spectrum Analyzer

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

ArbStudio Arbitrary Waveform Generators

Models 296 and 295 combine sophisticated

Arbitrary/Function Generator AFG1000 Series Datasheet

DAB+ Voice Break-In Solution

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Agilent 81180A Arbitrary Waveform Generator

WaveStation Function/Arbitrary Waveform Generators

SonaFlex. Set of Portable Multifunctional Equipment for Non-contact Ultrasonic Examination of Materials

Function/Arbitrary Waveform Generator

AV3672 Series Vector Network Analyzer

Instrument. Specifications OR34/35. SmartRouter. 2 to 8 Channels Multi-Analyzers. Controller Unit TECHNICAL SPECIFICATIONS

9200 Series, 300 MHz Programmable Pulse Generator

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

GFT1012 2/4 Channel Precise Slave Generator

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

R-1550A TEMPEST WIDE RANGE RECEIVER. R-1550A TEMPEST Wide Range Receiver

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

Function/Arbitrary Waveform Generator

Ultrasonic Multiplexer OPMUX v12.0

Spectrum Analyzer R&S FS300

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

RF Signal Generator SM300

2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit

Model 845-M Low Noise Synthesizer

Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel. Portable Ultrasonic Phased Array Flaw Detector and Recorder

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

MODEL745 FOUR CHANNEL DIGITAL DELAY/ PULSE GENERATOR

Function/Arbitrary Waveform Generator

ULTRASONIC FLAW DETECTOR +TOFD VERSION. CE MARKING EN Compliant

GATE & DRAIN Probe heads specifications

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

Transcription:

MFD900 The most industrial ultrasonic test system for flaw detection and thickness measurements Guaranteed the lowest possible down time over many years. Pure ultrasonic testpower for high speed off- line and in line testing * Combines the best of analog and digital techniques * Very easy to use and quick system integration * Local and remote control

MFD900 The only computerized system in the world that keeps working even if its central computer would fail Each MFD900 channel is a complete independent flawdetector / thickness tester with individual outputs, constructed as a plug-in module from the rear of the system. Replacement - if needed - can be done in the field by non specialized personel. The central computer module is also field replaceable in case of service. As the computer section is only used for external communication, for the display and to set up the channels, the individual channels remain operational including their outputs in case the computer section would fail. This guarantees the lowest possible down time over many years.

Contact: Inspection Technology Europe BV Vogelenzangsweg 286 2114CH Vogelenzang. The Netherlands Tel. +31 (0)23 5267975 Fax +31 (0)23 5267977 info@inspection-technology.com www.inspection-technology.com

GENERAL: The MFD900 has been designed for flexibility, ease of use and efficiency. Quick field service possible by its modular design Optimal test results are achieved using a combination of hardware and software techniques to obtain the highest performance in test speed and reliability. The MFD900 can be supplied as a 2 channel system for research, production or C-Scan applications or with 10 module each equipped with a second pulser receiver. It can also be supplied as a multi channel, multiplexed or a combination of both systems for ultrasonic testing up to 30 MHz. Easy integration by direct accessible analog outputs of signal amplitude and dual TOF (thickness) of each channel as well as digital alarm outputs of all gates and alarm conditions. Outputs can be configured to customers requirements Very high power square wave pulsers Very low noise resulting in high sensitivity. Various noise reject filters built in. Directly accessible I/O module. User defined input /output to control external alarms, auxiliary functions, inputs with switch buttons, PLC in- and outputs etc.

POSSIBLE CONFIGURATIONS: Each single ultrasonic channel can be equipped with a second pulser/receiver module which makes it a dual channel multiplexed unit. Most parameters and gate settings in this multiplexed mode are yet independent for both pulser/receivers which allows a high freedom for various applications. One mainframe of the MFD900 can be equipped with 10 channel modules working in parallel at full prf speed. When each channel is equipped with a second pulser/receiver it contains 20 channels. Optionally it is possible to work with 4 channel multiplexed modules when speed is less important, making it an even more economic system. Applications: Thickness and corrosion inspection. Measuring with contact or immersion transducers ID/OD. Measuring water path from transducer to front wall for dimensional measurements as well as wall thinkness Weldinspection including a couplng check phase of the transducers for 100% reliability. Working with most of customers own transducers. Non couplant testing with airprobes with external probe adapters. Billet testing with large transducers

MFD KEY FEATURES 2 to 20 channels (1 to 10 channels non multiplexed) independent parameter set up on each channel touch screen for ease of operation each channel equipped with 5 flaw gates with analog peak detectors, alarm logic and gated amplifier selective attenuation and gain on each gate one water path meter and one universal thickness meter available on each channel segmented TCG on each channel up to 10 KHz PRF per channel 2 encoder inputs for in line production testing and displaying real time graphics industrial I/O and PLC interface high speed real time analog and alarm output option position programmable paint marker output ethernet and RS232 interface 4 USB connections VGA connection for external monitor available in table top or 19 rack mount version also available in box version for remote applications MFD900 Technical Specification: In general, an MFD 900 system consists of a main frame with PC, display and system controller and 1..10 input plug in boards. Main frame Specification: Supply voltage Supply voltage tolerance Power consumption Dimensions Weight : 90.. 240V (internally selectable) : 190..240V / 80..120V AC 50/60Hz : max. 250W (10 channels installed) : 450 x 270 x 570 mm (WXHXD) 19 inch 6U : 25 kg

PC Section: PC Type Interfaces Disp lay Graphics Keyboard : Lanner LEC7500 : 6 x USB (4externally available) 1 x RS232 2 x Gigabit Ethernet, )1 externally available) DUAL VGA, (1 externally available) : TFT 800 x 600 or 1024 x 768 12,1 inch : Intel Hardware accelerated : External USB Human interface : Surface Acoustic Wave Touch screen and/ or USB mouse : Dedicated 5 knob control panel with alarm indicators Hard disk : 80 GB, 10 GB for operating system Operating system : Windows XP or XP embedded PC Power : 12V @ 4A max System Controller Section: Construction : Plug in board PC Interface : Gigabit Ethernet UDP/IP Protocol with error correction System interface : 16 bits bus for data, 16 bits bus for settings External : 16 Inputs, 16 Outputs (1=dedicated fast alarm output) Encoders : 2, quadrature or clock / direction 4 x resolution in quadrature mode Encoder freq. : 2 MHz maximum Remote I/O : RS485 / High Speed Output Options : Real Time Output unit Trigger : Input / output via BNC with frequency limit, TTL level Pulser / Receiver specification : The MFD900 uses up to 10 dual pulser / receivers. Therefore a maximum of 20 US channels can be installed in the mainframe. Flaw detection is not dependant on software and will continue to work with control software closed.

Power supply Channels Interface Digitizer Sampling Multiplexing TOF Blanking TOF Clock Detector Flaw gates Alarm Alarm filter Interface Gate Trigger : 12V @ 0.8Amax : 2 pulser / receivers : 16 bits data / 16 bits setting with separate buses : 100 MHz 8 bits (150 MHz optional) : Real time with digital peak detectors : 1:2 or 1:1 when 1 channel is used : 2, measuring between IP and IF echo (water path) Measuring between 2 echoes in gate 4 blanking and zero crossing detection (Thickness gauge) : 0.037 mm to 600 mm in 0.02 mm steps @5900m/sec : 50 MHz (TOF1)/ 160 MHz (TOF2) : 5 Digital peak detectors @ 100 MHz (150 MHz optional) : 5, each with peak detector, alarm logic and gated amplifier : OFF, POS, NEG : 1..200 (consecutive alarms) : Via dedicated interface gate : OFF, IP/IF/ARTIF Receiver specifications (A / B receiver) Channels : 2 Connectors : BNC Gain control : -10.. +90 db Bandwidth : 100 KHz.. 30MHz (-6/-6 db) Filters : HPF (Off, 1MHz, 2.5MHz, 5MHz) @ 12dB/oct BPF (Off, 1MHz, 2.25MHz, 5MHz, 7.5MHz, 10MHz 15MHz, 25MHz) 100% bandwidth LPF (Off, 5MHz, 10MHz, 20MHz) 24dB/oct Output : RF, HW-, HW+, FW, FW+F1, FW+F2, Fw+ F3 Input impedance : 50 Ohm / 1 kohm selectable in through transmission modes Linearity : Better than 1% of full scale Eq. Input Noise : 50uV RMS (10KHz.. 50MHz) Gated Gain : -20.. +20dB TCG Type : Segmented with 18 segments Control Range : -20.. +50 db

Trigger Time range Point Entry : OFF, IP/IF/ARTIF : 0.1.. 500 us in 10 ns steps : Direct entry as gain/position pairs or interactive via on screen display Pulser Specifications (A/B Pulser) Output : Negative Square wave Connector : BNC Width : 25.. 500 ns adjustable in 1 ns steps Voltage : -50..-350 V Fall time : < 5 ns (-200V pulse) Rise time : <10 ns (Damping 50 Ohm, no load, -200V pulse) Impedance : <3 Ohm Repetition Rate : max 10 khz, adjustable per pulser Damping Range : 25.. 315 Ohm in 5 Ohm steps Modes : PE, Dual, Through transmission MFD900 pulser receiver module. Supplied as single channel or dual multiplexed channel Sequencer configuration possible for puls-echo channels and/or through transmission

New high speed version for rotating UT pipe/bar inspections Preliminary specification for RotaEcho v13 Pulser / Receiver Type : PRU922 dual channel parallel pulser / receiver Gain Range : -10 + 90 db Gain resolution : 0.1 db/step Gain accuracy : +/- 0.5 db High Pass Filters : OFF, 1 MHz, 2.5 MHz, 10 MHz, 12 db/oct Low, Pass Filters : OFF, 5 MHz, 10 MHz, 20 MHz, 24 db/oct Frequency range : 500 khz 35 MHz (Filters off, -3 db) Reject : Linear 0 50 % Output : RF, Neg. Halfwave, Pos. Halfwave, FullWave, Filt 1,2,3 Pulser Type : Negative squarewave Fall time : < 6 ns Impedance : < 5 Ohm Termination : 50 Ohm / 300 Ohm Mode : Pulse/echo Pulse width : 25 350 ns in 1 ns increments Pulse voltage : -50-300V Pulse repetition freq. : max 20 khz per channel (PRF) Pulse delay from trigger : 0.05 160 us in 50 ns steps Synchronisation : Internal, encoder 1, encoder 2, external (Rear input) Channels : max 13 PRU922 boards = 26 channels per unit Gates Flaw gates : 4 Output : 0..100 % in 1 % steps, alarm Alarm mode : OFF, Pos., Neg. Alarm Filter : 1 200 consecutive alarms before output activates Delay : 10 65000 ns (can be limited by PRF) Range : 10 65000 ns (can be limited by PRF) Trigger : OFF, IP, IF, Artificial Gain control : -20 +20dB for echo within gate Interface Gate Alarm mode Alarm Filter Delay Range Trigger Gain control : OFF, Pos., Neg. : 1 200 consecutive alarms before output activates : 10 65000 ns (can be limited by PRF) : 10 65000 ns (can be limited by PRF) : OFF, IP, IF, Artificial : -20 +20dB for echo within gate Scope (A scan display) Range Delay Velocity Sample rate Display mode ADC Running mode : 100 65000 ns : 100 65000 ns : IP, IF, Artificial : 100 MHz across full range : Running, peak catch : 8 bit / 200 MHz, 1 per channel : Trigger or locked to rotary position Wall thickness Resolution : 2 ns, single shot, 0.008 mm steel Averaging : 1 200 Mode : 2 echoes in gate 4 Min wall thickness : 0.2 mm (depending on signal quality) Blanking range : 10 65000 ns Alarms : max / min Dimension measurement Resolution ID/OD Count clock Mode Averaging Temperature compensation Ovality alarm Alarms Eccentricity Calibration : 1.5 um, 3, 6, 12 um (depending on water path) : 500, 250, 125, 62.5 MHz : 2 opposite channels : 1 200 measurements : continuous, using reference channel : 0 20 % in 0.001 % steps, updated per rotation : Ovality, max, min diameter excursion, eccentricity : 0.005 mm resolution single shot : Using reference pipe

Edge suppression Front edge Rear edge Resolution : 0 100 mm : 0 100 mm : 1 mm Miscellaneous Tracker system Markers Alarm outputs Position Resolution Mode Synchronization Length calibration Sorter control : max 4, output selectable per marker on Flaw 1, flaw 2, Wall, dimension alarms : 1 for horn, adjustable dwell time, driven directly from hardware : adjustable 10 8100 mm from start sensor : 1 mm : forward / reverse : encoder with programmable resolution : using two sensors at known distance or V roller calculation : Optional Rotation Readout Signal Artificial RPM : 0 20000 RPM, direct update : sensor with NPN normally closed output : 0 3000 RPM, used when rota is stopped Computer PC : Lanner LEC 7900 or equivalent UT interface : 1 Gigabit network, single cable between UT system and PC, no plug in cards Data logging : User configurable graphs for Flaw, Wall, ID/OD, synchronised to transport using encoder Instrument setups : 1000 Database : Internal / external database, running either on instrument or on remote computer via TCP/IP link Stores inspection data, setups. Ability to reload setup from database. Programmable fields, remote backup / restore using fileserver. Operating system : Windows XP or 7 Speed : 2.2 GHz dual core or better RotaEcho main frame Enclosure : 6 HE 19 inch (rack mount) with built in touch screen monitor and 5 smart knobs or 3 HE (rack mount) unit for use with remote PC. Input voltage range : 90.. 240 VAC, 50 / 60 Hz Power consumption : max. 300W (26 channels full PRF) Weight : 22 26 kg depending on number of PRU922 s installed Dimensions : 266 x 449 x 439 mm (h x w x d) excl. rack mount adapters and / or front handles Front panel connections : 2 x USB Rear panel connections : 4 x USB, 2 x Ethernet, RS 232 and VGA. Rear system ctl conn. : Sync. I/O, RS485, encoders, control inputs, alarm outputs Specifications can be changed without notification.