Product Manual 5202 Pulse isolator

Similar documents
PRetrans Table of contents

Product Manual 3186A: 2-wire transmitter isolator 3186B: 2-wire current isolator

Product manual 3000 series 6 mm series of temperature converters

Temperature Input Module for Zone 1 Series 9482/32

Product manual wire programmable RTD transmitter

5000 series Signal Isolation

Isolators & converters

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

User s Guide DRST-FR. Programmable Converter. Shop online at omega.com. For latest product manuals:

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Power supply CP-D 24/4.2 Primary switch mode power supply

Digital Input Output Module for Zone 1 Series 9470/32

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Digital Input Output Module for Zone 2 Series 9470/33

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

User and Safety Manual ProLine P224xx P1

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1.

Power supply CP-E 24/20.0

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

Technical Data. General specifications. Rated operating distance s n 3 mm

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

RMA42. Technical Information

Power supply CP-E 24/2.5

A6500-UM Universal Measurement Card

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

Product Guide. universal. isolation. i.s. interface. temperature. display

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Power supply CP-D 24/1.3

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Thermocouple - Transducer

MINI MCR-SL-UI-I-LP-NC

Power supply CP-D 12/2.1

Isolators A3/1. Vibration Transducer Supply Unit Series

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Inductive sensor slot-type SI2-K08-AP7

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Technical Information RMA42

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

FC Series Signal Conditioners

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

MINI MCR-SL-UI-f(-SP)

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/0.75

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

MODEL: M2DYS SEN TRONIC AG

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

RSMFX-2R MULTIFUNCTIONAL

External brake resistor AX2090-BW5x

Power supply CP-E 24/2.5

QUINT-PS/ 3AC/24DC/10

Rail mounted Temperature Transmitter TH102/TH102-Ex

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

SINEAX B 811 Power Pack with additional Functions

For detailed specifications and ordering info go to

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

OPTITEMP TT 10 C/R Technical Datasheet

AC 3. Active Antenna Combiner. Instruction manual

Binary Output Series 9175

Single-Channel Safety Barriers Series 9001

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

3TK28 Safety Relays. General data. 7/70 Siemens LV

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

OPTITEMP TT 20 Technical Datasheet

Preset counters, electronic

Isolating Repeater Input Series 9163

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

MACX MCR-UI-UI-UP(-SP)(-NC)

Your Global Automation Partner. IMX12-DI01 Isolating Switching Amplifier. Safety Manual

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

NI PXI-2520 Specifications 80-Channel SPST Relay Module

Product Manual wire HART transmitter

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Temperature transmitter itemp PCP DIN rail TMT 121

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Transcription:

Product Manual 50 Pulse isolator PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 50V108-UK From serial no.: 030481661

6 Product Pillars to meet your every need Individually outstanding, unrivalled in combination With our innovative, patented technologies, we make signal conditioning smarter and simpler. Our portfolio is composed of six product areas, where we offer a wide range of analog and digital devices covering over a thousand applications in industrial and factory automation. All our products comply with or surpass the highest industry standards, ensuring reliability in even the harshest of environments and have a 5-year warranty for greater peace of mind. Our range of temperature transmitters and sensors provides the highest level of signal integrity from the measurement point to your control system. You can convert industrial process temperature signals to analog, bus or digital communications using a highly reliable point-to-point solution with a fast response time, automatic selfcalibration, sensor error detection, low drift, and top EMC performance in any environment. We deliver the safest signals by validating our products against the toughest safety standards. Through our commitment to innovation, we have made pioneering achievements in developing I.S. interfaces with SIL Full Assessment that are both efficient and cost-effective. Our comprehensive range of analog and digital intrinsically safe isolation barriers offers multifunctional inputs and outputs, making PR an easy-to-implement site standard. Our backplanes further simplify large installations and provide seamless integration to standard DCS systems. We provide inexpensive, easy-to-use, future-ready communication interfaces that can access your PR installed base of products. All the interfaces are detachable, have a built-in display for readout of process values and diagnostics, and can be configured via push-buttons. Product specific functionality includes communication via Modbus and Bluetooth and remote access using our PR Process Supervisor (PPS) application, available for ios and Android. Our unique range of single devices covering multiple applications is easily deployable as your site standard. Having one variant that applies to a broad range of applications can reduce your installation time and training, and greatly simplify spare parts management at your facilities. Our devices are designed for long-term signal accuracy, low power consumption, immunity to electrical noise and simple programming. Our compact, fast, high-quality 6 mm isolators are based on microprocessor technology to provide exceptional performance and EMC-immunity for dedicated applications at a very low total cost of ownership. They can be stacked both vertically and horizontally with no air gap separation between units required. Our display range is characterized by its flexibility and stability. The devices meet nearly every demand for display readout of process signals, and have universal input and power supply capabilities. They provide a real-time measurement of your process value no matter the industry, and are engineered to provide a user-friendly and reliable relay of information, even in demanding environments.

Pulse isolator 50 Contents Warning... Symbol identification... Safety instructions... 3 How to demount system 5000... 4 Applications... 5 Technical characteristics... 5 Mounting / installation... 5 Applications... 6 Order... 7 Electrical specifications... 7 Jumper programming... 9 Function description... 9 Block diagram: 50A1 and 50A... 10 Block diagram: 50A4... 10 Block diagram: 50B1 and 50B... 11 Block diagram: 50B4... 11 Connections... 1 UL Control Drawing 50QU01... 13 Document history... 14 50V108-UK 1

GENERAL Warning This device is designed for connection to hazardous electric voltages. Ignoring this warning can result in severe personal injury or mechanical damage. To avoid the risk of electric shock and fire, the safety instructions of this manual must be observed and the guidelines followed. The specifications must not be exceeded, and the device must only be applied as described in the following. Prior to the commissioning of the device, this manual must be examined carefully. Only qualified personnel (technicians) should install this device. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. HAZARD- OUS VOLTAGE Warning Until the device is fixed, do not connect hazardous voltages to the device. The following operations should only be carried out on a disconnected device and under ESD-safe conditions: Dismantlement of the device for setting of DIP-switches and jumpers. General mounting, connection and disconnection of wires. Troubleshooting the device. Repair of the device replacement of circuit breakers must be done by PR electronics A/S only. Warning 50B4: To keep the safety distances, one relay must not be connected to hazardous voltage at the same time as the other relay on the same channel is connected to non-hazardous voltage. INSTAL- LATION Symbol identification Triangle with an exclamation mark: Warning / demand. Potentially lethal situations. The CE mark proves the compliance of the device with the essential requirements of the directives. The double insulation symbol shows that the device is protected by double or reinforced insulation. Ex devices have been approved according to the ATEX directive for use in connection with installations in explosive areas. 50V108-UK

Definitions Safety instructions Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and 50 to 1000 Volt AC. Technicians are qualified persons educated or trained to mount, operate, and also trouble-shoot technically correct and in accordance with safety regulations. Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal operation. Receipt and unpacking Unpack the device without damaging it and check whether the device type corresponds to the one ordered. The packing should always follow the device until this has been permanently mounted. Environment Avoid direct sun light, dust, high temperatures, mechanical vibrations and shock, and rain and heavy moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation. All devices fall under Installation Category II, Pollution Degree 1, and Insulation Class II. Mounting Only technicians, who are familiar with the technical terms, warnings, and instructions in the manual and who are able to follow these, should connect the device. Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively, PR electronics A/S www.prelectronics.com Mounting and connection of the device should comply with national legislation for mounting of electric materials, i.e. wire cross section, protective fuse, and location. Descriptions of input / output and supply connections are shown in the block diagram and on the side label. The following apply to fixed hazardous voltages-connected devices: The max. size of the protective fuse is 10 A and, together with a power switch, it should be easily accessible and close to the device. The power switch should be marked with a label indicating that it will switch off the voltage to the device. Year of manufacture can be taken from the first two digits in the serial number. Calibration and Adjustment During calibration and adjustment, the measuring and connection of external voltages must be carried out according to the specifications of this manual. The technician must use tools and instruments that are safe to use. Normal operation Operators are only allowed to adjust and operate devices that are safely fixed in panels, etc., thus avoiding the danger of personal injury and damage. This means there is no electrical shock hazard, and the device is easily accessible. Cleaning When disconnected, the device may be cleaned with a cloth moistened with distilled water. Liability To the extent the instructions in this manual are not strictly observed, the custom er cannot advance a demand against PR electronics A/S that would otherwise exist according to the concluded sales agreement. 50V108-UK 3

How to demount system 5000 First, remember to demount the connectors with hazardous voltages. Picture 1: The device is detached from the DIN rail by moving the bottom lock down. Picture : Then, by lifting the upper lock and pulling the front plate simultaneously, the PCB is removed. Switches and jumpers can now be adjusted. 4 50V108-UK

Pulse isolator 50 B channels - or 4 outputs 5-port 3.75 kvac galvanic isolation Dual output detection Universal AC or DC supply Applications Pulse isolator for the supply of NAMUR sensors. 50B1, -B and -B4 have a safety barrier for the supply of NAMUR sensors installed in hazardous area. Pulse isolator for the detection of mechanical contacts. 50B1, -B and -B4 have a safety barrier for the detection of mechanical contacts installed in hazardous area. One input signal can be used on two separate outputs. A cable error alarm can be detected on a separate output. Technical characteristics PR50A1, -A, -B1 and -B have relays with change-over contacts or open NPN collectors. For 50B1 and -B these are available in the safe area. PR50A4 and -B4 have 4 SPST relays, which are activated simultaneously two and two. Each relay can be programmed to the function N.O. or N.C. For 50B4 the relays are available in the safe area. Inputs, outputs, and supply are floating and galvanically separated. The 50 is designed according to strict safety requirements and is thus suitable for application in SIL installations. Mounting / installation Mounted vertically or horizontally on a DIN rail. Up to 84 channels per metre can be mounted. 50V108-UK 5

Applications NAMUR sensors Outputs 1 NAMUR sensor outputs Contact with cable error detection Rp Outputs Signal Cable error Contact Output 6 50V108-UK

Order Type Version Output 50 Standard : A Open collector NPN x 1 relay ATEX Ex : B x relays : 1 : : 4 Electrical specifications Environmental conditions: Operating temperature............................... -0 C to +60 C Calibration temperature................................ 0...8 C Relative humidity................................... < 95% RH (non-cond.) Protection degree.................................. IP0 Mechanical specifications: Dimensions (H x W x D)............................... 109 x 3.5 x 130 mm Weight approx..................................... 30 g DIN rail type....................................... DIN 4677 Max. wire size...................................... 1 x.5 mm stranded wire Screw terminal torque................................. 0.5 Nm Common electrical specifications: voltage, universal............................... 1.6...53 VAC, 50...60 Hz or 19...300 VDC Internal consumption, 50A1, -A, -B1 and -B................ 1.5 W ( channels) Max. consumption, 50A1, -A, -B1 and -B.................. 1.5 W ( channels) Internal consumption, 50A4 and -B4......................0 W ( channels) Max. consumption, 50A4 and -B4........................0 W ( channels) Fuse........................................... 400 ma T / 50 VAC Isolation voltage, test / operation.......................... 3.75 kvac / 50 VAC EMC immunity influence......................... < ±0.5% Extended EMC immunity: NAMUR NE 1, A criterion, burst.................... < ±1% Auxiliary voltage: NAMUR supply.................................... Inputs: 8 VDC / 8 ma Sensor types: NAMUR acc. to................................... EN 60947-5-6 Mechanical contact Frequency range.................................... 0...5 khz Pulse length...................................... > 0.1 ms Input resistance.................................... 1 kω Trig level, signal.................................... < 1. ma, >.1 ma Trig level, cable error................................. < 0.1 ma, > 6.5 ma Outputs: Relay outputs: Max. frequency..................................... 0 Hz Max. voltage...................................... 50 VRMS Max. current....................................... A / AC Max. AC power.................................... 100 VA Max. load at 4 VDC.................................. 1 A 50V108-UK 7

Open NPN collector outputs: Max. frequency..................................... 5 khz Pulse length...................................... > 0.1 ms Load, max. current / voltage............................ 80 ma / 30 VDC Voltage drop at 5 ma / 80 ma.......................... < 0.75 VDC / <.5 VDC Ex / I.S. data: Terminal 41...43, (51...53) U m............................................ 50 V U o............................................. 10.6 VDC I o............................................ 13.8 madc P o............................................. 38 mw L o............................................. 160 mh C o............................................. 1.9 µf Observed authority requirements: EMC............................................ 014/30/EU LVD............................................ 014/35/EU ATEX.......................................... 014/34/EU RoHS.......................................... 011/65/EU PELV/SELV........................................ IEC 364-4-41 and EN 6074 Approvals: UL............................................. UL 508 EAC............................................ TR-CU 00/011 I.S. / Ex approvals: ATEX.......................................... DEMKO 99ATEX17186 UL............................................. UL 913 EAC Ex TR-CU 01/011............................... RU C-DK.GB08.V.00410 Functional Safety: Hardware assessed for use in SIL applications FMEDA report - www.prelectronics.com 8 50V108-UK

Jumper programming Signal transmission Channel 1 JP 11 Channel JP 1 detection Channel 1 JP 1 Channel JP Direct ON Inverted OFF Channel 1 signal to channel Channel 1 JP 13 Channel function Channel 1 to channel ON, input disabled Channel JP 3 Signal Channel 1 to channel OFF, input active Relay function Channel 1 Channel 50B4 Relay 1, JP41 Relay, JP4 Relay 1, JP51 Relay, JP5 N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. When a channel 1 signal or cable errors are transmitted to channel, JP must be in position -3, and JP 3 must be in position 1-. Signal transmission to channel : If the channel 1 signal is inverted (JP11 in position -3), the channel signal will also be inverted. In this case, the inversion on channel can be reversed by inverting the channel signal (JP1 in position -3). When channel is used individually, input is activated by JP 3 in position -3. Function description Examples of connections on block diagram (1)...(4) (1) NAMUR sensor with cable error detection in case of cable disconnection or short-circuit. () Mechanical contact with cable error detection in case of cable disconnection or short-circuit, when and Rp are mounted on the contact. (3) Mechanical contact with cable error detection in case of cable disconnection, when Rp is mounted on the contact. (4) Mechanical contact without cable error detection. 50V108-UK 9

Block diagram: 50A1 and 50A (4) NAMUR + CH 1 43 Contact + 4 Rp Rp Input 41 (3) () (1) Rp = 15 kω = 750Ω Power JP1 detection CH1 + CH + JP11 1 Direct 3 Inverted error JP13 1 3 Output 1 11 Open collector output 33 31 13 1 11 4...30 VAC & 4...50 VDC Relay N.C. Relay C. / NPN + Relay N.O. / NPN - (4) NAMUR + 53 Contact + 5 Rp Rp Input 51 (3) () (1) Rp = 15 kω = 750Ω CH CH + CH1 to CH 3 JP3 1 JP detection V+ JP1 1 Direct 3 Inverted Error 50A Output 1 Open collector output 3 1 Relay N.C. Relay C. / NPN + Relay N.O. / NPN - Block diagram: 50A4 (4) Rp Rp (3) () Rp = 15 kω = 750Ω (1) CH 1 43 Contact + 4 Input 41 NAMUR + Power CH1+ CH+ JP11 1 Direct 3 Inverted Error Output Relay 1 Relay JP41 N.O. N.C. 33 31 1 11 14 4...30 VAC & 4...50 VDC Relay Common Relay N.O. / N.C. Relay Common JP1 detection JP13 1 3 JP4 N.O. N.C. 13 Relay N.O. / N.C. (4) Rp Rp (3) () Rp = 15 kω = 750Ω NAMUR + 53 Contact + 5 Input 51 (1) CH CH+ CH1 to CH 3 JP3 1 JP detection JP1 1 Direct 3 Inverted Error 50A4 V+ Output Relay 1 Relay JP51 N.O. N.C. JP5 N.O. N.C. 1 4 3 Relay Common Relay N.O. / N.C. Relay Common Relay N.O. / N.C. 10 50V108-UK

Block diagram: 50B1 and 50B (4) (4) NAMUR + CH 1 43 Contact + 4 Rp Rp Input 41 (3) () (1) Rp = 15 kω = 750Ω NAMUR + 53 Contact + 5 Rp Rp Input 51 (3) () (1) Rp = 15 kω = 750Ω CH Ex barrier Ex barrier CH + power JP1 detection CH1 to CH 3 JP3 1 JP detection JP11 1 Direct 3 Inverted error JP13 1 3 JP1 1 Direct 3 Inverted error 50B CH1 + CH + V+ output output 1 11 Open collector output 1 Open collector output 33 31 13 1 11 3 1 4...30 VAC & 4...50 VDC Relay N.C. Relay C. / NPN + Relay N.O. / NPN - Relay N.C. Relay C. / NPN + Relay N.O. / NPN - Block diagram: 50B4 (4) (4) Rp Rp (3) () Rp = 15 kω = 750Ω Rp Rp (3) () Rp = 15 kω = 750Ω CH 1 NAMUR + 43 Contact + 4 Input 41 (1) NAMUR + 53 Contact + 5 Input 51 (1) CH Ex barrier Ex barrier CH+ Power JP1 detection CH1 à to CH 3 JP3 1 JP detection JP11 1 Direct 3 Inverted Error JP13 1 3 JP1 1 Direct 3 Inverted Error 50B4 CH1+ CH+ V+ Output Relay 1 Relay Output Relay 1 Relay JP41 N.O. N.C. JP4 N.O. N.C. JP51 N.O. N.C. JP5 N.O. N.C. 33 31 1 11 14 13 1 4 3 4...30 VAC & 4...50 VDC Relay Common Relay N.O. / N.C. Relay Common Relay N.O. / N.C. Relay Common Relay N.O. / N.C. Relay Common Relay N.O. / N.C. 50V108-UK 11

Connections : 31 3 33 Channel 1 Channel Channel 1 Channel NAMUR sensor Contact, cable error Contact, cable error 41 4 43 41 4 43 41 4 43 - + Rp NAMUR sensor Contact, cable error Contact, cable error 51 5 53 51 5 53 51 5 53 - + Rp 50A1, -A, -B1 and -B: Open collector, NPN Relay 11 1 13 11 1 13 - + Open collector, NPN 1 3 - + Relay 1 Inputs: Rp = 15 k Ω = 750 Ω to be mounted on contact Rp = 15 k Ω = 750 Ω to be mounted on contact Outputs: 3 Rp Rp Contact 41 4 43 Contact 51 5 53 50A4 and -B4: x Relay N.O. x Relay N.C. 11 1 13 14 11 1 13 14 x Relay N.O. x Relay N.C. 1 3 4 1 3 4 1 50V108-UK

µ µ µ µ 50V108-UK 13

Document history The following list provides notes concerning revisions of this document. Rev. ID Date Notes 108 1510 GOST approval replaced with EAC approval 14 50V108-UK

We are near you, all over the world Our trusted red boxes are supported wherever you are All our devices are backed by expert service and a 5-year warranty. With each product you purchase, you receive personal technical support and guidance, day-to-day delivery, repair without charge within the warranty period and easily accessible documentation. We are headquartered in Denmark, and have offices and authorized partners the world over. We are a local business with a global reach. This means that we are always nearby and know your local markets well. We are committed to your satisfaction and provide PERFORMANCE MADE SMARTER all around the world. For more information on our warranty program, or to meet with a sales representative in your region, visit prelectronics.com.

Benefit today from PERFORMANCE MADE SMARTER PR electronics is the leading technology company specialized in making industrial process control safer, more reliable and more efficient. Since 1974, we have been dedicated to perfecting our core competence of innovating high precision technology with low power consumption. This dedication continues to set new standards for products communicating, monitoring and connecting our customers process measurement points to their process control systems. Our innovative, patented technologies are derived from our extensive R&D facilities and from having a great understanding of our customers needs and processes. We are guided by principles of simplicity, focus, courage and excellence, enabling some of the world s greatest companies to achieve PERFORMANCE MADE SMARTER. www.prelectronics.com