General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

General Specifications

General Specifications

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

General Specifications

General Specifications

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Rosemount 148 Temperature Transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

General Specifications

General Specifications

General Specifications

General Specifications

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

General Specifications

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

General Specifications

DPharp Differential Pressure and Pressure Transmitters

General Specifications

General Specifications

SITRANS T measuring instruments for temperature

General Specifications

General Specifications

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

SMART TEMPERATURE TRANSMITTERS. smar

ThermoPLUS Smart Temperature Transmitter

Smart Pressure Transmitter

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

YTA610 and YTA710 Temperature Transmitters (Hardware)

The Rosemount 848T Wireless Temperature Transmitter

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Head mounted Temperature Transmitter TF02/TF02-Ex

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

YTA610 and YTA710 Temperature Transmitter (Hardware)

Field IT 2600T Series Pressure Transmitters

General Specifications

Rosemount 148 Temperature Transmitter

General Specifications

General Specifications

0 2 1 â Ó. itemp HART TMT182. Technical Information

Rosemount 248 Wireless Temperature Transmitter

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

User's Manual Model SE14 Magnetic Flow Converter

Rosemount 648 Wireless Temperature Transmitter

ABSOLUTE PRESSURE TRANSMITTER

General Specifications

General Specifications

Rosemount 248 Temperature Transmitter

AT9000 Advanced Transmitter Gauge Pressure Transmitters

Rosemount 248 Wireless Temperature Transmitter

Rosemount 248 Temperature Transmitter

General Specifications

AT9000 Advanced Transmitter Gauge Pressure Transmitters

Rosemount 644 Temperature Transmitter

FIELD DEVICES - PRESSURE

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

General Specifications

Alphaline Temperature Transmitters

General Specifications

I/A Series Intelligent Temperature Transmitter Model RTT20 Transmitter with Analog 4 to 20 ma Output, or with FoxCom or HART Communication Protocol

PAD - Heavy Duty Differential Pressure Trasmitter

AT9000 Advanced Transmitter Differential Pressure Transmitters

General Specifications

Absolute Pressure Transmitters

FKG... 5 PRESSURE TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

Rosemount 648 Wireless Temperature Transmitter

General Specifications

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

Transcription:

General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to a to 0 ma DC signal for transmission. The YTA110 supports either BRAIN or HART communication protocol. The YTA110 in it standard configuration is certified by TÜV as complying with SIL for safety requirement. FEATURES High performance Microprocesser-based sensing technology ensures long-term accuracy and high reliability. High reliability Dual-compartment housing realizes high resistance capability to harsh environments, and YTA110 has SIL capability for safety requirement. Variety of sensor inputs The type of sensor input is user-selectable from thermocouples (T/C), RTDs, ohms, or DC milivolts. Digital communication BRAIN or HART communication protocol is available. The insturment configuration can be changed by the user with using the BT00 or HART communicator. Self-diagnostics function Continuous self-diagnostics capability ensures longterm performance and lower cost of ownership. LCD display with bargraph The LCD display provides both a digital readout and percent bargraph simultaneously. STANDARD SPECIFICATIONS PERFORMANCE SPECIFICATIONS Accuracy (A/D accuracy/span + D/A accuracy) or 0.1 % of calibrated span, whichever is greater. See Table 1. on page. Cold Junction Compensation Accuracy (For T/C only) ± 0. C (± 0.9 F) Ambient Temperature Effect (per 10 C change) ± 0.1 % or ± (Temperature Coefficient /span), whichever is greater. See Table. for Temperature Coefficient. Stability RTD: 0.1% of reading or 0.1 C per years, whichever is greater at C. T/C: 0.1% of reading or 0.1 C per year, whichever is greater at C. Year Stability RTD: 0.% of reading or 0. C, whichever is greater at C. T/sC: 0.% of reading or 0. C, whichever is greater at C. RFI Effect Tested per EN 008-, field intensity up to 10 V/m. Power Supply Effect ±0.00 % of calibration span per volt Vibration Effect 10 to 60 Hz 0.1 mm peak displacement 60 to 000 Hz G Position Effect None FUNCTIONAL SPECIFICATIONS Input Input type is selectable: Thermocouples, -, -, and -wire RTDs, ohms and DC milivolts. See Table 1. on page. Span & Range Limits See Table 1. on page. Input signal source resistance (for T/C, mv) 1 k or lower Input lead wire resistance (for RTD, ohm) 10 per wire or lower Output Two wire to 0 ma DC. Output range:.68 ma to 0.8 ma BRAIN or HART protocol is superimposed on the to 0 ma signal. Any single value from the followings can be selected as the analog output signal. Sensor 1, Terminal Temperature. Also, up to three of the above values can be displayed on LCD display or read via communication. Isolation Input/Output/GND isolated to 00 V DC Yokogawa Electric Corporation -9- Nakacho, Musashino-shi, Tokyo, 180-870 Japan Phone: 81---690 Fax.: 81---018 GS 01C0B01-00E Copyright June 1998 1th Edition Feb. 008

Sensor Burnout High (1.6 ma DC) or Low (.6 ma DC), userselectable. Output in Transmitter Failure Up-scale: 110%, 1.6 ma DC or more (Standard or Optional code /C) Down-scale: %,. ma DC or less (Optional code /C1 or /C) Update Time Approximately 0. seconds Turn-on Time Approximately seconds Damping Time Constant Selectable from 0 to 99 seconds Ambient Temperature Limits Option code may affect limits. -0 to 8 C (-0 to 18 F) -0 to 80 C (- to 176 F) with Integral Indicator Ambient Humidity Limits to 100 % RH at 0 C (10 F) EMC Conformity Standards, EN616, AS/NZS CISPR11 SIL Certification YTA110 temperature transmitter is certified by TÜV NORD CERT GmbH in compliance with the following standards; IEC 6108: 000; Part1 to Part 7 Functional Safety of Electrical/electronic/programmable electronic related systems; SIL capability for single transmitter use, SIL capability for dual transmitter use. Self-calibration The analog-to-digital measurement circuitry automatically self-calibrates for temperature update by comparing the dynamic measurement to extremely stable and accurate internal reference elements. Self-diagnostics Loss of input error, ambient temperature error, EEPROM error, and CPU error. Up to four error history can be stored in the memory. Manual Output Function The output value can be set manually. Supply & Load Requirements Supply Voltage 10. to V DC for general use and flameproof type 10. to CV DC for lightning protector (Optional code /A) 10. to 0 V DC for intrinsically safe, Type n, nonincendive, or non-sparking type Minimum voltage limited at 16. V DC for digital communications, BRAIN and HART protocols Load 0 to 1 for operation 0 to 600 for digital communication See Figure 1. on page. Communication Requirements BRAIN: Communication Distance Up to km (1. miles) when using CEV polyethylene-insulated PVC-sheathed cables. Communication distance varies depending on type of cable used. Load Capacitance 0. F or less Load Inductance. mh or less Input Impedance of communicating device 10 k or more at. khz. PHYSICAL SPECIFICATIONS Enclosure Material Low copper cast-aluminum alloy Coating Polyurethan resin baked finish Color: Deep-sea moss green (Munsell 0.6GY.1/.0) Degrees of Protection IP67, NEMAX, JIS C090 immersion proof Data and tag plate SUS0 Stainless steel Mounting Optional mounting brackets can be used either for two-inch pipe or flat panel mounting. Terminal Screws M screws Integral Indicator Optional LCD digital indicator includes -digit numerical dispaly with C, K, F, R, % and mv, 0 to 100 % bargraph and dot-matrix display. Weight 1. kg(.6 lb) without Integral indicator and Mounting bracket. Integral indicator weights 0. kg(0. lb). Electrical Connections Refer to MODEL AND SUFFIX CODES on page. GS 01C0B01-00E Apr. 0, 007-00

Sensor Type Table 1. Sensor type, measurement range, and accuracy. Accuracy Reference Measurement Range Minimum Span Standard (Recommended) Input range A/D Accuracy D/A C F C F C F Accuracy 100 to 00 1 to 7 ±.0 ±. B 100 to 180 1 to 08 00 to 00 7 to 7 ± 1.0 ± 1.8 00 to 180 7 to 08 ± 0.7 ± 1. E -00 to 1000-8 to 18-00 to -0-8 to -8 ± 0. ± 0.6-0 to 1000-8 to 18 ± 0.16 ± 0.9 J -00 to 100-8 to 19-00 to -0-8 to -8 ± 0.0 ± 0.7-0 to 100-8 to 19 ± 0.0 ± 0.6 K -00 to 17-8 to 0-00 to -0-8 to -8 ± 0.0 ± 0.90-0 to 17-8 to 0 ± 0. ± 0. N IEC8-00 to -0-8 to -8 ± 0.80 ± 1. -00 to 100-8 to 7-0 to 100-8 to 7 ± 0. ± 0.6-0 to 0-8 to ± 1.0 ± 1.8 R -0 to 1768-8 to 1 0 to 100 to 1 ± 0.80 ± 1. 100 to 600 1 to 111 ± 0.60 ± 1.08 T/C 600 to 1768 111 to 1 ± 0.0 ± 0.7 C -0 to 0-8 to ± 1.0 ± 1.8 ( F) 0 to 100 to 1 ± 0.80 ± 1. S -0 to 1768-8 to 1 100 to 600 1 to 111 ± 0.60 ± 1.08 600 to 1768 111 to 1 ± 0.0 ± 0.7 T -00 to 00-8 to 7-00 to -0-8 to -8 ± 0. ± 0. -0 to 00-8 to 7 ± 0.1 ± 0. 0 to 00 to 7 ± 0.80 ± 1. W 0 to 00 to 17 00 to 100 7 to ± 0.0 ± 0.90 100 to 000 to 6 ± 0.60 ± 1.08 ASTM 000 to 00 6 to 17 ± 0.90 ± 1.6 E988 0 to 00 to 7 ± 0.70 ± 1.6 W 0 to 00 to 17 00 to 100 7 to ± 0.0 ± 0.90 100 to 000 to 6 ± 0.70 ± 1.6 000 to 00 6 to 17 ± 0.90 ± 1.6-00 to -0-8 to -8 ± 0.0 ± 0. L -00 to 900-8 to 16-0 to 900-8 to 16 ± 0.0 ± 0.6 DIN710-00 to -0-8 to -8 ± 0.0 ± 0.90 U -00 to 600-8 to 111-0 to 600-8 to 111 ± 0. ± 0. Pt100-00 to 80-8 to 16-00 to 80-8 to 16 ± 0.1 ± 0. Pt00 IEC71-00 to 80-8 to 16-00 to 80-8 to 16 ± 0.0 ± 0. RTD Pt00-00 to 80-8 to 16 10 C -00 to 80-8 to 16 ± 0.0 ± 0.6 JPt100 JIS C160-00 to 00-8 to 9 (18 F) -00 to 00-8 to 9 ± 0.16 ± 0.9 Cu SAMA -70 to -0-9 to -0 ± 1. ±. -70 to 10-9 to 0 RC1- -0 to 10-0 to 0 ± 1.0 ± 1.8 Ni10-70 to 0-9 to 608-70 to 0-9 to 608 ± 0.11 ± 0.19 mv -10 to 100 [mv] [mv] ± 1 [µ V] ohm 0 to 000 [Ω] 0 [Ω] ± 0. [Ω] Total Accuracy = (A/D Accuracy / Span + D/A Accuracy) or (± 0.1% of calibrated span), whichever is greater. For T/C input, add Cold Junction Compensation Accuracy (± 0. C) to the total accuracy. Example; when selecting Pt100 with measurement range of 0 to 00 C. 0.1 C 100% of span +0.0% of span = 0.09% of span 00 C Since the value is smaller than ± 0.1% of span, the total accuracy is ± 0.1%. ± 0.0% of span T01E.EPS GS 01C0B01-00E Aug. 11, 006-00

Table. Temperature Coefficient Sensor Type Thermocouples E,J,K,N,T,L,U Thermocouples R,S,W,W 100 C Reading < 00 C T/C B 00 C Reading RTD mv ohm Temperature Coefficient 0.08 C + 0.0% of abs.reading 0. C + 0.0% of abs.reading 1 C + 0.0% of abs.reading 0. C + 0.0% of abs.reading 0.08 C + 0.0% of abs.reading 0.00 mv + 0.0% of abs.reading 0.1 Ω + 0.0% of abs.reading T0E.EPS Note1: Ambient Temperature Effect per 10 C change is 0.1% or (temperature coefficient/span), whichever is greater. Note: The abs.reading on Table means the absolute value of the reading in C. Example of abs reading; When the temperature value is 0 Kelvin, abs reading is.1, absolute (0 7.1). Example of Ambient Temperature Effect; Conditions; 1) Input Sensor: Pt100 ) Calibration Range: 100 to 100 C ) Reading value: 0 C Ambient Temperature Effect per 10 C; Temperature Coefficient/Span=(0.08 C 0.0/100 0 C )/{100 C ( 100 C)}= 0.000 0.0% Therefore, Ambient Temperature Effect is 0.1%/10 C R( ) 600 External load resistance 0 R= E-10. 0.06 Digital Communication range BRAIN and HART F0E.EPS Figure. Integral Indicator Display Example. 10. 16..7 Power supply voltage E (V DC) F01E.EPS Figure 1. Relationship Between Power Supply Voltage and External Load Resistance. GS 01C0B01-00E Apr. 0, 007-00

MODEL AND SUFFIX CODES Model Suffix Codes Descriptions YTA110 Temperature Transmitter Output Signal -D to 0mA DC with digital commnuication (BRAIN protocol) -E to 0mA DC with digital communication (HART protocol, refer to GS 01C0T01-00E) A Always A Electrical Connection 0 G1/ female 1/ NPT female Pg 1. female M0 female Integral Indicator D with digital indicator N None Mounting Bracket B D SUS0 Stainless steel -inch horizontal pipe mounting * 1 SUS0 Stainless steel -inch vertical pipe mounting * 1 N None Optional Codes / Optional Specifications *1: For flat-panel mounting, please prepare bolts and nuts. T0E.EPS OPTIONAL SPECIFICATIONS Item Descriptions Code Lightning protector Power supply voltage: 10. to V DC A Allowable current: Max. 6000A(1 0 s), repeating 1000A(1 0 s) 100 times Painting Coating change Epoxy resin coating X1 Color change Amplifier cover only Calibration Unit Degree F/Degree R unit D Output signal low-side in Transmitter failure Amplifier and terminal Covers Munsell code: N1. Black Munsell code: 7.BG/1., Jade green Metallic silver Munsell code: 7. R/1 Red Output signal low-side: -%,. ma DC or less. Sensor burnout is also set to 'LOW': -.%,.6 ma DC. P1 P P7 PR C1 NAMUR NE Compliant Output signal limits:.8 ma to 0. ma Failure alarm down-scale: output status at CPU failure and hardware error is -%,. ma or less. Sensor burnout is also set to LOW: -.%,.6 ma DC. Failure alarm up-scale: output status at CPU failure and hardware error is 110%, 1.6 ma or more. In this case Sensor burnout is High: 110%, 1.6 ma DC. C C Data Configuration Stainless steel housing * 1 Description into Descriptor parameter of HART protocol (max. 16 characters) Housing Material: SCS1A stainless steel (equivalent to SUS16 cast stainless steel and ASTM CF-8M) CA E1 *1: Not applicable for optional code JF, G11, G1, P1, P, P7, PR, and X1. T0E.EPS GS 01C0B01-00E Apr. 0, 007-00

6 OPTIONAL SPECIFICATIONS (For Explosion Protected Types) Item Descriptions Code CENELEC ATEX (KEMA) Canadian Standards Association (CSA) Factory Mutual (FM) CENELEC ATEX (KEMA) Intrinsically safe, Flameproof approval and Type n combination [Intrinsically safe approval] Applicable standard: EN 001, EN 000, EN 08 Certificate: KEMA 0ATEX106X II 1G EEx ia IIC T,T Ambient Temerature: -0 to 70 C for T, -0 to 0 C for T Supply/Output circuit: Ui=0V, Ii=16mA, Pi=900mW, Ci=0nF, Li=660 H Input circuit: Uo=8.6V, Io=0mA, Po=70mW, Co= F, Lo=0mH Electrical Connection: 1/ NPT female and M0 female* 1 [Flameproof and Dust Ignition Proof Approval] Applicable Standard: EN 60079-0, IEC 60079-1, EN 611-0, EN 611-1 Certificate: KEMA 07ATEX010 II G Ex d IIC T6/T, II D Ex td A1 IP67 T70 C, T90 C Ambient Temperature for Gas Atmospheres: -0 to 7 C for T6, -0 to 80 C for T Ambient Temperature for Dust Atmospheres: -0 to 6 C for T70 C, -0 to 80 C for T90 C Enclosure: IP67 Electrical Connection: 1/ NPT female and M0 female* 1 [Type n approval] Applicable standard: EN60079-1 Referential standard: IEC60079-0, IEC60079-11 II G EEx nl llc T, T Ambient Temperature: -0 to 70 C for T, -0 to 0 C for T Supply/Output circuit: Ui=0V, Ci=0nF, Li=660 H Input circuit: Uo=8.6V, Io=0mA, Po=70mW, Co= F, Lo=0mH Electrical Connection: 1/ NPT female and M0 female* 1 CSA Intrinsically safe, non-incendive and Explosionproof approval combination [Intrinsically safe/non-incendive approval] Applicable standard: C. No0, C. No0., C. No, C. No9, C. No1, C. No17, C. No1 Certificate: 17608-0001087 Intrinsically safe for Class I, Division 1, Groups A, B, C and D; Class II, Division 1, Groups E, F and G; Class III, Division 1: Non-incendive for Class I, Division, Groups A, B, C and D; Class II, Division, Groups E, F and G; Class III, Division 1: Enclosure Type X Temperature Class: T, Ambient Temperature: -0 to 60 C, Supply: Vmax=0V, Imax=16mA, Pmax=0.9W, Ci=18nF, Li=70 H Sensor input: Voc=9V, Isc=0mA, Po=0.09W, Ca=1 F, La=10mH Electrical Connection: 1/ NPT female* 1 [Explosionproof approval] Applicable standard: C. No0, C. No0., C. No, C. No0, C. No9, C. No1, C. No17, C. No1, C. No1010.1 Certificate: 108976 Explosionproof Class I, Div.1, Groups B, C and D, Class II, Groups E, F and G, Class III. For Class I, Div. Locations FACTORY SEALED, CONDUIT SEAL NOT REQUIRED Enclosure Type X Temperature Class: T6 Ambient Temperature: -0 to 60 C Electrical Connection: 1/ NPT female* FM Intrinsically safe, non-incendive and Explosionproof approval combination [Intrinsically safe/non-incendive approval] Applicable standard: FM 600, FM 610, FM 611, FM 810 Intrinsically safe for Class I, II, III Division 1 Groups A, B, C, D, E, F and G. Non-incendive for Class I, II, Division Groups A, B, C, D, F and G Class III, Division 1. Enclosure Type: X Temperature Class: T Ambient Temperature: -0 to 60 C (-0 to 10 F) Supply: Vmax=0V, Imax=16mA, Pmax=0.9W, Ci=18nF, Li=70 H Sensor: Voc=9V, Isc=0mA, Po=90Mw, Ca=1 F, La=10mH [Explosionproof approval] Applicable standard: FM 600, FM 61, FM 810, NEMA0 Class I, Division 1, Groups A, B, C and D.; Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G. "FACTORY SEALD, CONDUIT SEAL NOT REQUIRED." Enclosure Ratings: NEMAX Temperature Class: T6 Ambient Temperature: -0 to 60 C (-0 to 10 F) Electrical Connection: 1/NPT female* *1 : Applicable for Electrical Connection Code and. * : Applicable for Electrical Connection Code. FM Explosionproof approval Applicable standard: FM 600, FM 61, FM 810, NEMA0 Explosionproof Class I, Division 1, Groups A, B, C and D; Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G. FACTORY SEALED, CONDUIT SEAL NOT REQUIRED. Enclosure Rating: NEMA X Temperature Class: T6 Ambient Temperature: -0 to 60 C (-0 to 10 F) Electrical Connection: 1/ NPT female* KU CU1 FU1 FF1 T0E-1.EPS GS 01C0B01-00E Feb. 01, 008-00

7 Standards Association of Australia (SAA) Item Descriptions Code Japanese Industrial Standards (TIIS) Attached flameproof packing adapter* IECEx Scheme* SAA Int rinsically safe, non-sparking and Flameproof approval combination [Intrinsically safe and non-sparking] Applicable standard: AS80.1, AS80.7, AS80.9 Certificate: AUS Ex 6X Ex ia IIC T (Tamb=70 C) IP66/67, Ex n IIC T (Tamb=70 C), IP66/67 Input parameters: Ui=0V, Ii=16mA, Pi=0.9W Output parameters: Uo=8.6V, Io=0mA, Po=6mW, Co=1 F [Flameproof approval] Applicable standard: AS80.1, AS80. Certificate: AUS Ex 60 Ex d IIC T6 (Tamb=7 C) IP66/67 Electrical connection: 1/ NPT female, Pg1. female and M0 female* TIIS Flameproof approval Ex ds IIC T6 X Electrical connection: G1/ female Applicable cable: O.D. 8. to 11 mm Amb. Temp.: -0 to 60 C IECEx Flameproof and Dust ignition proof Approval Applicable Standard: IEC 60079-0, IEC 60079-1, IEC 611-0, IEC 611-1 Certificate: IECEx KEM 07.00 Ex d IIC T6/T, Ex td A1 IP67 T70 C, T90 C Ambient Temperature for Gas Atmospheres: -0 to 7 C (-0 to 167 F) for T6, -0 to 80 C (-0 to 176 F) for T Ambient Temperature for Dust Atmospheres: -0 to 6 C (-0 to 19 F) for T70 C, -0 to 80 C (-0 to 176 F) for T90 C Enclosure: IP67 Electrical Connection: 1/ NPT female and M0 female T0E-.EPS * : If cable wiring is to be used to a TIIS flameproof type transmitter, do not fail to add the YOKOGAWA-assured flameproof packing adapter. * : Applicable for Electrical connection code, and. * : Applicable only for Australia, New Zealand area. 1 pc. pc. SU1 JF G11 G1 SF GS 01C0B01-00E Feb. 01, 008-00

8 DIMENSIONS -inch horizontal pipe mounting 6.(.7) Unit: mm (Approx. inch) Electrical Connection (Output signal) 111(.7) Electrical Connection (Input signal) With Indicator (Optional) 6(1.81) 6(.6) 18. (0.7) Terminal Cover 10 (.0) 16 (6.6) ø9 (.66) Shrouding Bolt (For Explosionproof type) 0 (1.7) (0.98) Ground Terminal Tag Plate Horizontal Pipe Mounting Bracket (Optional) 6(.1) -inch pipe, ø60.(ø.8) 70(.76) 90(.) -inch vertical pipe mounting 6.(.7) Electrical Connection (Output signal) 111(.7) Electrical Connection (Input signal) With Indicator (Optional) Shrouding Bolt (For Explosionproof type) 6(1.81) 6(.6) 18. (0.7) Terminal Cover ø9 (.66) 191. (7.) 09. (8.) Ground Terminal Tag Plate Vertical Pipe Mounting Bracket (Optional) 6(1.81) -inch pipe, ø60.(ø.8) 101(.98) 6(.) 98(.86) F0E.EPS GS 01C0B01-00E Feb. 01, 008-00

9 Terminals Terminal Configuration Power Supply and output terminal Communication Terminals (BT00 etc.) Connection hook External Indicator (ammeter) terminal * 1 Ground terminal CHECK METER Connection hook *1 M10 1. 1-deep female for mounting bracket *1: When using an external indicator or check meter, the internal resistance must be 10Ω or less. This hook is not available for Fieldbus communication type(output signal code F). F0.EPS Input Wiring Single input (YTA110) 1 (+) ( ) 1 (A) 1 (A) 1 (A) (A) T/C or DC milivolts two-wire RTD or ohm three-wire RTD or ohm four-wire RTD F0E.EPS < Ordering Information > Specify the following when ordering Model, suffix codes, and optional codes The instrument is shipped with the settings shown in Table A. Specify the following when necessary. 1. Sensor type. For RTD and resistance input, specify the number of wire as well. (Example; Pt00 -wire system). Calibration range and unit 1) Calibration range can be specified within the measurement range shown in Table 1. on page. ) Specify one range from C, K, F or R for temperature input. F and R are available when Optional code D is specified. It is not necessary to specify the unit of mv and ohm inputs, for these units automatically will be mv or Ω.. Tag Number. Other Items related with options /CA option allows specifying the setting Descriptor for HART protocol type at factory. Specify upto 16 characters to be entered in the Descriptor parameter. Table A. Settings upon shipment. Input sensor type Calibration range lower limit Calibration range upper limit Calibration unit Damping time constant Sensor burnout * 1 Output in Transmitter failure * 1 Pt100 three-wire system, or as specified "0" or as specified "100" or as specified " C" or as specified seconds High (110%, 1.6 ma DC) High (110%, 1.6 ma DC or more) Integral Indicator * PV Output type Sensor 1 Tag number As specified in order *1: Except when Optional code C1 or C is specified. *: When Integral indicator is specified. < Related Instruments > Power Distributor: Refer to GS 01B0T01-0E or GS 01B0T0-00E BRAIN TERMINAL: Refer to GS 01C00A11-00E < Reference > HART; Trademark of The HART Communiation Foundation. (USA) Material Cross Reference Table SUS0 AISI 0 T08E.EPS T07E.EPS Subject to change without notice. GS 01C0B01-00E Feb. 01, 008-00