ELECTRONICS TESTING CENTER(ETC), TAIWAN

Similar documents
CONFORMANCE TEST REPORT FOR EN /-6

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

ELECTRONICS TESTING CENTER, TAIWAN

ELECTRONICS TESTING CENTER, TAIWAN Report No.:13-12-RBO-024 EMC TESTING DEPARTMENT Page: 1/24

CE EMC Test Certification

CE TEST CERTIFICATION

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

ELECTRONICS TESTING CENTER, TAIWAN Report No.:14-04-RBO EMC TESTING DEPARTMENT Page: 1/25

CE TEST CERTIFICATION

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

CE EMC CERTIFICATION

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

CE EMC Test Certification

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC Test Report. Report Number: M030826

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

9. Electrostatic Discharge Immunity Test (ESD)

APPENDIX A. GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

TEST REPORT. Table of Contents

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC TEST REPORT. Report No.: CE10-LIE040101E

ELECTRONICS TESTING CENTER, TAIWAN

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

C E R T I F I C A T I O N

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

CE EMC TEST REPORT. According to

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT For Prokits Industries Co., Ltd.

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

EMC test report AU01+E04

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

Report No.: 9A042401C1 Page 1 of 51. Test Report. EN 50155: 2007 (EMC, Characteristic, Environmental Test) Prepared for

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC Test report for LED Panel Light Models , , , , ,

EMC TEST REPORT. According to

EMC TEST REPORT. according to

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

C E R T I F I C A T I O N

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

1 SUMMARY OF STANDARDS AND RESULTS

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

TEST REPORT... 1 CONTENT...

TEST REPORT FROM RFI GLOBAL SERVICES LTD

DIRECTORY - EMISSIONS

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

Declaration of Conformity.

Test Report GUANGDONG EAST POWER CO., LTD

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

TEST REPORT. Power Spout PLT V. tested to the specification

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

Declaration of Conformity

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

EMC Test report for Plug-in adaptor Models PM1Wab-ccc

EMC TEST REPORT For CE

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

2620 Modular Measurement and Control System

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Transcription:

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co., Ltd. : Auto-Drain Device : Blessing Model No. : H-07 Test Report File No. : 06-03-RBF-111-01 Date Test Item Received : Mar. 24, 2006 Date Test Campaign : Apr. 20, 2006 Completed Date of Issue : Apr. 20, 2006 Test Performed by ELECTRONICS TESTING CENTER (ETC), TAIWAN NO. 34, LIN 5, DING FU TSUN, LINKOU HSIANG, TAIPEI HSIEN, TAIWAN, R.O.C. http:// www.etc.org.tw; e-mail:r00@etc.org.tw TEL : (02)26023052 FAX : (02)26010910 This test report consists of 35 Pages. This test report is the property of ETC, and shall not be reproduced except in full, without the written consent of ETC. ETC hereby returns all rights-in-data to [Huan Vu Enterprise Co., Ltd.] for their exclusive legal use. Note : 1. The results of the Test Report relate only to the items tested. 2. The Test Report shall not be reproduced except in full, without the written approval of ETC.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 2 / 35 CONTENTS EMC TEST REPORT.....1 CONTENTS......2 1. TEST REPORT CERTIFICATION...4 2. GENERAL INFORMATIONS...6 2.1 Description of EUT:...6 2.2 Related Information of EUT:...6 2.3 Tested Configuration:...6 2.4 Deviation Record:...7 2.5 Modification Record:...7 3. SUMMARY OF TEST RESULTS...8 3.1 Emissions:...8 3.1.1 Conducted Emissions...8 3.1.2 Radiated (Absorbing Clamp) Emissions...8 3.1.3 Harmonics Current Emissions...8 3.1.4 Voltage Fluctuations and Flicker...8 3.2 Immunity...9 3.2.1 Immunity Criteria...9 3.2.2 Electrostatic Discharge Immunity...9 3.2.3 RF Radiated Fields Immunity...9 3.2.4 EFT/Burst Immunity...9 3.2.5 Surge Immunity...10 3.2.6 RF Common Mode Immunity...10 3.2.7 Voltage Interruptions and Voltage Dips Immunity...10 4. TEST DATA & RELATED INFORMATIONS...11 4.1 Emissions:...11 4.1.1 Conducted Emissions Test :...11 4.1.1.1 Conducted Emissions Test Data:...11 4.1.1.2 Conducted Emissions Test Setup Photos :...15 4.1.2 Radiated (Absorbing Clamp) Emissions:...16 4.1.2.1 Radiated (Absorbing Clamp) Test Data:...16 4.1.2.2 Radiated (Absorbing Clamp) Emissions:...17 4.1.3 Harmonics Current Emissions Test :...18 4.1.3.1 Harmonics Current Emissions Test Data:...18 4.1.3.2 Harmonics Current Emissions Test Setup Photos :...20 4.1.4 Voltage Fluctuations and Flicker Test :...21

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 3 / 35 4.1.4.1 Voltage Fluctuations and Flicker Test Data:...21 4.1.4.2 Voltage Fluctuations and Flicker Test Setup Photos:...22 4.2 Immunity...23 4.2.1 Electrostatic Discharge Immunity Test...23 4.2.1.1 Electrostatic Discharge Immunity Test Data...23 4.2.1.2 Electrostatic Discharge Immunity Test Setup Photos...25 4.2.2 Radio frequency electromagnetic field :...26 4.2.2.1 Radio frequency electromagnetic field test data:...26 4.2.2.2 Radio frequency electromagnetic field test setup photos :...27 4.2.3 EFT/Burst Immunity Test...28 4.2.3.1 EFT/Burst Immunity Test Data...28 4.2.3.2 EFT/Burst Immunity Test Setup Photos...29 4.2.4 Surge Immunity Test...30 4.2.4.1 Surge Immunity Test Data...30 4.2.4.2 Surge Immunity Test Setup Photos...31 4.2.5 RF Common Mode Immunity Test...32 4.2.5.1 RF Common Mode Immunity Test Data...32 4.2.5.2 RF Common Mode Immunity Test Setup Photos...33 4.2.6 Voltage Interruptions and Voltage Dips Immunity Test...34 4.2.6.1 Voltage Interruptions and Voltage Dips Immunity Test Data...34 4.2.6.2 Voltage Interruptions and Voltage Dips Immunity Test Setup Photos...35

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 4 / 35 1. TEST REPORT CERTIFICATION Client : Huan Vu Enterprise Co., Ltd. Address : 3F N0. 10, Chung-Hsing Rd., Sec. 1, Wu-Ku, Taipei Hsien, Taiwan Manufacturer : Huan Vu Enterprise Co., Ltd. Address : 3F N0. 10, Chung-Hsing Rd., Sec. 1, Wu-Ku, Taipei Hsien, Taiwan EUT : Auto-Drain Device Trade name : Blessing Model No. : H-07 Test specifications : Emissions : EN 55014-1:2000/A1:2001/A2:2002 EN 61000-3-2: 2000 EN 61000-3-3:1995/A1:2001 Immunity : IEC61000-4-2:1995:A1:1998/A2:2000 IEC61000-4-3: 2002 IEC61000-4-4:1995/A1:2000/A2:2001 IEC61000-4-5:1995/A1:2000 IEC61000-4-6:1996/A1:2000 IEC61000-4-11:1994/A1:2000 Regulations applied : Emissions Immunity : EN 55014-1:2000/A1:2001/A2:2002 EN 61000-3-2: 2000 EN 61000-3-3:1995/A1:2001 : EN 55014-2:1997/A1:2001 The testing described in this report has been carried out to the best of our knowledge and ability, and our responsibility is limited to the exercise of reasonable care. This certification is not intended to believe the sellers from their legal and/or contractual obligations.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 6 / 35 2.1 Description of EUT: 2. GENERAL INFORMATIONS Max. Water Head: 4.2M Max. Drainage: 5.6Liters/Min. Standard Drainage Pipe: Inner Diameter 8mm Motor: Type Shaded-pole Motor Outer Diameter 11mm Protector High temperature protection fuse(105 C) 2.2 Related Information of EUT: Power Size of EUT : 220Vac, 50/60Hz : 214mm(H)x 132mm(W)x 153mm(D) Cables dedicated for EUT: Power Cord : [X] Nonshielded [ ] Shielded [ ] None, Length: 1.0 m AV Cable : [ ] Nonshielded [ ] Shielded [ ] None, Length: m Coaxial Cable : [ ] Nonshielded [ ] Shielded [ ] None, Length: m S-Video Cable : [ ] Nonshielded [ ] Shielded [ ] None, Length: m Audio Cable : [ ] Nonshielded [ ] Shielded [ ] None, Length: m * For more detailed features, please refer to User s Manual. 2.3 Tested Configuration: The EUT connected with other devices. Following peripheral devices and interface cables were connected during the measurement: For Conducted Emission Test and Radiated Emission Test Product Manufacturer Model No. I/O Cable Auto-Drain Device* Huan Vu Enterprise Co., Ltd. 1.0 Unshielded AC Power Line Remark * means equipment under test.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 7 / 35 2.4 Deviation Record: No deviations were required. 2.5 Modification Record: No modifications were required. (That is the EUT complied with the requirement as tested.)

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 8 / 35 3.1 Emissions: 3. SUMMARY OF TEST RESULTS 3.1.1 Conducted Emissions [X] PASS (Mode: Operation Mode (Neutral) Minimum EMI Margin to the limit: -22.4 db at 1.035 MHz [X] PASS (Mode: Operation Mode(Line) Minimum EMI Margin to the limit: -21.4 db at 1.492 MHz 3.1.2 Radiated (Absorbing Clamp) Emissions [X] PASS Minimum EMI Margin(QP) to the limit: -15.8 db at 30.200 MHz 3.1.3 Harmonics Current Emissions [X] PASS The harmonics current values were under the limits of the class A equipment of the EN 61000-3-2. 3.1.4 Voltage Fluctuations and Flicker [X] PASS The voltage fluctuations and flicker values were under the limits of the EN 61000-3-3 requirements.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 9 / 35 3.2 Immunity 3.2.1 Immunity Criteria The results of all of the immunity tests performed on the EUT were evaluated according to the following criteria, and according to the manufacturer s specifications for the EUT: Performance criterion A : Performance criterion B : Performance criterion C: The EUT continued to operate as intended. No degradation of performance or loss of function was allowed below a performance level specified by the manufacturer, when the EUT was used as intended. The EUT continued to operate as intended after the test. No degradation of performance or loss of function was allowed below a performance level specified by the manufacturer, when the EUT was used as intended. During the test, degradation of performance was however allowed. No change of actual operating state or stored data was allowed. Temporary loss of function was allowed, provided the function was self recoverable or could be restored by the operation of the controls. 3.2.2 Electrostatic Discharge Immunity [X] - No Degradation of Function Requirement :Criterion B (or better) - Satisfies Criterion A [ ] - Distortion of Function - Satisfies Criterion B [ ] - Error of Function - Satisfies Criterion C 3.2.3 RF Radiated Fields Immunity [X] - No Degradation of Function Requirement :Criterion B (or better) - Satisfies Criterion A [ ] - Distortion of Function - Satisfies Criterion B [ ] - Error of Function - Satisfies Criterion C 3.2.4 EFT/Burst Immunity [X] - No Degradation of Function Requirement :Criterion B(or better) - Satisfies Criterion A [ ] - Distortion of Function - Satisfies Criterion B [ ] - Error of Function - Satisfies Criterion C

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 10 / 35 3.2.5 Surge Immunity [X] - No Degradation of Function Requirement :Criterion B (or better) - Satisfies Criterion A [ ] - Distortion of Function - Satisfies Criterion B [ ] - Error of Function - Satisfies Criterion C 3.2.6 RF Common Mode Immunity [X] - No Degradation of Function Requirement :Criterion A - Satisfies Criterion A [ ] - Distortion of Function - Satisfies Criterion B [ ] - Error of Function - Satisfies Criterion C 3.2.7 Voltage Interruptions and Voltage Dips Immunity Requirement :Criterion C (or better) [X] - No Degradation of Function - Satisfies Criterion A [ ] - Distortion of Function - Satisfies Criterion B [ ] - Error of Function - Satisfies Criterion C

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 11 / 35 4. TEST DATA & RELATED INFORMATIONS 4.1 Emissions: 4.1.1 Conducted Emissions Test : 4.1.1.1 Conducted Emissions Test Data: Operating Conditions of The EUT : Operating (Conduction 1) Test Date : Apr. 03, 2006 Test Specification EN 55014-1:2000/A1:2001/A2:2002 Equipment Manufacturer Model No. Calibration Date Next Cal. Date EMI Test Receiver Rohde & Schwarz ESCI 2005/11/29 2006/11/28 LISN EMCO 3825/2 2005/07/04 2006/07/03 LISN Rohde & Schwarz ESH2-Z5 2005/09/12 2006/09/11 Climatic Condition Ambient Temperature : 25 C Relative Humidity: 60 %RH Power Supply System Test Set-up AC Power : 230 Vac 50 Hz Table-top Equipment Test data see the next pages.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 12 / 35 Neutral Frequency Meter Reading Result Limit Margin Factor (dbµv) (dbµv) (dbµv) (dbµv) (MHz) Q.P AVG (db) Q.P AVG Q.P AVG Q.P AVG 0.177 27.2 ---- 0.2 27.4 ---- 64.6 54.6-37.2 ---- 0.267 26.3 ---- 0.2 26.5 ---- 61.2 51.2-34.7 ---- 0.531 33.1 ---- 0.3 33.4 ---- 56.0 46.0-22.6 ---- 1.035 33.3 ---- 0.3 33.6 ---- 56.0 46.0-22.4 ---- 1.492 29.9 ---- 0.4 30.3 ---- 56.0 46.0-25.7 ---- 1.984 24.2 ---- 0.5 24.7 ---- 56.0 46.0-31.3 ---- 3.605 25.1 ---- 0.6 25.7 ---- 56.0 46.0-30.3 ---- 5.980 23.2 ---- 0.7 23.9 ---- 60.0 50.0-36.1 ---- 9.930 24.7 ---- 0.8 25.5 ---- 60.0 50.0-34.5 ---- 22.821 31.9 ---- 1.5 33.4 ---- 60.0 50.0-26.6 ---- 29.101 24.3 ---- 2.1 26.4 ---- 60.0 50.0-33.6 ---- Notes: 1) Place of measurement: EMC LAB. of the ETC 2) The EUT was placed 0.8m above reference ground plane. 3) The symbol of "----" means the Q.P. value is under the limit for AVG. so, the AVG. value doesn't need to be measured. 4) The expanded uncertainty of the conducted emission tests is 2.45 db.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 13 / 35 Line Frequency Meter Reading Result Limit Margin Factor (dbµv) (dbµv) (dbµv) (dbµv) (MHz) Q.P AVG (db) Q.P AVG Q.P AVG Q.P AVG 0.177 40.2 ---- 0.2 40.4 ---- 64.6 54.6-24.2 ---- 0.267 31.1 ---- 0.2 31.3 ---- 61.2 51.2-29.9 ---- 0.531 27.3 ---- 0.3 27.6 ---- 56.0 46.0-28.4 ---- 1.035 25.4 ---- 0.3 25.7 ---- 56.0 46.0-30.3 ---- 1.492 34.2 ---- 0.4 34.6 ---- 56.0 46.0-21.4 ---- 1.984 31.9 ---- 0.5 32.4 ---- 56.0 46.0-23.6 ---- 3.605 22.6 ---- 0.6 23.2 ---- 56.0 46.0-32.8 ---- 5.980 23.4 ---- 0.7 24.1 ---- 60.0 50.0-35.9 ---- 9.930 25.1 ---- 0.8 25.9 ---- 60.0 50.0-34.1 ---- 22.828 28.9 ---- 1.5 30.4 ---- 60.0 50.0-29.6 ---- 29.101 23.2 ---- 2.1 25.3 ---- 60.0 50.0-34.7 ---- Notes: 1) Place of measurement: EMC LAB. of the ETC 2) The EUT was placed 0.8m above reference ground plane. 3) The symbol of "----" means the Q.P. value is under the limit for AVG. so, the AVG. value doesn't need to be measured. 4) The expanded uncertainty of the conducted emission tests is 2.45 db.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 14 / 35 Neutral Line

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 15 / 35 4.1.1.2 Conducted Emissions Test Setup Photos :

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 16 / 35 4.1.2 Radiated (Absorbing Clamp) Emissions: 4.1.2.1 Radiated (Absorbing Clamp) Test Data: Operating Conditions of The EUT : Operating Test Date : Apr. 03, 2006 Test Specification EN 55014-1:2000/A1:2001/A2:2002 Equipment Manufacturer Model No. Calibration Date Next Cal. Date Absorbing Clamp Rohde & Schwarz MDS-21 2005/04/29 2006/04/28 Spectrum Rohde & Schwarz FSP40 2005/07/06 2006/07/05 Climatic Condition Ambient Temperature : 25 C Relative Humidity: 60 %RH Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Meter Reading Result Limit Margins Freq. (db V) Factor (dbpw) (dbpw) (db) (MHz) Q.P. Value AVG. Value (db) Q.P. Value AVG. Value Q.P. Value AVG. Value Q.P. Value AVG. Value 30.200 25.3 ---- 3.9 29.2 ---- 45.0 35.0-15.8 ---- 45.100 24.9 ---- 0.0 24.9 ---- 45.6 35.6-20.7 ---- 66.300 25.1 ---- -0.1 25.0 ---- 46.3 36.3-21.3 ---- 91.200 26.4 ---- -0.3 26.1 ---- 47.3 37.3-21.2 ---- 152.700 34.1 ---- -1.4 32.7 ---- 49.5 39.5-16.8 ---- 183.100 26.1 ---- -2.1 24.0 ---- 50.7 40.7-26.7 ---- 221.400 27.4 ---- -2.4 25.0 ---- 52.1 42.1-27.1 ---- 299.600 28.2 ---- -2.1 26.1 ---- 55.0 45.0-28.9 ---- Notes: 1) Place of Measurement: Measuring site of the ETC 2) Measurement Distance: 10 m 3) Height of table on which the EUT was placed: 0.8 m 4) Height of Receiving Antenna: 1-4 m 5) Remark ---- means that the emissions level is too low to be measured. 6) The expanded uncertainty of the radiated emission tests is 3.53 db.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 17 / 35 4.1.2.2 Radiated (Absorbing Clamp) Emissions:

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 18 / 35 4.1.3 Harmonics Current Emissions Test : 4.1.3.1 Harmonics Current Emissions Test Data: Operating Conditions of The EUT : Operating Test Date : Apr. 10, 2006 Test Specification EN 61000-3-2:2002 Equipment Manufacturer Model No. Calibration Date Next Cal. Date Hormonics-1000 EMC-Partner Hormonics-1000 2005/09/22 2006/09/21 Climatic Condition Ambient Temperature : 18 C Relative Humidity: 65 %RH Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Test data see the next pages.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 19 / 35 ETC Operator : Unit : Serialnumber : Remarks : Urms = 230.1V Freq = 50 Range: 5A Irms = 0.034A Ipk = 0.044A cf = 1.286 P = 0.859W S = 7.865VA pf = 0.109 THDi = 18.60% THDu = 0.10% Class A Test - Time : 3min -100% Test completed, Result: PASSED Order Freq. Iavg Imax Limit Order Freq. Iavg Imax Limit [Hz] [A] [A] [A] [Hz] [A] [A] [A] 1 50 0.7175 2.1857 21 1050 0 0.0034 0.1071 2 100 0.0073 0.0418 1.08 22 1100 0 0.0024 0.0836 3 150 0.2362 0.712 2.3 23 1150 0 0.0027 0.0978 4 200 0.0009 0.0198 0.43 24 1200 0 0.0024 0.0767 5 250 0.0626 0.1971 1.14 25 1250 0 0.0024 0.09 6 300 0 0.0116 0.3 26 1300 0 0.0021 0.0708 7 350 0.0204 0.0568 0.77 27 1350 0 0.0024 0.0833 8 400 0 0.0061 0.23 28 1400 0 0.0021 0.0657 9 450 0 0.0137 0.4 29 1450 0 0.0024 0.0776 10 500 0 0.0052 0.184 30 1500 0 0.0021 0.0613 11 550 0 0.0055 0.33 31 1550 0 0.0021 0.0726 12 600 0 0.004 0.1533 32 1600 0 0.0021 0.0575 13 650 0 0.0043 0.21 33 1650 0 0.0021 0.0682 14 700 0 0.0037 0.1314 34 1700 0 0.0021 0.0541 15 750 0 0.0052 0.15 35 1750 0 0.0021 0.0643 16 800 0 0.0031 0.115 36 1800 0 0.0021 0.0511 17 850 0 0.004 0.1324 37 1850 0 0.0021 0.0608 18 900 0 0.0027 0.1022 38 1900 0 0.0021 0.0484 19 950 0 0.0034 0.1184 39 1950 0 0.0021 0.0577 20 1000 0 0.0027 0.092 40 2000 0 0.0021 0.046

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 20 / 35 4.1.3.2 Harmonics Current Emissions Test Setup Photos :

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 21 / 35 4.1.4 Voltage Fluctuations and Flicker Test : 4.1.4.1 Voltage Fluctuations and Flicker Test Data: Test Date : Apr. 10, 2006 Test Specification EN 61000-3-3:1995/A1:2001 Equipment Manufacturer Model No. Calibration Date Next Cal. Date Hormonics-1000 EMC-Partner Hormonics-1000 2005/09/22 2006/09/21 Climatic Condition Ambient Temperature : 21 C Relative Humidity: 49 %RH Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 22 / 35 4.1.4.2 Voltage Fluctuations and Flicker Test Setup Photos:

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 23 / 35 4.2 Immunity 4.2.1 Electrostatic Discharge Immunity Test 4.2.1.1 Electrostatic Discharge Immunity Test Data Operating Conditions of The EUT : Operation mode Test Date : Apr. 10, 2006 Test Specification IEC 61000-4-2:1995/A1:1998/A2:2000 Equipment Manufacturer Model No. Calibration Date Next Cal. Date EMC Immunity tester EMC-PARTNER TRANSIENT-1000 2005/11/22 2006/11/21 Climatic Condition Ambient Temperature : 21 C Relative Humidity: 49 %RH Atmospheric Pressure : 990 mbar Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Energy-Storage Capacitor 150 pf Contact Discharge Times 10 times/each condition Discharge Resistor 330 Ω Air Discharge Times 10 times/each condition \ Discharge Mode Contact Discharge Air Discharge \ESD Voltage 2 kv 4 kv kv kv 2 kv 4 kv 8 kv kv \Points\Result\Polarity + - + - + - + - + - + - + - + - VCP N N N N --- --- --- --- --- --- --- --- --- --- --- --- HCP N N N N --- --- --- --- --- --- --- --- --- --- --- --- P 1 ~ P 11 --- --- --- --- --- --- --- --- N N N N N N --- --- Note : --- means the test could not be carrier out. N means the EUT function was correct during the test

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 24 / 35 TEST POINTS

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 25 / 35 4.2.1.2 Electrostatic Discharge Immunity Test Setup Photos

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 26 / 35 4.2.2 Radio frequency electromagnetic field : 4.2.2.1 Radio frequency electromagnetic field test data: Operating Conditions of The EUT : Operation Mode Test Date : Apr. 10, 2006 Test Specification IEC 61000-4-3:2002 Equipment Manufacturer Model No. Calibration Date Next Cal. Date Antenna AR AT5080 2005/05/30 2006/05/29 signal Generator Aglient E4421B 2005/05/30 2006/05/29 Amplifier Ophir 5172 2005/05/30 2006/05/29 Amplifier Ophir 5127 2005/05/30 2006/05/29 POWER METER Booton 4232A 2005/05/30 2006/05/29 Climatic Condition Ambient Temperature : 21 C Relative Humidity: 51 %RH Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Frequency Range 80 MHz ~ 1000 MHz Field Strength 3 V/m Modulation(AM 1kHz 80%) Sweep Rate 1.5 10-3 decades/s Step Size 1 % of preceding frequency value Dwell Time 2.9 s Frequency Range (MHz) Test Axis Polarization of Device Test Result 80~1000 x-axis Vertical N 80~1000 y-axis Vertical N 80~1000 z-axis Vertical N Note : N means the EUT function was correct during the test.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 27 / 35 4.2.2.2 Radio frequency electromagnetic field test setup photos :

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 28 / 35 4.2.3 EFT/Burst Immunity Test 4.2.3.1 EFT/Burst Immunity Test Data Operating Conditions of The EUT : Operation mode Test Date : Apr. 10, 2006 Test Specification IEC 61000-4-4:1995/A1:2000/A2:2001 Equipment Manufacturer Model No. Calibration Date Next Cal. Date EMC Immunity tester EMC-PARTNER TRANSIENT-1000 2005/11/22 2006/11/21 Climatic Condition Ambient Temperature : 21 C Relative Humidity: 49 %RH Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Pulse :5/50ns Burst :15m/300ms \Voltage\Polarity\ Repetition Rate: 2.5kHz above 2.0kV 5kHz below and equal 2.0kV 1.0 kv Test time: 2 min/each condition \Test Point\Mode\Result\ + - L N N Power Line N N N L-N N N PE N N L-PE N N N-PE N N L-N-PE N N Note : N means the EUT function was correct during the test

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 29 / 35 4.2.3.2 EFT/Burst Immunity Test Setup Photos

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 30 / 35 4.2.4 Surge Immunity Test 4.2.4.1 Surge Immunity Test Data Operating Conditions of The EUT : Operation mode Test Date : Apr. 10, 2006 Test Specification IEC 61000-4-5:1995/A1:2000 Equipment Manufacturer Model No. Calibration Date Next Cal. Date EMC Immunity tester EMC-PARTNER TRANSIENT-1000 2005/11/22 2006/11/21 Climatic Condition Ambient Temperature : 21 C Relative Humidity: 49 %RH Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Waveform : 1.2/50µs(8/20µs) Repetition rate : 60 sec Times : 1 time/each condition \Phase \Voltage \Mode \Polarity \Result 0 o 90 o 180 o 270 o 360 o 0.5kV/ 1.0kV 0.5kV/ 1.0kV/ 2.0kV L N L-PE N-PE + N N N N N N N N N N + N N N N N N N N N N + N N N N N N N N N N Note : N means the EUT function was correct during the test.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 31 / 35 4.2.4.2 Surge Immunity Test Setup Photos

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 32 / 35 4.2.5 RF Common Mode Immunity Test 4.2.5.1 RF Common Mode Immunity Test Data Operating Conditions of The EUT : Operation mode Test Date : Apr. 10, 2006 Test Specification IEC 61000-4-6:1996/A1:2000 Equipment Manufacturer Model No. Calibration Date Next Cal. Date CS TESTER FRANKONIA CIT-10 2005/08/10 2006/08/09 M2+3 CDN-KIT FRANKONIA M2+3 2005/07/22 2006/07/21 Climatic Condition Ambient Temperature : 23 C Relative Humidity: 51 %RH Atmospheric Pressure : 990 mbar Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Frequency Range 0.15 MHz ~ 80 MHz Field Strength 3 Vrms Modulation (AM 1kHz 80%) Sweep Rate 1.5 10-3 decades/s Step Size 1 % of preceding frequency value Dwell Time 2.9 s Frequency Range (MHz) Tested Line Test Result 0.15~80 Power Line (M3) N Note : N means the EUT function was correct during the test.

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 33 / 35 4.2.5.2 RF Common Mode Immunity Test Setup Photos

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 34 / 35 4.2.6 Voltage Interruptions and Voltage Dips Immunity Test 4.2.6.1 Voltage Interruptions and Voltage Dips Immunity Test Data Operating Conditions of The EUT : Operation mode Test Date : Apr. 10, 2006 Test Specification IEC 61000-4-11:1994/A1:2000 Equipment Manufacturer Model No. Calibration Date Next Cal. Date EMC Immunity tester EMC-PARTNER TRANSIENT-1000 2005/11/22 2006/11/21 Climatic Condition Ambient Temperature : 21 C Relative Humidity: 49 %RH Atmospheric Pressure : 990 mbar Power Supply System AC Power : 230 Vac 50 Hz Test Set-up Table-top Equipment Test mode Voltage dips Durations (Period) Interval(s) Times Phase Result Voltage interruptions 100% 0.5 10 12 0 /180 N Voltage dips in %UT 60% 10 10 12 0 /180 N Voltage dips in %UT 30% 50 10 12 0 /180 N Note : N means the EUT function was correct during the test

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 35 / 35 4.2.6.2 Voltage Interruptions and Voltage Dips Immunity Test Setup Photos

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 5 CONSTRUCTED PHOTOS of EUT 1. Front View of EUT 2. Top View of EUT

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 2 / 5 CONSTRUCTED PHOTOS of EUT 3. Bottom View of EUT 4. Side View of EUT

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 3 / 5 CONSTRUCTED PHOTOS of EUT 5. Rear View of EUT 6. Side View of EUT

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 4 / 5 CONSTRUCTED PHOTOS of EUT 7. Internal View of EUT

File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 5 / 5 CONSTRUCTED PHOTOS of EUT 8. Component View of PCB 9. Solder View of PCB