Application Note. Airbag Noise Measurements

Similar documents
Measuring Recreational Firearm Noise

GRAS 40BD-FV 1/4" Prepolarized Pressure Microphone, Front Vented

G.R.A.S. Sound & Vibration

Proceedings of Meetings on Acoustics

THE USE OF VOLUME VELOCITY SOURCE IN TRANSFER MEASUREMENTS

High Resolution Ear Simulator

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type 4297

Audio Engineering Society. Conference Paper. Presented at the Conference on Audio Forensics 2017 June Arlington, VA, USA

430. The Research System for Vibration Analysis in Domestic Installation Pipes

Effect of coupling conditions on ultrasonic echo parameters

Development of a sonic boom measurement system at JAXA

Sound waves. septembre 2014 Audio signals and systems 1

Week 1. Signals & Systems for Speech & Hearing. Sound is a SIGNAL 3. You may find this course demanding! How to get through it:

Multi-field Microphone when the Sound Field is unknown

Data Communication. Chapter 3 Data Transmission

Microphones & Accessories

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Data and Computer Communications Chapter 3 Data Transmission

Terminology (1) Chapter 3. Terminology (3) Terminology (2) Transmitter Receiver Medium. Data Transmission. Simplex. Direct link.

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683

PRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

Phased Array Velocity Sensor Operational Advantages and Data Analysis

Week I AUDL Signals & Systems for Speech & Hearing. Sound is a SIGNAL. You may find this course demanding! How to get through it: What is sound?

CHAPTER ONE SOUND BASICS. Nitec in Digital Audio & Video Production Institute of Technical Education, College West

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

EC 554 Data Communications

Section 7 - Measurement of Transient Pressure Pulses

ni.com Sensor Measurement Fundamentals Series

5: SOUND WAVES IN TUBES AND RESONANCES INTRODUCTION

SHF Communication Technologies AG

Measuring Instrument Combinations

Sonic Distance Sensors

Organisation Internationale de Métrologie Légale

Resonance Tube Lab 9

Selection and Calibration of Acoustic Sensors

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

3D Distortion Measurement (DIS)

EQUIVALENT THROAT TECHNOLOGY

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

Product and Measurement Solutions for the Automotive Industry

Microphone calibration service for airborne ultrasound

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies

SECTION A Waves and Sound

3. Sound source location by difference of phase, on a hydrophone array with small dimensions. Abstract

Supplementary User Manual for BSWA Impedance Tube Measurement Systems

Chapter 3 Data Transmission COSC 3213 Summer 2003

PIV STUDY OF STANDING WAVES IN A RESONANT AIR COLUMN

A102 Signals and Systems for Hearing and Speech: Final exam answers

Development of Shock Acceleration Calibration Machine in NMIJ

Digital Signal Processing Audio Measurements Custom Designed Tools. Loudness measurement in sone (DIN ISO 532B)

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

EXPERIMENTAL INVESTIGATIONS OF DIFFERENT MICROPHONE INSTALLATIONS FOR ACTIVE NOISE CONTROL IN DUCTS

Terminology (1) Chapter 3. Terminology (3) Terminology (2) Transmitter Receiver Medium. Data Transmission. Direct link. Point-to-point.

In situ assessment of the normal incidence sound absorption coefficient of asphalt mixtures with a new impedance tube

Microphone Array Measurements for High-speed Train

SigCal32 User s Guide Version 3.0

SECTION A Waves and Sound

Microphone Cartridge Model: MP201

Pre Test 1. Name. a Hz b Hz c Hz d Hz e Hz. 1. d

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 4 th Edition / December 2008

Transfer Function (TRF)

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

ALTERNATING CURRENT (AC)

instructions for Models QC-10 and QC-20 Sound Calibrators MODELS QC-10/QC-20 SOUND CALIBRATORS GENERAL DESCRIPTION

Designing practical on-site. on-site calibration protocols for acoustic systems: key elements and pitfalls.

Method of Determining Effect of Heat on Mortar by Using Aerial Ultrasonic Waves with Finite Amplitude

Fig 1 Microphone transducer types

The Four Stages of Bearing Failures

Multi-spectral acoustical imaging

TIME FREQUENCY ANALYSIS OF TRANSIENT NVH PHENOMENA IN VEHICLES

Also, side banding at felt speed with high resolution data acquisition was verified.

Since the advent of the sine wave oscillator

BSWA Impedance Tube Solutions

Acoustics, signals & systems for audiology. Week 4. Signals through Systems

TBM - Tone Burst Measurement (CEA 2010)

Sensitivity of frequency response to type of tubing

Organisation Internationale de Métrologie Légale

Chapter 3. Data Transmission

Chapter 17 Waves in Two and Three Dimensions

SENSING OF METAL-TRANSFER MODE FOR PROCESS CONTROL OF GMAW

M.ENG PROJECT: TOADFISH BEHAVIORAL ROBOT FOR FISH AGGRESSION STUDY

Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2

Lecture Fundamentals of Data and signals

24-Bit, ks/s Dynamic Signal Acquisition and Generation

Measurement Techniques

PRODUCT DATA. Applications. Uses

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

Technical Documentation

A Tutorial on Acoustical Transducers: Microphones and Loudspeakers

Broad band air ultrasound reference sound source

Chapter 2. Meeting 2, Measures and Visualizations of Sounds and Signals

Momentum and Impulse. Objective. Theory. Investigate the relationship between impulse and momentum.

80 khz Cylindrical Ultrasound Transducer

Maximizing LPM Accuracy AN 25

Waves Q1. MockTime.com. (c) speed of propagation = 5 (d) period π/15 Ans: (c)

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

CCAUV/ CCAUV. Activities in KRISS. Wan-Cho Cho

Transcription:

Airbag Noise Measurements Headquarters Skovlytoften 33 2840 Holte Denmark Tel: +45 45 66 40 46 E-mail: gras@gras.dk Web: gras.dk

Airbag Noise Measurements* Per Rasmussen When an airbag inflates rapidly during a car accident, the driver is exposed to a large impulsive wave of sound pressure of short duration that could possibly damage human hearing. The time signals of these impulsive sound pressure waves were measured using transducers of various types and sizes in order to investigate the repeatability of the measured results both for each given transducer and between transducers. The aim was to find a suitable way for manufacturers to test airbags and to be able to make meaningful data comparisons. Introduction Impulsive pressure waves can be measured with various transducers, but which is the most realistic measurement? In this article I will try to answer this question by going into wave theory, clarifying the behavior of short impulsive waves from measurements with different transducer types on inflating airbags. Airbag Signal Characteristics The noise emitted during an airbag deployment is characterized by both an impulse with high frequency content and a pressure increase inside the vehicle compartment with low frequency content. While the determination of the lowfrequency pressure signal is easily done using a standard microphone with a suitable low cut-off frequency, the measurement of the high-frequency content needs careful selection of microphone, preamplifier and data acquisition system. The low-frequency content is caused by the expansion of the airbag inside the closed vehicle compartment and will be a function of the airbag size, the vehicle compartment internal volume and the venting-time constant of the vehicle compartment. The pressure increase will therefore be reduced if, for example, a window is opened or other leaks are introduced. The following measurements focus on the high-frequency impulse and the measurements have been performed in free air so that no low frequency-pressure increase is observed. The high-frequency impulse created by the inflation of the airbag is characterized by a very steep initial impulse which places great demands on the frequency response of the microphones and the signal handling capacity of the preamplifiers and data acquisition system. It is therefore necessary to consider factors such as diffraction around the microphone, frequency range, slew rate and sampling rates. LI0203 * This article has previously been published in Sound and Vibration, April 2007 2

Lowpass filtering Output impulse Input signal [db] Input impulse Time Filtered signal [db] Filtered signal [db] Filtered signal [db] Frequency [Hz] Frequency [Hz] Input signal [db] Input signal [db] Input signal [db] Time Time Frequency [Hz] Time Fig. 1. Low pass filtering of an impulse For an infinitely short pulse the resulting spectrum will be a broad band spectrum. If the pulse is transmitted through some linear system with band limitation, the spectrum will be changed and at the same time the pulse shape will be changed. Filtering the impulse through a bandlimiting filter such as a single-order lowpass Butterworth filter, the peak of the pulse will be reduced. Figure 1 shows the resulting waveform of an impulse filtered through filters with different cut-off frequencies. Similarly the introduction of high-pass filtering will change the shape of the pulse but not the peak of the pulse. Measuring a pulse with a measure ment microphone involves both high-pass and low-pass filtering. Due to the lower limiting frequency of the microphone itself and of the combination of microphone and preamplifier, the impulse will be high pass filtered with a cut-off frequency of around 1 to 5 Hz. This will, however, not change the peak value of the impulse, as mentioned above. Similarly, due to the limited upperfrequency range of the microphone and preamplifier, the input pulse will be lowpass filtered, thus reducing the pulse peak if the bandwidth of the pulse is larger than the bandwidth of the microphone. 3

Fig. 2. The three microphone sizes discussed in this paper Transducer Selection Choosing the right transducer for airbag noise measurements involves a number of compromises and considerations regarding dynamic range, frequency range, transducer size and type of response. Microphone dynamic range The airbag noise contains an impulse which requires a microphone with wide frequency range and the ability to handle high levels. The upper limit of the dynamic range of a measurement microphone is directly related to the sensitivity of the microphone. For a typical ½ measurement microphone with a sensitivity of 50mV/Pa, the upper range of the dynamic range is limited to around 146dB re 20μPa. For a typical airbag with a peak impulse of 4000 to 6000Pa, corresponding to 160 to 169dB re 20μPa, the microphone would be clearly overloaded as the expected output signal from the microphone should be around 200-300V. A typical ¼ microphone with a sensitivity of 4mV/Pa, would similarly give an output signal of around 16 to 24V. This can easily be handled by the microphone, but may cause problems with the associated preamplifier. Preamplifiers of the IEPE type are normally limited in their peak handling capacity to around 10 to 12V so in this case the preamplifier would be overloaded. The traditional (LEMO) types of microphone preamplifiers can normally be used with a supply voltage of ±60V, and will be able to handle peak input signals up to around ±56V. This will allow measurements of signals with peaks of up to around 14000Pa or 176dB re 20μPa. The sensitivity of the microphone can be reduced further by using a stiffer microphone diaphragm, but this will usually be accompanied by an increase in diaphragm mass and therefore a change in frequency response. The best result is obtained by decreasing the size of the microphone further, for example to ⅛. This 4

Fig. 3. Pressure increase in front of microphone due to diffraction Fig. 4. Diffraction for 1/2 and 1/4 microphones can be made with a sensitivity of around 0.8mV/Pa without sacrificing frequency range. With the sensitivity of 0.8mV/Pa and a preamplifier signal-handling capacity of up to around ±56V, the microphone can be used for signal peaks up to around 70000Pa or 190dB re 20μPa. Microphone frequency range The ability of microphones to handle sound impulses with very steep rise and fall times is directly related to the frequency range of the microphone. An ideal infinitely short pulse will theoretically have a frequency spectrum covering an infinite number of frequencies from low to high. If the frequency range of the pulse is limited, the shape of the pulse will be changed and the peak will be reduced. Another factor influencing the measurement results is the diffraction around the microphone. The diffraction is dependent on the size, shape and orientation of the microphone relative to the sound field. Normal measurement microphones are shaped as a cylinder with a flat end constituting the diaphragm. If the microphones are pointed towards the sound source, e.g. parallel to the propagation direction, the sound waves will be partially reflected by the presences of the microphone in the sound field. This will result in a pressure increase in front of the microphone, see Fig. 3, and this increase will be measured by the microphone. The amount of pressure increase, or diffraction, in front of the microphone will depend on the size (diameter) of the microphone relative to the wavelength of the sound. Since the wavelength depends on the frequency, the diffraction will be frequency dependent. This means that for a small microphone the diffraction will be smaller than for a large microphone and the diffraction will be more pronounced at higher frequencies as indicated in Fig. 4. 5

Wavefront propagation direction Wavefront propagation direction Wavefront propagation direction Time Fig. 5. Impulse travelling perpendicular to the diaphragm If the microphone is turned so that its diaphragm is parallel to the direction of propagation of the sound waves, no pressure increase in front of the diaphragm will occur. At higher frequencies, where the wavelength becomes small compared with the diameter of the microphone diaphragm, the microphone will underestimate the sound pressure. For example at 100 khz, the wavelength is 3.4 mm and the effective diaphragm diameter of a typical ¼ microphone is around 3.6 mm. This means that part of the diaphragm will be subjected to the under pressure of the sound wave and at the same time another part of the diaphragm will be subjected to over pressure, and the mean pressure over the full diaphragm will be close to zero, and the microphone output will underestimate the true sound pressure of the sound wave. For a short-duration pulse, its spatial length can be calculated from knowing the speed of sound. For example an impulse with duration of 0.005 ms will be 1.7 mm long, assuming a sound velocity of 340 m/s. Since this pulse is short compared with the effective diameter of the microphone s diaphragm, only part of the diaphragm will be excited by the impulse and as the nominal sensitivity of the microphone assumes an even excitation of the full diaphragm, the microphone will underestimate the impulse. So as the impulse travels across the diaphragm, see Fig. 5, different parts of the diaphragm will be excited. This also means that it is not the duration of the pulse itself which is measured, but the time it takes for the pulse to travel across the diaphragm. 6

Fig. 6. Microphone setup Fig. 7. Airbag mounted in front of the microphones Measurement Setup The airbag under test was securely mounted on the back of a trailer, Fig. 7, in a position 70 cm above ground and the microphone stand, Fig. 6, was placed in a horizontal line 80 cm from the centre of the airbag to avoid direct impact from the airbag itself. The data acquisition system and the controlling computer were placed inside a container about 10 m away. The airbag deployment and the start of the data acquisition was controlled by a common trigger signal generated by the computer An Olympus high speed video camera was place around 3 meters from the airbag to record the airbag inflation. Measurements were performed with four different microphones from G.R.A.S. Sound & Vibration: The microphones were placed in a line with 3 cm separation, on a common stand 70 cm above the ground, 80 cm away from the front of the airbag. The 40BP ¼ Pressure Microphone was placed with its diaphragm at 90 degree angle to the incidence wave front, so that no pressure increase in front of the diaphragm from diffraction occurs. The other microphones were mounted with their diaphragms pointing toward the airbag. This combination gave measurement data from the small 1/8 microphone to the standard size ½ microphone and makes it possible to analyze the effects of microphone size, frequency range and diffraction effects. 40DP ⅛ Pressure Microphone 40BF ¼ Free Field Microphone 40BP ¼ Pressure Microphone 40AF ½ Free Field Microphone 7

Ch0: 40AF + 26AC Ch1: 40BF + 26AL PXI-1042Q PXI-6120 Ch2: 40BP + 26AL Ch3: 40DP + RA0063 + 26AC Fig. 8. The measurement Chain The microphone capsules were powered by 12AA dual-channel power modules, and 26AC preamplifiers. Data acquisition hardware used for recording and storage of the four input signals was a National Instrument PXI chassis 1042Q with a PXI-6120 16 bit, 4 analogue input, simultaneous sampling data acquisition card. The data acquisition was controlled by a Labview program, using the 64 Ms onboard memory on the data acquisition card to measure the 4 channels simultaneously with a sampling frequency of 800000 samples per second per channel. Before each measurement, the microphones were calibrated by a 42AP precision pistonphone. This pistonphone delivers a 250Hz pure tone at 114dB. The sound pressure inside the coupler is automatically corrected for the ambient static barometric pressure. Correction values were implemented in the later analyses of the results. Each airbag set off was filmed by a high speed camera recording at 2000 pictures per second. 8

Fig. 9. Airbag deployment Measurement Results The deployment of a typical airbag is illustrated in Fig. 9. The recorded acoustical pressure signal was synchronized with recordings from a high speed video camera and analyzed with the National Instrument Diadem Clip software for synchronizing movie files with test data. Initially, the airbag is at rest until the deployment starts and the airbag outer case starts to deform. About 2 ms later, the audio signal shows a large high-frequency peak and the airbag starts to fill and move outwards away from the steering wheel. 8 ms later the airbag stops its outward movement, accompanied by a negative pressure pulse. The airbag then continues to fill up radially for the next 60 ms until it is completely filled and starts to deflate. The result shown above is for the 40DP ⅛ Pressure Microphone. 9

40DP 1/8 Pressure Microphone Pressure [Pa 1500 1000 40DP 1/8" Microphone 500 0-500 -1000-1500 0.1 0.125 0.15 0.175 0.2 Time [ms] 40BF 1/4 Free-field Microphone 1500 1000 40BF 1/4" Free field microphone 500 0-500 -1000-1500 0.1 0.125 0.15 0.175 0.2 Time [ms] 40BP 1/4 Pressure Microphone 1500 1000 40BP 1/4" Pressure microphone 500 0-500 -1000-1500 0.1 0.125 0.15 0.175 0.2 Time [ms] 40AF 1/2 Free field Microphone 1500 1000 40AF 1/2" Free field microphone 500 0-500 -1000-1500 0.1 0.125 0.15 0.175 0.2 Time [ms] Fig. 10. Signals from 4 different microphones Figure 10 shows a comparison of the results from the four microphones. It can be seen that the response from the 40BF ¼ Microphone is very similar to the result from the ⅛ microphone, the main difference being the under-estimation of the peak value by the 40BF, while the signals from the other two microphones are very different from the two first signals. Analyzing the signals with the Short-time Fourier Transform program in the National Instruments Sound and Vibration package for Labview gives detailed information about the signals both in the frequency and time domains, see Fig. 12 on page 12. 10

a) 40DP 1/8 microphone b) 40BF 1/4 microphone Frequency [Hz] Frequency [Hz] c) Time [s] 40BP 1/4 microphone Amplitude Amplitude Frequency [Hz] Frequency [Hz] d) Time [s] 40AF 1/2 microphone Amplitude Amplitude Time [s] Time [s] Fig. 11. Colourmaps of STFT for four different transducer signals It can be seen that the ⅛ microphone measures the impulse with a frequency range up to 140 khz, covering essentially the full useful frequency range of the microphone. It might be that using a microphone with an even wider frequency range would reveal frequency content in the pulse of even higher frequencies, but it is not very likely that it will contain much energy above the present frequency range. The 40BF ¼ Microphone in figure 11b has upper frequency limits around 80 khz, while the 40BP and 40AF records very little of the impulse in the signal. Looking closer at the time signal around the impulse for the four transducer signals as in figure 12, reveals details about signals measured by the different transducers. a) 40DP ⅛ Microphone b) 40BF ¼ Microphone c) 40BP ¼ Microphone d) 40AF ½ Microphone In general the signals from the four transducers follow the same trend. The biggest difference occurs at the peak, where the 40DP ⅛ microphone estimates a peak value of 1345 Pa, while the 40BF 11

Pascal [Pa] 1500 1000 1/8" Microphone Type 40DP 1/4" Microphone Type 40BF 1/4" Microphone Type 40BP 1/2" Microphone Type 40AF 500 0-500 0.108 0.10825 0.1085 0.10875 Time [s] Fig. 12. Time signals from the four different transducers ¼ microphone gives 943 Pa. This is caused by the limited bandwidth of the 40BF ¼ microphone and not problems with handling the dynamic range of the impulse. The steep pulse measured by the ⅛ microphone has a duration of around 5μs corresponding to a wave front width of around 1.7 mm, assuming a sound velocity of 340 m/s. This means that the wave front will travel across the diaphragm of the 40BP ¼ microphone as this microphone was placed perpendicular to the wave front direction. The microphone has an effective back plate diameter of approximately 3.5 mm, so the wave front will excite only a small part of the diaphragm. The impulse as recorded with the 40BP will therefore be a smoothed version of the peak. The 40AF ½ free field microphone misses the impulse completely. Partly because the frequency range of the microphone is limited to 20 khz and partly because the diaphragm area is large compared to the length of the wavefront. The very short wavefront cause the diaphragm to break up, so that the diaphragm does not move in a regular well defined pattern, but so that different parts of the diaphragm moves in chaotic patterns at high frequencies. This can be seen as very high frequency ripple or noise on the signal from the 40AF shortly after the impulse signal. The peak value measured for the steering wheel type airbag was measured to 1345 Pa. Much higher peak values were measured for a passenger side airbag. As shown in Fig. 13 on page 13, the full airbag deployment takes about 75 ms with peak values up to 6000 Pa. The initial part of the airbag signal is characterize by a general pressure increase superimposed with a number of short impulses. After the initial pressure increase follows a negative pressure superimposed with a high positive 12

Fig. 13. Pressure signal from passenger side airbag as recorded with 40DP 1/8 Pressure microphone. peak impulse. While the impulses are very high, they are still well below the handling capacity of the microphone and preamplifier of up to around 70.000 Pa or 20 db higher. Conclusion To measure the steep impulse of an airbag deployment requires a small transducer able to handle very high frequencies. An ⅛ measurement microphone has a size and frequency range able to measure the very short wave fronts and capture the high frequencies. The use of high speed simultaneous sampling and effective data processing tools enables detailed investigation of the signal and correlation with the physical phenomenon and high speed recordings. 13