Low Capacitance Probes Minimize Impact on Circuit Operation

Similar documents
Passive Voltage Probes

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Measuring Power Supply Switching Loss with an Oscilloscope

20X Low Capacitance Probe P6158 Datasheet

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

High-voltage Differential Probes

Stress Calibration for Jitter >1UI A Practical Method

Fundamentals of AC Power Measurements

10 GHz Linear Amplifier PSPL5866 Datasheet

1.5 GHz Active Probe TAP1500 Datasheet

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

P7500 Series Probes Tip Selection, Rework and Soldering Guide

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

AC Current Probes CT1 CT2 CT6 Data Sheet

Power Measurement and Analysis Software

30 A AC/DC Current Probe TCP0030A Datasheet

Measuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Soldering a P7500 to a Nexus DDR Component Interposer

AC/DC Current Probe TCP0150 Datasheet

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Isolation Addresses Common Sources of Differential Measurement Error

12.5 Gb/s Driver Amplifier PSPL5865 Datasheet

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Measuring Wireless Power Charging Systems for Portable Electronics

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Differential Probes P6248 P6247 P6246 Datasheet

TriMode Probe Family P7700 Series TriMode Probes

Measurement Statistics, Histograms and Trend Plot Analysis Modes

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

High-impedance Buffer Amplifier System

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Be Sure to Capture the Complete Picture

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Passive High Voltage Probes P5100 P5102 P5120 P6015A

Advanced Test Equipment Rentals ATEC (2832)

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

Tektronix Logic Analyzer Probes P6800/P6900 Series Datasheet

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet

P7600 Series TriMode Probes

Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

Time and Frequency Measurements for Oscillator Manufacturers

100GBASE-KR4/CR4 & CAUI-4 Compliance and Characterization Solution

Z-Active Differential Probe Family P7313 P7380A P7360A P7340A Datasheet

TriMode Probe Family. P7500 Series Data Sheet. Features & Benefits. Applications

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

Understanding Oscilloscope Bandwidth, Rise Time and Signal Fidelity

KickStart Instrument Control Software Datasheet

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

DPO7OE1 33 GHz Optical Probe

Programmable Pulse/Pattern Generator PSPL1P601 and PSPL1P602 Datasheet

Replicating Real World Signals with an Arbitrary/Function Generator

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

Choosing an Oscilloscope for Coherent Optical Modulation Analysis

S540 Power Semiconductor Test System Datasheet

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

16 Gb/s, 30 Gb/s Gb/s, and 32 Gb/s Programmable PatternPro Pattern Generator PPG PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Visual Triggering. Technical Brief

30 Gb/s and 32 Gb/s Programmable Pattern Generator PPG Series Datasheet

Using the Ramp Rate Method for Making Quasistatic C-V Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

100GBASE-KR4, 100GBASE-CR4, & CAUI-4 Compliance and Characterization Solution for Real Time Scopes

TriMode Probe Family. P7500 Series Datasheet. Features & Benefits. Applications

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

Using the 4200A-CVIV Multi-Switch to Make High Voltage and High Current C-V Measurements APPLICATION NOTE

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

S540 Power Semiconductor Test System Datasheet

Switching Between C-V and I-V Measurements Using the 4200A-CVIV Multi-Switch and 4200A-SCS Parameter Analyzer APPLICATION NOTE

e-guide to RF Signals UNLICENSED & ISM BANDS LAND MOBILE & PUBLIC SAFETY CELLULAR AERONAUTICAL RADIO & TELEVISION BROADCAST WEATHER RADAR

Basics of Using the NetTek YBA250

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Notice to EU customers

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

If I Could... Imagine Perfect Vision

Active Power Factor Correction Verification Measurements with an Oscilloscope APPLICATION NOTE

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

Understanding AWG70000A Series Frequency Response and DAC Performance

Arbitrary/Function Generator AFG1000 Series Datasheet

Arbitrary Function Generator AFG1022 Datasheet

Creating Calibrated UWB WiMedia Signals

AC/DC Current Measurement Systems

Arbitrary Function Generator AFG1000 Series Datasheet

Advanced Power Measurement and Analysis 5 Series MSO Option 5-PWR Datasheet

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Advanced Statistical Analysis Using Waveform Database Acquisition

Automotive EMI/EMC Pre-compliance Tests

Performing Cyclic Voltammetry Measurements Using Model 2450-EC or 2460-EC Electrochemistry Lab System

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

AC/DC Current Measurement Systems

10GBASE-KR/KR4 Compliance and Debug Solution

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Making Accurate Current Measurements on Power Supplies with Oscilloscopes APPLICATION NOTE

PA1000 Single Phase AC/DC Power Analyzer Datasheet

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Transcription:

Presented by TestEquity - www.testequity.com Low Capacitance Probes Minimize Impact on Circuit Operation Application Note

Application Note Traditional Passive Probe Advantages Wide dynamic range Inexpensive Mechanically rugged High input resistance Traditional Passive Probe Disadvantages Low bandwidth High input capacitance Requires manual low frequency compensation High frequency compensation requires manufacturer s service Table 1. Traditional Passive Probe Advantages and Disadvantages. Tektronix TPP1000, TPP0500B, & TPP0250 Advantages Traditional Passive Probe Disadvantages Reduced Cost of Ownership Improved Measurement Accuracy Reduced Setup Time Wide dynamic range Inexpensive Mechanically rugged Up to 1 GHz bandwidth Low input capacitance High input resistance Automated low frequency compensation Automated high frequency compensation Low bandwidth High input capacitance Requires manual low frequency compensation High frequency compensation requires manufacturer s service Table 2. Tektronix TPP1000, TPP0500B, and TPP0250 Advantages. Introduction This application note describes how the high bandwidth, low capacitance passive voltage probes from Tektronix reduce the oscilloscope user's total cost of ownership, improve performance and measurement accuracy, and save the user setup time. Passive voltage probes that ship standard with most oscilloscopes provide a low cost, general purpose probing solution. Generally, these probes lack the performance of an active voltage probe but provide the ruggedness and wide dynamic range suitable for visualizing signals. Table 1 describes the advantages and disadvantages of traditional passive probe solutions. The TPP1000, TPP0500B, and TPP0250 redefine performance in the passive probe product category, with specifications previously unrealized in this product class. These probes are designed for use with Tektronix MDO3000, MDO4000B, MSO/DPO4000B, and MSO/DPO5000 Series oscilloscopes. This level of performance is obtained through the combination of circuitry within the oscilloscope and the probe. The improvements in bandwidth, input capacitance and automated probe compensation turn traditional passive probing disadvantages into advantages as shown in Table 2. This application note will describe in more detail: Reduced Cost of Ownership Improved Measurement Accuracy Reduced Setup Time 2 www.tektronix.com/probes

Low Capacitance Probes Minimize Impact on Circuit Operation Reduced Cost of Ownership The limitations of standard passive probes, especially on 1 GHz systems, force the user to purchase active probes which significantly increases the overall investment cost. The TPP1000, TPP0500B, and TPP0250 probes from Tektronix bridge the gap between traditional passive probes and higher performance, higher cost active probes. Tektronix is the only vendor to match the probe bandwidth to the scope bandwidth at 1 GHz. With industry leading passive probe specifications and automated low and high frequency compensation, the TPP1000, TPP0500B, and TPP0250 reduce the user's total cost of ownership and make the oscilloscope investment even more valuable. Improved Measurement Accuracy Several factors affect how well a probe can deliver a signal to the oscilloscope, and the user should consider: Performance specifications: What is the probe's bandwidth and rise time? Low input capacitance at the probe tip: How do the probe's accessories affect performance? Probe loading: How much does the probe load the signal at the test point? www.tektronix.com/probes 3

Application Note Figure 1. Rise Times of Tektronix, LeCroy, and Agilent Standard Passive Voltage Probes. Performance Specifications General purpose passive probes favor ruggedness over performance. This trade-off has long sufficed because these probes have been mainly used to visualize low-speed signals. This trade-off has also been made because of the significant design challenges in creating a probe that is rugged, high performance, and capable of measuring hundreds of volts. Active probes typically start at 1 GHz bandwidth, measure less than 10 V (though some Tektronix probes go up to 40 V), and lack the robustness of a passive probe. Passive probes are typically 500 MHz or less, measure hundreds of volts, and are rugged. The TPP1000, TPP0500B, and TPP0250 are the only probes that offer performance, wide dynamic range and the ruggedness required for daily use. The banner performance specification for oscilloscopes and probes is bandwidth. Bandwidth is a measure of frequency response, and oscilloscopes are primarily time-domain instruments. The data displayed on an oscilloscope is a graph of amplitude versus time and differences that look small in the frequency domain can have a big impact in the time domain. Most oscilloscope users need an oscilloscope and probe with excellent step response because it is a better indication of what the output of the probe will look like on the oscilloscope display. To properly show the system step response, a fast, clean step signal is injected into the measurement system. Probe rise time evaluation requires a signal with a faster edge rate than the probe is capable of. Consider the screen shots in Figure 1 which compare the rise time of the TPP1000 probe from Tektronix and passive probes that ship standard from LeCroy and Agilent. Each probe was attached to the same test fixture utilizing the probe's short ground spring for optimum performance. As shown in the screen shots above, a fast, clean step signal with a 240 ps rise time was established as the reference to compare the probe's step response against. The reference signal is identified as R1 and is the white trace. The TPP1000 from Tektronix has the fastest rise time (443.6 ps), has a waveform with the same amplitude and shape as the reference with minor overshoot. The TPP1000 is the passive probe most capable of capturing signals with fast edge rates. 4 www.tektronix.com/probes

Low Capacitance Probes Minimize Impact on Circuit Operation Figure 2. Rise Times of Standard Passive Voltage Probe with Long Ground Leads Attached. Low Input Capacitance at the Probe Tip Because standard passive probes are primarily used to visualize signals, most users attach a long probe ground lead to a ground connection. A long ground lead makes it easier to move the probe around the board to various test points without having to attach and re-attach the ground connection. Short ground springs provide the best performance but ground may not always be within the spring's range. Long ground leads, those that are 6" or longer, make obtaining a ground connection easier, but long ground leads reduce performance due to the added inductance. As the length of the ground lead increases, the inductance added into the measurement increases. Inductance and capacitance are related to frequency and as the probe's inductance and capacitance increases, the probe's performance decreases. For example, a probe with a 6" ground lead attached is capable of greater performance and accuracy than the same probe with a 12" ground lead attached. To address the performance issues caused by ground leads, the options are to reduce the inductance by using shorter ground leads or to find a probe with lower input capacitance. The TPP1000, TPP0500B, and TPP0250 offer < 4 pf input capacitance at the probe tip compared to 9.5 pf input capacitance offered in other standard passive probe offerings. With these Tektronix passive probes, users can attach longer ground leads without suffering the signal degradation from probes with higher input capacitance. Figure 2 shows the step responses of Tektronix, LeCroy and Agilent standard passive probes with a long probe ground lead attached. The performance impact of adding long probe ground leads is substantial. The probe's rise time decreases and the output signal has ringing, increased overshoot, and greater amplitude inaccuracy. The TPP1000, TPP0500B, and TPP0250 offer users the convenience of using longer probe grounds when visualizing signals without suffering significant loss in performance and accuracy. www.tektronix.com/probes 5

Application Note Figure 3. Probe Loading Impacts of Standard Passive Voltage Probe. Probe Loading A passive probe's input capacitance and input resistance at the probe tip specification is important because it affects the circuit under test. When an external device, such as a probe is attached to a test point, it will appear as an additional load on the signal source drawing current from the circuit. This loading, or signal current draw, changes the operation of the circuitry behind the test point and changes the signal seen at the test point. The ideal probe would have infinite impedance, but this is not possible because a probe must draw some small amount of signal current in order to develop a signal voltage at the oscilloscope input. A probe will always induce some signal source loading; the challenge is to keep this as low as possible. The loading of greatest concern is caused by the capacitance at the probe tip. For low frequencies, this capacitance has a reactance that is very high and has little or no effect on the circuit under test. As frequency increases, the capacitive reactance decreases and at higher frequencies, the capacitive loading is higher. Capacitive loading affects the bandwidth and rise time characteristics of the measurement system by reducing bandwidth and increasing rise time. The TPP1000, TPP0500B, and TPP0250 offer significantly lower input capacitance than any existing high impedance general purpose passive probe. The input capacitance at the probe tip for these probes is < 4 pf, notably lower than the 9.5 pf offered in non-tektronix probes. Figure 3 shows the probe loading of the Tektronix TPP1000 to standard offerings from LeCroy and Agilent. The white trace is the input signal waveform and the other traces show how the reference waveform changes when probes are attached to the test point. It is important to remember that the waveforms shown in this image are not the output of the probe, but they show how the probe affects the signal at the test point. The blue trace shows the minimal loading impact of the TPP1000 on the source signal as it closely matches the reference waveform and has minimal impact on rise time. The effects of the additional input capacitance of the non-tektronix probes have an impact on performance and accuracy. As stated above, capacitance reactance decreases at higher frequencies, and the capacitive loading has a greater impact as frequency increases. A higher capacitance probe will have greater loading at higher frequencies which explains the rounded front corner on the LeCroy and Agilent loading signals; the front edge is where the high frequency content of the square wave is located. When probing faster signals, non-tektronix probes will more significantly distort the source signal and create measurement inaccuracy. 6 www.tektronix.com/probes

Low Capacitance Probes Minimize Impact on Circuit Operation Low Frequency Compensation Undercompensated Properly compensated Overcompensated Figure 4. Low Frequency Probe Compensation. Figure 5. High Frequency Probe Compensation. Reduced Setup Time Due to variations in the probe and oscilloscope input characteristics, general purpose passive probes require low frequency compensation. The user may not be aware that low frequency compensation is required, may forget about this procedure, or may forgo low frequency compensation to save time. As shown in Figure 4, the probe output has to be compensated using an adjustment tool until the response is flat as shown in the "Properly compensated" example below. While low frequency compensation is a necessary and a common user adjustment on all passive probes, high frequency compensation typically requires the adjustment to be performed by the manufacturer's service department. High frequency compensation adjustment points are typically not user accessible and may require the user to damage outer labels on the compensation box to obtain access. This compensation may also require special equipment such as a calibration generator and special probe adapters to make the necessary adjustments. High frequency compensation corrects aberrations to leading edge and long term flatness as shown in Figure 5. www.tektronix.com/probes 7

Application Note Figure 6. Automated Low and High Frequency Probe Compensation. The TPP1000, TPP0500B, and TPP0250 when connected to a compatible Tektronix oscilloscope are capable of automated low frequency and high frequency compensation. It takes less time to compensate a TPP1000, TPP0500B, and TPP0250 for both high and low frequency compensation than the time required to manually adjust a standard passive probe for low frequency compensation. With a TPP1000, TPP0500B, and TPP0250, the probes may be easily compensated when first attaching a probe to a channel by holding the probe tip and ground to the oscilloscope's PROBE COMP pins and selecting "Compensate Probe for <channel number>". Example selections are shown in Figure 6. The procedure takes less than five seconds and the compensation results are stored in the oscilloscope in case the probe is removed and re-attached. The oscilloscope is capable of storing results for multiple probes for each channel. 8 www.tektronix.com/probes

Low Capacitance Probes Minimize Impact on Circuit Operation Pogo Pin The TPP1000, TPP0500B, and TPP0250 ship standard with replaceable rigid tip and pogo pin cartridges. The pogo pin tip is spring loaded and it takes less compression on the pin to establish good electrical contact which means that the user does not have to press down as hard on the probe tip. The force required to make good contact is an important aspect for a couple of reasons. First, the user does not have to focus on keeping his hand in the right position while operating the oscilloscope. With the pogo pin installed, the probe maintains constant pressure and provides the user some give in the pressure required to make good contact and is more comfortable when the probe is being used to visualize signals. Also, users have a tendency to push down harder on the probe when good contact is not made or if the signal does not appear on the oscilloscope as expected. This increase in force may cause the probe to inadvertently slip off the test point and make inadvertent contact with adjacent signals which could damage the test equipment or the device under test. Conclusion The TPP1000, TPP0500B, and TPP0250 redefine performance in the passive probe product category, with specifications previously unrealized in this product class, turning traditional passive probing disadvantages into advantages. These probes bridge the gap between general purpose passive probes and higher cost active probes by providing the best of both technologies: high performance; low cost; capable of measuring dynamic range in the hundreds of volts; low input capacitance; and the ruggedness required for daily use. With industry leading passive probe specifications and automated compensation, the TPP1000, TPP0500B, and TPP0250 reduce the user's total cost of ownership and add tremendous value to the oscilloscope investment. www.tektronix.com/probes 9

Contact Tektronix: ASEAN / Australia (65) 6356 3900 Austria* 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3759 7627 Canada 1 (800) 833-9200 Central East Europe and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400-820-5835 Ireland* 00800 2255 4835 India +91-80-30792600 Italy* 00800 2255 4835 Japan 0120-441-046 Luxembourg +41 52 675 3777 Macau 400-820-5835 Mongolia 400-820-5835 Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Middle East, Asia and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 Norway 800 16098 People s Republic of China 400-820-5835 Poland +41 52 675 3777 Portugal 80 08 12370 Puerto Rico 1 (800) 833-9200 Republic of Korea +822-6917-5000 Russia +7 495 664 75 64 Singapore +65 6356-3900 South Africa +27 11 206 8360 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886-2-2656-6688 United Kingdom* 00800 2255 4835 USA 1 (800) 833-9200 * If the European phone number above is not accessible, please call +41 52 675 3777 Contact List Updated June 2013 For Further Information Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com Copyright 2014, Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 01/14 EA/WWW 51W-26294-3