GAMMA 12 DIGITAL MULTIMETER

Similar documents
GAMMA 10 DIGITAL MULTIMETER

Technical Data Sheet. Gamma 12. Gamma 12

RISH Multi 12S...18S Analog - Digital multimeters

Data Sheet. Analog - Digital Multimeter. RISH Multi RISH Multi Analog-Digital Multimeter. Page 1 of 6. Rishabh Instruments

GAMMA 20 DIGITAL MULTIMETER

SUBJECT TO CHANGE WITHOUT NOTICE

Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Technical Data Sheet. Delta 1000/300

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

Technical Data Sheet. Zeta 20

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement

METRA 22 26S/M Analog-Digital Multimeters with Signal Generator

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577 Insulation Multimeters

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

USER'S MANUAL DMR-6700

APPA 300 Series. The Most User-Friendly High Performance Multimeter

METRAClip87 and 88 Clamp Multimeters

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Fluke 83V and 87V Digital Multimeters

79/26 Series III Multimeter

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

BENCH METER Model>9803. Wavecom Instruments

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Autoranging Multimeter Extech EX503

Insulation Testers and Earth Ground Testers

METRAHit 30M Precision Digital Multimeter

DVM1190 DIGITAL MULTIMETER

Current Clamp. 210

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

OPERATOR S INSTRUCTION MANUAL

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

# Digital Multimeter

Digital-Multimeter UNIGOR 380, 390

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Digital-Multimeter UNIGOR 380, UNIGOR 390

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Data sheet IDM 99III Digital Multimeter

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Data sheet IDM 98III Digital Multimeter

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

METRAClip85 and 86 Clamp Multimeters

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

N24, N25 DIGITAL PANEL METER

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Indeks: WMXXCMM60 Advanced Industrial Multimeter

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

AC/DC CLAMP METER USER S MANUAL

SAFETY PRECAUTIONS: Before use, read the following safety precautions

Fluke 1587 FC/1577 Insulation Multimeters

NOTE: Fully read and understand this manual before using this Digital Multimeter.

METRAVI. Table of Contents

400Amp True RMS AC/DC Clamp Meter Model EX613

The Meter Structure The Figure 2-1 shows the Meter structure.

BENNING. CM7 Electrical Tester. Service Information

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

1507/1503. Insulation Testers. Technical Data. Features and benefits:

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

METRA HIT 28C Calibrator, Multimeter and Milliohmmeter

User s Guide. 400A AC/DC Clamp Meter. Model MA220

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Agilent 970-Series Handheld Multimeters Data Sheet

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

True RMS Digital Multimeter Model:

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

OPERATING INSTRUCTION

SDM3045X Digital Multimeter. DataSheet

Model 77 Series IV. Digital Multimeter. Users Manual

Instruction Manual IDM 66RT Digital Multimeter

1507/1503. Insulation Testers. Users Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

Sales: Technical: Fax:

200Amp AC Clamp Meter + NCV Model MA250

Digital Multimeter with Backlight

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

METRA HIT 22 26S/M Analog-Digital Multimeters with Signal Generator

DIGIT & POINTER MULTIMETER

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

Transcription:

Gamma 12 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts Digital Multimeters GAMMA 12 DIGITAL MULTIMETER Gamma 12. An Analog Digital Multimeter which measures VAC, VDC, AC+DC, Frequency, ma DC, ma (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Features Automatic terminal blocking system (ABS) Min/Max value storage Indication of negative values on the analogue scale Overload warning Clamp Meters Insulation Testers SUBJECT TO CHANGE WITHOUT NOTICE This manual superseded all previous versions please keep for future reference

Application Gamma 12 is the Analog Digital Multimeter which measures VAC, VDC, VAC+DC,Frequency, ma DC, ma (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Product Features Automatic Terminal Blocking System (ABS) Interface And Software RISH com 100 MIN / MAX Value Storage Indication Of Negative Values On The Analogue Scale Indication Of Negative Values On The Analogue Scale Automatic Data Hold* Autoranging / Manual Range Selection The automatic Terminal blocking system prevents incorrect connection of the test leads and incorrect selection of the measured quantity. This reduces danger to the user, the meter and the system to a remarkable extent. The multimeters are fitted with a serial RS-232 C interface via which the measured values can be transmitted to a PC. These values, electrically isolated, are transmitted to the attachable interface adaptor with infrared light through the case* In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated and stored. When measuring DC quantities, also negative values are shown on the analogue scale so that variations of the measured value can be observed at the zero point. The measuring principle employed permits the measurement of the root-mean-square value (TRMS) of AC quantities and mixed quantities (AC and DC) regardless of the waveform. The DATA HOLD function makes it possible to hold the digitally displayed measured value. According to a patented method, it is ensured that no freak value but the actual measured value is held in the case of rapid changes in measured quantities. The held measured value appears on the digital display. The actual measured value continues to be shown on the analogue scale. The measured values are selected with rotary switch. The measuring range is automatically matched to the measured value. The measuring range can also be selected manually via the AUTO/MAN push button Continuity Test This permits testing for short circuit and open circuit. In addition to the display, a facility of sound signal is available. Temperature It is possible to use all models of Gamma 12, Measurement in direct connection of temperature sensor Pt 100 / Pt 1000. The meters automatically detects the type of sensors connected to it & displays directly measured temperature. Signalling in the The display FUSE points to a blown fuse. case of a blown fuse Power The meter disconnects automatically when the economizing circuit measured value remains unchanged for about 10 minutes and no operating control was operated during this time. The disconnection facility can be disabled. Overload A sound signal indication violation of the Warning overload limits. Protective A holster of soft rubber with tilt stand protects holster for rough the meter against damage in the case of shock duty and drop. The rubber material makes for the meter to stand firmly even on vibrating surface. Top model The top model Gamma 12 features a 4 3/4 Gamma 12 Calibration digit display (31 000 digits)as well as the following additional functions : Event counter, measurement of the duration of the event, time counter (stop watch), data compare, db measurement, wide-range capacitance measurement. Gamma mutli is automatically calibrated with respect to Fluke 5500 / Wavetek 9100. Automatic calibration is done through a developed calibration software with RS232 connection to the multimeter. Every multimeter is provided with the Test Certificate which is traceable to National / International standards. All the meters can be recalibrated at the Rishabh Instruments. Issue 1.0 Gamma 12 1

Technical Specifications Analogue Indication LCD scale with pointer Scale length 55 mm on V and A ; 47 mm on all other ranges Scaling + 5 0 + 30 with 35 scale divisions on 0 30 with 30 scale divisions on all other ranges Polarity indication With automatic reversal Overrange indication By triangle Sampling rate 20 readings/s, On Ω 10 readings/s Environmental conditions Temperature range -10 C... + 50 C Storage temperature -25 C... +70 C (excl. batteries) range Climatic class 2z/-20/50/70/75% with reference to VDI/VDE 3540 Altitude above sea level up to 2000m Digital Display/ height of 7 segment numerals / 15mm numerals Number of counts Gamma 12 3 ¾ digit 31000 counts Gamma 10 4 ¾ digit 31000 counts Overange display "OL" is shown Polarity display "-" sign is shown, When positive pole to 1 Sampling rate 2 readings/s, On Ω and 0C:1 reading/s Mechanical Configuration Protection type For meters; IP 50, for connection sockets: IP 20 Dimensions 84 mm x 195 mm x 35 mm Weight 0.35 kg, approx., incl. battery Applied rules and standards IEC 61010-1:2001 Safety requirements for electrical DIN EN 61010 part 1 equipment for measurement, VDE 0411-1 control and laboratory use. DIN 43751 IS 13875 Digital measuring instruments EN 61326:2002 Generic emission standard; Residential, commercial and light industry EN 61326:2002 Generic immunity standard; residential, commercial and light industry VDI/VDE 3540 Reliability of measuring and control equipment. DIN EN 60529 Test equipment and test procedures DIN VDE 0470 part 1 -Degrees of protection provided by enclosures (IP Code) Warranty 3 year against defects in materials and workmanship & calibration from the date of purchase. Scope of delivery 1 multimeter 1 Probe Set 1 copy of operating instructions 1 test certificate 1 rubber holster with tilt stand and carrying strap warranty card 1 set of extra fuses Display LCD field (65 mm x 30mm) with analogue indication and digital display and with annuciators for unit of measurement, function and various special functions. 2 Gamma 12 Issue 1.0

Technical Specifications Meas. Measuring range Resolution Input impedence Inherent deviation of the function digital display+ (...% of Overload capacity 4) meas. val. +...digits) for reference condition Overload Overload Meas. value duration function 30.00 mv 10 µv > 10GΩ // < 40 pf 0.5 + 3 5) 300.0mV 100 µv > 10GΩ // < 40 pf 0.5 + 3 3.000 V 1 mv 11MΩ // < 40 pf 0.1 + 1 V 30.00 V 10 mv 10MΩ // < 40 pf 0.1 + 1 V 300.0 V 100 mv 10MΩ // < 40 pf 0.1 + 1 1000 V 1000 V 1V 10MΩ // < 40 pf 0.1 + 1 DC 3.000 V 1) 1 mv 11MΩ // < 40 pf AC cont. 30.0 V 1) 10 mv 10MΩ // < 40 pf 0.75 + 3 effective V 300.0 V 1) 100 mv 10MΩ // < 40 pf (> 10 D) sinusoidal V 1000 V 1) 1 V 10MΩ // < 40 pf 3.000 V 1) 1 mv 11MΩ // < 40 pf V 30.00 V 1) 10 mv 10MΩ // < 40 pf 0.75 + 3 V 300.0 V 1) 100 mv 10MΩ // < 40 pf (> 10 D) 1000 V 1) 1 V 10MΩ // < 40 pf Voltage drop. approx. 300.0µ A 100 na 15 mv 0.5 + 5 (> 10 D) 3.000 ma 1µ A 150 mv 0.5 + 2 0.36 A cont. A 30.00 ma 10 µa 650 mv 0.5 + 5 (> 10 D) A 300.0 ma 100 µa 1 V 0.5 + 2 3.000 A 1 ma 100 mv 0.5 + 5 (> 10 D) 7) 7) 10.00 A 10 ma 270 mv 1.0 + 2 3.000 ma 1 µa 150 mv --- 0.36 A cont. A 30.00 ma 10 µa --- --- A 300.0 ma 100 µa 1 V --- 7) 7) 10.00 A 10 ma 270 mv --- A 30.00 A 2) 10 ma --- --- 0.36 A cont. A 300.0 A 2) 100 ma --- --- 3.000 ma 1) 1 µa 150 mv 1.5 + 4 (> 10 D) A 300.0 ma 1) 100 µa 1 V 1.5 + 4 (> 10 D) 12 A 10 min A 10.00 A 1) 10 ma 270 mv 1.75 + 4 (> 10 D) Issue 1.0 Gamma 12 3

Technical Specifications Meas. Measuring range Resolution Input impedence Inherent deviation of the function digital display+ (...% of Overload capacity 4) meas. val. +...digits) for reference condition Overload Overload Meas. value duration function No-load voltage 30.00Ω 10 m max. 3.2 V 0.4 + 3 5) 300.0Ω 100 m max. 3.2 V 0.4 + 3 3.000 kω 1 max. 1.25 V 0.2 + 1 1000V Ω 30.00 kω 10 max. 1.25 V 0.2 + 1 DC 10 min Ω 300.0 kω 100 max. 1.25 V 0.2 + 1 AC 3.000 MΩ 1 k max. 1.25 V 0.4 + 1 effective 30.00 MΩ 10 k max. 1.25 V 0.2 + 1 sinusoidal 2.000 V 1 mv max. 3.2 V 0.1 + 1 Discharge U 0 max resistance 30.00 nf 10 pf 250 k 2.5 V 1.0 + 3 6) 1000 V 30.00 nf 100 pf 250 k 2.5 V 1.0 + 3 DC F 30.00 µf 1 nf 25 k 2.5 V 1.0 + 3 AC 10 min F 30.00 µf 10 nf 25 k 2.5 V 3.0 + 3 effective sinusoisal Sensor F min V F minv 300.0 Hz 0.1 Hz 1 Hz 45 Hz 3 khz: Hz 3.000 khz 1 Hz 1 Hz 45 Hz 0.5 + 1 8) 1000V 30.00 khz 10 Hz 10 Hz 45 Hz 30 khz: Hz 100.0 khz 100 Hz 100 Hz 100 Hz 300V cont. % 2.0... 98.0 % 0.1% 1 Hz --- 1 Hz...1kHz: + 5 D 8) 100 khz: 1Hz...10kHz:+5 D/kHz 9) 30 V - 200.0... 0.1 C --- --- 2 Kelvin + 5 D 10) + 200.0 C Pt 100 1000 V + 200.0... 0.1 C --- --- 1.0 + 5 10) DC C + 850.0 C AC 10 min C -100.0... 0.1 C Pt100 --- --- 2 Kelvin + 2 D 10) effective + 200.0 C sinusoidal + 200.0... 0.1 C --- --- 1.0 + 2 10) + 850.0 C 1) TRMS measurement 2) Direct display with clip-on transformer 1000:1 4) At 0 C... + 40 C 5) With zero setting; w/o zero setting + 35 digits 6) With zero setting; w/o zero setting + 50 digits 7) Gamma 12 (w/o 16 A fuse!) : 16A cont., 20A for 5 min; Gamma 12 : 12A for 5 min, 16A for 30s 8) Range 3 V : U = 1.5 VE rms... 100 Vrms 30 V : U = 15 VE rms... 300 Vrms 300 V : U = 150 VE rms... 1000 Vrms 9) On the range 3V rectangular signal positive at one end 5... 15 V, f = const., not 163.84 Hz or integer multiple. 10) Without sensor 4 Gamma 12 Issue 1.0

Measuring voltage with resistance measurement Voltage Ux across the resistance Rx to be measured as a function of measuring range and display. Measuring current with diode test and / or continuity test Measuring current Ix as a function of the displayed voltage Ux on the device under test. Issue 1.0 Gamma 12 5

Influence quantities and variations Influence Influence Measured quantity / Variation 1) quantity range measuring range ± (...% of meas. val. ±...digits) 30/300 mv 1.0 + 1 3... 300 V 0.1 + 1 1000 V 0.1 + 1 V 0.3 + 2 300 µ A 2... 0.15 + 1 300 ma 3A / 10 (16) A 0 C... + 21 C A 0.75 + 3 Temperature and 30 Ω 0.15 + 2 +25 C... + 40 C 300 Ω 0.15 + 2 3 k...3 MΩ 0.1 + 1 30 MΩ 0.6 + 1 30 nf 2)... 3µF 0.5 + 2 30 µf 2.0 + 2 Hz 0.5 + 1 % ± 5 D -200... + 20 0 C 0.5 K + 2 + 200... + 8 50 C 0.5 + 2 15 Hz... < 30 Hz 1.0 + 3 30 Hz... < 45 Hz 0.5 + 3 > 65 Hz... 400Hz 3...300 V 0.5 + 3 Frequency of the > 400 Hz... 1 khz 1.0 + 3 measured quantity > 1kHz... 20 khz 2.0 + 3 15 Hz... < 30 Hz 1.0 + 3 30 Hz... < 45 Hz 1000 V 0.5 + 3 > 65 Hz... 1kHz 2.0 + 3 15 Hz... < 30 Hz 1.0 + 3 30 Hz... <45 Hz A 0.5 + 3 > 65 Hz...1kHz 3.0 + 3 ± 1% Crest factor CF 1...3 > 3...5 V 4), A 4) of rdg. ± 3% of rdg. The permissible crest factor CF of the AC quantity to be measured is a function of the displayed value : Waveform of the measured quantity 3) 6 Gamma 12 Issue 1.0

Influence quantities and variations Influence Influence Measured quantity / Variation 1) quantity range measuring range ± (...% of meas. val. ±...digits) V + 2D V + 4 D A + 4D Battery voltage 5)... < 7.9 V A + 6 D > 8.1 V... 10.0 V 30Ω / 300Ω / ºC + 4 D 3 kω... 30 MΩ + 3 D nf, µf + 1 D Hz + 1 D % + 1 D V 75 % A Relative humidity 3 days Ω 1x Intrinsic error Meter off F Hz % DATA C ±1 D MIN / MAX V, A ± 2 D 1) With temperature; Error data is per 10 K change in temperature. With frequency; Error data is valid from a display of 300 digits. 2) With zero setting 3) With unknown waveform (crest factor CF > 2), the measurement must be made with manual range selection. 4) Except for sinusoidal waveform 5) From the time the symbol appears. Issue 1.0 Gamma 12 7

Operating controls Ordering Information GM20-6NB4000000000 GM20-6FB4000000000 GAMMA 12 Gamma 12 TRMS Backlit Gamma 12 TRMS Fine Tip TRMS Backlit Contact Sifam Tinsley Instrumentation Ltd 1 Warner Drive Springwood Industrial Estate Braintree, Essex CM7 2YW Tel: 01376 335271 E-mail: sales@sifamtinsley.com www.sifamtinsley.co.uk 8 Gamma 12 Issue 1.0