GAMMA 20 DIGITAL MULTIMETER

Similar documents
SUBJECT TO CHANGE WITHOUT NOTICE

Analog Digital Multimeter with Insulation Resistance Measurement

GAMMA 12 DIGITAL MULTIMETER

GAMMA 10 DIGITAL MULTIMETER

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Technical Data Sheet. Gamma 12. Gamma 12

Technical Data Sheet. Delta 1000/300

Technical Data Sheet. Zeta 20

Data Sheet. RISH Max-14 Analog-Digital Multimeter. RISH Max-14 Analog-Digital Multimeter. Page 1 of 5. Rishabh Instruments 1 / 05 / IX / 1210 / B

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement

RISH Max-12 and 14 Analog-Digital Multimeter. Data Sheet. RISH Max-12 and 14 Analog-Digital Multimeter. Rishabh Instruments

1587/1577 Insulation Multimeters

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Data Sheet. Analog - Digital Multimeter. RISH Multi RISH Multi Analog-Digital Multimeter. Page 1 of 6. Rishabh Instruments

Indeks: WMXXCMM60 Advanced Industrial Multimeter

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

METRA 22 26S/M Analog-Digital Multimeters with Signal Generator

Technical Datasheet. Delta Power 1000A / 400A AC-DC

RISH Multi 12S...18S Analog - Digital multimeters

METRA HIT 28C Calibrator, Multimeter and Milliohmmeter

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Operating Instructions METRA HIT 16I/L/T. Analog Digital Multimeter with Insulation Measurement /5.06

79/26 Series III Multimeter

Data sheet IDM 98III Digital Multimeter

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

METRAClip87 and 88 Clamp Multimeters

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

N24, N25 DIGITAL PANEL METER

METRA HIT 22 26S/M Analog-Digital Multimeters with Signal Generator

# Digital Multimeter

Fluke 83V and 87V Digital Multimeters

Digital-Multimeter UNIGOR 380, 390

Data sheet IDM 99III Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Digital-Multimeter UNIGOR 380, UNIGOR 390

Fluke 1587 FC/1577 Insulation Multimeters

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

METRAHit 30M Precision Digital Multimeter

METRA 28C Calibrator, Multimeter and Milliohmmeter

RISHABH 6012 / 6013 / 6015 / 6016

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

VariTrans P D1 TRMS

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

High precision measurement system for current and voltage IHC-A/B-RM01/03

E Series 9.00 (1/2) E series

METRAClip85 and 86 Clamp Multimeters

METRAHIT X-TRA PRO BASE TRMS Digital Multimeters

METRAHIT 28C Calibrator, Multimeter and Milliohmmeter

APPA 300 Series. The Most User-Friendly High Performance Multimeter

METRAHIT T-COM Cable Multimeter for Measurements in Symmetrical Copper Cable Networks

True RMS Bench Multimeter 5492B

Flexible AC current probes

Technical Data Sheet. x1000. kwh R Y B

Current Clamp. 210

DL-91 DL-92 DL-94 DL-97

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

AC/DC CLAMP METER CM4371, CM4373

Agilent 970-Series Handheld Multimeters Data Sheet

AMM-1022 Digital Multimeter USER`S MANUAL

ATK Clamp Meter

DVM1190 DIGITAL MULTIMETER

True RMS Bench Multimeters 2831E and 5491B

QUICK SETUP GUIDE SECULIFE HITAM

RS Pro ENGLISH. Datasheet

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

Current clamps for AC current

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Current clamps for AC current

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

RS Pro ENGLISH. Datasheet

METRATESTER 5+ Tester for DIN VDE /6.15

Take the current. Clamp meters available for diverse applications and conductor diameters.

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Simple measurement at the best price

Energy Management Energy Meter GM3D

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

5 years! Modular Housings. VariTrans P Warranty

True RMS Bench Multimeters 2831E and 5491B

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

IDM 503 & 505 Digital Multimeters

Table of Contents. Table of Contents Instrumentation Multimeter. Lucas Nülle GmbH Page 1/14

HP 972A and 973A Multimeter User s Guide

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

DIGITAL MULTIMETER INSTRUCTION MANUAL

Electrical measurement technology. Re-invented.

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Transcription:

Gamma 20 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts Digital Multimeters Clamp Meters GAMMA 20 DIGITAL MULTIMETER Gamma 20 multimeter is 5 3 /4 digital high performance precision instruments for laboratory use, as well as for service and training. With a display range of 300,000 digits, as well as outstanding accuracy and long-term stability, the fulfill all requirements for use. Features Convenient triple display High resolution and precision RMS value with distorted waveshape Overload protection Automatic blocking sockets (ABS) Insulation Testers SUBJECT TO CHANGE WITHOUT NOTICE This manual superseded all previous versions please keep for future reference

Application Gamma 20 multimeter is 5 3 /4 digit high performance precision instruments for laboratory use, as well as for service and training. With a display range of 300,000 digits, as well as outstanding accuracy and long-term stability, they fulfill all requirements for use. Product Features Convenient Triple Display High Resolution & Precision RMS Value with Distorted Waveshape Additional Functions Simultaneous measurement of voltage and frequency or voltage and min, max values is possible. Also current and frequency or the current measurement and minimum and maximum values are displayed simultaneously The usual switching back and forth between display values is no longer necessary. Main display resolution for AC is 4 ¾ places and for DC it is 5 ¾ places 5 ¾ places ( 309,999digits) for DC measured quantities and 4 ¾ places ( 30,999 digits) for AC measured quantities allow for precision reference measurements and use as a calibration standard for testing devices and assemblies. The utilized measuring method allows for waveshape independent RMS measurement (TRMS AC) Resistance (Ω), Temperature ( C ), Continuity, Diode, Capacitance, Frequency, Duty cycle Overload The instrument is safeguarded for up to 1000V Protection in all measuring functions by overload protection. An acoustic signal is generated if the upper voltage or current range limit is exceeded. FUSE appears at the display if the fuse for the current Measuring 1000V CAT III/600V CAT IV as per Category IEC Standard 61010-1. Automatic Automatic blocking sockets prevent incorrect Blocking connection of measurement cables and Sockets (ABS) inadvertent selection of the wrong measured quantity. This significantly reduces danger to the user, the instrument and the system under test, and in many cases eliminates it entirely. Backlit Display The instrument is provided with user selectable Back-lit for taking measurements in poor lighting conditions / dark areas. Technical Specifications Reference conditions for Accuracy Reference temperature 23 C ± 2K Relative Humidity 45%...55% RH Waveform of measured Sinusoidal quantity Input frequency 50 or 60 Hz ±2% Battery Voltage 8 V ± 0.1 V Safety Pollution degree 2 Installation category III IV Operating voltage 1000V 600V High Voltage Test 6.7 kv (IEC 61010-1-2001) Fuses For ranges up to 300 ma For the range 10A FF1.6A /1000V/6.3mm x 32 mm. Rating 20 KA with 1000 V~ and ohmic load. In conjunction with diodes protects all current measuring ranges up to 300 ma. 16 A /1000V /10 mm X 38 mm, protects 10 A range up to 1000 V. Applicable Regulations and Standards IEC 1010-1 /EN61010-1 Safety regulations for electrical measurement, Control, regulating and laboratory devices IEC 61326:2002 Class B Electrical equipment for control technology and laboratory use EMC requirements IEC 61000-4-2 8kV atmosphere discharge. 4kV contact discharge IEC 6100-4-3 3VT/m DIN EN 60259 Test equipment & test procedures DIN VDE 0470 part 1 -Degrees of protection provided by enclosures (IP Code). Applicable Standards EMC IEC 61326: Class B Immunity IEC 61000-4-2 8 KV atmosphere discharge, 4 KV contact discharge IEC 61000-4-3 : 3 V/m IP for water & dust IEC 60529 : IP 50 for Housing Issue 1.0 Gamma 20 1

Technical Specifications Battery Battery Voltage Battery type 9V flat cell battery Manganese Dioxide cell as per IEC 6 F22 or alkaline manganese cell according to IEC 6 LR61 suitable NiCd storage battery. Battery Life Minimum 300 hours on Vdc, Adc, 150 hours on Vac, Aac. Without Backlit Environmental Operating temperature -10 to +50 C Storage temperature -25 to +70 C Relative humidity <75% non condensing. Altitude Up to 2000 m Mechanical Configuration Protection type IP 50, for the connection sockets IP 20. Dimensions 84 mm X 195 mm X 35mm Weight 350 gm approx, including battery. Meas. Meas. Resolution at Meas. Input impedence Inherent deviation at highest Overload Capacity 4) function range Range Upper Limit resolution under reference Meas. condition function DC Accuracy AC Accuracy 9) Overload Overload 1 2 300000 1) 30000 1) DC AC ±(..% of rdg ± (..% of rdg + value duration +.. %rng + Digit)...Digit 3.0V 100 µv 100 µv 11 MΩ 5 MΩ // < 50pF 0.02+0.008+20 0.2+30 DC V 30.0V 1 mv 1 mv 10 MΩ 5 MΩ // < 50pF 0.02+0.008+20 0.2+30 AC Cont. V 300V 10mV 10 mv 10 MΩ 5 MΩ // < 50pF 0.02+0.008+ 20 0.2+30 RMS 1000V 100 mv 100 mv 10 MΩ 5 MΩ // < 50pF 0.02+0.008+20 0.2+30 Sine 300mV 10 µv 10 µv >20MΩ 5 MΩ // < 50pF 0.02+0.015+30 6) 0.5+30 1000V Voltage drop. approx. DC Accuracy AC Accuracy 9) for upperrange limit B ±(..% of rdg ± (..% of rdg + +.. %rng + Digit)...Digit 300µA 10nA 10nA 300mV 300mV 0.05+0.02+20 0.5+30 3 ma 100nA 100nA 300mV 300mV 0.02+0.01+20 0.5+30 A 30mA 1nA 1 µa 300mV 300mV 0.02+0.01+20 0.5+30 0.36A Cont. A 300mA 10 µa 10 µa 300mV 300mV 0.1+0.01+20 0.5+30 10A 1mA 1mA 400mV 400mV 0.2+0.05+30 0.5+30 10A5) 5 min Open-circuit voltage ±(..% of rdg +.. %rng + Digit) 300Ω 10mΩ 1.3V -- 0.05+0.015+20 6) 3.0 kω 100mΩ 0.5V -- 0.05+0.015+20 30 kω 1Ω 0.5V -- 0.05+0.015+20 Ω 300 kω 10Ω 0.5V -- 0.05+0.025+20 1000V Ω 3.0 MΩ 100Ω 0.5V -- 0.1+0.025+20 DC 30 MΩ 1kΩ 0.3V -- 1+0.25+20 AC 10 Sec 300 Ω 0.1 Ω max. 1.3V -- 1.2+0+10 RMS 2.0 V 100µV max. 2.5 V 0.2+0+10 Sine Discharge U0 max. ±(..% of rdg +... %rng) resistor 3.0 nf 1 pf 10 MΩ 3 V 2.5+0.2 6) 30 nf 10pF 10 MΩ 3 V 1.2+0.2 300nF 100pF 1 MΩ 3 V 1.2+0.2 1000V 3.0µF 1 nf 100 kω 3 V 1.2+0.2 DC F 30µF 10nF 11 kω 3 V 1.2+0.2 10 Sec AC F 300µF 100nF 2 kω 3 V 3.2+1 RMS 3000µF 1 µf 2 kω 3 V 3.2+1 Sine 30000µF 10 µf 2 kω 3 V 3.2+1 f min 3) ±(..% of rdg. + Digit ) 2 Gamma 20 Issue 1.0

Technical Specifications Meas. Meas. Resolution at Meas. Input impedence Inherent deviation at highest Overload Capacity 4) function range Range Upper Limit resolution under reference Meas. condition function 300.00Hz 0.01Hz 10 Hz 0.1+3 7) < 3 KHz 3.0000kHz 0.1Hz 100 Hz 0.1+3 7) 1000V 30.0000kHz 1Hz 100Hz 0.1+3 7) < 30 KHz Hz 300.000kH 10Hz 1kHz 0.05+10 7) 300V Cont. Hz < 100 Khz 30V 100 min 2) 10 ms ±20Digit 1000V ±(..% of rdg. + Digit ) -200.0 1Kelvin +3 8) +100.0 0C Pt100 +100.0 1000V C +850.0 1% + 3 8) DC 10 Sec C C 0.1 C AC -100.0 RMS Pt1000 +100.0 C 1 Kelvin + 3 8) Sine +100.0. 1% + 3 8) +850.0 C 1) Display : 5 ¾ places for DC, 4 ¾ places for AC 2) Stopwatch : Format : mm: ss : hh Where m = minute, s = second and h = hundredth second, max. : 99 : 59 : 59 3) Lowest measurable frequency with sinusoidal measurement signal symmetric to zero point. 4) at 0. 4 C 5) 12A 5min, 16A 30 s 6) With zero adjuster; Without zero adjuster. 7) Vac >1Veff/rms 8) Without sensor 9) Values less than 150 counts are suppressed. Response time (After manual range selection) Measured Quantity/Measured range Response time Transient response for step function of the measured quantity VDC,VAC,A AC+DC,A AC 1.5 s From 0 to 80 % of upper range limit. 30Ω 3 MΩ 2 s 30 MΩ 5 s From to 50 % of upper range limit. 1.5s ºC 3 s 3.0nF,300µF, Max. 1 3 s 3000 µf Max. 7 s From 0 to 50 % of upper range limit. 30000 µf Max. 14 s 300 Hz,3KHz Max 2 s 30 KHz,300 KHz Max 0.7 s Issue 1.0 Gamma 20 3

Influence Quantities & Influence Errors: Influence Quantity Range of Influence Measured Quantity / Variation 1) Measuring Range ± (...% of rdg. +...digits) VDC 0.05+3 V ~ 0.2+3 300µA 300mA DC 0.2+3 300µA 300mA AC 0.3+3-10 ºC 10 A AC,10 A DC 0.5+3 Temperature +21 ºC 300 Ω 2) 0.1+5 and 3 KΩ 3 MΩ 0.1+3 +25 ºC +40ºC 30 MΩ 0.6+3 30 nf 2) 30 µf 0.5+3 30 µf-30mf 2.0+3 Hz 0.1+3-200 +200 ºC 0.5 Kelvin+2 Digits +200 +850ºC 0.5+2 25 Hz...< 45 Hz 300 mv ~ 1.0+20 > 65 Hz... 200 Hz 1.0+20 25 Hz...< 45 Hz 1.0+20 > 65 Hz... 400 Hz 3 300V ~ 0.5+20 Frequency of the measured >400 Hz 1 <KHz 0.5+20 quantity >1 KHz 20 Khz 0.5+20 25 Hz...< 30 Hz 1.0+20 > 30 Hz... 45 Hz 1000V ~ 0.5+20 >65 Hz 1 <Khz 2.0+20 25Hz < 45 Hz 1.0+20 >65 Hz 1 khz A~ 1.0+20 Wave form of the measured 1.3 ± 1 % of rdg quantity3 ) Crest factor CF 3.5 V ~ 4), A~ 4) ± 3 % of rdg V DC ±15 Digit V~ ±30 Digit ADC ±20 Digit A AC ±40 Digit Battery Voltage 5) < 7.5 V 30Ω / 300 Ω/ C ±40 Digit > 8.1 V 10.0 V 3 kω 30MΩ ±40 Digit Cpacitance ±50 Digit Hz ±10 Digit 75% Relative humidity 3Days ±1 Digit Meter off DATA - ± 1 digits MIN/MAX - V ac/dc, A ac/dc ± 2 digits Influence Quantity Range of Influence Measuring Ranges Attenuation Noise quantity max. 1000 V V dc > 120 db Common Mode 300 mv~ 30V~ > 80 db interference Noise quantity max. 1000 V ~ 300 V~ > 70 db Voltage 50 Hz, 60 Hz sinusoidal 1000 V~ > 60 db Noise quantity V ~ Value of the measuring range at a time V dc > 50dB Normal Mode Max. 1000V~,50Hz, 60Hz interference Sinusoidal voltage Noise quantity max. 1000 V- V~ >110dB 4 Gamma 20 Issue 1.0

Ordering Information GM20-9NB4000000000 GM20-9FB4000000000 GAMMA 20 Gamma 20 TRMS Backlit Gamma 20 Fine Tip TRMS Backlit Contact Sifam Tinsley Instrumentation Ltd 1 Warner Drive Springwood Industrial Estate Braintree, Essex CM7 2YW Tel: 01376 335271 E-mail: sales@sifamtinsley.com www.sifamtinsley.co.uk Issue 1.0 Gamma 20 5