FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

Similar documents
FCC PART TEST REPORT. Weccan Industrial Limited

FCC PART 95 MEASUREMENT AND TEST REPORT HENAN ESHOW ELECTRONIC COMMERCE CO., LTD

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

TEST REPORT. For ELECTRONICS TECHNOLOGY (DONG GUAN) COMPANY LIMITED EN V9.0.2 ( )

FCC PART TEST REPORT. invoixa

FCC PART TEST REPORT. Hallmark Global LTD. dba HEXA.

FCC PART TEST REPORT BEYOND RADIO TECHNOLOGY LIMITED

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

EN 62479:2010 ASSESSMENT REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD

FCC PART TEST REPORT. ShenZhen Foscam Intelligent Technology Co.,Ltd

FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT. Chengdu Vantron Technology, Ltd.

ETSI EN V2.1.1 ( ) TEST REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD

FCC PART EMI MEASUREMENT AND TEST REPORT. Advanced Card Systems Ltd.

FCC PART EMI MEASUREMENT AND TEST REPORT. Advanced Card Systems Ltd.

FCC PART 15B TEST REPORT SZ DJI TECHNOLOGY CO., LTD

FCC Part 22H & 24E Measurement and Test Report

TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8)

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Spectrian Dual Mode Cellular Power Amplifier Model No.: SCLPA 800 CR FCC ID: I2ONTHX51AA

TRANSMITTER MODEL: KAS-2030M

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

FCC TEST REPORT. For. SPECTRA Technologies Holdings Co. Ltd EFTPOS. Model No. : SPECTRA T1000

For Sky. Phone LLC. FCC Part 22H. FCC Rules: 3G Smart Phone. Report No.: By: Tested By: Manager. Prepared. Shenzhen SEM.

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

FCC PART TEST REPORT. POSH Mobile Limited

EXHIBIT 10 TEST REPORT. FCC Parts 2 & 24

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

FCC & IC Certification. Test Report. FCC & Industry Canada Certification. Test Report. for Hetronic USA FCC ID: LW9-CS434TXN IC ID: 2219A-CS434TXN

FCC Part 90 Mobile UHF Repeater Test Report

FCC PART TEST REPORT. Zhejiang Flashforge 3D Technology CO., Ltd

FCC Part 90 Rules Test Report

FCC PART 15C IC RSS-210, ISSUE 7, JUNE 2007 TEST AND MEASUREMENT REPORT. SunPower Corporation

FCC Part 90 Certification Application. FCC Form 731. For The. Guardian UHF RADIO MODEM FCC ID: NP

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

FCC Part 90 Rules Test Report

MEASUREMENT PROCEDURE AND TEST EQUIPMENT USED

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

TRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503

Measurement Procedure & Test Equipment Used

FCC CERTIFICATION TEST REPORT

TRANSMITTER Model: TX24

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

HID GLOBAL CORPORATION

R. Grant, Wireless Group Manager

FCC PART 90 Test Report

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

MODEL: P5400 UHF-L Portable Radio

For. Tzone FCC ID: FCC Part Description: Product TZ-BT04. Report to Tested By: Manager STR I

FCC ID: A3LSLS-BD106Q. Report No.: HCT-RF-1801-FC003. Plot Data for Output Port 2_QPSK 9 khz ~ 150 khz Middle channel 150 khz ~ 30 MHz Low channel

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR50 August 29, 2012 First Approval Report

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR49 August 29, 2012 First Approval Report

TEST REPORT. Issued for: ShenZhen MYGT Co.,LTD D3 Tongfuyu Industrial Area Community of Shajing Town, Baoan, Shenzhen, China.

FCC RF Test Report. : FCC 47 CFR Part 2, and 90(S) : PCS Licensed Transmitter (PCB)

Vertex Standard Co., Ltd. Page 1 of 38

REPORT ON Radio testing of the VERTEX STANDARD VX-2100-G6-45 / VX-2200-G6-45 In accordance with ANSI/TIA/EIA-603, RSS-119. Report number TA000506

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

Version TEST REPORT NO. DATE DESCRIPTION

F2 Labs Peters Road Middlefield, Ohio United States of America

SHENZHEN TIMEWAY TESTING LABORATORIES. Test result: ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

TEST REPORT SZEM CR

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

Test report no. : Item tested : LCU Type of equipment : RFID Transceiver Module FCC ID : Y7V-LCU6333

EMC Test Report. Tested by: Jeremy O. Pickens, Senior EMC Engineer. Reviewed by: David Schramm, EMC/RF/SAR/HAC Manager

FCC RF Test Report. : FCC 47 CFR Part 2, and 90(S) : PCS Licensed Transmitter Held to Ear (PCE)

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies

HID GLOBAL CORPORATION

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

TIMCO ENGINEERING INC.

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

Radiated Emissions, FCC Part 15

FCC PART 80 & 90 TEST REPORT

FCC PART 15, SUBPART C TEST AND MEASUREMENT REPORT. CentraLite Systems Inc.

SPORTON FCCC RF APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID STANDARDD ZTE : N9518. The product was. received on. not be.

ADDENDUM TO ITRON, INC. TEST REPORT FC FOR THE AUTOMATED METER READING SYSTEM, FC 200 FCC PART 101 PARTIAL TESTING DATE OF ISSUE: MAY 22, 2007

TABLE OF CONTENTS SECTION TITLE PAGE. 5. LIST OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 EUT and Accessory List EMI Test Equipment

TEST REPORT. Report No.: HK (R1) Spin Master Toys Far East Ltd. Application For Certification (Original Grant) (FCC ID: PQN44438TX2G4)

FCC PART & IC RSS GHz FHSS TEST REPORT

6.5 Spurious Emissions at Antenna Terminals

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC PART 90 AND IC RSS-119, RSS-GEN TEST REPORT

TEST REPORT NO. DATE DESCRIPTION

TEST REPORT. Issued for:

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. ION Audio, LLC. Portable Karaoke PA speaker with vocal effects

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC PART 15 SUBPART C TEST REPORT FCC PART

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

TEST REPORT. Issued for: Marvelmind Robotics Lugovaya str., 4 bld 5 room 17, Skolkovo Innovation Center, Moscow, , Russian Federation

ROKU REMOTE MODEL: RC07

UMTS-FDD Band Ⅱ (Part 24E)

RF test report AU01+W02

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

Transcription:

FCC PART 95 MEASUREMENT AND TEST REPORT For Powerwerx, Inc. 23695 Via Del Rio Yorba Linda California 92887, United States FCC ID: 2ACK8TR505D Report Type: Original Report Product Type: Two-way radio Test Engineer: Report Number: Rocky Kang RSZ150914551-00A Report Date: 2015-10-30 Jimmy Xiao Reviewed By: Test Laboratory: RF Engineer Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.

TABLE OF CONTENTS GENERAL INFORMATION... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 OBJECTIVE... 3 RELATED SUBMITTAL(S)/GRANT(S)... 3 TEST METHODOLOGY... 3 TEST FACILITY... 3 SYSTEM TEST CONFIGURATION... 4 DESCRIPTION OF TEST CONFIGURATION... 4 EQUIPMENT MODIFICATIONS... 4 SUPPORT EQUIPMENT LIST AND DETAILS... 4 BLOCK DIAGRAM OF TEST SETUP... 4 SUMMARY OF TEST RESULTS... 5 FCC 1.1307(b) & 2.1093 - RF EXPOSURE... 6 APPLICABLE STANDARD... 6 FCC 2.1046, 95.639(h) - RF OUTPUT POWER... 7 APPLICABLE STANDARD... 7 TEST PROCEDURE... 7 TEST EQUIPMENT LIST AND DETAILS... 7 TEST DATA... 8 FCC 2.1047 & 95.637(a) - MODULATION CHARACTERISTIC... 10 APPLICABLE STANDARD... 10 TEST EQUIPMENT LIST AND DETAILS... 10 TEST PROCEDURE... 10 TEST DATA... 10 FCC 2.1049 & 95.633(f) & 95.635(e)- AUTHOURIZED BANDWIDTH AND EMISSION MASK... 17 APPLICABLE STANDARD... 17 TEST PROCEDURE... 18 TEST EQUIPMENT LIST AND DETAILS... 18 TEST DATA... 18 FCC 2.1053 & 95.635(e) - RADIATED SPURIOUS EMISSION... 21 APPLICABLE STANDARD... 21 TEST PROCEDURE... 21 TEST EQUIPMENT LIST AND DETAILS... 21 TEST DATA... 22 FCC 2.1055 (d), 95.632(c) - FREQUENCY STABILITY... 23 APPLICABLE STANDARD... 23 TEST PROCEDURE... 23 TEST EQUIPMENT LIST AND DETAILS... 23 TEST DATA... 24 FCC Part 95 Page 2 of 24

GENERAL INFORMATION Product Description for Equipment Under Test (EUT) The Powerwerx, Inc. s product, model number: TR-505 (FCC ID: 2ACK8TR505D) or the "EUT" in this report was a Two-way radio, which was measured approximately: 12.5 cm (L) x 5.8cm (W) x 4.5 cm (H), rated input voltage: DC 7.4 V battery. * All measurement and test data in this report was gathered from production sample serial number: 1507083 (Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2015-09-14. Objective This report is prepared on behalf of Powerwerx, Inc.in accordance with Part 2 and Part 95, Subpart A & Subpart B & Subpart E of the Federal Communication Commissions rules. Related Submittal(s)/Grant(s) FCC Part 95 FRF submission with FCC ID: 2ACK8TR505D. Test Methodology All tests and measurements indicated in this document were performed in accordance with Part 95 Subpart A, B and Subpart E of the Federal Communication Commissions rules with TIA-603-D, Land Mobile FM or PM-Communications Equipment-Measurement and Performance Standards. All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Shenzhen). The radiated testing was performed at an antenna-to-eut distance of 3 meters. Test Facility The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located on the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China. Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports submitted to the Federal Communication Commission (FCC). The details of these reports have been found to be in compliance with the requirements of Section 2.948 of the FCC Rules on October 31, 2013. The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.10-2013. The Federal Communications Commission has the reports on file and is listed under FCC Registration No.: 382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access Link (PAL) database. FCC Part 95 Page 3 of 24

SYSTEM TEST CONFIGURATION Description of Test Configuration The system was configured for testing in a typical fashion (as normally used by a typical user). Equipment Modifications No modification was made to the EUT tested. Support Equipment List and Details Manufacturer Description Model Serial Number N/A 50 ohm Load N/A N/A Block Diagram of Test Setup 50 ohm Load EUT 1.0 Meter Non-conductive Table 150 cm above Ground Plane 1.5 Meter FCC Part 95 Page 4 of 24

SUMMARY OF TEST RESULTS FCC Rules Description of Test Results 1.1307(b); 2.1093 RF Exposure Compliance 2.1046, 95.639(h) RF Output Power Compliance 2.1047, 95.637(a) Modulation Characteristic Compliance 2.1049, 95.633(f), 95.635(e) Authorized Bandwidth & Emission Mask Compliance 2.1053, 95.635(e) Spurious Radiated Emissions Compliance 2.1055(d), 95.632(c) Frequency Stability Compliance Note: This report ONLY for MURS function FCC Part 95 Page 5 of 24

FCC 1.1307(b) & 2.1093 - RF EXPOSURE Applicable Standard According to FCC 1.1307(b) and 2.1093, protable device operates Part 90 should be subjected to rountine environmental evaluation for RF exposure prior or equipment authorization or use. Result: Compliance. Please refer to SAR Report Number: RSZ150914554-20A FCC Part 95 Page 6 of 24

FCC 2.1046, 95.639(h) - RF OUTPUT POWER Applicable Standard Per FCC 95.639 (h) No MURS unit, under any condition of modulation, shall exceed 2 Watts transmitter power output. Test Procedure Conducted RF Output Power: The RF output of the transmitter was connected to the input of the spectrum analyzer through sufficient attenuation. Spectrum Analyzer Setting: R B/W Video B/W 100 khz 300 khz Test Equipment List and Details Manufacturer Description Model NO. Serial NO. Calibration Date Calibration Due Date HP Signal Generator 8648C 3426A01345 2015-06-09 2016-06-09 HP Amplifier 8447E 1937A01046 2015-05-06 2016-05-06 Rohde & Schwarz EMI Test Receiver ESCI 101122 2014-11-03 2015-11-03 Sunol Sciences Bi-log Antenna JB1 A040904-2 2014-12-07 2017-12-06 Com Power Dipole Antenna AD-100 041000 2015-08-18 2016-08-18 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have been performed in accordance to requirements that traceable to National Primary Standards and International System of Units (SI). FCC Part 95 Page 7 of 24

Test Data Environmental Conditions Temperature: 24 C Relative Humidity: 50 % ATM Pressure: 100.0 kpa The testing was performed by Rocky Kang on 2015-10-10. Test Mode: Transmitting Frequency (MHz) Output Power Output Power Limit (dbm) (W) (W) Result 151.88 32.27 1.69 2 Pass 154.60 32.29 1.69 2 Pass Note:The rated power is 2W. FCC Part 95 Page 8 of 24

151.88 MHz Marker 1 [T1] Ref Lvl 32.27 dbm 45 dbm 151.86897796 MHz 45 30 db Offset 40 1 30 RBW 100 khz RF Att 30 db VBW 300 khz SWT 5 ms Unit dbm 1 [T1] 32.27 dbm 151.86897796 MHz A 20 1MAX 10 1MA 0-10 -20-30 -40-50 -55 Center 151.88 MHz Date: 10.OCT.2015 09:57:46 100 khz/ Span 1 MHz 154.60 MHz Marker 1 [T1] Ref Lvl 32.29 dbm 45 dbm 154.58496994 MHz 45 30 db Offset 40 1 30 RBW 100 khz RF Att 30 db VBW 300 khz SWT 5 ms Unit dbm 1 [T1] 32.29 dbm 154.58496994 MHz A 20 1MAX 10 1MA 0-10 -20-30 -40-50 -55 Center 154.6 MHz Date: 10.OCT.2015 10:04:52 100 khz/ Span 1 MHz FCC Part 95 Page 9 of 24

FCC 2.1047 & 95.637(a) - MODULATION CHARACTERISTIC Applicable Standard Per FCC 2.1047 and 95.637(a): A GMRS transmitter that transmits emission type F3E must not exceed a peak frequency deviation of plus or minus 5 khz. A FRS unit that transmits emission type F3E must not exceed a peak frequency deviation of plus or minus 2.5 khz, and the audio frequency response must not exceed 3.125 khz. Each GMRS transmitter, except a mobile station transmitter with a power output of 2.5 W or less, must automatically prevent a greater than normal audio level from causing over-modulation. The transmitter also must include audio frequency low pass filtering, unless it complies with the applicable paragraphs of 95.631 (without filtering.) The filter must be between the modulation limiter and the modulated stage of the transmitter. At any frequency (f in khz) between 3 and 20 khz, the filter must have an attenuation of at least 60 log 10 (f/3) db greater than the attenuation at 1 khz. Above 20 khz, it must have an attenuation of at least 50 db greater than the attenuation at 1 khz. Test Equipment List and Details Manufacturer Description Model No. Serial No. Calibration Date Calibration Due Date HP RF Communication Test Set HP8920A 3438A05201 2015-06-13 2016-06-13 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have been performed in accordance to requirements that traceable to National Primary Standards and International System of Units (SI). Test Procedure Test Method: TIA/EIA-603-D Test Data Environmental Conditions Temperature: 24 C Relative Humidity: 50 % ATM Pressure: 100.0 kpa The testing was performed by Rocky Kang on 2015-10-10. Please refer to the following tables and plots. FCC Part 95 Page 10 of 24

Test Mode: Transmitting MODULATION LIMITING Channel: 151.88 MHz Audio Input Level (db) Frequency Deviation (khz) (@ 300 Hz ) (@ 1000 Hz ) (@ 3000 Hz ) FCC Limit (khz) 20.0 0.503 2.424 2.188 5.0 15.0 0.354 2.281 2.177 5.0 10.0 0.310 2.215 2.167 5.0 5.0 0.265 1.955 2.156 5.0 0.0 0.201 1.500 2.133 5.0-5.0 0.132 0.878 1.927 5.0-10.0 0.099 0.515 1.185 5.0-15.0 0.082 0.319 0.682 5.0-20.0 0.073 0.208 0.402 5.0 FCC Part 95 Page 11 of 24

Audio frequency Low Pass Filter Response Channel: 151.88 MHz Audio Frequency (khz) Response Attenuation (db) FCC Limit (db) 2.5-4.65 0.0 3.0-5.54 0.0 3.5-9.53-4.0 4.0-11.26-7.5 5.0-16.79-13.3 7.0-27.45-22.1 10.0-35.21-31.4 15.0-48.34-42.0 20.0-52.64-50.0 30.0-52.12-50.0 50.0-52.96-50.0 70.0-55.66-50.0 FCC Part 95 Page 12 of 24

Analog Signal within the Audio Bandwidth Response Channel: 151.88 MHz Modulation Frequency (khz) Maximum Deviation (khz) Limit (khz) 100 0.341 5.000 200.0 0.514 5.000 300.0 0.891 5.000 400.0 0.893 5.000 500.0 0.895 5.000 600.0 1.339 5.000 700.0 1.146 5.000 800.0 1.851 5.000 900.0 2.141 5.000 1000.0 2.289 5.000 1500.0 2.263 5.000 2000.0 2.432 5.000 FCC Part 95 Page 13 of 24

MODULATION LIMITING Channel: 154.60 MHz Audio Input Level (db) Frequency Deviation (khz) (@ 300 Hz ) (@ 1000 Hz ) (@ 3000 Hz ) FCC Limit (khz) 20.0 0.635 4.408 4.197 5.0 15.0 0.553 4.328 4.143 5.0 10.0 0.516 4.172 4.165 5.0 5.0 0.326 2.773 4.019 5.0 0.0 0.193 1.500 3.482 5.0-5.0 0.135 0.893 2.083 5.0-10.0 0.102 0.518 1.184 5.0-15.0 0.083 0.321 0.695 5.0-20.0 0.072 0.209 0.417 5.0 FCC Part 95 Page 14 of 24

Audio frequency Low Pass Filter Response Channel: 154.60 MHz Audio Frequency (khz) Response Attenuation (db) FCC Limit (db) 2.5-4.83 0.0 3.0-5.94 0.0 3.5-8.79-4.0 4.0-11.34-7.5 5.0-16.48-13.3 7.0-26.58-22.1 10.0-35.28-31.4 15.0-48.47-42.0 20.0-52.34-50.0 30.0-52.84-50.0 50.0-51.31-50.0 70.0-52.14-50.0 FCC Part 95 Page 15 of 24

Analog Signal within the Audio Bandwidth Response Channel: 154.60 MHz Modulation Frequency (khz) Maximum Deviation (khz) Limit (khz) 100.0 0.085 5.000 200.0 0.215 5.000 300.0 0.604 5.000 400.0 1.567 5.000 500.0 1.756 5.000 600.0 2.634 5.000 700.0 2.256 5.000 800.0 3.616 5.000 900.0 4.163 5.000 1000.0 4.426 5.000 1500.0 4.568 5.000 2000.0 4.516 5.000 FCC Part 95 Page 16 of 24

FCC 2.1049 & 95.633(f) & 95.635(e)- AUTHOURIZED BANDWIDTH AND EMISSION MASK Applicable Standard According to 95.633(f), the authorized bandwidth for any emission type transmitted by a MURS transmitter is specified as follows: (1) Emissions on frequencies 151.820 MHz, 151.880 MHz, and 151.940 MHz are limited to 11.25 khz. (2) Emissions on frequencies 154.570 and 154.600 MHz are limited to 20.0 khz. (3) Provided, however, that all A3E emissions are limited to 8 khz. According to 95.635(e), for transmitters designed to operate in the MURS, transmitters shall comply with the following: (1) Emission Mask 1 For transmitters designed to operate with a 12.5 khz channel bandwidth, any emission must be attenuated below the power (P) of the highest emission contained within the authorized bandwidth as follows: (i) On any frequency from the center of the authorized bandwidth f o to 5.625 khz removed from f o : Zero db. (ii) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (f d in khz) of more than 5.625 khz but no more than 12.5 khz: at least 7.27(f d 2.88 khz) db. (iii) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (f d in khz) of more than 12.5 khz: at least 50 + 10 log (P) db or 70 db, whichever is the lesser attenuation. (2) Emission Mask 2 For transmitters designed to operate with a 25 khz channel bandwidth that are equipped with an audio low-pass filter, the power of any emission must be below the unmodulated carrier power (P) as follows: (i) On any frequency removed from the assigned frequency by more than 50 percent, but not more than 100 percent of the authorized bandwidth: at least 25 db. (ii) On any frequency removed from the assigned frequency by more than 100 percent, but not more than 250 percent of the authorized bandwidth: at least 35 db. (iii) On any frequency removed from the assigned frequency by more than 250 percent of the authorized bandwidth: at least 43 + 10 log (P) db. FCC Part 95 Page 17 of 24

(3) Emission Mask 3 For transmitters designed to operate with a 25 khz channel bandwidth that are not equipped with an audio low-pass filter, the power of any emission must be attenuated below the unmodulated carrier output power (P) as follows: (i) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (f d in khz) of more than 5 khz, but not more than 10 khz: at least 83 log (f d /5) db. (ii) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (f d in khz) of more than 10 khz, but not more than 250 percent of the authorized bandwidth: at least 29 log (f d 2 /11) db or 50 db, whichever is the lesser attenuation. (iii) On any frequency removed from the center of the authorized bandwidth by more than 250 percent of the authorized bandwidth: at least 43 + 10 log (P) db. Test Procedure TIA-603-D, section 2.2.11 Test Equipment List and Details Manufacturer Description Model Serial Number HP RF Communication Test Set Calibration Date Calibration Due Date HP8920A 3438A05201 2015-06-13 2016-06-13 Rohde & Schwarz Signal Analyzer FSIQ26 8386001028 2015-12-11 2015-12-11 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have been performed in accordance to requirements that traceable to National Primary Standards and International System of Units (SI). Test Data Environmental Conditions Temperature: 24 Relative Humidity: 52 % ATM Pressure: 101.0 kpa The testing was performed by Rocky Kang on 2015-10-10. Test Mode: Transmitting Frequency (MHz) 20dB Bandwidth (khz) Limit (khz) Result 151.88 10.46 11.25 Pass 154.60 15.75 20.00 Pass FCC Part 95 Page 18 of 24

99% Occupied Bandwidth & 20 db Emissions Bandwidth: 151.88 MHz Delta 1 [T1] Ref Lvl -0.99 db 40 dbm 10.46092184 khz 40 30 db Offset 30 D1 29.49 dbm 20 T1 1 10 D2 9.49 dbm 1MAX RBW 300 Hz RF Att 30 db VBW 1 khz SWT 3.4 s Unit dbm 1 [T1] 9.27 dbm A 151.87488978 MHz 1 [T1] -0.99 db 10.46092184 khz OPB 10.10020040 khz T1 [T1] 12.07 dbm T2 151.87501002 MHz 1 T2 [T1] 12.19 dbm 1MA 151.88511022 MHz 0-10 -20-30 -40-50 -60 Center 151.88 MHz Date: 10.OCT.2015 15:50:02 6 khz/ Span 60 khz 154.60 MHz Delta 1 [T1] Ref Lvl -2.69 db 40 dbm 15.75150301 khz 40 30 db Offset 30 D1 26.88 dbm 20 T1 10 1MAX D2 6.88 dbm 1 0 RBW 300 Hz RF Att 30 db VBW 1 khz SWT 3.4 s Unit dbm 1 [T1] 2.11 dbm A 154.59224449 MHz 1 [T1] -2.69 db 15.75150301 khz OPB 15.27054108 khz T2 T1 [T1] 12.72 dbm 154.59248497 MHz T2 [T1] 12.16 dbm 1MA 154.60775551 MHz 1-10 -20-30 -40-50 -60 Center 154.6 MHz Date: 10.OCT.2015 15:51:40 6 khz/ Span 60 khz FCC Part 95 Page 19 of 24

Emission Mask: 151.88 MHz Ref Lvl 40 dbm 40 30 db Offset RBW 300 Hz VBW 1 khz SWT 11.5 s RF Att 40 db Unit dbm A 30 20 10 1MAX 1MA 0-10 -20 95-VL -30-40 -50-60 Center 151.88 MHz 20 khz/ Span 200 khz Date: 10.OCT.2015 11:50:01 154.60 MHz Ref Lvl 40 dbm 40 30 db Offset RBW 300 Hz VBW 1 khz SWT 11.5 s RF Att 40 db Unit dbm A 30 20 10 1MAX 1MA 0-10 95-VL20-20 -30-40 -50-60 Center 154.6 MHz 20 khz/ Span 200 khz Date: 10.OCT.2015 11:54:28 FCC Part 95 Page 20 of 24

FCC 2.1053 & 95.635(e) - RADIATED SPURIOUS EMISSION Applicable Standard FCC 2.1053 and 95.635 Test Procedure The transmitter was placed on a wooden turntable, and it was transmitting into a non-radiating load, which was also placed on the turntable. The measurement antenna was placed at a distance of 3 meters from the EUT. During the tests, the antenna height and polarization as well as EUT azimuth were varied in order to identify the maximum level of emissions from the EUT.The test was performed by placing the EUT on 3-orthogonal axis. The frequency range up to tenth harmonic of the fundamental frequency was investigated. Remove the EUT and replace it with substitution antenna. A signal generator was connected to the substitution antenna by a non-radiating cable. The absolute levels of the spurious emissions were measured by the substitution. Spurious emissions in db =10 1g (TXpwr in Watts/0.001)-the absolute level For 151.820 MHz, 151.880 MHz and 151.940 MHz: Spurious attenuation limit in db = 50+10 Log 10 (power out in Watts) For 154.570 MHz and 154.600 MHz: Spurious attenuation limit in db = 43+10 Log 10 (power out in Watts) Test Equipment List and Details Manufacturer Description Model Serial Number Calibration Date Calibration Due Date HP Amplifier 8447E 1937A01046 2015-05-06 2016-05-05 Rohde & Schwarz EMI Test Receiver ESCI 101120 2014-11-03 2015-11-03 Sunol Sciences Bi-log Antenna JB1 A040904-2 2014-12-07 2017-12-06 Mini Amplifier ZVA-183-S+ 5969001149 2015-04-23 2016-04-22 Rohde & Schwarz Signal Analyzer FSIQ26 8386001028 2014-12-11 2015-12-11 A.H. System Horn Antenna SAS-200/571 135 2015-02-10 2016-02-10 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have been performed in accordance to requirements that traceable to National Primary Standards and International System of Units (SI). FCC Part 95 Page 21 of 24

Test Data Environmental Conditions Temperature: 24 Relative Humidity: 52 % ATM Pressure: 101.0 kpa The testing was performed by Rocky Kang on 2015-10-10. Test Mode: Transmitting Channel: 151.88MHz Frequency (MHz) Indicated Receiver Reading (dbuv) Table Angle Degree Test Antenna Height (m) Polar (H/V) Level (dbm) Substituted Antenna Gain Cable Loss (db) Absolute Level (dbm) Limit (dbm) Margin (db) 303.76 45.78 8 1.0 H -49.2 0 0.36-49.56-20 29.56 303.76 50.95 291 2.2 V -44.1 0 0.36-44.46-20 24.46 455.64 36.78 150 2.2 H -60.2 0 0.47-60.67-20 40.67 455.64 48.96 267 1.5 V -48.0 0 0.47-48.47-20 28.47 607.52 46.65 43 1.2 H -50.4 0 0.57-50.97-20 30.97 607.52 56.89 205 1.1 V -40.1 0 0.57-40.67-20 20.67 1063.16 43.31 181 1.2 H -53.6 6.10 1.50-49.00-20 29.00 1063.16 44.75 359 2.3 V -53.6 6.10 1.50-49.00-20 29.00 Channel: 154.60 MHz Frequency (MHz) Indicated Receiver Reading (dbuv) Table Angle Degree Test Antenna Height (m) Polar (H/V) Level (dbm) Substituted Antenna Gain Cable Loss (db) Absolute Level (dbm) Limit (dbm) Margin (db) 309.20 45.47 154 1.4 H -49.5 0 0.36-49.86-13 36.86 309.20 46.71 268 1.2 V -48.3 0 0.36-48.66-13 35.66 463.80 45.38 92 1.1 H -51.6 0 0.47-52.07-13 39.07 463.80 58.91 161 2.3 V -38.1 0 0.47-38.57-13 25.57 618.40 64.18 147 2.0 H -32.8 0 0.57-33.37-13 20.37 618.40 72.35 55 1.9 V -24.7 0 0.57-25.27-13 12.27 1082.20 45.12 278 1.4 H -51.8 6.10 1.50-47.20-13 34.20 1082.20 46.79 126 2.5 V -51.5 6.10 1.50-46.90-13 33.90 FCC Part 95 Page 22 of 24

FCC 2.1055 (d), 95.632(c) - FREQUENCY STABILITY Applicable Standard According to FCC 2.1055(a) (1), the frequency stability shall be measured with variation of ambient temperature from 30 ºC to +50 ºC, and according to FCC 2.1055(d) (2), the frequency stability shall be measured with reducing primary supply voltage to the battery operating end point which is specified by the manufacturer. According to FCC 95.632(c), MURS transmitters must maintain a frequency stability of 5.0 ppm, or 2.0 ppm if designed to operate with a 6.25 khz bandwidth. Test Procedure Frequency Stability vs. Temperature: The equipment under test was connected to an external DC power supply and the RF output was connected to a Frequency Counter via feed-through attenuators. The EUT was placed inside the temperature chamber. The DC leads and RF output cable exited the chamber through an opening made for the purpose. After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the Frequency Counter. Frequency Stability vs. Voltage: 1) Vary primary supply voltage from 85 to 115 percent of the nominal value for other than hand carried battery equipment. (2) For hand carried, battery powered equipment, reduce primary supply voltage to the battery operating end point which shall be specified by the manufacturer. The output frequency was recorded for each voltage. Test Equipment List and Details Manufacturer Description Model NO. Serial NO. Calibration Date Calibration Due Date Hewlett-Packard Frequency Counter 5343A 2232A00827 2013-05-09 2016-05-08 WUHUAN Temperature & Humidity Chamber HTP205 20021115 NCR NCR * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have been performed in accordance to requirements that traceable to National Primary Standards and International System of Units (SI). FCC Part 95 Page 23 of 24

Test Data Environmental Conditions Temperature: 24 Relative Humidity: 52% ATM Pressure: 101.0 kpa The testing was performed by Rocky Kang on 2015-10-10. Test Mode: Transmitting MURS Environment Temperature ( ) Reference Frequency: 151.88 MHz, Limit: ±5 ppm Measurement Power Supplied Frequency (V DC ) (MHz) Frequency Error (ppm) Frequency Stability Ver. Temperature 50 7.4 151.880037 0.244 40 7.4 151.880031 0.204 30 7.4 151.880039 0.257 20 7.4 151.880035 0.230 10 7.4 151.880036 0.237 0 7.4 151.880039 0.257-10 7.4 151.880030 0.198-20 7.4 151.880034 0.224-25 7.4 151.880032 0.211 Frequency Stability Ver. Input Voltage 20 6.4 151.880031 0.204 Environment Temperature ( ) MURS Reference Frequency: 154.60 MHz, Limit: ±5 ppm Measurement Power Supplied Frequency (V DC ) (MHz) Frequency Error (ppm) Frequency Stability Ver. Temperature 50 7.4 154.600039 0.252 40 7.4 154.600034 0.220 30 7.4 154.600032 0.207 20 7.4 154.600036 0.233 10 7.4 154.600033 0.213 0 7.4 154.600032 0.207-10 7.4 154.600035 0.226-20 7.4 154.600037 0.239-25 7.4 154.600034 0.220 Frequency Stability Ver. Input Voltage 20 6.4 154.600037 0.239 ***** END OF REPORT ***** FCC Part 95 Page 24 of 24