HoloMonitor. Phase. For competent and powerful discoveries. Holographic time-lapse imaging cytometry

Similar documents
HoloMonitor M4. For powerful discoveries in your incubator

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging

Dynamic Phase-Shifting Microscopy Tracks Living Cells

1. Editorial. N 9 June Content

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

IncuCyte ZOOM Scratch Wound Processing Overview

IncuCyte ZOOM Scratch Wound Processing Overview

Introduction. INSTRUCTION MANUAL CAT XL, 6500-XLCORE, 6500-FL Evos-XL, Evos-XL/Core, Evos-FL

Practical work no. 3: Confocal Live Cell Microscopy

Working Simultaneously. The Next Level of TIRF Microscopy. cell^tirf Illuminator Motorized Total Internal Reflection Fluorescence

Imaging Photometer and Colorimeter

LSM 780 Confocal Microscope Standard Operation Protocol


High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

Confocal Laser Scanning Microscopy

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

IN Cell Analyzer 2000

Fast Laser Raman Microscope RAMAN

Technical Benefits of the

Parallel Digital Holography Three-Dimensional Image Measurement Technique for Moving Cells

ImageXpress Micro XLS Widefield High Content Screening System. Imaging with a vision.

Locating Molecules Using GSD Technology Project Folders: Organization of Experiment Files...1

Fast Laser Raman Microscope RAMAN

IncuCyte ZOOM Fluorescent Processing Overview

Using Autofocus in NIS-Elements

Cellular Bioengineering Boot Camp. Image Analysis

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy

Colony Imaging with powerful Analysis Software

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

μscope Microscopy Software

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

The Next Level of TIRF Microscopy. cell^tirf Illuminator Motorized Total Internal Reflection Fluorescence

Quality Performance, Innovative Design

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

OPTIV CLASSIC 321 GL TECHNICAL DATA

AxioCam MRc 5 A World of Digital Possibilities

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

the image analysis people

Prime Scientific CMOS Camera Processing Tools for Super-Resolution Microscopy

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

capabilities today. Flexibility for tomorrow.

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

#P Quality Measures for Imaging-based Cellular Assays

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Studying of Reflected Light Optical Laser Microscope Images Using Image Processing Algorithm

WHITE PAPER FAST PROTEIN INTERACTION BINDING CURVES WITH INO S F-HS CONFOCAL MICROSCOPE

Megapixel FLIM with bh TCSPC Modules

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

Image Analysis for Fluorescence

In our previous lecture, we understood the vital parameters to be taken into consideration before data acquisition and scanning.

Ionscope SICM. About Ionscope. Scanning Ion Conductance Microscopy. Ionscope A brand of Openiolabs Limited

Light Microscopy. Upon completion of this lecture, the student should be able to:

High Resolution BSI Scientific CMOS

Chapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation

Development of a High-speed Super-resolution Confocal Scanner

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

Cytell Cell Imaging System

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

Multi-channel imaging cytometry with a single detector

Multifluorescence The Crosstalk Problem and Its Solution

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP

Nanosurf easyscan 2 FlexAFM

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

Zeiss 880 Training Notes Zen 2.3

Sensor Fusion Enables Comprehensive Analysis of Laser Processing in Additive Manufacturing

Exercise questions for Machine vision

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

LVEM 25. Low Voltage Electron Microscope Fast Compact Powerful.... your way to electron microscopy

The First True Color Confocal Scanner

Manual. Cell Border Tracker. Jochen Seebach Institut für Anatomie und Vaskuläre Biologie, WWU Münster

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Zeiss 780 Training Notes

Stereotopix Research. Precision Pathology. Highthroughput. pathology. powered by newcast. Advantages of Stereotopix : RUO

T H E J O U R N A L O F C E L L B I O L O G Y

Diskovery Spinning Disk Guide

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

Infra Red Interferometers

Introduction Approach Work Performed and Results

Product Information Version 1.1. ZEISS Xradia 410 Versa Submicron X-ray Imaging: Bridge the Gap in Lab-based Microscopy

In this talk I will be talking about improving the accuracy of S phase estimation from cytometric data containing DNA content. A new method of interpo

A Rapid Image Acquisition Method for Focus Stacking in Microscopy

Nikon Instruments Europe

DU-897 (back illuminated)

Automated Imaging Technology to Simplify Your Workflow!

Bringing Answers to the Surface

Opterra. Multipoint Scanning Confocal Microscope. Innovation with Integrity. Cell-Friendly, High-Speed, High-Resolution Imaging

The First True Color Confocal Scanner on the Market

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Microvasculature on a chip: study of the Endothelial Surface Layer and the flow structure of Red Blood Cells

LSM 710 Confocal Microscope Standard Operation Protocol

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

The First True-Color Wide-Field Confocal Scanner

Microscopy from Carl Zeiss

Transcription:

HoloMonitor M4 Holographic time-lapse imaging cytometry For competent and powerful discoveries Monitor and quantify living cells in their natural environment with unrivaled temporal resolution Phase Holographic Imaging

Autoimmune diseases Cancer research Stem cell biology Inflammation Gene therapy Toxicological studies Regenerative medicine Applications Unprecedented time-lapse imaging minute by minute and day after day COMPREHENSIVE CELL CULTURE QCA Instantaneously assess your tissue culture integrity Growth rate data for untreated L929 mouse fibroblasts. XY spacial movement plots of murine macrophages M1 phenotype and M2 phenotype. Changes in optical volume over time based on tracking of one cell of interest. Quantitative tissue culture QC metrics within seconds. Cellular growth rate and morphological changes simultaneously. Cellular population statistics comprise many relevant cell-by-cell measurements (size, optical cell volume, thickness, irregularity, etc). CELL MOTILITY Monitor cell movement and morphological changes simultaneously Robust segmentation and tracking of cells of interest. Cell motility speed and cell migration velocity measurements at your fingertips. Non-invasive nature allows subsequent cellular staining for further analysis upon conclusion of holographic imaging. CELL CYCLE KINETICS Analyze cells through rounds of replication with full confidence No perturbation to the natural cell state and function with label-free analysis. Robust measurement of mitosis and cytokinesis based on reliable automated segmentation. Cytometric data with effortless relationship between images and quantitative data. Results comparable to classic cytometric DNA cell cycle studies using fluorescent DNA stains. CELL DEATH Advanced studies with real-time observation of critical events Etoposide-treated DU145 cell line: changes in optical thickness and volume during the death process in one individual cell. Continuous 2D and 3D visual observation of cellular death in second intervals. Large portfolio of quantitative morphological parameters: optical cell volume, thickness, area, irregularity, eccentricity and many more. Single cell tracking and population data analysis. Ideal suitability for studying drug-induced cell death. RARE OR TRANSIENT CELLULAR EVENTS Visualize previously unseen and analyze formerly undetected Unsurpassed temporal resolution with speed of image acquisition of up to 1 image per second. Morphological and quantitative tracking of cells of interest over multiple days. Cell-by-cell population data analysis. L929 mouse fibroblasts: a rare giant budding multinuclear cell.

HoloMonitor M4 Holographic time-lapse imaging cytometry Quantitative Label-free Long-term Diode laser Reference beam Sample beam Objective Image sensor Hologram HOLOGRAPHIC MICROSCOPY HoloMonitor M4 utilizes the principle of holographic microscopy. A low-power laser beam is split into two, one illuminating the sample and the other providing a reference beam. Laser light passing through the sample is affected by intra-cellular structures causing a phase shift of the illuminating light. Once combined, the two beams create an interference pattern which is recorded by a digital image sensor. The recorded interference pattern the hologram is then processed computationally to produce a holographic image. ROBUST SEGMENTATION The foundation of quantitative analysis is the ability to identify discrete events for quantification: In the line profile of the traditional phase contrast image the background value cannot be accurately determined and a characteristic bright halo around the edge of the cells is present. This type of image does not lend itself for reliable segmentation. HOLOMONITOR SEGMENTATION µm Intensity PHASE CONTRAST DIGITAL AUTOFOCUS The fine focusing is done entirely in software, after recording. The digitally recorded interference pattern is computationally processed to create holographic images over a range of focal distances. From this temporary stack of images, HoloMonitor M4 automatically selects the best in focus image to produce the final holographic image. Alternatively, users may manually select the focal distance to focus on a plane of interest. In contrast, holographic images can be quantified as they reflect the optical thickness of the cell and optical density variations in the specimen. Additionally, holographic images have a background level of zero and the intensity of the events measured as positive values. HoloMonitor methodology enables reliable segmentation seen in the image as yellow cellular boundaries defined by a proprietary software algorithm.

An essential and versatile tool for label-free kinetic cell analysis HIGH TEMPORAL RESOLUTION Label-free cell cultures are continuously monitored and analyzed in their natural environment. With the ability to acquire one image per second, both short-term monitoring of transient events in second intervals, and multi-day studies with images captured at user-defined intervals, are possible. HOLOMETRICS Quantitative phase shift measurements are translated by sophisticated software algorithms into morphological parameters optical cell volume, thickness, texture and many more. AREA THICKNESS VOLUME TEXTURE IRREGULARITY 3:48 0:00 LABEL-FREE SAMPLES As samples are analyzed unstained, no sample preparation is required, and most importantly, cellular function is not altered by toxic stains. 3:52 06:08 06:18 06:22 06:26 06:52 5:16 LONG-TERM EVALUATION The incubator-tolerant design makes HoloMonitor M4 especially well-suited for long-term kinetic cellular analysis. The low intensity, single wavelength laser generates no heat and reduces the risk of photodamage to an absolute minimum. 5:32 MOTORIZED STAGE HoloMonitor M4 may optionally be equipped with a motorized stage. The high precision stage allows HoloMonitor M4 to record time-lapse movies at multiple locations, in parallel. Sample locations may be within the same culture or in different in cultures. The stage control software is fully integrated in the HoloMonitor software. After sample locations have been graphically programed, time-lapse movies will be automatically recorded at each location. FLEXIBILITY IN EXPERIMENTAL DESIGN Many different sample vessels can be analyzed from chamber slides to Petri dishes and culture flasks. RELIABLE AND COST-EFFECTIVE OPERATION A new and innovative mechanical design together with intuitive software interface makes HoloMonitor M4 operation simple and reliable.

Simple workflow Intuitive user interface Proprietary software HoloStudio RECORD TIME-LAPSE Position the vessel on the mechanical stage and record a time-lapse. The total recording time and time interval between image captures are operator-determined. VIEW IMAGES View images and time-lapse movies in gray scale and color, 2D and 3D. Color variations represent differences in optical thickness. Adjusting threshold allows digital filtering of cells of interest. SEGMENT CELLS Choose one of many available segmentation strategies and fine-tune by adjusting background threshold and cell size. TRACK CELLS Select individual cells to simultaneously track cell movement and changes in cell morphology over time. Individual cell movements are displayed in spatial plots with related quantitative parameters. ANALYZE AND DISPLAY DATA Perform comprehensive automated analysis with options to display quantitative and morphometric features in two dimensional histograms and scattergrams. Data verification is done based on images (example mitotic cells). EXPORT The time-lapse movies can be viewed and effortlessly exported. The acquired images can be easily saved in common image file formats. Additionally, data can be exported as XML, to Excel or easily processed in multiple freeware programs.

HoloMonitor gives a totally new dimension to our work TECHNICAL SPECIFICATIONS Sample stage Fixed, manual XY-stage or motorized XYZ-stage Light source External laser unit, 635 nm Sample illumination 635 nm, 0.2 mw/cm 2 Objective 20 Lateral resolution 1 μm Field of view 0.25 mm 2 Working distance 0.5 2 mm HoloMonitor offers unique imaging capabilities that greatly enhance our understanding of cell behavior, previously unachievable by other technologies. Ed Luther, Supervisor of Core Imaging and Cytometry Facility, Northeastern University, Boston, USA HoloMonitor gives a totally new dimension to our work. Prof. Stina Oredsson, Department of Biology, Lund University, Sweden Autofocusing range Maximum image rate Image size Travel range Manual XY-stage Motorized XYZ-stage Dimensions (L W H) Weight 1.5 mm 1 image/s 1024 1024 pixel 70 50 mm 100 70 10 mm 250 160 180 mm 2.5 kg HoloMonitor allows non-invasive monitoring of cancer cells and their response to treatment, without the need for prior cell extraction, staining or exposing cells to harmful light sources. Dr. Maria Falck Miniotis, Researcher, Malmö University, Sweden HoloMonitor M4 allows us to rapidly measure how cell motility is affected by various treatments, without removing the cells from our incubator. Dr. Sung-Kyun Ko, Researcher, Korea Research Institute of Bioscience & Biotechnology, South Korea Requirements Cells Cell culture vessels Computer Incubator Operating temperature Monolayer of adherent T25, 6-well, Petri, IBIDI Windows 7/8 64-bit, 8GB RAM Access port for cabling 10 40 C 180 mm Operating humidity Max 95% 250 mm 160 mm Regulatory compliance Low voltage directive 2006/95/EC, Electromagnetic compatibility 2004/108/EC EN61010-1:2001 EN60825-1:2007 For research use only. Not for use in diagnostic procedures. Phase Holographic Imaging PHI AB HoloMonitor and HoloMetrics are registered trademarks of PHI Scheelevägen 22, 223 63 Lund, Sweden +46 46 38 60 80 info@phiab.se www.phiab.se 2015 Phase Holographic Imaging PHI AB All rights reserved