Instruction manual for STA 1 sectional door operator

Similar documents
Instruction manual for STA 1 sectional door operator

Operating Instructions K-POWERgrip EWL Always on the safe site.

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operating Instructions for Phase Demodulator Type _.2

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Motor spindle Operating Instructions. Ref

XY-Stages series 5102

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Tube Facing Tool.

Operating manual. TruTool N 500 (1A1) english

Top spin Nr /

Operator's manual. TruTool N 1000 (1B1) english

- 4 - Fig. 3b. Fig. 1b. Fig. 2. Fig. 2b MT 300

Lexium integrated drives

Rotary Measurement Technology Incremental Encoders

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Knife grinding machine K3 H/K

Operator's manual. TruTool N 1000 (1B1)

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

7. Operating instructions: EFL 300

Operating Manuel. High Speed Screw Jack G1-G3. Model N/V/R. NEFF-High Speed Screw Jacks G1-G3. Version N/V/R

Installation and Operational Instructions for ROBA -DX Couplings Type 931.3

TPM + Lenze ECS. Quick Startup Guide D Revision: 02

RoHS. High shaft load capacity. Shock / vibration resistant

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a

Rotary Position Technology Incremental Encoders

Original operating instructions Fail-safe inductive sensor GG507S

LENORD. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with little space. +BAUER... automates motion.

The object of these Operating Instructions is to assist you in the correct safe and economical use of the TORSIOMAX torque screwdriver.

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

Power supply CP-D 24/4.2 Primary switch mode power supply

Operator's manual TruTool PN 130 (1A1)

Absolute Encoders Multiturn

References 1 for asynchronous motors 1

Cat. No. I208E-EN-01A. Delta 2 TWIN Robot. CR_UGD21000T Series USER S MANUAL

Operator's manual. TruTool TKF 1100 (1A1) TruTool TKF 1101 (1A1)

Product Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications

Magnetic Inductive Flow Sensor induq

CHAINSAW SHARPENER MODEL: ECSS-1

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Absolute Encoders Multiturn

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Operator's manual. TruTool N 200 (1A1) english

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

Installation and Operational Instructions for primeflex -couplings Types 933._33.1 / 933._35.1 / 933._66.1 / 933._67.1

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Operation manual Torsional stiff all metal couplings according to KWN 21016

Cat. No. I207E-EN-01. Delta Robot. Delta Robot 2 Axes + 1 Rot USER S MANUAL

Optical encoder MEC22 HR

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

Original operating instructions Fail-safe inductive sensor GM705S


Rotary actuators for ball valves

Operator's manual. TruTool N 700 (1A1) english

Phone: Fax: Web: -

Wind Transmitter - with frequency output xx.xxx

TPM + power. Bosch Rexroth IndraDrive. Quick Startup Guide D Revision: 02

KRF EMC Filters Installation, Operation and Maintenance Manual

COFFEE LABORATORY WHITE STONE VA TEL

Modular Clamping Rail System SL120 & SL080

Wind Transmitter First Class Advanced Classified according to IEC ( )

Operator's manual. TruTool TKF 1500 (1A1), (1B1)

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Electrical data Units FVS 58, FHS 58. Operating voltage (PELV) [VDC] Current consumption at 24 VDC [ma] 85

Wind Transmitter - with analogue output xxx

Operating Instructions for Control CS 500

ESR. The Dynamic Solution. Applications. Products, Consultation, and Service. ESR Pollmeier GmbH

Absolute Encoders Singleturn

Data Sheet MEM 16. Incremental Encoder Magnetic

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Assembly instructions

U-Series. Subsea Screw Jacks & Bevel Gearboxes

External brake resistor AX2090-BW5x

Installation Instructions RF-identification system Read/write head ANT513

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Wind Transmitter - compact

The World of Motion Control

T22. Torque transducer. Special features. Data sheet

Power supply CP-D 12/2.1

TUCANA-02 P PORTABLE END MILLING MACHINE USER S MANUAL

SEPARATOR P20G TYPE USER S MANUAL

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

Translation of the Original Operating Manual. AutoCUT 500

CLAMPEX KTR 401 Operating/Assembly instructions. 1 Technical data 2

DTMA-1800-UMTS-12-AISG

Power consumption Operation At rest Wire sizing

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Precipition Sensor with analogue Intensity Output ,

Wind Transmitter First Class

QUINT-PS/ 3AC/24DC/10

Operator Manual. Booklet Maker BM 60. Doc No. T10171

Transcription:

Instruction manual for STA 1 sectional door operator GB Sectional door operator STA 1 / Rev. 0.0 1

1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions 2 4. Overview of products 3 5. Installation 8 6. Initial Operation 10 7. Emergency operation 15 8. Maintenance 17 9. Technical data 18 10. EU Declaration of Conformity 21 2. Key to symbols Danger of personal injury! The safety instructions must be observed! Warning! Danger to property! The safety instructions must be observed! Information Special information OR Reference to other sources of information Guarantee The function and safety of the equipment is only guaranteed if the warning and safety instructions included in these operating instructions are adhered to. MFZ Antriebe GmbH + Co.KG is not liable for any personal injury or damage to property that occurs as a result of the warning and safety instructions being disregarded. MFZ does not accept any liability or warranty for damage due to the use of non-approved spare parts and accessories. Using the equipment for its intended purpose The operators of the STA 1 range are designed exclusively for opening and closing weight counterbalanced sectional doors. Target group Only qualified and trained specialists are permitted to install and service the operator. Qualified and trained professionals fulfil the following requirements: - knowledge of the general and specific safety and accident prevention regulations, - Knowledge of the relevant regulations, - trained in the use and care of appropriate safety equipment, - Capable of recognising the dangers associated with installation. Only qualified and trained electricians may connect, programme and service the controls. Qualified and trained electricians meet the following requirements: - knowledge of the general and specific safety and accident prevention regulations, - knowledge of the relevant electrical regulations, - trained in the use and care of appropriate safety equipment, - capable of recognising the dangers associated with electricity. Instructions for installation and connection - The controls must be disconnected from the electricity supply before carrying out electrical works. It must be ensured that the electricity supply remains disconnected during the works. - Local protective regulations must be complied with. - Mains cables and control cables must be laid separately. 2 Sectional door operator STA 1 / Rev. 0.0

4. Overview of products GB Regulations and bases for testing For connecting, programming and servicing, the following regulations must be observed (the list is not exhaustive). Construction product standards - EN 13241-1 (Products without fire resistance or smoke control characteristics) - EN 12445 (Safety in use of power operated doors - Test methods) - EN 12453 (Safety in use of power operated doors - Requirements) - EN 12635 (Industrial, commercial and garage doors and gates - Installation and use.) - EN 12978 (Safety devices for power operated doors and gates - Requirements and test methods) Electromagnetic compatibility - EN 55014-1 (Radio disturbance, household appliances) - EN 61000-3-2 (Disturbances in supply systems - harmonic currents) - EN 61000-3-3 (Disturbances in supply systems - voltage fluctuations) - EN 61000-6-2 (Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments) - EN 61000-6-3 (Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light- industrial environments) 4.1 Various options The following package options are available for the STA1 operator: - STA/STAW 1 E (external control unit with release mechanism) - STA/STAW 1 KE (external control unit with chain) - STA/STAW 1 KU (external control unit with emergency hand crank) - STA/STAW 1 E - 100% ED (external control unit with release mechanism, 100% duty cycle) - STA/STAW 1 KE - 100% duty cycle (external control unit with chain, 100% duty cycle) - STA/STAW 1 KU - 100% duty cycle (external control unit with emergency hand crank, 100% duty cycle) - STAC 1 E (integrated control unit with release mechanism) - STAC 1 KE (integrated control unit with chain) - STAC 1 KU (integrated control unit with emergency hand crank) Machinery guidelines - EN 60204-1 (Safety of machinery, electrical equipment of machines, part 1: general requirements) - EN 12100-1 (Safety of machinery. Basic concepts, general principles for design. Basic terminology, methodology) Low voltage - EN 60335-1 (Household and similar electrical appliances - Safety) - EN 60335-2-103 (Particular requirements for drives for gates, doors and windows) Professional association (D) - BGR 232 (Directive for Power-driven Windows, Doors and Gates) Sectional door operator STA 1 / Rev. 0.0 3

4. Overview of products 4.2 Overview STA/STAW 1 KE STA/STAW 1 E ø 120 55 105140 243 425 150 330 372 145 108 54 M8 3,3 6,35 ø 25,4 104 4 Sectional door operator STA 1 / Rev. 0.0

GB STA/STAW 1 KU STA/STAW 1 E - 100% ED 55 140 105 243 ø 120 55 105140 243 415 150 145 108 54 M8 ø 120 330 145 108 54 M8 3,3 324 6,35 ø 25,4 3,3 6,35 ø 25,4 104 104 430 379 150 175 Sectional door operator STA 1 / Rev. 0.0 5

4. Overview of products STA/STAW 1 KE - 100% ED STA/STAW 1 KU - 100% ED ø 120 55 105140 243 55 105140 243 430 379 150 324 145 108 54 M8 145 108 54 M8 ø 120 3,3 6,35 ø 25,4 3,3 6,35 ø 25,4 104 104 429 366 150 175 6 Sectional door operator STA 1 / Rev. 0.0

GB STAC 1 E STAC 1 KE 55 140 243 108 54 M8 ø 120 425 346 330 372 145 3,3 6,35 ø 25,4 104 Sectional door operator STA 1 / Rev. 0.0 7

4. Overview of products 5. Installation STAC 1 KU 5.1 Preparation 145 108 54 M8 ø 120 55 140 105 243 Danger! To avoid injury, the following points must be observed: - The operator must be installed free of any tension. - The operator must not move on the shaft. - The design and subsurface of all components must be suitable for the forces encountered. 3,3 330 6,35 ø 25,4 Warning! To avoid damage to the operator and the door, the operator must only be fitted if - the operator is undamaged, - the ambient temperature is -10 ºC to +60 ºC., - the altitude of the location does not exceed 1,000 m, - a suitable protection type has been selected. 415 346 104 Before installation, ensure that - the operator is not blocked, - the operator has been newly prepared after a lengthy storage period, - all connections have been carried out correctly, - the direction of rotation of the drive motor is correct, - all motor protective devices are active, - no other sources of danger exist, - the installation site has been cordoned off over a wide area. 8 Sectional door operator STA 1 / Rev. 0.0

GB 5.2 Push-on assembly Solid shaft Mounting with torque support bracket Warning! To avoid damage to the operator and to the door, the operator must be mounted on a console or a torque support bracket so that it is vibration damped. B A C Check whether the feather key is suitable for the spring shaft on site. D Fit the torque support bracket/console (A). Grease the spring shaft (B) around the operator seating. Insert the feather key (C) into the spring shaft (B). Place the operator (D) on the spring shaft (B). Secure the feather key (C) against any movement. Information: The feather key can be secured with two hose clamps or adjusting rings. Fix the operator to the torque support bracket with 4 screws. Sectional door operator STA 1 / Rev. 0.0 9

5. Installation 5.3 Installation of the emergency hand chain (only for operators with emergency hand chain) Information: To ensure that they work correctly, the chain links must not be twisted. 6. Initial Operation 6.1 Preparation Warning! To avoid damage to the operator, the following points must be observed: - The types of cable and their diameters must be selected according to current regulations. - The nominal currents and the type of connection must correspond to those on the motor type plate. - The drive details must agree with the connected loads. Information: When operated with electronic control units, the corresponding start-up instructions and circuit diagrams must be complied with. Join the ends of the emergency hand chain together with the chain connecting link. Warning! To avoid damage to the operator and the door, the emergency hand chain must be secured while the door is operated electrically. 10 Sectional door operator STA 1 / Rev. 0.0

GB 6.2 Connection 3 x 400 V star connection (standard) Open the operator Danger! To avoid injury, the system must be disconnected from the power supply during the cabling work. The system must be safeguarded against being unintentionally switched on again during the work. A B C A Terminal 1 B Terminal 4 C Terminal 2 Remove the cover from the operator. S1 S2 S3 S4 S5 S6 OPEN additional limit switch (standard only in the case of operators without integrated control unit) Limit switch, OPEN Safety limit switch, OPEN Safety limit switch, CLOSE Limit switch CLOSED CLOSED additional limit switch (standard only in the case of operators without integrated control unit) Insert the cables Feed the cables through the screw fitting into the operator. Sectional door operator STA 1 / Rev. 0.0 11

6. Initial Operation 3 x 400 V star connection (pluggable) The motor is factory-wired for connection to a 3 x 400 V mains supply in star connection. Identification of wires U1 Red V1 Blue W1 White V2 W2 U2 Black Brown Green A B C D E F G Potential-free connection OPEN Potential-free connection CLOSE Switch off safety circuit Switch off OPEN end position Switch off CLOSED end position Internal safety circuit Operator A S1 S2 S3 S4 Additional limit switch, OPEN (standard only for operators without integrated control unit) Limit switch, OPEN Safety limit switch, OPEN Safety limit switch, CLOSED B C S5 S6 S7 F2 Limit switch, CLOSED Additional limit switch, CLOSED (standard only for operators without integrated control unit) Safety limit switch for emergency manual operation Thermal overload protection for motor D E 3 x 230 V delta connection To connect the operator to a 3 x 230 V mains supply, please consult the manufacturer. F G Connect all the cables required. 12 Sectional door operator STA 1 / Rev. 0.0

GB 6.3 Manual settings G H I J K L A B C D E F A B C D E F G H I J K L OPEN additional limit switch - S1 (potential-free change-over contact) Limit switch, OPEN - S2 Safety limit switch, OPEN - S3 Safety limit switch, CLOSED - S4 Limit switch, CLOSED - S5 Additional limit switch, CLOSED - S6 (potential-free change-over contact) Control cam for additional limit switch, OPEN (green) Control cam for limit switch, OPEN (green) Control cam for safety limit switch, OPEN (red) Control cam for safety limit switch, CLOSED (red) Control cam for limit switch, CLOSED (white) Control cam for additional limit switch, CLOSED (white) M N Fine adjustment screw Locking screw Each control cam has a locking screw (M) and a fine adjustment screw (N). The locking screw (M) is used to lock the corresponding control cam in the desired position. Finer adjustment can be made with the fine adjustment screw (N). Set the CLOSED end position Drive the door to the CLOSED end position. Set the control cam (K) so that the CLOSED limit switch (E) is actuated. Tighten the locking screw (N). M N The CLOSED safety limit switch (D) must be set in such a way that it switches immediately when the CLOSED limit switch (E) is passed over. Adjust the CLOSED safety limit switch (D). Sectional door operator STA 1 / Rev. 0.0 13

6. Initial Operation Set the OPEN end position Drive the door to the OPEN end position. Set the control cam (H) so that the OPEN limit switch (B) is actuated. Tighten the locking screw (N). Wiring allocation, AVE (absolute value encoder) plug The OPEN safety limit switch (C) must be set in such a way that it switches immediately when the OPEN limit switch (B) is passed over. Adjust the OPEN safety limit switch (C). 6.4 Digital settings Limit switch and safety circuit for drive Electronic interface The numbers on the plug are also the wire-numbers. 4: Safety circuit input 5: RS 485 B 6: GND 7: RS485 A 8: Safety circuit output 9: 7...18V DC AVE (absolute value encoder) plug terminal (7-12) A B A: AVE plug (absolute value encoder plug) B: AVE plug terminal (absolute value encoder plug terminal) Information: Please refer to the control unit operating manual for instructions on setting the end positions. C: Thermal element in the drive D: Manual emergency control (emergency crank or emergency chain) 14 Sectional door operator STA 1 / Rev. 0.0

7. Emergency operation GB 6.5 Check the system Check the direction of travel Drive the door in the CLOSED direction. The operator must close the door. Drive the door in the OPEN direction. The operator must open the door. Information: If the direction of travel of the door does not correspond to the commands keyed in, then the direction of rotation must be changed. Instructions for changing the direction of rotation are given in the control unit operating manual. After this the direction of travel must be checked again. Danger! To avoid injury, the following points must be observed: - Emergency operation may only be carried out from a safe standing position. - Emergency operation may only be carried out when the motor is stationary. - The system must be disconnected from the power supply during emergency operation. During maintenance works or in the case of an electrical fault, the door can be moved towards the OPEN or CLOSED positions with the help of the emergency operation equipment. Information: If the door is moved beyond the CLOSED or OPEN end positions, the operator can no longer be activated electrically. Check the limit switch settings Drive the door to the CLOSED end position. The operator must stop in the desired position. Operation with emergency hand chain Drive the door to the OPEN end position. The operator must stop in the desired position. Check the seat of the fixing screws. Check the mechanical functions After assembling and installing all components the functions of the system must be checked. Check all the functions of the system. Check that the operator runs smoothly. Check whether the operator is leaking oil. If the operator makes unusual noises or leaks oil: - The operator must be taken out of service immediately, - The customer service must be informed. Release the emergency hand chain from its fixing. Move the door in the OPEN or CLOSE direction by pulling on the emergency hand chain on the side concerned. Sectional door operator STA 1 / Rev. 0.0 15

7. Emergency operation Operation with emergency hand crank Operation with release mechanism Push the emergency hand crank into the operator as far as it will go. Move the door in the OPEN or CLOSE direction by turning the emergency hand crank. Remove the emergency hand crank from the operator after completing emergency manual operation. Pull on the red loop. The gate can be moved manually. Pull on the green loop. The door can be moved with the operator. Warning! In the case of drive units with a release mechanism, a fall protection must be mounted on the door so that the door complies with directive BGR 232. 16 Sectional door operator STA 1 / Rev. 0.0

8. Maintenance GB Warning! To avoid damage to the operator and door, the following points must be observed: - Maintenance must only be carried out by authorized persons. - Directive BGR 232 must be complied with. - Worn or faulty parts must be replaced. - Only approved parts may be installed. All maintenance work must be documented. Information: The drive unit has lifetime lubrication and is maintenance-free. Check that all mountings have been securely tightened. Check the spring tension on the door. The springs must be adjusted so that they are weight counterbalanced. Check the brake (if available). Check the limit switches and safety switches. Check for noises and oil leaks. Check the mounting of the operator for corrosion. Check the housing for damage. Sectional door operator STA 1 / Rev. 0.0 17

9. TECHNICAL DATA Typ (E/KU/KE) STA 1-11-19 STA 1-10-24 STA 1-13-15 STA 1-12-19 STA 1-11-24 STA 1-10-30 Driving Torque (Nm) 110 100 130 120 110 100 Maximum safety catch torque (Nm) - - - - - - Permissible torque (Nm) - - - - - - Driving motor speed (min -1 ) 19 24 15 19 24 30 Motor output (kw) 0,37 0,37 0,55 0,55 0,55 0,55 Operating voltage (V) 400 / 3~ 400 / 3~ 400 / 3~ 400 / 3~ 400 / 3~ 400 / 3~ Mains frequency (Hz) 50 50 50 50 50 50 Control voltage (V) 24 24 24 24 24 24 Nominal motor current (A) 1,85 2,1 2,4 2,4 3,0 3,0 Motor duty cycle (%) 60 60 60 60 60 60 Cable on site (mm 2 ) 5G1,5 5G1,5 5G1,5 5G1,5 5G1,5 5G1,5 Fuse protection on site (A) 10 10 10 10 10 10 Protection type (IP) 54 54 54 54 54 54 Temperature range ( o C) -10 / +60-10 / +60-10 / +60-10 / +60-10 / +60-10 / +60 Continous sound pressure level (db (A)) <70 <70 <70 <70 <70 <70 Weight per piece (kg) 13 / 13 / 15 13 / 13 / 15 13 / 13 / 15 13 / 13 / 15 13 / 13 / 15 13 / 13 / 15 Max number of revolutions of driven shaft 13 13 13 13 13 13 Hollow shaft (mm) 25,4 25,4 25,4 / 31,75 25,4 / 31,75 25,4 / 31,75 25,4 / 31,75 18 -Sectional door operator STA 1 / Rev 0.0

GB Type (E / KU / KE): STA 1 13-15 100% STA 1 12-19 100% STA 1 11-24 100% STA 1 10-30 100% STAW 1 7-19 Driving torque (Nm): 130 120 110 100 70 Maximum safety catch torque (Nm): - - - - - Permissible torque (Nm): - - - - - Driving motor speed (min -1): 15 19 24 30 19 Motor output (kw): 0,55 0,55 0,55 0,55 0,37 Operating voltage (V): 400 / 3~ 400 / 3~ 400 / 3~ 400 / 3~ 230 / 1~ Mains frequency Hz: 50 50 50 50 50 Control voltage: (V): 24 24 24 24 24 Nominal motor current (A): 2,4 1,8 1,75 1,5 4,8 Motor duty cycle (%): 100 100 100 100 25 Cable on site (mm 2 ): 5 x 1,5 5 x 1,5 5 x 1,5 5 x 1,5 3 x 1,5 Fuse protection on site (A): 10,0 10,0 10,0 10,0 10,0 Protection type (IP) 54 54 54 54 54 Temperature range ( C): -10 / +60-10 / +60-10 / +60-10 / +60-10 / +60 Continuous sound pressure level (db (A)): < 70 < 70 < 70 < 70 - Weight per piece (kg): 18 / 18 / 23 18 / 18 / 23 18 / 18 / 23 18 / 18 / 23 13 / 13 / 15 Maximum number of revolutions of driven shaft: 13 13 13 13 13 Hollow shaft (mm): 25,4 / 31,75 25,4 / 31,75 25,4 / 31,75 25,4 / 31,75 25,4 Sectional door operator STA 1 / Rev. 0.0 19

9. Technical data Type (E / KU / KE): STAC 1 11-19 STAC 1 10-24 STAC 1 13-15 STAC 1 12-19 Driving torque (Nm): 110 100 130 120 Maximum safety catch torque (Nm): - - - - Permissible torque (Nm): - - - - Driving motor speed (min -1): 19 24 15 19 Motor output (kw): 0,37 0,37 0,55 0,55 Operating voltage (V): 400 / 3~ 400 / 3~ 400 / 3~ 400 / 3~ Mains frequency Hz: 50 50 50 50 Control voltage: (V): 24 24 24 24 Nominal motor current (A): 1,85 2,1 2,4 2,4 Motor duty cycle (%): 60 60 60 60 Cable on site (mm 2 ): 5 x 1,5 5 x 1,5 5 x 1,5 5 x 1,5 Fuse protection on site (A): 10,0 10,0 10,0 10,0 Protection type (IP) 54 54 54 54 Temperature range ( C): -10 / +60-10 / +60-10 / +60-10 / +60 Continuous sound pressure level (db (A)): < 70 < 70 < 70 < 70 Weight per piece (kg): 13 / 13 / 15 13 / 13 / 15 13 / 13 / 15 13 / 13 / 15 Maximum number of revolutions of driven shaft: 13 13 13 13 Hollow shaft (mm): 25,4 25,4 25,4 / 31,75 25,4 / 31,75 20 Sectional door operator STA 1 / Rev. 0.0

10. EU Declaration of Conformity GB Manufacturer: Ovitor Oy, Sienitie 24, 00760 Helsinki, Finland We hereby declare that, by virtue of their conceptual development and design, as well as their manufacture as we have brought them onto the market, the products cited below: Sectional door operator STA1 conform to the relevant basic health and safety regulations of the following EU guidelines and standards: EU Construction Products Directive 89/106/EU DIN EN 13241-1 DIN EN 12453 DIN EN 12445 DIN EN 12978 EU Electromagnetic Compatibility Directive 89/336/ EU EN 55014-1 EN 61000-3-2 EN 61000-3-3 EN 61000-6-2 EN 61000-6-3 EU Machinery Directive 98/37/EU EN 60204-1 EN ISO 12100-1 EU Low Voltage Directive 73/23/EU EN 60335-1 EN 60335-2-103 BGR 232 - Directive for Power-driven Windows, Doors and Gates Directive for Power-driven Windows, Doors and Gates Legden, 2 January 2007 Manufacturer s signature: Hans-Joachim Molterer Position of signatory: Manager Sectional door operator STA 1 / Rev. 0.0 21

22 Sectional door operator STA 1 / Rev. 0.0

Sectional door operator STA 1 / Rev. 0.0 23 GB