Machine Tool & Gear 1021 N. Shiawassee St. Corunna, MI Temperature Uniformity Survey Report

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Scope of Accreditation For OV Scale Corporation I-70 Exit 11 Wheeling, WV Brad Young

CERTIFICATE OF ACCREDITATION

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

ENERGY STAR MEASUREMENT AND TEST REPORT FOR Good Year Technologies CO.,LTD

Scope of Accreditation For Southwest Metrology, Inc. Calibration

Certified Reference Materials for UV, Visible, NIR and IR Molecular Spectroscopy

IESNA LM (NOT INCLUDE SPATIAL NON-UNIFORMITY OF CHROMATICITY) ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS

Certificate of Accreditation

Certificate of Calibration

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

CERTIFICATE OF ACCREDITATION

Certificate of Accreditation

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

TRANSMITTER MODEL: KAS-2030M

CENTRE OF TESTING SERVICE INTERNATIONAL

Calibration Certificate

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z

Certificate of Accreditation

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Certificate of Calibration

Certificate of Accreditation

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE of CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ROKU REMOTE MODEL: RC07

Calibration Specialists Ltd

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No.

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Morris Products 53 Carey Road, Queensbury, NY 12804

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Cat# LED Classic Large Wall-Pack

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

CALIBRATION AND MEASUREMENT CAPABILITY (CMC) 1,2

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Manufacturer Calibration Certificate

IES LM MEASUREMENT AND TEST REPORT. Test Model: SRLED-RTUS24-4K. Jeanne Han/Safety Manager

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Certificate of Accreditation

Torque Sensor Accessories and Services

Certificate of Accreditation

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

525B Temperature/ Pressure Calibrator Superior accuracy and functionality in an economical benchtop package

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z & ANSI/NCSLI Z

TABLE OF CONTENTS SECTION TITLE PAGE. 5. LIST OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 EUT and Accessory List EMI Test Equipment

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z , & ANSI/NCSL Z

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Certificate of Accreditation

CALIBRATION & MEASUREMENT CAPABILITY 1 (CMC) (±) 0.5 C 0.05 C C 0.37 C 0.15 C 0.86 C C %Rh 0.95 %Rh 1.2 %Rh 0.085% IR 0.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

This annex is valid from: to Replaces annex dated:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 10

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

Certificate of Accreditation

Certificate of Accreditation

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z , & ANSI/NCSL Z

Certificate of Accreditation

CERTIFICATE OF ACCREDITATION. ANSI/NCSL Z (R2002) and ANSI/NCSL Z (R2013)

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NSCL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ZETEC, INCORPORATED 875, boul. Charest ouest, Suite 100 Quebec, QC, G1N 2C9 CANADA

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

Transcription:

Machine Tool & Gear 1021 N. Shiawassee St. Corunna, MI 48817 Temperature Uniformity Survey Report Report Time: 11:24 AM Report Date: 5/18/2018 Furnace: DRA012 Furnace Information Survey Result: Furnace Mfg.: N/A Furnace Type: Batch Operating Range: 300-400 F Furnace Dimensions: 44" x 54" x 36" Process Table: A Work Zone Volume: 46.8 Cu. Ft. Controller Mfg.: SSI Instrument Type: N/A Controller Model: 9130 Overtemp Inst.: SSI 7sL Controller S/N: MTG-001 Overtemp Inst. S/N: MTG-002 Offset as found/as left: 0 F Survey Information Survey Date: 5/15/2018 Survey Performed By: Seth Uldricks Frequency: Annual Survey Time: 10:10:00 AM Next Survey Due: 5/15/19 Overtemp Setpoint: 450 F Uniformity Required: ±20 F Survey Setpoint: 300 F TUS Per: CQI-9 Number of Thermocouples: 9 T/C Type: K SDS Touch Screen Rev. 1.0.0.29 T/C Cert Number: W-0712 DataLogger S/N: SDC150050 T/C Calibrated By: GeoCorp DataLoger CAL Date: 4/8/18 T/C Correction Factor: -0.3 F DataLoggerCalibrated By: Seth Uldricks T/C Calibration Date: 12/5/17 Pass REV. 0 Page 1 of 5

Survey Information: Temperature: F Specification: CQI-9 Survey Start Date & TIme: 5/15/2018 10:10:00 AM Survey End Date & Time: 5/15/2018 10:40:00 AM Sample Interval: 120s Overshoot: No Overshoot Time (if occurred): Furnace Condition: Empty Survey Structure: Empty Basket Atmosphere Present? No Furnace Chart: Customer Vacuum Pressure (if applicable) N/A Survey Notes: -TUS performed with heat sinks per customer request. -TUS performed using a single basket placed in the center of the workspace, per customer request. All displayed thermocouple values included in this report are CORRECTED. All correction values are identified in this report Heat Treating Services Unlimited,Inc.has been audited and found in compliance with ISO/IEC 17025:2005. Calibrations performed at the customers facility within the labs scope of accreditation are indicated by the presence of the Accrediting Body's logo and Cert# on this certificate of calibration. All results contained within this certification relate only to items calibrated. Any number of factors may cause the calibration item to drift out of calibration before the instruments calibration interval has expired. This report must not be used to claim product certification, approval or endorsement ny L.A.B., NIST, or any goverment agency. The standards used in these calibrations are traceable through the National Institute of Standards and Technology (NIST) or another National Metrology Institute to the International Systems of Units. Complete records of work performed are maintained by HTSU and are available for inspection. The results in this report relate only to the items calibrated or tested. When statements of compliance are made the measurement of uncertainty is not taken into account. The Uncertainty of Measurement is 0 to 1093 C = 1.1 C, 1093 to 1250 C = 2.7 C The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for normal distribution corresponds to a coverage probablilty of approximately 95%. Page 2 of 5

Graphical Trend Data / TC Survey Summary Temperature Setpoint: 300 F Tolerance: +/-20 F Minimum TC number: 9 Maximum TC number: 2 Minimum TC Value: 302.3 Maximum TC Value: 304.4 Min deviation from setpoint: 2.3 Max deviation from setpoint: 4.4 TC1 ( F) TC2 ( F) TC3 ( F) TC4 ( F) TC5 ( F) Minimum 303.5 (3.5) 303.7 (3.7) 302.7 (2.7) 303.0 (3.0) 302.7(2.7) Maximum 304.2 (4.2) 304.4 (4.4) 303.1 (3.1) 303.5 (3.5) 303.3 (3.3) Mean 303.9 304.1 303.2 303.1 (3.9) (4.1) (3.2) (3.1) Spread 0.7 0.7 0.4 0.5 0.6 TC6 ( F) TC7 ( F) TC8 ( F) TC9 ( F) Minimum 302.4 (2.4) 302.6 (2.6) 302.5 (2.5) 302.3 (2.3) Maximum 303.2 (3.2) 303.1 (3.1) 303.1 (3.1) 302.8 (2.8) Mean 302.8 (2.8) Spread 0.8 0.5 0.6 0.5 Thermocouple Wire Correction Factor: -0.3 302.6 (2.6) Page 3 of 5

Thermocouple Placement for 300 F Survey 1 0.5 2 0.7 3 0.5 4 0.2 5 0.5 6 0.3 7 0.3 8 0.5 9 0.4 Data Collection Unit Offsets by Channel Quality Approval Customer Approval Page 4 of 5

Survey Date: 5/15/2018 Furnace: DRA012 Survey TC Data Time TC1 TC2 TC3 TC4 TC5 TC6 TC7 TC8 TC9 10:10:00 AM 304.2 304.3 303.0 303.0 303.3 303.1 303.0 303.1 302.6 10:12:00 AM 304.2 304.3 302.8 303.2 303.3 303.0 303.1 302.7 10:14:00 AM 304.0 304.3 303.1 303.3 303.2 303.0 303.0 302.6 10:16:00 AM 304.0 304.4 303.1 303.3 303.3 303.0 303.1 302.8 10:18:00 AM 304.0 304.1 303.2 303.3 302.8 302.8 302.8 302.6 10:20:00 AM 303.8 304.0 302.8 303.2 302.7 302.6 10:22:00 AM 303.9 304.0 302.8 303.2 302.8 302.6 10:24:00 AM 303.9 304.1 303.0 303.3 303.1 302.7 302.8 302.8 302.5 10:26:00 AM 304.0 304.1 303.0 303.3 303.3 303.0 303.0 302.6 10:28:00 AM 304.0 304.2 303.0 303.5 303.3 303.0 303.1 303.1 302.8 10:30:00 AM 303.9 304.1 303.0 303.5 303.3 302.8 303.0 302.7 10:32:00 AM 303.9 303.9 303.2 303.2 302.6 302.8 302.7 10:34:00 AM 303.6 304.0 303.1 303.1 302.6 302.8 302.8 302.5 10:36:00 AM 303.6 303.7 302.8 303.1 303.0 302.4 302.7 302.8 302.5 10:38:00 AM 303.5 303.7 302.8 303.1 302.5 302.6 302.5 302.3 10:40:00 AM 303.5 303.8 302.7 303.0 302.7 302.4 302.7 302.5 302.3 Approach TC Data Time TC1 TC2 TC3 TC4 TC5 TC6 TC7 TC8 TC9 9:34:00 AM 211.1 196.7 188.1 173.4 220.2 213.2 184.6 202.0 192.4 9:36:00 AM 244.6 230.1 219.1 201.3 244.2 239.1 217.8 231.6 222.8 9:38:00 AM 268.1 256.8 243.6 226.0 262.0 258.0 244.0 254.2 244.9 9:40:00 AM 281.6 273.1 260.5 244.5 274.8 271.2 260.7 268.8 261.5 9:42:00 AM 290.9 284.7 273.1 259.4 283.5 281.2 273.0 279.6 273.4 9:44:00 AM 296.6 292.5 282.4 271.2 290.5 288.9 282.5 287.4 282.0 9:46:00 AM 300.2 297.2 288.6 279.6 294.6 293.8 288.8 292.6 288.2 9:48:00 AM 302.2 300.2 293.1 286.1 297.7 296.9 293.0 295.9 292.2 9:50:00 AM 303.6 302.3 296.4 291.1 299.9 299.4 296.4 298.5 295.5 9:52:00 AM 304.2 303.5 298.4 294.5 301.1 300.9 298.6 300.2 297.7 9:54:00 AM 304.6 304.3 300.0 297.1 302.3 302.0 300.1 301.4 299.4 9:56:00 AM 304.7 304.5 301.0 299.0 302.8 302.6 301.2 302.0 300.6 9:58:00 AM 304.6 304.7 301.8 300.3 303.1 303.0 301.8 302.5 301.3 10:00:00 AM 304.7 304.7 302.1 301.4 303.2 303.1 302.3 302.8 301.8 10:02:00 AM 304.6 304.6 302.4 301.9 303.2 303.1 302.5 302.8 302.0 10:04:00 AM 304.2 304.5 302.6 302.4 303.3 303.2 302.6 303.0 302.1 10:06:00 AM 304.3 304.6 302.7 302.7 303.4 303.2 302.8 303.1 302.5 10:08:00 AM 304.3 304.6 302.8 303.0 303.4 303.3 303.0 303.2 302.7 10:10:00 AM 304.2 304.3 303.0 303.0 303.3 303.1 303.0 303.1 302.6 Page 5 of 5