Integrated Inductive Component Reduces Radiated Emissions in Power Applications

Similar documents
Electromagnetic Compatibility

Overview of the ATLAS Electromagnetic Compatibility Policy

ELEC Course Objectives/Proficiencies

Test and Measurement for EMC

TEST REPORT... 1 CONTENT...

MAGNETIC PRODUCTS. SMD Beads and Chokes

Design of EMI Filters for DC-DC converter

7. EMV Fachtagung. EMV-gerechtes Filterdesign. 23. April 2009, TU-Graz. Dr. Gunter Winkler (TU Graz) Dr. Bernd Deutschmann (Infineon Technologies AG)

EMC Evaluation at Green Bank: Emissions and Shield Effectiveness

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA

application note Philips Magnetic Products Cable Shielding Philips Components

"Natural" Antennas. Mr. Robert Marcus, PE, NCE Dr. Bruce C. Gabrielson, NCE. Security Engineering Services, Inc. PO Box 550 Chesapeake Beach, MD 20732

Output Filtering & Electromagnetic Noise Reduction

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

EMC Near-field Probes + Wideband Amplifier

Conducted EMI Simulation of Switched Mode Power Supply

Electromagnetic Compatibility at Green Bank: Evaluation and Mitigation

Ferroxcube Soft Ferrites (MnZn - NiZn) Company Introduction

AUTOMOTIVE ELECTROMAGNETIC COMPATIBILITY (EMC)

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

AIM & THURLBY THANDAR INSTRUMENTS

Correlation Between Measured and Simulated Parameters of a Proposed Transfer Standard

FERRITE CORE INDUCTOR VALUE VARIATION WITH NUMBER OF TURNS AND DIAMETER OF COPPER WIRE,LENGTH AND DIAMETER OF CORE

An Introduction to Radio Frequency Interference

SAS-562B Active Loop Antenna Operation Manual

SAS-563B Active Loop Antenna Operation Manual

Application of Soft Ferrite Material: from EMC to RFID

AIM & THURLBY THANDAR INSTRUMENTS

Categorized by the type of core on which inductors are wound:

AC Measurement of Magnetic Susceptibility

3A Step-Down Voltage Regulator

Current Probes. User Manual

Broadband Current Probe Series Operation Manual

Embedded inductor design and electromagnetic compatibility issues

Electro-Magnetic Interference and Electro-Magnetic Compatibility (EMI/EMC)

Ferrites for High Frequency Noise Suppression Chapter 9

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

2.0 EMI INTERFERENCE SUPPRESSION AND EMC ELECTROMAGNETIC COMPATIBILITY

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

High Voltage Charge Pumps Deliver Low EMI

Using Ferrites for High Frequency Noise Suppression

FUNDAMENTALS OF EMC. Candace Suriano John Suriano

GLOSSARY OF TERMS FLUX DENSITY:

Top Ten EMC Problems

Lecture 4. Maximum Transfer of Power. The Purpose of Matching. Lecture 4 RF Amplifier Design. Johan Wernehag Electrical and Information Technology

Switch Mode Power Supplies and their Magnetics

Trees, vegetation, buildings etc.

Application Note #60 Harmonic Measurement for IEC And other Radiated Immunity Standards

AT7450 2A-60V LED Step-Down Converter

Description RF Explorer RFEAH-25 1 is a 25mm diameter, high performance near field H-Loop antenna.

COMPLIANT Common Mode Chokes - UU9.8 & UU10.5 Series

Measurement and Analysis for Switchmode Power Design

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

EC6011-ELECTROMAGNETICINTERFERENCEANDCOMPATIBILITY

3C96 3C98 BEST IN CLASS

Electromagnetic interference at the mains ports of an equipment

ABB September Slide 1

Signal and Noise Measurement Techniques Using Magnetic Field Probes

Common myths, fallacies and misconceptions in Electromagnetic Compatibility and their correction.

SAS Log Periodic Antenna Operation Manual

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

What is an Inductor? Token Electronics Industry Co., Ltd. Version: January 16, Web:

EMC Components. RF Chokes High Current B82432-H. Data Book Supplement

Failing EMC testing? > 50% of products fail EMC testing first time around

TUTORIAL Inductor Loss Calculation in Thermal Module

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

EMI AND BEL MAGNETIC ICM

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

Properties of Inductor and Applications

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

Bulk Current Injection Probe Test Procedure

FISCHER CUSTOM COMMUNICATIONS, INC.

1 Introduction. Webinar sponsored by: Cost-effective uses of close-field probing. Contents

COOLTUBE Radiated Emissions Absorber

Hidden schematics of EMI filters

EMC Immunity studies for front-end electronics in high-energy physics experiments

Research Paper ELECTROMAGNETIC INTERFERENCE REDUCTION IN CUK CONVERTER USING MODIFIED PWM TECHNIQUES

Investigation of a Voltage Probe in Microstrip Technology

A Novel Measurement System for the Common-Mode- and Differential-Mode-Conducted Electromagnetic Interference

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Comparison of IC Conducted Emission Measurement Methods

Solving Electromagnetic Interference (EMI) with Ferrites

EMC-scanner. HRE-series. See it before you CE it!

Radiated EMI Recognition and Identification from PCB Configuration Using Neural Network

Saturation of Active Loop Antennas

Differential-Mode Emissions

T + T /13/$ IEEE 236. the inverter s input impedances on the attenuation of a firstorder

By Hiroo Sekiya, Chiba University, Chiba, Japan and Marian K. Kazimierzuk, Wright State University, Dayton, OH

EMC Refresh Presented by Sylvain LE BRAS Würth Elektronik eisos France

Testing for EMC Compliance: Approaches and Techniques October 12, 2006

INTRODUCTION TO CONDUCTED EMISSION

Course Introduction. Content 16 pages. Learning Time 30 minutes

Radiated noise measurement example using Tekbox TEM Cells

Advanced Test Equipment Rentals ATEC (2832)

Electromagnetic Integrated Solutions

4. THEORETICAL: EMISSION AND SUSCEPTIBILITY. pressure sensor, i.e, via printed-circuit board tracks, internal wiring which acts as an

Broadband Current Probe Series Operation Manual

Switched Mode Power Supply Measurements

SMT Inductors SIMID 1812-T B82432-T. Data Sheet

Transcription:

Integrated Inductive Component Reduces Radiated Emissions in Power Applications Author : Gabriel Arianes, David Castillo, Raquel Garcia and Oscar Perez 05/17/2002 The geometry of magnetic components can affect the incidence of unwanted low frequency radiation in the magnetic field. Gabriel Arianes, David Castillo, Raquel Garcia and Oscar Perez; Ferroxcube, Guadalajara, Spain INTRODUCTION The miniaturization trend has resulted in smaller components and greater board densities in electronic applications. This very density, which packs components into ever-smaller spaces, makes it more important than ever to examine the effect including possible damage each component may have on signals in nearby circuit paths and on other components. This article examines the way in which the geometry of magnetic components, such as inductors or transformers, may affect the incidence of unwanted, low-frequency radiation in the magnetic field. In the following experiment, commercially available inductors are used as an output choke in a DC/DC converter. Two types of inductors are used; drum cores which are magneticallyopen paths and an integrated inductive component (IIC) with a full gap and a magneticallyclosed path. MAGNETIC PATH The electrical properties of magnetic components, such as transformers and inductors, are based on three main parameters: The winding that transforms the electric current into a magnetic field. The magnetic properties of the material, such as magnetic permeability, that determine the magnetic flux induced by the magnetic field. The shape of the component that determines the path of the magnetic field. Figure 1. Flux distribution in a toroid (closed magnetic circuit) where no radiation can be noticed, and in a rod (open magnetic circuit) with radiation leaving the product. The relationship of these three parameters will determine the basic properties of the magnetic component. With relatively simple formulas, it is possible to calculate the inductance, maximum current, and power loss of the inductor i.e., most of the electrical parameters needed to design a component for a given application. Also, the geometry of the component will influence the

radiation capability of the magnetic component, a capability uninfluenced by any of the electrical parameters used in the design. For a clearer understanding of the crucial role of geometry vis-a-vis radiated emissions, magnetic components can be broken into two groups.first, in closed magnetic circuits, the magnetic flux remains inside the magnetic core, and most of the magnetic-field lines are closed lines surrounded by the winding. A good example of this first geometry is a toroid (Figure 1). Figure 2. An integrated inductive component (left) and a drum core (right) are shown. Second, in open magnetic circuits, the magnetic flux flows briefly in the magnetic core and is then radiated. The magnetic-field lines are open; or if they are closed, most of their length is not within the magnetic core but passes through the ambient air. A sample of the second geometry is a rod (Figure 1). In fact, there are many geometric configurations that will lead to designs that radiate to a greater or lesser extent depending on just how open they are. The products examined in this article are two examples of the aforementioned geometries and show similar electrical properties. Inductance is about 5 µh, DC resistance below 10 m., saturation current of approximately 7 A for the Integrated Inductive Component and approximately 10 A for the bobbin core. They have similar volumes: the IIC is about 576 mm3, and the bobbin core is about 650 mm 3 (Figure 2). WHY IS MAGNETIC RADIATION AN ISSUE? In many power applications, such as power conversion, magnetic components are subjected to high currents and, consequently, to very high magnetic fields. Depending on the core geometry, strong fields may be radiated. Such a low frequency field is relatively strong in the area near the magnetic components and most probably will couple with any loop present on any PCB close to the component. This likelihood means that harmful switching harmonics can appear anywhere in the circuit, degrading the quality of digital signals, or even damaging other ICs.Functionality may be the first criterion in choosing a component; but ultimately, the equipment containing that component must comply with EMC regulations. Several committees have set limits for both conducted and radiated interference. In Europe, CISPR 16 sets forth the measuring procedures/methods for such low frequency radiation (9 khz to 30 MHz). Measurement specifics applicable in the United States can be found in FCC, Part 15. TEST METHODS AND EXPERIMENTS

This experiment relies on the so-called van Veen method. 1 Using this method, the deviceunder-test (DUT) is placed within a loop antenna two meters in diameter. This loop antenna is made of RG223/U coaxial cable with two slits (fitted with resistor networks) placed symmetrically, each 90 from the current probe. Figure 3 depicts the antenna setup. Figure 3. Antenna loop used to carry out H-field measurements in the range 9 khz to 30 mmhz. The current probe translates the current in the loop to voltage. The current induced in the loop is measured by a current probe connected to a spectrum analyzer and is expressed in dbµa. In this test setup, the noise from the environment will be negligible as compared to the currents from the DUT. To check the effect of radiation, the DUT was connected to an RF power amplifier, using a 100-kHz square wave of 2.8-A amplitude. The objective of this experiment is to measure the radiation under similar conditions for both the open magnetic circuit and the closed magnetic circuit.

Figure 4. Radiation on a drum core and a IIC excited with a square wave: 100 khz, 2.9 Amps peak-peak. The square voltage becomes triangular current when passed across the inductors. The main frequency and the third harmonic can be seen at 100 and 300 khz. Figure 5. IIC and drum core working as output choke on a DC/DC converter, IIC shows negligible radiation (comparable with the noise generated by the rest of the circuitry), while on the drum core, two harmonics can be seen at 600 and 1800 khz. Figure 4 shows the radiation generated by both components expressed in dbµa; these results confirm that open circuits have much higher radiation levels than closed circuits. Note the amplitude of the harmonics. The difference between the two components is 8 dbµa at 100 khz (main frequency) and 6 dbµa at 300 khz (third harmonic). Given these figures, it can be derived that the difference in radiation is almost constant, independent of the amplitude of the signal. Consequently, the advantage of using closed magnetic circuits holds true in every case even where radiation is relatively low. The next experiment compared the inductors in a real application, a DC/DC converter working as an output choke. The converter is a standard design and the operating test conditions were as follows: 2.3-V output voltage delivering 2 A and a switching frequency of 600 khz. The results given in Figure 5 clearly depict the advantage of using the integrated inductive component versus the drum core. When the IIC is used, radiation levels stay within the radiation values of the overall system. At this higher frequency (600 and 1800 khz), there is a marked difference between the two components as compared to the disparity at low frequencies (100 and 300 khz). A comparison between Figures 4 and 5 shows that the radiation of the DC/DC converter is 5 dbµa, in the frequencies unaffected by the radiation of the inductors. CONCLUSION At low frequencies, both conducted and radiated interference should be taken into account. These design principles are necessitated not just by regulatory limits but by the demands for functionality and design integrity in the completed system. Magnetic components with a closed magnetic circuit design (e.g., an integrated inductive component) produce very little or negligible radiation. The use of IICs helps forestall such problems as inducing currents on the tracks, currents that could damage components, and currents that might influence other signals. These closed magnetic circuit devices are, therefore, well suited for use in any kind of equipment where other circuits or PCBs might be affected by magnetic radiation. REFERENCES

1. Goedbloed, Jasper J. Electromagnetic Compatibility (CISPR Publication 15). IEC. Geneva, Switzerland: 1992. 2. Ferroxcube Soft Ferrite and Accessories Handbook. Guadalajara, Spain: 2000 (inter alia). Gabriel Arianes, Development Engineer, can be reached at gabriel.arianes@ferroxcube.com or phone: +34 949 248814. David Castillo, Development Engineer, can be reached at david.castillo_2@ferroxcube.com or phone: +34 949 247176. Raquel García, Application Engineer, can be reached at raquel.garcia @ferroxcube.com or phone: +34 949 247161. Óscar Pérez, Development Engineer, can reached at oscar.perez @ferroxcube.com or phone: +34 949 247179. Source: http://www.interferencetechnology.com/integrated-inductive-component-reducesradiated-emissions-in-power-applications/