ClampOn DSP Leak Monitor

Similar documents
ClampOn DSP-06 Particle Monitor

ClampOn DSP-06 Subsea Particle Monitor

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

FGM 160 Ultrasonic Flaregas meter. Flare Gas Measurement

Ultrasonic sensors in subsea oil & gas production current use and opportunities

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

Model Sono-Trak Transit Time

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Technical Specification FLUXUS ADM 8x27

Subsea Control Systems

Coriolis Massflowmeter

Ring Pair Corrosion Monitor : RPCM

Coriolis Massflowmeter

INSTALLATION AND OPERATION MANUAL

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

FLOW RATE CORRECTION CALCULATOR GDR 1403

Tittel. Cost Efficient Corrosion and Erosion Monitoring for Pipeline Integrity av Navn. Trond Olsen President, ClampOn, Inc.

TMU. Coriolis Mass Flow Meter. for liquids and gas

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

FLOW RATE CORRECTION CALCULATOR GDR 1403

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Target disk flowmeter for liquids and gases

Process Protection Acoustic sensors for pump monitoring

Applications. > > Oil & Gas. > > RoVs and auvs. > > Oceanography. > > Monitoring stations. > > Seismic. > > Networks and relay chains

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Abstract. 1. Introduction

Biofilm Monitoring System. Catalog.

LST100 Ultrasonic level transmitter for upstream oil and gas

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

OPTIFLUX 5000 Technical Datasheet

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

MULTICONT MULTICHANNEL PROCESS CONTROLLER

Remote Radio Control. WAVE Push button radio control systems

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Improve asset protection and utilization

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Corrosion Monitoring system through 'surf-board' communication by satellite. Geir Instanes, Vice President, ClampOn

Coriolis Mass Flow Meter Model TM

DigitalFlow TM CTF878

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

B850 Boiler House Energy Monitor

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Sensorlink Corrosion monitoring on welds. Subsea Controls Down Under ISO 9001:2008 certified IECEx certified

OFFSHORE ENERGY. BUYER S GUIDE HYDROlog Hydrotest Logger Range. Simply advanced

Applications Features

Passive Acoustic Leak Detection

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Subsea Wireless Instrumentation and Communication Systems. Ian Crowther March 2014

Capability Presentation. Enhanced Production optimisation and asset monitoring SUT 2018 November. Kevin Glanville Design & Development Manager

Level gauges Series LT Level indicator, switch and transmitter for liquids

Technical Specification FLUXUS ADM 8127B

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Saab Tank Control representative:

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Remote I/O. 74 Remote I/O. Remote I/O System

UIM-4F. UIM-4F for Custody Transfer Measurement Four Paths for Enhanced Accuracy and Reliability

Level Measurement Continuous level measurement Radar transmitters

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

IP26 Series Current to Pneumatic Converter

Deepwater Precommissioning Services

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

Coriolis Massflowmeter

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

MULTICONT OUR PROFESSION YOUR LEVEL

SONOMETER TM 1100 Ultrasonic compact energy meter

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

Absolute encoders - SSI EX approval ATEX EEx d IIC T6 Optical single and multiturn encoders 14 bit ST / 12 bit MT

E l e c t r o m a g n e t i c f l o w m e t e r s

SONAPHONE-Family PRODUCT OVERVIEW PREVENTIVE MAINTENANCE LEAK DETECTION AND CLASSIFICATION

Enabling Subsea Processing by Connecting Innovation with Experience

TECHNOLOGY LTD. Components, Systems and Service all from one Company. United Kingdom

BATAILG TAIL GAS ANALYZER. Rev. 1.1

Serie NW - Acoustic Wave. Option list. Applications / Overview

USM GT400 Ultrasonic Flowmeter

EverBlu. Wireless fixed data collection system

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

OPTIFLUX 5000 Technical Datasheet

Submersible pressure sensor For water and wastewater Model LW-1

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

- Continuous real-time measurement and PD trend analysis; not multiplexed data collection.

Upgrades of Subsea Infrastructure

mass flowmeter for compressed air

Metal tube variable area flowmeters for gases, liquids and steam

USBL positioning and communication SyStEmS. product information GUidE

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Flow Measurement SITRANS F M

Transcription:

ULTRASONIC INTELLIGENT SENSORS ClampOn DSP Leak Monitor DIGITAL SIGNAL PROCESSING ULTRASONIC INTELLIGENT SENSORS

ClampOn DSP Leak Monitor The ClampOn DSP Leak Monitor detects small and medium leaks or flow-throughs, even with low differential pressure over the measuring point on pipes and valves. The ClampOn DSP Leak Monitor has been developed with the aim of offering a product that can quantify a leak through a closed valve. The ClampOn DSP Leak Monitor is qualified as a subsea and topside monitor. Leaks A leak in an oil or gas flow line is a highly dangerous situation upstream as well as downstream, so it is extremely important for the operator to be warned about any leak immediately should it occur. A leak in a flow line, valve, flange or any other component can compromise safety and may also lead to a shutdown at the production stage or down-stream at a refinery or terminal. A product leak normally has a very low flow-rate, which is determined by the size of the defect, the properties of the fluid and the pressure differential. There are a number of advantages in using the DSP Leak Monitor to monitor valves: - Reduced loss to flare - Gas leak to the sea - Reduced loss to the atmosphere - Reduced process loss - Maintenance planning. The ClampOn DSP Leak Monitor helps operators identify and quantify sources of gas/liquid leakages, thus enabling them to take appropriate action. Customers have successfully used the ClampOn Leak Monitor to identify cross-flow in valves connected to the manifold. Placement of sensor; on the valve itself or as close as possible on the pipe. Principle of operation The basic theory is that a leak creates a very high-frequency noise that can be monitored by an ultrasonic sensor. In a «non-leak» situation the ultrasonic pattern will be stable, but when a leak occurs the signature will change drastically. ClampOn s DSP technology distinguishes and eliminates background noise unrelated to leakages so that the hiss from the leaks can warn the operator. The system also includes a program or database that helps to monitor and indicate the volume of the leak. The ClampOn DSP Leak Monitor is the result of a joint venture project involving several participants in the petroleum industry. The ClampOn DSP Leak Monitor is designed to be installed at critical points such as valves, flanges, joints, etc., and can monitor very small leakages. A pressure differential of as little as 1 bar can be monitored in gases, and 3 bar in liquids. The sensor The ClampOn DSP Leak Monitor, based on our patented Ultrasonic Intelligent Sensor technology, is available in topside and subsea versions. The sensor is a compact and user-friendly unit, more so than other instruments on the market. It is easier to install in the field and easier to transfer to a new location.

The sensor is constructed of stainless steel for topside units and titanium for subsea units, and is clamped to the location (valve, flange or pipe) to be monitored. The topside units are certified to EEx ia IIB, or EEx d IIC, pipe wall temperatures from -40 to +225 o C (437 o F ). An unlimited number of sensors can be connected to a single computer for real-time measurements. The sensors transmit an ASCII signal to the control computer. Data processing The signal from the sensors can be interfaced directly with any type of Main Control System, and can even communicate as a ModBus Slave with any ModBus Master unit. ClampOn Automation Controller Ownership is essential when implementing a monitoring system. At ClampOn we want to ensure that someone knows how your system works and is able to maintain its performance throughout its lifetime. We feel a responsibility not only to keep the equipment running smoothly, but to continue to develop new features that can increase the value of the systems we have delivered. Including a ClampOn controller in your system can help you achieve maximum system performance while keeping commissioning and maintenance costs at a minimum. Tiny and robust, with low power consumption ClampOn programmable automation controllers (PAC) combine the small form factor, reliability and ruggedness of a controller with the flexible and userfriendly client interface known from our software for other platforms. A single controller can handle up to 250 ultrasonic sensors and is simple to control remotely via a network (Network interface with embedded FTP, WEB, Modbus and ClampOn servers). The controller can easily be expanded with hot-swappable IO modules (4-20 ma, relay, CANbus, Profibus etc.); it runs on 24 VDC (6W) and can be mounted on a DIN-rail. The Les stars choisissent toujours les meilleurs instruments. PACs come with sufficient solid-state memory (up to 2GB). However, if longterm data logging is required the controller can be equipped with Compact- Flash, or an external hard drive can be connected to its USB interface. If a dedicated computer is required, ClampOn can supply a PC equipped with our specialised software running under Microsoft Windows. The computer is installed in a safe area and enables the operator to monitor the leak in real time, as well as generating reports from one or more sensors. Field lamp & reset button Topside sensors can be supplied with an indicator lamp that lights up when a leak occurs, as well as a button to reset the sensor. Cabling ClampOn sensors use twisted-pair cabling for power and signal transmission. All cables can be supplied and terminated by ClampOn. ClampOn subsea systems All ClampOn systems incorporate what we call «Passive Ultrasonic Intelligent Sensors». For the user, this simply means that our technology measures, in real time, leakages in a flow line, valve, flange etc. by using acoustics. All ClampOn sensors are «intelligent» (patented), and provide digital or analogue communication with any subsea control system. Two subsea versions are available depending on required water depth. The system consists of the sensor, funnel with clamp and cable with subsea connector.

Product Specifications LEAK MONITOR Principle of operation Passive acoustic, intelligent sensor Minimum detectable leakage Gas: dp>1 bar, min. leakage rate 0.1 l/min Liquid: dp>3 bar, min. leakage rate 0.1 l/min (depending on delta pressure [dp] over the leakage point) Repeatability 1% Method of installation Clamped to pipe surface, non-intrusive Sensor electronics Intelligent DSP electronics with signal processing Interface options All sensors can be supplied with: Digital RS485 (ASCII, binary, ModBus RTU), 4-20mA (active/passive), Relay (Other options on request). Options for ATEX approved sensors local light/reset Options for subsea sensors CANBus, Profibus Two-way communication Yes Software upgrading Yes Pipe Surface Temperature -40 to 225 ºC (-40 to 437 ºF) High temperature fixture Yes up to 500 ºC Flow regimes Oil, gas, water, multiphase TOPSIDE ATEX II 1G EEx ia IIB T2-T5, Zone 0 II 2G EEx de/dem IIC T5, Zone 1 CSA C&US Ex ia IIB T5, Class I Division 1 Group C, D, Zone 0 GOST-R / GGTN 2 Ex de IIC T5, Zone 1 INMETRO BR-Ex ia IIB T2-T5, Zone 0 BR-Ex de/dem IIC T5, Zone 1 Ingress protection IP68 Housing material 316 Stainless Steel Dimensions / Weight Ex ia Model: ø80 x 105mm (ø3.1 x 4.1 ) / 2.6 kg (5.7 lbs) Ex d Model: ø101 x 211mm (ø4.1 x 8.7 ) / 7.2 kg (15.9 lbs) Cable interface Cable with connector / Flying lead / Gland for cable access Power / Safety Barriers Ex ia: ClampOn IS power barrier, IS approved signal barriers Ex de/dem: Power 12-36VDC. No IS barriers for signal or power Power Consumption Typical 1,5 Watt, max. 2 Watt per sensor Cabling Minimum 4x 0.75 mm2 (pending system configuration) Safe Area Equipment Portable / fixed (19 ) power module with IS barriers Mains power supply 12 VDC / 24 VDC / 100-240 VAC 50-60 Hz Computer for ClampOn software Minimum requirements: Pentium III, 512 MB RAM. Windows XP/Vista/2000-2008 Signal interface to Client system (typical) RS232 / RS485 / Relay / ModBus / TCP I/P Optional 4-20mA / Relay SUBSEA COMPACT DEEPWATER Water depth 3000m 4500m Design pressure bara 333 (4830 psi) 675 (9790 psi) Housing material Titanium Titanium Dimensions excl. ROV handle ø90 x 325mm (ø3.5 x 12.8 ) ø150 x 360mm (ø5.9 x 14.2 ) Dry weight, kg (lbs) 5.2 (11.5) 18 (39.7) Pipe Surface Temperature -40 to 225 ºC (-40 to 437 ºF) -40 to 225 ºC (-40 to 437 ºF) Hose/jumper interface Bennex / ODI / Tronic Bennex / ODI / Tronic Redundant electronics Yes Yes ROV installation/retrieval Yes Yes Retrofit clamp/funnel Yes No Power Supply 12-28VDC 12-28VDC Current draw Approx. 60mA @ 24VDC Approx. 70mA @ 24VDC Design Lifetime (MTBF) 220 000 hours (25 years) 220 000 hours

Subsea Basket with battery and data logger. Custom solutions For many years, ClampOn s highly skilled engineering department has been developing and building custom subsea systems that have since become part of our standard product range. ROV operable retrofit solution for large pipe dimensions. ClampOn Ultrasonic Intelligent Sensor Non-intrusive Digital Signal Processing (DSP) Complete digitalisation No analogue filters, circuits or ampli fiers Two-way communication Real-time measurement Easy to relocate Contains no moving parts Can be mounted in hostile environments Incorporates sensitive, intelligent, intrinsically safe sensors Can be upgraded by software download Can store up to 60 days of measurement data within the sensor itself Self-testing capabilities Built-in temperature sensor and accelerometer (optional) User-friendly software for Windows 2000/2003/XP/NT4 Since 1995, ClampOn has supplied thousands of «Ultrasonic Intelligent Sensors» to oil and gas companies all over the world, which have benefited from the use of our systems and found them extremely satisfactory. Our systems are preferred to the alternatives because of their repeatability, accuracy and robustness, and our company's expertise in this field. Continuous technology development and personnel training have made ClampOn the winner of all field and laboratory tests in which we have participated, a position we are determined to maintain in the future. The latest developments offer operators a future-oriented solution, in which the system can be upgraded simply by downloading new software.

ClampOn - the leader in sand, pig and corrosion-erosion monitoring ClampOn has since the beginning in 1995 grown to be the largest supplier of passive ultrasonic systems for sand/particle monitoring to the international oil and gas sector. All products supplied by ClampOn, particle monitor, pig detector, corrosion-erosion monitor and leak monitor are based on the same, well proven technology platform. Both the topside and the subsea instruments incorporate Digital Signal Processing (DSP), complete digitalization eliminating analogue filters, circuits and amplifiers. The ClampOn Ultrasonic Intelligent Sensor processes all data in the sensor itself (patented principle), thus enabling the instrument to discriminate between sandgenerated and flow-generated noise. This is of importance to the user since changes in flow rates and the gas/oil ratio will not affect the performance of the system. A good signal to noise (s/n) ratio is vital for quality measurements of this sort, and ClampOn s sensors are the very best in this respect. With the new version, the external noise has been completely eliminated. Subsea Sensors The subsea sensors were developed in close collaboration with Shell Deepwater Development Inc. in Houston and FMC Energy Systems in Norway. The successful outcome of the project was a sand monitoring system that combined an extremely long working life with excellent acoustic properties, offering reliability in the high pressure deepwater environment. ClampOn has since 1998 supplied approximately 1000 subsea sensors to the oil and gas industry. The subsea monitors have been under a continuous development in order to optimize quality and performance, and to meet the requirements in the market. ClampOn DSP Corrosion- Erosion Monitor (CEM) The CEM is monitoring any changes in wall thickness. Two to eight transducers are mounted on the pipe surface (or other metal plate structure) and connected to a ClampOn control unit. The control unit will continuously send and receive guided waves between the transducers, resulting in a network of measurement paths that cover the selected area. The working principle of the instrument is based on transmitting ultrasonic signals CAPTEURS INTELLIGENTS À ULTRASONS that propagate through the pipe material. The transmitted signal is received by a sensor and is analyzed using advanced data processing schemes. ClampOn SandQ & ClampOn DSP-06 Particle Monitor All sensors are exactly alike and interchangeable, an advantage if sensors should be moved/relocated or in case of service. The DSP s increase in processing capacity enables the sensor to combine signals from several frequency ranges when analysing the flow. The ClampOn sensors are versatile, and are the only instruments on the market offering two-way communication between sensor and control system. This solution enables future upgrade of the sensor via a simple download of new software. When using digital output from the sensors, they can be installed in a «multi-drop» system. NORVÈGE : ClampOn AS, Vaagsgaten 10, NO-5160 Laksevaag Bergen Norvège Tél. : +47 5594 8850 Télécopieur : +47 5594 8855 Courriel : mail@clampon.com ÉTATS-UNIS : ClampOn, Inc., 15720 Park Row, Ste. 300 (77084) - PO Box 219206 (77218-9206) Houston TX - États-Unis, Tél. : +1 281 492 9805 Télécopieur : +1 281 492 9810 - Courriel : info@clamponinc.com Site Internet : www.clampon.com Design: Cucumber /Tønnes H. Gundersen Photo: Thor Westrebø Imprimeur: Molvik Grafisk AS MAY 2011