KNX TH65-AP. Thermo-Hygrometer. Installation and Adjustment. Item number 70184

Similar documents
Air Quality Sensor KNX AQS

KNX RW. Rain / Wind Sensor. Installation and Adjustment. KNX RW 24 V No KNX RW 230 V No

Suntracer KNX basic. Weather Station. Installation and Adjustment. Suntracer KNX basic 24 V. Suntracer KNX basic 230 V

KNX LW. Brightness / Wind Sensor. Installation and Adjustment. KNX LW 24 V No KNX LW 230 V No

KNX PY. Global Irradiance Sensor. Installation and Adjustment

Weather Station for KNX

KNX S-UP. Actuator for 230 V or 24 V. Installation and Adjustment

Suntracer KNX-GPS. Weather Station. Installation and Adjustment. Item number 3093

Fan Coil Actuator FCA 2

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual

Technical manual GS 4x.00 knx application description air quality sensor

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

Arcus-EDS. Application Description. SK0x-Txxx

Technical Manual MDT Room Temperature Controller

Technical Manual MDT Air quality/co2 Sensor

Room thermostat solo, FM Type: 6124-xx

KNX Room temperature controller

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Application Programs Descriptions

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

EIB/KNX, Indoor / Outdoor, IP65 Document: 3400_ex_SK08-GLBS.pdf Article No.

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

NRT 105: Electronic fan-coil controller, equiflex

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

CU-DIN DIM 6-CH 0 10V KNX

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

EIB/KNX, Indoor / Outdoor, IP65 Document: 3600_ex_SK08-BFTLFT.pdf Article No. 6.1 Application Description Product Page 20

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

Radio System Strobe Wizard Plus Freemask

Mx-RPW Room Control Module (Built-In Occupancy Sensor)

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

» Minimal and maximal levels can be set on site. The bus coupling unit enables to use the values in the KNX-Bus.

Room Temperature Controllers. for heating and cooling systems

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

EIB/KNX Switch Actuators. User manual

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

NLG513 SOFTWARE. Translation of the original German operating instructions

Astra-R Kit Wireless Alarm System Operation Manual

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

K-BUS Switch Actuator

EIB/KNX, Indoor / Outdoor, IP65 Document: 3500_ex_SK08-BFT.pdf Article No.

USER MANUAL CU-DIN DIM 4-CH 1.5A KNX EC MA

PU202 Level converter & encoder signal generator without potential separation

Room Temperature Controllers. for heating and cooling systems

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

QFM21... Duct sensors. Symaro. for relative humidity and temperature

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

ABB i-bus. KNX Weather Station WS/S Product Manual

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

KNX manual 1-channel flush-mounted switch actuator SU 1

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

Unidirectional Gateway EnOcean - KNX/BUS

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Instabus Radio Control Converter Installation Instructions

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

S5-ADU. Front... 4 Rear... 4

MDT Switch Actuator/FanCoil

Operating instruction

Electronic Controls For general purpose and multi stages controls. Features and Benefits

KNX ENO 634 (32-channel AP)

Power supply CP-D 12/2.1

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

Installation and Operating Instructions

TLC3-BCR-U Series Thermostat

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

Please completely read through operating instructions! Do not discard! The warranty shall be invalidated by damage caused by operating errors!

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

SUNSTAR 传感与控制

Operating Instructions. EnOcean radio wall transmitter

Brief description. Type overview

Operating Instructions for Microwave Level Switch. Model: LNM

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

KNX ENO 620/622 (32-channel AP)

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

Precipitation Monitor ,

LK Wireless Room Control Cq

Awning control system GFM001. Installation and Operating Instructions

Communicative heating controller

MP Series Radar Transmitter Installation & Operation Manual

Magnetic Inductive Flow Sensor induq

Instruction manual. art Installation manual

Transcription:

EN KNX TH65-AP Thermo-Hygrometer Item number 70184 Installation and Adjustment

1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes... 4 2.2. Location... 5 2.3. Mounting and connection... 6 2.3.1. Layout of casing and pcb... 6 2.3.2. Connection of the sensor... 6 2.4. Notes on mounting and commissioning... 6 3. Maintenance... 7 4. Transmission protocol... 8 4.1. List of all communication objects... 8 4.2. General settings... 13 4.3. Temperature measured value... 14 4.4. Temperature threshold values... 15 4.5. Temperature threshold value 1/2/3/4... 16 4.6. Temperature PI control... 19 4.7. Humidity measured value... 26 4.8. Humidity threshold value... 27 4.8.1. Humidity threshold value 1/2... 28 4.9. Humidity PI control... 31 4.10.Dew point temperature... 34 4.10.1. Cooling medium temperature sensor... 34 4.11.Absolute humidity... 37 4.12.Comfort field... 38 4.13.Logic... 39 4.13.1. AND Logic 1/2/3/4... 40 4.13.2. Linkage inputs of AND logic... 40 4.13.3. OR Logic 1/2/3/4... 41 4.13.4. Linkage inputs of OR Logic... 42 Elsner Elektronik GmbH Herdweg 7 D-75391 Gechingen Germany Thermo-Hygrometer KNX TH65-AP from software version 0.2.0, ETS programme version 2.0 Status: 10.12.2013 Subject to technical changes. Errors excepted.

2 Clarification of signs Installation, inspection, commissioning and troubleshooting of the device must only be carried out by a competent electrician. This manual is amended periodically and will be brought into line with new software releases. The change status (software version and date) can be found in the contents footer. If you have a device with a later software version, please check www.elsner-elektronik.de in the menu area "Service" to find out whether a more up-todate version of the manual is available. Clarification of signs used in this manual Safety advice. DANGER! WARNING! CAUTION! Safety advice for working on electrical connections, components, etc.... indicates an immediately hazardous situation which will lead to death or severe injuries if it is not avoided.... indicates a potentially hazardous situation which may lead to death or severe injuries if it is not avoided.... indicates a potentially hazardous situation which may lead to trivial or minor injuries if it is not avoided. ATTENTION!... indicates a situation which may lead to damage to property if it is not avoided.

3 Description 1. Description The Temperature and Humidity Sensor KNX TH65-AP measures temperature and humidity in indoor and outdoor areas and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to an overall temperature and overall air humidity (mixed values). The KNX TH65-AP provides seven switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling (depending on temperature) and for ventilation (depending on air humidity) and it can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left. Functions: Measurement of temperature and air humidity (relative and absolute), calculation of dew point Mixed values from own measured values and external values (proportions can be set in percentage) PI controller for heating (one or two step) and cooling (one or two step) depending on temperature PI controller for ventilation depending on humidity: Dehumidify/humidify (one step) or dehumidify (one or two step) 7 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects) 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs in the form of communication objects may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits Configuration is made using the KNX software ETS. The product file, the data sheet and the manual can be downloaded from the Elsner Elektronik homepage on www.elsner-elektronik.de in the Service menu. 1.1. Technical specifications Housing Plastic material, sensor sleeve metal Colour Grey Mounting On-wall Protection category IP 65 Dimensions approx. 65 91 38 (W H D, mm) Weight approx. 80 g Ambient temperature Operation -30 +85 C, Storage -55 +125 C Operating voltage KNX bus voltage Bus current max. 5,5 ma, max. 9 ma when programming LED is active Data output KNX +/- bus terminal plug BCU type Own micro controller Thermo-Hygrometer KNX TH65-AP Status: 10.12.2013 Technical changes reserved. Errors reserved.

4 Installation and commissioning PEI type 0 Group addresses max. 184 Allocations max. 184 Communication objects 110 Measurement range -40...+80 C temperature Resolution (temperature) 0,1 C Accuracy (temperature) ±1 C at -10...+85 C ±1,5 C at -25...+150 C Measurement range 0...100% humidity Resolution (humidity) 0,1% Accuracy (humidity) 0...20% = ±5%R. H. 20...80% = ±3%R. H. 80...100% = ±5%R. H. Drift (humidity) ±0,5%R. H. per year in normal air The product conforms with the provisions of EC guidelines EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC The following standards and/or technical specifications have been applied: EN 50491-5-1: 2010 EN 50491-5-2: 2011 EN 60730-1: 2011 2. Installation and commissioning 2.1. Installation notes Installation, testing, operational start-up and troubleshooting should only be performed by an electrician. CAUTION! Live voltage! There are unprotected live components inside the device. National legal regulations are to be followed. Ensure that all lines to be assembled are free of voltage and take precautions against accidental switching on. Do not use the device if it is damaged. Take the device or system out of service and secure it against unintentional use, if it can be assumed, that risk-free operation is no longer guaranteed. Thermo-Hygrometer KNX TH65-AP Status: 10.12.2013 Technical changes reserved. Errors reserved.

5 Installation and commissioning The device is only to be used for its intended purpose. Any improper modification or failure to follow the operating instructions voids any and all warranty and guarantee claims. After unpacking the device, check it immediately for possible mechanical damage. If it has been damaged in transport, inform the supplier immediately. The device may only be used as a fixed-site installation; that means only when assembled and after conclusion of all installation and operational start-up tasks and only in the surroundings designated for it. Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions. 2.2. Location The sensor is designed for surface mounting. When selecting an installation location, please ensure that the measurement results are affected as little as possible by external influences. Possible sources of interference include: Direct sunlight Drafts from windows and doors Warming or cooling of the building structure on which the sensor is mounted, e.g. due to sunlight, heating or cold water pipes Connection lines which lead from warmer or colder areas to the sensor Temperature variations from such sources of interference must be corrected in the ETS in order to ensure the specified accuracy of the sensor (temperature offset). For outdoor installation it must be ensured that a 60 cm gap is left below the sensor in order to prevent it from being snowed during snowfall. The sensor must be mounted vertically. The measurement probe and the cable outlet must point downwards. Thermo-Hygrometer KNX TH65-AP Status: 10.12.2013 Technical changes reserved. Errors reserved.

6 Installation and commissioning 2.3. Mounting and connection 2.3.1. Layout of casing and pcb 1 2 3 4 5 Fig. 1 Opened casing, board 1 KNX terminal +/- 2 Programming button for teaching the device 3 Programming LED 4 Cable entry with threaded joint 5 Sensor tip Fig. 2 Rear view with dimensioning of openings for mounting 2.3.2. Connection of the sensor Remove the screwed on cover. Lead the KNX bus connection cable through the cable entry on the bottom of the casing and connect the bus +/- to the terminal provided for this purpose. Screw the cover back on. 2.4. Notes on mounting and commissioning Do not open the temperature sensor if penetration of water (rain) is likely: Only a couple of drops could damage the electronic. Do not dip the measuring tip (metal sleeve with sensor) in water, as this will distort the measuring results until the humidity sensor is completely dry again. After the bus voltage has been applied, the device will enter an initialisation phase lasting a few seconds. During this phase no information can be received via the bus. Thermo-Hygrometer KNX TH65-AP Status: 10.12.2013 Technical changes reserved. Errors reserved.

7 Maintenance 3. Maintenance Always isolate the device from the voltage supply for servicing and cleaning. The device must regularly be checked for dirt twice a year and cleaned if necessary. In case of severe dirt, the sensor may not work properly anymore. ATTENTION The device can be damaged if significant volumes of water penetrate the housing. Do not clean with high pressure cleaners or steam jets. Thermo-Hygrometer KNX TH65-AP Status: 10.12.2013 Technical changes reserved. Errors reserved.

8 Transmission protocol 4. Transmission protocol 4.1. List of all communication objects Abbreviations flags: C Communication R Read W Write T Transmit U Update No. Name Function DPT Flags 0 External measured value for Input 9.001 C W temperature 1 Internal measured value for Output 9.001 C R T temperature 2 Total measured value for Output 9.001 C R T temperature 3 Request min./max. measured value Input 1.017 C W for temperature 4 Minimum measured value for Output 9.001 C R T temperature 5 Maximum measured value for Output 9.001 C R T temperature 6 Reset min./max. measured value for Input 1.017 C W temperature 7 Temperature sensor malfunction Output 1.001 C R T 9 Temp. threshold value 1: Input / Output 9.001 C R W T U Absolute value 10 Temp. threshold value 1: (1:+ 0:-) Input 1.006 C W 11 Temp. threshold value 1: Output 1.001 C R T Switching output 12 Temp. threshold value 1: Input 1.006 C W Switching output block 13 Temp. threshold value 2: Input / Output 9.001 C R W T U Absolute value 14 Temp. threshold value 2: (1:+ 0:-) Input 1.006 C W 15 Temp. threshold value 2: Output 1.001 C R T Switching output 16 Temp. threshold value 2: Switching output block Input 1.006 C W

9 Transmission protocol No. Name Function DPT Flags 17 Temp. threshold value 3: Input / Output 9.001 C R W T U Absolute value 18 Temp. threshold value 3: (1:+ 0:-) Input 1.006 C W 19 Temp. threshold value 3: Output 1.001 C R T Switching output 20 Temp. threshold value 3: Input 1.006 C W Switching output block 21 Temp. threshold value 4: Input / Output 9.001 C R W T U Absolute value 22 Temp. threshold value 4: (1:+ 0:-) Input 1.006 C W 23 Temp. threshold value 4: Output 1.001 C R T Switching output 24 Temp. threshold value 4: Switching output block Input 1.006 C W 25 Temp. control: Switching object Input 1.002 C W (0:heating 1:cooling) 26 Temp. control: Target value current Output 9.001 C R T 27 Temp. control: Blocking object Input 1.006 C R W 28 Temp. control: Target value, Input / Output 9.001 C R W T U day heating 29 Temp. control: Target value, Input 1.002 C W day heating (1:+ 0:-) 30 Temp. control: Target value, Input / Output 9.001 C R W T U day cooling 31 Temp. control: Target value, Input 1.002 C W day cooling (1:+ 0:-) 32 Temp. control: Act. variable heating Output 5.001 C R T 1. stage 33 Temp. control: Act. variable heating Output 5.001 C R T 2. stage 34 Temp. control: Act. variable heating 2. stage Output 1.001 C R T 35 Temp. control: Act. variable cooling 1. stage 36 Temp. control: Act. variable cooling 2. stage 37 Temp. control: Act. variable cooling 2. stage 38 Temp. control: Night lowering activation 39 Temp. control: Target value heating, night Output 5.001 C R T Output 5.001 C R T Output 1.001 C R T Input 1.003 C W Input / Output 9.001 C R W T U

10 Transmission protocol No. Name Function DPT Flags 40 Temp. control: TargetV heating, night (1:+ 0:-) 41 Temp. control: Target value cooling, night 42 Temp. control: TargetV cooling, night (1:+ 0:-) 43 Temp. control: Status heating 1 (1=ON 0=OFF) 44 Temp. control: Status heating 2 (1=ON 0=OFF) 45 Temp. control: Status cooling 1 (1=ON 0=OFF) 46 Temp. control: Status cooling 2 (1=ON 0=OFF) 47 Temp. control: Window status (0: closed 1: open) Input 1.002 C W Input / Output 9.001 C R W T U Input 1.002 C W Output 1.001 C R T Output 1.001 C R T Output 1.001 C R T Output 1.001 C R T Input 1.019 C W 48 External measured value for Input 9.007 C W humidity 49 Internal measured value for Output 9.007 C R T humidity 50 Total measured value for humidity Output 9.007 C R T 51 Request min./max. measured value Input 1.017 C W for humidity 52 Minimum measured value for Output 9.007 C R T humidity 53 Maximum measured value for Output 9.007 C R T humidity 54 Reset min./max. measured value for humidity Input 1.017 C W 55 Humidity threshold value 1: Absolute value 56 Humidity threshold value 1: (1:+ 0:-) Input / Output 9.007 C R W T U Input 1.006 C W 57 Humidity threshold value 1: Switching output 58 Humidity threshold value 1: Switching output block 59 Humidity threshold value 2: Absolute value 60 Humidity threshold value 2: (1:+ 0:-) Output 1.001 C R T Input 1.006 C W Input / Output 9.007 C R W T U Input 1.006 C W

11 Transmission protocol No. Name Function DPT Flags 61 Humidity threshold value 2: Switching output 62 Humidity threshold value 2: Switching output block Output 1.001 C R T Input 1.006 C W 63 Humidity control: Blocking object Input 1.006 C W 64 Humidity control: Target value Input / Output 9.007 C R W T U 65 Humidity control: Target value Input 1.006 C W (1:+ 0:-) 66 Humidity control: Act. variable Output 5.001 C R T dehumidification 1. stage 67 Humidity control: Act. variable Output 5.001 C R T dehumidification 2. stage 68 Humidity control: Act. variable humidification Output 5.001 C R T 69 Dew point temperature Output 9.001 C R T 70 Cooling medium temp.: Output 9.001 C R W T U Threshold value 71 Cooling medium temp.: Input 9.001 C W Actual value 72 Cooling medium temp.: Input 1.006 C W Offset change (1:+ 0:-) 73 Cooling medium temp.: Output 1.001 C R T Switching output 74 Cooling medium temp.: Switching output block Input 1.006 C W 75 Absolute humidity [g/kg] Output 14.005 C R T 76 Absolute humidity [g/m³] Output 14.005 C R T 77 Ambient climate: 1=comfortable 0=uncomfortable Output 1.006 C R T 78 Logic input 1 Input 1.006 C W 79 Logic input 2 Input 1.006 C W 80 Logic input 3 Input 1.006 C W 81 Logic input 4 Input 1.006 C W 82 Logic input 5 Input 1.006 C W 83 Logic input 6 Input 1.006 C W 84 Logic input 7 Input 1.006 C W 85 Logic input 8 Input 1.006 C W

12 Transmission protocol No. Name Function DPT Flags 86 AND logic 1: 1 bit Output 1.001 C R T 87 AND logic 1: 8 bit output A Output 5.010 C R T 88 AND logic 1: 8 bit output B Output 5.010 C R T 89 AND logic 2: 1 bit Output 1.001 C R T 90 AND logic 2: 8 bit output A Output 5.010 C R T 91 AND logic 2: 8 bit output B Output 5.010 C R T 92 AND logic 3: 1 bit Output 1.001 C R T 93 AND logic 3: 8 bit output A Output 5.010 C R T 94 AND logic 3: 8 bit output B Output 5.010 C R T 95 AND logic 4: 1 bit Output 1.001 C R T 96 AND logic 4: 8 bit output A Output 5.010 C R T 97 AND logic 4: 8 bit output B Output 5.010 C R T 98 OR logic 1: 1 bit Output 1.001 C R T 99 OR logic 1: 8 bit output A Output 5.010 C R T 100 OR logic 1: 8 bit output B Output 5.010 C R T 101 OR logic 2: 1 bit Output 1.001 C R T 102 OR logic 2: 8 bit output A Output 5.010 C R T 103 OR logic 2: 8 bit output B Output 5.010 C R T 104 OR logic 3: 1 bit Output 1.001 C R T 105 OR logic 3: 8 bit output A Output 5.010 C R T 106 OR logic 3: 8 bit output B Output 5.010 C R T 107 OR logic 4: 1 bit Output 1.001 C R T 108 OR logic 4: 8 bit output A Output 5.010 C R T 109 OR logic 4: 8 bit output B Output 5.010 C R T 110 Software version Output 217.001 C R T

13 Transmission protocol 5. Setting of parameters 5.1. General settings Transmission delays after power-up and programming for: Measured values 5 s 10 s 30 s 1 min 2 h Threshold values and switching outputs 5 s 10 s 30 s 1 min 2 h Target values and actuating variables 5 s 10 s 30 s 1 min 2 h Logic outputs 5 s 10 s 30 s 1 min 2 h Maximum telegram quota Use malfunction object 1 2 3 5 10 20 telegrams per second No Yes

14 Transmission protocol 5.2. Temperature measured value Temperature offset in 0,1 C -50...50 Use external measured value for temperature If no external measured value is used No Yes Use external measured value for temperature Temperature measured value From change of (only if sending in case of change ) Send periodically all (only if sending periodically ) Use min. and max. temperature values (Values are not maintained after reset) No do not send send periodically send in case of change send in case of change and periodically 2% 5% 10% 25% 50% 5 s 10 s 30 s 1 min 2 h No Yes If an external measured value is used Use external measured value for temperature Ext. temperature measured value proportion of the total measured value Yes 5% 100% (in steps of 5%)

15 Transmission protocol Internal and total measured value for temperature do not send send periodically send in case of change send in case of change and periodically All following settings refer to the total measured value From change of 2% 5% 10% 25% 50% (only if sending in case of change ) Send periodically all (only if sending periodically ) Use min. and max. temperature values (Values are not maintained after reset) 5 s 10 s 30 s 1 min 2 h No Yes 5.3. Temperature threshold values Use temperature threshold value 1/2/3/4 No Yes

16 Transmission protocol 5.4. Temperature threshold value 1/2/3/4 Temperature threshold values Use temperature threshold value 1/2/3/4 Parameter Communication object If the threshold value is set per Parameter: Temperature threshold value standard per Parameter Temperature threshold value in 0,1 C -300...800 Hysteresis of the threshold value in % 0...50

17 Transmission protocol If the threshold value is set per Communication object: Temperature threshold value standard per The value communicated last shall be maintained Start temperature threshold value in 0,1 C valid until 1. communication (only if the value communicated last is not maintained or after restoration of voltage ) Type of threshold change for temperature Step size (only with Increment/decrement ) Temperature switching output Communication object not after restoration of voltage after restoration of voltage and programming (Do not use for first commissioning) -300 800 Hysteresis of the threshold value in % 0 50 Absolute value Increment/decrement 0,1 C 0,2 C 0,3 C 0,4 C 0,5 C 1 C 2 C 3 C 4 C 5 C Output is at (TV = temperature threshold value) Switching delay from 0 to 1 Switching delay from 1 to 0 Temperature switching output sends Send temperature switching output (only if sending periodically ) TV above = 1 TV Hyst. below = 0 TV above = 0 TV Hyst. below = 1 TV below = 1 TV + Hyst. above = 0 TV below = 0 TV + Hyst. above = 1 none 1 s 2 s 5 s 10 s 2 h none 1 s 2 s 5 s 10 s 2 h on change on change to 1 on change to 0 on change and periodically on change to 1 and periodically on change to 0 and periodically 5 s 10 s 30 s 1 min 2 h Blocking Use block of the temperature switching output Evaluation of the temperature blocking object Value of the blocking object before 1. communication No Yes if value 1: block if value 0: release if value 0: block if value 1: release 0 1

18 Transmission protocol Behaviour of switching output with blocking do not send telegram send 0 send 1 The behaviour with release of the switching output depends on the value of the parameter Temperature switching output sends... (see Temperature switching output ) Value of parameter Temperature switching output sends : on change on change to 1 on change to 0 on change and periodically Setting options Behaviour of switching output with release : do not send telegram send status of the switching output do not send telegram if switching output = 1 send 1 do not send telegram if switching output = 0 send 0 send status of the switching output (no selection) on change to 1 and periodically if switching output = 1 send 1 (no selection) on change to 0 and periodically if switching output = 0 send 0 (no selection)

19 Transmission protocol 5.5. Temperature PI control Use control No Yes If the control is in use Use control Yes Control general Type of control One-stage heating Two-stage heating One-stage cooling One-stage heating + one-stage cooling Two-stage heating + One-stage cooling Two-stage heating + two-stage cooling Behaviour of the blocking object with value 1 = block control 0 = release control 0 = block control 1 = release control Value of the blocking object 0 1 before 1. communication

20 Transmission protocol Send actuating variables Transmission cycle (only if sending periodically ) Status object/s send Transmission cycle (only if sending periodically ) on change on change and periodically 5 s 2 h on change on change to 1 on change to 0 on change and periodically on change to 1 and periodically on change to 0 and periodically 5 s 2 h Controler target value Target value setpoint per Parameter Communication object

21 Transmission protocol If the target value is set per Parameter: Target value setpoint per Parameter Target value in 0,1 C -300 800 If the target value is set per Communication object: Target value setpoint per The value communicated last shall be maintained Start target value in 0,1 C valid until 1. communication (only if the value communicated last is not maintained or after restoration of voltage ) Communication object not after restoration of voltage after restoration of voltage and programming (Do not use for first commissioning) -300 800 Limitation of object value (min) in 0,1 C -300 800 Limitation of object value (max) in 0,1 C -300 800 Type of the target value change Step size (only with Increment/decrement ) Absolute value Increment/decrement 0,1 C 0,2 C 0,3 C 0,4 C 0,5 C 1 C 2 C 3 C 4 C 5 C Heating control/heating control 1. stage (Appears only if heating control is used) Setting of the controller by Application (only if controller is set by preset applications ) Maximum actuating variable is reached at target/actual difference of (Attention: Can only be adjusted if Setting of the controller by controller parameter ) Re-setting time in mins (Attention: Can only be adjusted if Setting of the controller by controller parameter ) If blocked, the actuating variable shall Value in % (not if a specific value is sent) preset applications controller parameter Hot water heating Floor heating Fan convector Electrical heating 1 C 2 C 3 C 4 C 5 C 1 255 will not be sent send a specific value 0 100 With release, the actuating variable follows the control

22 Transmission protocol Presetting for preset applications : Application Maximum actuating variable is reached at target/actual difference of Re-setting time Hot water heating 5 C 150 min Floor heating 5 C 240 min Fan convector 4 C 90 min Electrical heating 4 C 100 min Heating control 2. stage (Appears only if two-stage heating control is used) Target value difference between 1. and 2. stage in 0,1 C Type of control of the 2. stage 0...100 2-point-control PI control If the 2. stage is controlled with 2-point-control: Hysteresis in 0,1 C 0 100 Actuating variable is a 1 bit object 8 bit object Value in % 0 100 (only if actuating variable is an 8 bit object) If blocked, the actuating variable shall Value in % (only if a specific value is sent) If the 2. stage is controlled with PI control: Setting options see heating control 1. stage. not be sent send a specific value 0 100 With release, the actuating variable follows the control Cooling control/cooling control 1. stage (Appears only if cooling control is used) Setting of the controller by Application (only if controller is set by preset applications ) Maximum actuating variable is reached at target/actual difference of (Attention: Can only be adjusted if Setting of the controller by controller parameter ) preset applications controller parameter Cooling ceiling 1 C 2 C 3 C 4 C 5 C

23 Transmission protocol Re-setting in mins (Attention: Can only be adjusted if Setting of the controller by controller parameter ) If blocked, the actuating variable shall Value in % (only if a specific value is sent) 1 255 not be sent send a specific value 0 100 With release, the actuating variable follows the control Presetting for preset applications : Application Maximum actuating variable is reached at target/actual difference of Re-setting ime Cooling ceiling 5 C 240 min Cooling control 2. stage (Appears only if two-stage cooling control is used) Target value difference between 1. and 2. stage in 0,1 C Type of control of the 2. stage 0 100 2-point-control PI control If the 2. stage is controlled with 2-point-control: Hysteresis in 0,1 C 0 100 Actuating variable is a 1 bit object 8 bit object Value in % 0 100 (only if actuating variable is an 8 bit object) If blocked, the actuating variable shall Value in % (only if a specific value is sent) not be sent send a specific value 0 100 With release, the actuating variable follows the control

24 Transmission protocol If the 2. stage is controlled with PI control: Setting options see cooling control 1. stage. Night reduction Use night reduction No Yes If night reduction is used: Use night reduction Night reduction for object value Value of the activation object before 1. communication Target value setpoint per Yes 1 = active 0 = not active 0 = active 1 = not active 0 1 Parameter Communication object If the target value is set per Parameter: Target value setpoint per Target value heating in 0,1 C (if the heating control is used) Target value cooling in 0,1 C (if the cooling control is used) Parameter -300 800-300 800

25 Transmission protocol If the target value is set per Communication object: Target value setpoint per The value communicated last shall be maintained Start target value heating in 0,1 C valid until 1. communication (if the heating control is used and only if the value communicated last is not maintained or after restoration of voltage ) Communication object not after restoration of voltage after restoration of voltage and programming (Do not use for first commissioning) -300 800 Limitation of object value H(min) in 0,1 C -300 800 Limitation of object value H(max) in 0,1 C -300 800 Start target value cooling in 0,1 C valid until 1. communication (if the cooling control is used and only if the value communicated last is not maintained or after restoration of voltage ) -300 800 Limitation of object value C(min) in 0,1 C -300 800 Limitation of object value C(max) in 0,1 C -300 800 Type of the target value change Step size (only with Increment/decrement ) Absolute value Increment/decrement 0,1 C 0,2 C 0,3 C 0,4 C 0,5 C 1 C 2 C 3 C 4 C 5 C Frost/heat protection Use frost/heat protection No Yes If frost/heat protection is used: Use frost/heat protection Target value heating in 0,1 C (only if heating control is used) Delay of activation (after opening window) Target value cooling in 0,1 C (only if cooling control is used) Delay of activation (after opening window) Status of window before 1. communication Yes -300 800 none 1 s 2 h -300 800 none 1 s 2 h CLOSED OPENED

26 Transmission protocol 5.6. Humidity measured value Humidity offset in % RH -10 10 Use external measured value for humidity No Yes If no external measured value is used: Use external measured value for humidity Humidity measured value From change of (only if sending in case of change ) Send periodically all (only if sending periodically ) Use min. and max. humidity values (Values are not maintained after reset) No do not send send periodically send in case of change send in case of change and periodically 2% 5% 10% 25% 50% 5 s 10 s 30 s 1 min 2 h No Yes If an external measured value is used: Use external measured value for humidity Ext. humidity measured value proprotion of the total measured value Yes 5% 100% (in steps of 5%)

27 Transmission protocol Internal and total measured value for humidity 5.7. Humidity threshold value do not send send periodically send in case of change send in case of change and periodically All following settings refer to the total measured value for humidity From change of 2% 5% 10% 25% 50% (only if sending in case of change ) Send periodically all (only if sending periodically ) Use min. and max. humidity values (Values are not maintained after reset) 5 s 10 s 30 s 1 min 2 h No Yes Use humidity threshold value 1/2 No Yes

28 Transmission protocol 5.7.1. Humidity threshold value 1/2 Humidity threshold value: Humidity threshold value setpoint per Parameter Communication object If the threshold value is set per Parameter: Humidity threshold value setpoint per Parameter Humidity threshold value in %RH 0 100 Hysteresis of the threshold value in % 0 50

29 Transmission protocol If the threshold value is set per Communication object: Humidity threshold value setpoint per The value communicated last shall be maintained Start humidity threshold value in %RH valid until 1. communication (only if the value communicated last is not maintained or after restoration of voltage ) Type of threshold change for humidity Step size (only with Increment/decrement ) Humidity switching output Communication object not after restoration of voltage after restoration of voltage and programming (Do not use for first commissioning) 0 100 Hysteresis of the threshold value in % 0 50 Absolute value Increment/decrement 1% 2% 5% 10% Output is at (TV = humidity threshold value) Switching delay from 0 to 1 Switching delay from 1 to 0 Humidity switching output sends Send humidity switching output in the cycle of (only if sending periodically ) TV above = 1 TV Hyst. below = 0 TV above = 0 TV Hyst. below = 1 TV below = 1 TV + Hyst. above = 0 TV below = 0 TV + Hyst. above = 1 none 1 s 2 s 5 s 10 s 2 h none 1 s 2 s 5 s 10 s 2 h on change on change to 1 on change to 0 on change and periodically on change to 1 and periodically on change to 0 and periodically 5 s 10 s 30 s 1 min 2 h Blocking Use block of the humidity switching output Evaluation of the humidity blocking object Value of the humidity blocking object before 1. communication Behaviour of humidity switching output with blocking No Yes if value 1: block if value 0: release if value 0: block if value 1: release 0 1 do not send telegram send 0 send 1

30 Transmission protocol The behaviour with release of the switching output depends on the value of the parameter Humidity switching output sends... (see Humidity switching output ) Value of parameter Humidity switching output sends : on change on change to 1 on change to 0 on change and periodically Setting options Behaviour of humidity switching output with release : do not send telegram send status of the switching output do not send telegram if switching output = 1 send 1 do not send telegram if switching output = 0 send 0 send status of the switching output (no selection) on change to 1 and periodically if switching output = 1 send 1 (no selection) on change to 0 and periodically if switching output = 0 send 0 (no selection)

31 Transmission protocol 5.8. Humidity PI control Use control No Yes

32 Transmission protocol If the control is used General humidity control: Type of control Controller target value: One-stage dehumidification Two-stage dehumidification Humidification and dehumidification Behaviour of the blocking object with value 1 = block control 0 = release control 0 = block control 1 = release control Value of the blocking object 0 1 before 1. communication Target value setpoint per Parameter Communication object If the target value is set per Parameter: Target value setpoint per Parameter Target value in % 0 100 Dead zone between humidification and dehumidification in % (only if type of control is a humidification and dehumidification) Humidification starts with rel. humidity Target value - dead zone 0 100 If the target value is set per Communication object: Target value setpoint per The value communicated last shall be maintained Start target value in % valid until 1. communication (only if the value communicated last is not maintained or after restoration of voltage ) Type of the target value change Step size (only with Increment/decrement ) Communication object not after restoration of voltage after restoration of voltage and programming (Do not use for first commissioning) 0 100 Absolute value Increment/decrement 0,1 C 0,2 C 0,3 C 0,4 C 0,5 C 1 C 2 C 3 C 4 C 5 C

33 Transmission protocol Dehumidification/Dehumidification 1. stage Maximum actuating variable is reached at target/actual difference of % 1 50 Re-setting time in mins 1 255 If blocked, the actuating variable shall Value in % (only if a specific value is sent) not be sent send a specific value 0 100 With release, the actuating variable follows the control Dehumidification 2. stage (Appears only if two-stage dehumidification is used) Target value difference between 1. and 2. stage in % Maximum actuating variable is reached at target/actual difference of % 0 50 1 50 Re-setting time in mins 1 255 If blocked, the actuating variable shall Value in % (only if a specific value is sent) not be sent send a specific value 0 100 With release, the actuating variable follows the control Humidification (Appears only if humidification and dehumidification is used) Maximum actuating variable is reached at target/actual difference of % 1 50 Re-setting time in mins 1 255 If blocked, the actuating variable shall Value in % (only if a specific value is sent) not be sent send a specific value 0 100 With release, the actuating variable follows the control

34 Transmission protocol 5.9. Dew point temperature Use dew point temperature No Yes If dew point temperature is used: Dew point temperature From change of (only if sending in case of change ) Send periodically all (only if sending periodically ) Use monitoring of the cooling medium temperature do not send send periodically send in case of change send in case of change and periodically 2% 5% 10% 25% 50% 5 s 10 s 30 s 1 min 2 h No Yes 5.9.1. Cooling medium temperature sensor This point only appears if Use monitoring of the cooling medium temperature: Yes is set in the dew point temperature menu.

35 Transmission protocol Minimum cooling medium temperature threshold value Threshold value = dew point temperature + offset The offset set last shall be maintained not after restoration of voltage after restoration of voltage and programming (Do not use for first commissioning)

36 Transmission protocol Offset in C (only if the offset set last is not maintained or after restoration of voltage ) Step size for offset change per communication object 0 20 0,1 C 0,2 C 0,3 C 0,4 C 0,5 C 1 C 2 C 3 C 4 C 5 C Hysteresis of the threshold value in % 0 50 Threshold value do not send send periodically send in case of change send in case of change and periodically From change of 2% 5% 10% 25% 50% (only if sending in case of change ) Send periodically all (only if sending periodically ) 5 s 10 s 30 s 1 min 2 h Switching output Output is at (TV = Threshold value) Switching delay from 0 to 1 Switching delay from 1 to 0 Switching output sends Send periodically all (only if sending periodically ) TV above = 1 TV Hyst. below = 0 TV above = 0 TV Hyst. below = 1 TV below = 1 TV + Hyst. above = 0 TV below = 0 TV + Hyst. above = 1 none 1 s 2 s 5 s 10 s 2 h none 1 s 2 s 5 s 10 s 2 h on change on change to 1 on change to 0 on change and periodically on change to 1 and periodically on change to 0 and periodically 5 s 10 s 30 s 1 min 2 h Blocking Use block of the switching output Evaluation of the blocking object Value of the humidity blocking object before 1. communication Behaviour of switching output with blocking No Yes if value 1: block if value 0: release if value 0: block if value 1: release The behaviour with release of the switching output depends on the value of the parameter Switching output sends... (see Switching output ) 0 1 do not send telegram send 0 send 1

37 Transmission protocol Value of parameter Switching output sends : on change on change to 1 on change to 0 on change and periodically 5.10. Absolute humidity Setting options Behaviour of Switching output with release : do not send telegram send status of the switching output do not send telegram if switching output = 1 send 1 do not send telegram if switching output = 0 send 0 send status of the switching output (no selection) on change to 1 and periodically if switching output = 1 send 1 (no selection) on change to 0 and periodically if switching output = 0 send 0 (no selection) Use absolute humidity No Yes If absolute humidity is used Unit object 65: g water / kg air Unit object 66: g water / m3 air

38 Transmission protocol Transmission behaviour From change of (only if sending in case of change ) Send periodically all (only if sending periodically ) do not send send periodically send in case of change send in case of change and periodically 2% 5% 10% 25% 50% 5 s 10 s 30 s 1 min 2 h 5.11. Comfort field Use comfort field No Yes If the comfort field is used Transmission behaviour Send periodically all (only if sending periodically ) maximum temperature in C (Standard = 26 C) on change on change to 1 on change to 0 on change and periodically on change to 1 and periodically on change to 0 and periodically 5 s 10 s 30 s 1 min 2 h 25 40

39 Transmission protocol minimum temperature in C (Standard = 20 C) maximum relative humidity in % (Standard = 65%) minimum relative humidity in % (Standard = 30%) maximum absolute humidity in 0,1 g/kg (Standard = 11,5 g/kg) Standard values correspond to DIN 1946. 10 21 52 90 10 43 50 200 Hysteresis of temperature: 1 C Hysteresis of relative humidity: 2% RH Hysteresis of absolute humidity: 2 g/kg 5.12. Logic Communication objects logic inputs do not release release AND Logic Logic 1/2/3/4 not active active

40 Transmission protocol OR Logic Logic 1/2/3/4 not active active 5.12.1. AND Logic 1/2/3/4 1. / 2. / 3. / 4. Input do not use all switching events which the sensor provides (see Linkage inputs of the AND logic ) Logic output sends not one 1 bit object two 8 bit objects If the logic output sends one 1 bit object: Logic output sends If logic = 1 object value 1 0 If logic = 0 object value 0 1 Communication object AND Logic 1 / 2 sends Send periodically all (only if sending periodically ) If the logic output sends two 8 bit objects: Logic output sends If logic = 1 object A value 0 255 If logic = 0 object A value 0 255 If logic = 1 object B value 0 255 If logic = 0 object B value 0 255 Communication object AND Logic 1 A and B send Send periodically all (only if sending periodically ) 5.12.2. Linkage inputs of AND logic one 1 bit object on change of logic on change of logic to 1 on change of logic to 0 on change of logic and periodically on change of logic to 1 and periodically on change of logic to 0 and periodically 5 s 10 s 30 s 1 min 2 h two 8 bit objects on change of logic on change of logic to 1 on change of logic to 0 on change of logic and periodically on change of logic to 1 and periodically on change of logic to 0 and periodically 5 s 10 s 30 s 1 min 2 h do not use Communication object logic input 1 Communication object logic input 1 inverted

41 Transmission protocol Communication object logic input 2 Communication object logic input 2 inverted Communication object logic input 3 Communication object logic input 3 inverted Communication object logic input 4 Communication object logic input 4 inverted Communication object logic input 5 Communication object logic input 5 invertiert Communication object logic input 6 Communication object logic input 6 inverted Communication object logic input 7 Communication object logic input 7 inverted Communication object logic input 8 Communication object logic input 8 inverted Temperature threshold value 1 Temperature threshold value 1 inverted Temperature threshold value 2 Temperature threshold value 2 inverted Temperature threshold value 3 Temperature threshold value 3 inverted Temperature threshold value 4 Temperature threshold value 4 inverted Malfunction sensor Malfunction sensor inverted 5.12.3. OR Logic 1/2/3/4 1. / 2. / 3. / 4. Input do not use all switching events which the sensor provides (see Linkage inputs of the OR logic ) Logic output sends one 1 bit object two 8 bit objects If the logic output sends one 1 bit object: Logic output sends If logic = 1 object value 1 0 If logic = 0 object value 0 1 Communication object OR Logic 1 / 2 sends one 1 bit object on change of logic on change of logic to 1 on change of logic to 0 on change of logic and periodically on change of logic to 1 and periodically on change of logic to 0 and periodically

42 Transmission protocol Send periodically all (only if sending periodically ) 5 s 10 s 30 s 1 min 2 h If the logic output sends two 8 bit objects: Logic output sends If logic = 1 object A value 0 255 If logic = 0 object A value 0 255 If logic = 1 object B value 0 255 If logic = 0 object B value 0 255 Communication objects OR Logic 1 /2 A and B send Send periodically all (only if sending periodically ) 5.12.4. Linkage inputs of OR Logic two 8 bit objects on change of logic on change of logic to 1 on change of logic to 0 on change of logic and periodically on change of logic to 1 and periodically on change of logic to 0 and periodically 5 s 10 s 30 s 1 min 2 h AND Logic output 1 AND Logic output 1 inverted AND Logic output 2 AND Logic output 2 inverted AND Logic output 3 AND Logic output 3 inverted AND Logic output 4 AND Logic output 4 inverted

43 Transmission protocol

Elsner Elektronik GmbH Control and Automation Technology Herdweg 7 D 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0 info@elsner-elektronik.de Germany Fax +49 (0) 70 56 / 93 97-20 www.elsner-elektronik.de