event physics experiments

Similar documents
arxiv: v2 [physics.ins-det] 17 Oct 2015

arxiv: v1 [physics.ins-det] 9 Sep 2015

Peculiarities of the Hamamatsu R photomultiplier tubes

Scintillation Counters

The HPD DETECTOR. Michele Giunta. VLVnT Workshop "Technical Aspects of a Very Large Volume Neutrino Telescope in the Mediterranean Sea"

Light Collection. Plastic light guides

5. Scintillation counters

5. Scintillation counters

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

Advancement in development of photomultipliers dedicated to new scintillators studies.

Extension of the MCP-PMT lifetime

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Status of Primex Beam Position Monitor July 29 th, 2010

Experiment 10. The Speed of Light c Introduction Apparatus

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Components of Optical Instruments

CHAPTER 11 HPD (Hybrid Photo-Detector)

arxiv:hep-ex/ v1 19 Apr 2002

PMT Calibration in the XENON 1T Demonstrator. Abstract

Characterisation of SiPM Index :

Production of HPDs for the LHCb RICH Detectors

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Use of a Hybrid Photo Detector (HPD) in the MAGIC micro power LIDAR system

Performance of the MCP-PMTs of the TOP counter in the first beam operation of the Belle II experiment

PoS(PhotoDet 2012)058

The HERA-B Ring Imaging Cerenkov ˇ Detector

Silicon Photomultiplier

Status of the large area MCP-PMT in China

Advanced Materials Research Vol

A small dual-phase xenon TPC with APD and PMT readout for the study of liquid xenon scintillation

CHAPTER 8 PHOTOMULTIPLIER TUBE MODULES

83092 Photomultiplier Family

Pixel hybrid photon detectors

High collection efficiency MCPs for photon counting detectors

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

arxiv: v1 [physics.ins-det] 3 Feb 2011

Radiation transducer. ** Modern electronic detectors: Taking the dark current into account, S = kp + bkgnd over the dynamic range.

Characterization of 18mm Round and 50mm Square MCP-PMTs

Lecture 12 OPTICAL DETECTORS

Experimental Analysis of Luminescence in Printed Materials

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

CU-LASP Test Facilities! and Instrument Calibration Capabilities"

arxiv: v2 [astro-ph.im] 2 Jul 2012

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

Cosmic Ray Muon Detection

Testing the Electronics for the MicroBooNE Light Collection System

Measurement of the Speed of Light in Air

The Argonne 6cm MCP-PMT System. Bob Wagner for Argonne LAPPD Collaboration ANNIE Collaboration Meeting Monday 27 Oct 2014

XRF Instrumentation. Introduction to spectrometer

Photomultiplier & Photodiode User Guide

CHAPTER 3 BASIC OPERATING METHODS OF PHOTOMULTIPLIER TUBES

SCCH 4: 211: 2015 SCCH

Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows

Improvement of the MCP-PMT performance under a high count rate

COMPTON SCATTERING. Purpose. Introduction. Fundamentals of Experiment

This is a repository copy of A two-phase argon avalanche detector operated in a single electron counting mode.

Radiation detectors Photographic detection

Citation X-Ray Spectrometry (2011), 40(4): 2. Right final form at

Moderne Teilchendetektoren - Theorie und Praxis 2. Dr. Bernhard Ketzer Technische Universität München SS 2013

Timing and cross-talk properties of BURLE multi-channel MCP PMTs

Development of New Large-Area Photosensors in the USA

Chemistry Instrumental Analysis Lecture 7. Chem 4631

The Light Amplifier Concept

NIST EUVL Metrology Programs


A high resolution TOF counter - a way to compete with a RICH detector?

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

High Performance Photon Counting. User Manual PML-16-C. 16 Channel Detector Head for Time-Correlated Single Photon Counting. Becker & Hickl GmbH

David Jameson 4/4/2018

R. Lebert 1, K. Bergmann 2, O. Rosier 3, W. Neff 2, R. Poprawe 2

Ground-based optical auroral measurements

Digital trigger system for the RED-100 detector based on the unit in VME standard

The LUX Experiment Trigger and Data Acquisition Systems. Eryk Druszkiewicz April 15 th 2013

Properties of Injection-molding Plastic Scinillator for Fiber Readout

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

8854 Photomultiplier. 129-mm (5-inch) Diameter, 14-stage QUANTACON TM Type Having a Bialkali Photocathode and High- Gain Gallium-Phosphide Dynodes

Photoelectric effect

UV AQUAtracka. In-situ PMT Fluorimeter

Results on the LED Pulser System for the Hall A DVCS Experiment

Electronic Instrumentation for Radiation Detection Systems

Partial Replication of Storms/Scanlan Glow Discharge Radiation

MPPC versus MRS APD in two-phase Cryogenic Avalanche Detectors

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

PML Channel Detector Head for Time-Correlated Single Photon Counting

MCP photon detectors studies for the TORCH detector

Silicon Carbide Solid-State Photomultiplier for UV Light Detection

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

ORTEC Experiment 3. Gamma-Ray Spectroscopy Using NaI(Tl) Equipment Required. Purpose. Gamma Emission

Wavelength-shifting Optical Module (WOM)

Total Absorption Dual Readout Calorimetry R&D

AN ADVANCED STUDY OF SILICON PHOTOMULTIPLIER

High granularity scintillating fiber trackers based on Silicon Photomultiplier

Transcription:

Comparison between large area PMTs at cryogenic temperature for neutrino and rare Andrea Falcone University of Pavia INFN Pavia event physics experiments

Rare event physics experiment Various detectors dedicated to rare events physics (neutrino physics and Dark Matter search) use liquid noble gases (Argon, Xenon) as active medium. 2 Liquid noble gases act as scintillators: light is produced by excitation and recombination phenomena occurring after the passage of ionizing particles. Light collection is mandatory in this kind of detectors. It has been used both for identification of interacting particle (WArP, Xenon) and for triggering events (ICARUS).

Large area PMT at cryogenic temperature Various technological problem arise while working with liquid noble gases: work at cryogenic temperature ( 77 K and 165 K for Ar and Xe respectively) and VUV light emission (128 nm and 165 nm for Ar and Xe respectively). 3 Cryogenic temperature: special PMTs with bialkali (K 2 CsSb) deposited on Pt under-layers for photocathode and diodes, in order to extend the range of temperatures the devices can be operated at. VUV or UV light emission: PMTs are not usually sensitive to VUV emission, therefore windows need to be coated with wavelength shifters, an example being TetraPhenyl-Butadiene ( TPB ).

Tested PMTs 4 We tested new generation 8-inch PMTs in view of their use in future large mass detectors : Hamamatsu R5912 Mod and R5912-02 Mod and ET 9354 KB. Main characteristics of the devices at 77 K are reported below. Some problematic behaviour occurred while testing ET 9354 KB. We decided not to make tests on it at cryogenic temperature, before clarifications with the manufacturer. As no SER was detectable in this PMT, measurements are made with multi electron response. R5912 R5912-02 ET 9354 KB Dynodes 10 14 12 Alimentation Anode at ground Anode at ground First dynode at ground S.E.R. peak to valley 2.8 2,6 1 Rise Time 3.8 ns 3.6 ± 0.9 ns FWHM 4.4 ± 0.1 ns 5.0 ± 0. 8 ns

ETL 9357 FLA We adopt as reference the characteristics of ETL 9357 FLA PMTs, used in the ICARUS experiment. These PMTs worked very well for timing and trigger purposes of the experiment. 5 PMTs Cathode E E Read-out wire planes (TPC)

ETL 9357 FLA 6 Window diameter Provided 8 in (20 cm) Dynodes 12 Dynodes Material Alimentation K 2 CsSb on Pt layer First dynode at ground Q.E. at 400 nm 20% Measured at 77 K S.E.R. peak to valley 2.3 1.8 Rise Time 5 ns 3.9 ± 1.1 ns FWHM 8 ns 7.3 ± 1. 4 ns References Characterization of ETL 9357FLA photomultiplier tubes for cryogenic temperature applications NIM A 556 (2006) 146-157 The trigger system of the ICARUS experiment for the CNGS beam - arxiv:1405.7591 [physics.ins-det]

Overview 7 Characterization at room temperature Cathode uniformity Behaviour with the terrestrial magnetic field Gain Electron transit time Quantum efficiency with TPB coating Characterization at cryogenic temperature Gain Linearity Dark counts Conclusion

Photocathode uniformity 8 The PMT is enlightened with a 400 nm laser diode, by means of an optical fibre. Data are then analyzed with a Multi Channel Analyzer ( MCA ). A proper support is used, able to sustain the optical fibre, normal to the PMT window surfaces at various position. The SER is studied as a function of the position along two perpendicular orthodromes. PULSE GENERATOR LASER DIODE PRE AMP. AMP. ORTEC MCA

Photocathode uniformity Good photocathode uniformity in the central region (till 10 cm from centre) for the R5912. Worst uniformity and problem in part of the photocathode for the ET 9354 KB. ET 9354 KB R5912 ±10 % 9 ± 20 %

Photocathode uniformity 10 Further measurements were made for ET 9354 KB in the area highlighted previously, and they hint to a probable deformation of the photocathode ET 9354 KB Probable deformation of the photocatode

Behaviour in magnetic field 11 The PMT is enlightened with a 400 nm laser diode, by means of an optical fibre fixed at the centre of the PMT window. PMT axis is parallel to the ground. Different measurements are made turning the PMT on its own axis. For gain measurement same configuration as before is used ( pre-amplifier, amplifier and MCA analyzer). To measure the transit time, R5912 and R5912-02 signals are acquired directly with the oscilloscope. For the ET 9354 KB a TAC module and the MCA are used.

Behaviour in magnetic field Gain Measurement at different angles are reported, with unit intensity referred to measurement with μ-metal shielding. A significant dependence on the terrestrial magnetic fieldt is clearly visible. R5912-02 R5912 S E N W 12 30 % 35 % S E N W

Behaviour in magnetic field Gain 13 Measurements with fibre fixed at different distance from the centre of PMT indicate that the response is the less affected by magnetic field, the farther from the centre. This can be due to the non uniform electric field configuration inside the PMT. ET 9354KB 8 % 13 % S E N W

Behaviour in magnetic field Transit time R5912 14 S E N W ET 9354KB Transit time seems to be not affected by terrestrial magnetic field. It increases with increasing distance from the PMT window centre. S E N W

Q.E. with TPB coating: acquisition system 15 PMT under test (covered with TPB) Monochromator Reference Photodiode Deuterium lamp

Q.E. with TPB coating Quantum efficiency is measured, as a function of wavelength, by comparing the current produced on the photo-cathode with that collected with a reference diode, enlightened with the same amount of light. All PMTs show a Quantum Efficiency of the order of few percent to VUV incident light, when coated with TPB. Comparison is reported between Q.E. of different PMTs, at the wavelength of liquid Argon and liquid Xenon emission peaks. 16 LAr (128 nm) LXe (165 nm)

Characterization at cryogenic temperature 17 PMT are directly immersed in liquid Nitrogen, to test them in real experimental conditions. Measurement are carried out after a couple of days of rest in cryogenic environment. The PMT is enlightened with a 400 nm laser diode, by means of an optical fibre fixed at the centre of the PMT window. The fibre and the other cables are allowed to enter by a proper cap, used to preserve darkness conditions and thermal insulation. For gain measurement same configuration as before is used ( pre-amplifier, amplifier and MCA analyzer). Dark rate is measured with a counter and a discriminator. A complete spectrum can then obtained with a dedicated computer program that gradually increase the discrimination threshold. The data relative to 54 ETL 5397 FLA PMTs mounted on ICARUS T600 detector are shown as a reference.

Cryogenic temperature: Gain ETL 9357 FLA 18 ICARUS PMTs: values fitted by an exponential law G=exp(αV A ), as a function of the anode voltage V A. α= 0,017 and α= 0,015 relative to 300 K and 77 K respectively. Gain reduction at 77 K for the entire sample lies between 15% and 80%.

Cryogenic temperature: Gain 19 R5912-02 R5912 Values well fitted by a power law function G=V βn, as a function of the dynodic voltage V. n is the number of dynodes and β ranges between 0.7 and 0.8. Gain reduction at 77 K: 35 % for the R5912 and 34% for the R5912-02.

Cryogenic temperature: Linearity ETL 9357 FLA 20 ICARUS PMTs: linear up to 500 phe. No difference in linearity between room and cryogenic temperature.

Cryogenic temperature: Linearity 21 R5912 Linear up to 400 phe R5912 02 Saturation above10 phe

Cryogenic temperature: Dark Counts ETL 9357 FLA 22 ICARUS PMTs: dark rate lies between 0.6 and 1.8 khz for the entire sample. Dark counts increase with lowering temperature, due to a decrease of lattice energy of cathode material. This implies the rise of the electron escaping probability.

Cryogenic temperature: Dark Counts 23 R5912 R5912-02 300 K : dark rate > 1 khz only for very low threshold ( < 0.1 phe). Dark counts increase with lowering temperature, by a factor 3.5 and 2 for the R5912 and the R5912-02 respectively.

Conclusions We have investigated the behaviour of three different large area PMTs, Hamamatsu R5912 and R5912-02 and ET 9354 KB, to be used in liquefied noble gas detectors. 24 Data were collected both at room and cryogenic temperature, and a comparison was made with the ETL 9357 FLA, successfully employed in ICARUS T600 detector. All tested PMTs show a good photocathode uniformity, except for one case (ET 9354 KB), possibly due to manufacturing defects. In relation to the magnetic field, a huge variation of the gain as a function of PMTs direction is recorded. On the other end, no difference can be seen in the electron transit time. Some problematic behaviour occurred while testing ET 9354 KB. We decided not to make tests on it at cryogenic temperature, before clarifications with the manufacturer.

Conclusions Tested PMTs show a good behaviour at cryogenic temperature, and are suitable for cryogenic application : 25 suitability of the bialkali photocathode on Pt under-layer, to work and detect the light both at room and at cryogenic temperature, is verified; gain decrease at low temperature is of the order of 35% for the two devices; linearity up to 400 photoelectrons can be achieved for the 10 dynodes model; saturation occurs after 10 photoelectrons for the 14 dynodes one; increase of dark counts rate at cryogenic temperature does not hinder the use of the devices in real experimental condition.

26 Thank you!

27 Back up

Behaviour in magnetic field Transit time R5912 R5912-02 28 S E N W S E N W ET 9354KB Transit time seems to be not affected by terrestrial magnetic field. It increases with increasing distance from the PMT window centre. S E N W

Q.E. with TPB coating Quantum efficiency is measured, as a function of wavelength, by comparing the current produced on the photo-cathode with that collected with a reference diode, enlightened with the same amount of light. All PMTs show a Quantum Efficiency of the order of few percent to VUV incident light, when coated with TPB. 29 R 5912 ET 9354 KB

Q.E. with TPB coating 30 Comparison is reported between Q.E. of different PMTs, at the wavelength of liquid Argon and liquid Xenon emission peaks. Liquid Ar (128 nm) Liquid Xe (165 nm)