RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

Similar documents
RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

RE Product data sheet Characteristics. universal plug-in timing relay V AC - 1 C/O. Main. Complementary. Discrete output type

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

RENF22R2MMW Zelio Timer Relay - Modular

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Characteristics 5 TeSys k contactors and reversing contactors

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Protection components

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

Zelio Control Measurement Relays

Protection components

02/11/2015

02/11/2015

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

08/07/2015

Type CP-S, CP-C & CP-A Switch mode

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

27/04/2015

Electronic timer CT-SDD.22

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDS.22

Electronic timer CT-TGD.22

22/10/2012

Electronic timer CT-MFS.21

08/07/2015

05/09/2012

NS..S contactor relays - with spring terminals AC operated

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relays


Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

PART NUMBERING SYSTEM

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

02/11/2015

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

02/11/2015

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

References 1 for asynchronous motors 1

24/07/2012

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

02/11/2015

Transcription:

Characteristics adjustable on-delay timing relay - 0.05..1 s - 24 V AC DC - 2OC Price* : 189.00 USD Discontinued Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Complementary Discrete output type Contacts material Width pitch dimension [Us] rated supply voltage Voltage range Connections - terminals Tightening torque Setting accuracy of time delay Dec 24, 2018 Zelio Time Industrial timing relay 2 C/O RE7 A 0.05 s...300 h Relay 90/10 silver nickel contacts 0.89 in (22.5 mm) 110...240 V ACat 50/60 Hz 24 V AC/DC at 50/60 Hz 42...48 V AC/DCat 50/60 Hz 0.85...1.1 Us Repeat accuracy +/- 0.2 % Temperature drift Voltage drift Minimum pulse duration Reset time Maximum switching voltage Mechanical durability [Ith] conventional free air thermal current Screw terminals, clamping capacity: 2 x 1.5 mm² flexible with cable end Screw terminals, clamping capacity: 2 x 2.5 mm² flexible without cable end 5.31...9.73 lbf.in (0.6...1.1 N.m) +/- 10 % of full scale < 0.07 %/ C < 0.2 %/V 20 ms 50 ms 250 V AC/DC 20000000 cycles 8 A [Ie] rated operational current <= 2 A DC-13 24 Vat 158 F (70 C) conforming to IEC 60947-5-1/1991/VDE 0660 <= 3 A AC-15at 158 F (70 C) conforming to IEC 60947-5-1/1991/VDE 0660 <= 0.1 A DC-13 250 Vat 158 F (70 C) conforming to IEC 60947-5-1/1991/VDE 0660 <= 0.2 A DC-13 115 Vat 158 F (70 C) conforming to IEC 60947-5-1/1991/VDE 0660 Minimum switching capacity 12 V / 10 ma 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Potentiometer characteristic Marking Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage Supply disconnection value Operating position Linear 47 kohm (+/- 20 %), 0.2 W, cable length: 25 m Z1Z2terminal(s) CE 250 V between contact circuit and control inputs IEC certified 250 V between contact circuit and power supply IEC certified 300 V between contact circuit and control inputs CSA certified 300 V between contact circuit and power supply CSA certified > 0.1 Uc Any position without derating Surge withstand 2 kv conforming to IEC 61000-4-5 level 3 Power consumption in VA Power consumption in W Terminal description Height Width Depth Product weight 2 VA 48 V 1.2 VA 24 V 12.5 VA 240 V 2.8 VA 110 V 0.8 W 24 V 1.6 W 48 V (Z2)UNUSED ALT (Z1)UNUSED (15-16-18)OC_OFF (25-26-28)OC_ON (B1-A2)CO 3.07 in (78 mm) 0.89 in (22.5 mm) 3.15 in (80 mm) 0.33 lb(us) (0.15 kg) Environment Immunity to microbreaks 3 ms Standards EN/IEC 61812-1 Product certifications Ambient air temperature for storage Ambient air temperature for operation GL CSA UL -40...185 F (-40...85 C) -4...140 F (-20...60 C) Relative humidity 15...85 % (3K3) conforming to IEC 60721-3-3 Vibration resistance 0.35 mm (f = 10...55 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn 11 ms conforming to IEC 60068-2-27 IP degree of protection IP20 (terminals) IP50 (housing) Pollution degree 3 conforming to IEC 60664-1 Dielectric strength Non-dissipating shock wave 2.5 kv 4.8 kv Resistance to electrostatic discharge 6 kv (in contact) conforming to IEC 61000-4-2 level 3 8 kv (in air) conforming to IEC 61000-4-2 level 3 Resistance to electromagnetic fields 9.14 V/yd (10 V/m) conforming to IEC 61000-4-3 level 3 Resistance to fast transients 2 kv conforming to IEC 61000-4-4 level 3 Disturbance radiated/conducted CISPR 22 - class A CISPR 11 group 1 - class A Ordering and shipping details Category 22376 - RELAYS-MEASUREMENT(RM4) Discount Schedule CP2 GTIN 00785901481508 Nbr. of units in pkg. 1 Package weight(lbs) 0.32000000000000001 Returnability N 2

Country of origin ID Contractual warranty Warranty period 18 months 3

Dimensions Drawings Width 22.5 mm Rail Mounting Screw Fixing 4

Connections and Schema Internal Wiring Diagram 5

Connections and Schema Recommended Application Wiring Diagram Start on Energisation 1 Supply 2 12 48 V 3 24 V 6

Connections and Schema Connection of Potentiometer 7

Connections and Schema Connection Precautions WARNING UNEXPECTED EQUIPMENT OPERATION No galvanic isolation between supply terminals and control inputs. Failure to follow these instructions can result in death, serious injury, or equipment damage. 8

Performance Curves Performance Curves A.C. Load Curve 1 Electrical durability of contacts on resistive loading millions of operating cycles X Y Current broken in A Millions of operating cycles A.C. Load Curve 2 Reduction factor k for inductive loads (applies to values taken from durability curve 1). X Power factor on breaking (cos ϕ) Y Reduction factor k Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3. For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3: k = 0.6 The electrical durability therefore becomes:1.5 10 6 operating cycles x 0.6 = 900 000 operating cycles. 9

D. C. Load Limit Curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load 10

Technical Description Function A : Power on Delay Relay Description The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 11

Technical Description Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/R2 2 timed outputs R2 inst.the second output is instantaneous if the right position is selected T Timing period Ta - Adjustable On-delay Tr - Adjustable Off-delay U Supply is replaced by: Relay Output RE22R2AMR On-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Qty 1 Reason for Substitution: End of life Substitution date: 01 January 2017 12