SONORA DESIGN DIRECTV MFH2 (6) INPUT PRODUCTS

Similar documents
POWER SUPPLIES 4SATPL-T POLARITY LOCKER LA144R 4SATPL SITUATION

SDPI6S FLEX 1 FLEX 2 TAMP6R03 (6) INPUT AMPLIFIER TAMP6 DIRECTV AMPLIFIER SITUATION SOLUTION RELATED CONSIDERATIONS DESCRIPTION FEATURES

BROADBAND DROP AMPLIFIER

BDA Broadband Drop Amplifier

Compact Node Optoelectronics

BDA Broadband Drop Amplifier

Compact Nodes and 90071

TELESTE AC AMPLIFIER MODULES

OPTICAL NODE TRUNK & DISTRIBUTION

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

Cisco 1218 MHz GainMaker High Gain Dual (HGD) System Amplifier

ADVANCED SYSTEM DESIGN PRODUCT SPECIFICATIONS MBE*/*

CXE180 UNIVERSAL AMPLIFIER

AC800 FIBRE OPTIC NODE

CXE180 UNIVERSAL AMPLIFIER

CXE202 UNIVERSAL AMPLIFIER

ANTENNAFIER TM 915LTX BLOCK DIAGRAM LNA

ACI SDLA. Miniflex Line Extender 1002 MHz

1 GHz SASMAX II series

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

AC3000 INTELLIGENT BROADBAND AMPLIFIER

GainMaker Line Extender 1 GHz with 65/86 MHz Split

ACI SDAF MHz Miniflex Configurable Bridger Amplifier

GainMaker Line Extender 1 GHz with 42/54 MHz Split

Data Sheet GTD21148L SERIES 40W. (201) Switching Power Supplies

750 MHz Magnamax series

Pa s s i v e s. 3 - way, 1 GHz Horizontal balanced splitter EA 200/ /6.2

SPECIFICATION AC/DC ADAPTOR. CUSTOMER SPEC:INPUT: V AC 50/60Hz OUTPUT:24VDC500mA SAMPLE NO: REV.: B ISSUE DATE:

amplifiers Phoenix Communication Technologies AMPLIFIERS PAGE DROP AMPLIFIERS DISTRIBUTION AMPLIFIER

GainMaker Low Gain Dual System Amplifier 1 GHz with 55/70 MHz Split

CXE202 UNIVERSAL AMPLIFIER

TELESTE AC NODE SPECIFIC MODULES

AC1000 AMPLIFIER & OPTICAL NODE PLATFORM

ACE2 INTELLIGENT BROADBAND AMPLIFIER

CXE880 FIBRE OPTIC NODE

Diamond Line 3 Single Output Amplifiers

CXE880 FIBRE OPTIC NODE

AC2000 AMPLIFIER PLATFORM

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

CXE880 FIBRE OPTIC NODE

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Satellite Radio Commercial Products Catalog

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

KU-BAND OUTDOOR BLOCK CONVERTERS

ATSBT-BOTTOM-FM-4G. Electrical Specifications. Product Classification. General Specifications. Mechanical Specifications. Bottom Smart Bias Tee

TXS. Amplifiers UHF,DAB and Band 2 Inputs TS dB Gain 108dBuV output* *Output Levels are to DIN. Ideal for Seperate Inputs FM,DAB,UHF

Mini Compact Outdoor GaN SSPAs in C-, X-, and Ku-Bands

IFR 4000 Portable Nav/Comm Test Set

CATV Product Family MEDIALINE 2000

AC500 AMPLIFIER PLATFORM

Cisco 1218 MHz GainMaker High-Gain Balanced Triple System Amplifier

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

Cisco GainMaker High Output High Gain Balanced Triple 1 GHz System Amplifier 5-85/ MHz

AC8000 FIBRE OPTIC PLATFORM

Arbitrary/Function Generator AFG1000 Series Datasheet

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

MBV3 1 GHz Amplifier MODEL

Function/Arbitrary Waveform Generator

Phase Combined Systems

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Switching Power Supply Type SPP1 60W Enclosed type

Electrical Data Voltage Supply. 56dB nom. ±2dB (fine ADJ available) Power Out compression) Min. 600W (Typ. 700W) Input Return Loss

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

RF Solutions SW 15th Street Deerfield Beach, FL

RECEIVER MULTICOUPLER AND R.F. PRESELECTORS

Accessories Distribution and Configuration Accessories

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

125W Ku-Band Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Spring Return DuraDrive Proportional Actuator

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

MONITOR BRACKETS CCTV SYSTEMS. BT7510S Ex GST Inc GST. BT7511S Ex GST Inc GST. BT7512S Ex GST Inc GST. BT7518S Ex GST Inc GST. BT7513S Ex GST Inc GST

KOP4800 Installation Guide

Block Upconverters for Integration in High Power Amplifiers

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

GPS-ITS. GPS Indoor Testing Solution Technical Product Data. Features. Description. Amplified Roof Antenna Gain 35dB

GainMaker Unbalanced Triple System Amplifier 1 GHz with 42/54 MHz Split

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated

PRA Series of Radio and TV Amplifier Power Supplies

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

CXE880 FIBRE OPTIC NODE

Triax Multiband and Distribution Amplifiers for community networks. Flexibility from trunk line to subscriber in current to future networks

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

HNRRKIT. Hangar Networked Re-Radiating Kit Technical Product Data

PNRRKIT. Portable Networked Re-Radiating Kit Technical Product Data. Features. Description. Utilizes Existing Roof Antenna

Compact Outdoor Solid State Power Amplifiers in S-, C-, X-, and Ku-Bands

Guide. Installation. Wilson Electronics, Inc. In-Building Wireless Amplifi er. Contents:

150W Ku-Band Compact Outdoor 1:1 Redundant System. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

40W Ka-Band Compact Outdoor SSPA with AC Input Option B

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Transcription:

SONORA DESIGN DIRECTV MFH2 (6) INPUT PRODUCTS 1 SD SA-6AL Trunk Amplifier Automatic Gain Control: 20 db window Weather Sealed Die-Cast Housing F-Connector Power Input Variable Color Signal Indicators Dual 10 AWG Ground Lugs SCTE Indoor F-Connectors SD PI-6S Trunk Power Inserter Powers SL5, 95W & 72.5W ODUs Regulated DC Voltages F-Connector Power Input Dual 10 AWG Ground Lugs Dual Color LED Indicators SCTE Indoor F-Connectors SD MST-6xx Trunk Tap Passes DC Voltage Out-to-In DC Blocking on Tap Port Dual 10 AWG Ground Lugs Tap values 6 db, 9 db, 12 db & 16 db SCTE Indoor F-Connectors SD SWM-E2 Dual SWM Expander Connect (2) SWM8 or SWM16 switches to one dish without splitters or jumpers Passes LNB power to dish from one SWM Dual 10 AWG Ground Lugs Replaceable F threaded to push-on quick connects SCTE Indoor F-Connectors Dual 10 AWG Ground Lugs PS242000A & PS121000A DC Power Supplies 24 Volt 2 Amp or 12 Volt 1 Amp Interchangeable AC Cord F-Connector for DC Input

SD PI-6S TRUNK POWER INSERTER 2 MDU switch able Power Inserter and Tone Generator Unit Simplifies MDU installations by providing an integrated module for locking LNB polarizations and satellite selection SD PI-6S Trunk Power Inserter Powers SL5, 95W & FLEX2 ODUs Regulated DC Voltages F-Connector Power Input Dual 10 AWG Ground Lugs Dual Color LED Indicators PS242000A DC Power Supplies 24 Volt 2 Amp Interchangeable AC Cord F-Connector for DC Input Parameter UNIT SD PI-6S Operating Frequency Range MHz 250-2150 db 1.5 (max.) Flatness in operating frequency range db ± 0.5 Number of Input Ports Each (6) SCTE Indoor F Number of Output Ports Each (6) SCTE Indoor F between ports db > 35 db Input / Output db > 10 (min) DC Power provided to inputs VDC Port #1 (20 V 101º & 99º) VDC 20 ± 0.5 Port #2 (13 V 101º & 99º) VDC 13.5 ± 0.5 Port #3 (22 khz & 20 V 119º & 103º) VDC 20 ± 0.5 (+ 22 khz) Port #4 (22 khz & 13 V 119/110º & 103º) VDC 13.5 ± 1 (+ 22 khz) Port #5 (Flex Port 1) VDC 20 ± 1 or 13.5 ± 1 (Internally switch able) Port #6 (Flex Port 2) VDC 20 ± 1 or 13.5 ± 1 (Internally switch able) LED Color corresponding to: GREEN AMBER VDC VDC 10.0-14.5 17.0-20.5 Number of LEDs Each 7 (1 per input & 1 for adaptor input) 22 khz Tone to ODU khz Frequency khz 22.0 ± 0.5 Duty Cycle % 50 Amplitude mvpp 800 (min) DC Power Path ma 1000 (max.) From DC Input to each Input DC Power Connector Type Each (1) SCTE Indoor F Switching Mode Power Supply 24 V, 1.2 A (min) Short Circuit Protection Yes, 1 A Multi fuse Lightning Surge Protection 32 V p-p, max shunt current 200 A; 8 msec, 1.5 kw max dissipation Ground Screws Each 2 Green Screw Ground pt. Dimensions L x W x H mm 136 x 217 x 23 Indoor use only Operating Temperature range ºC -34 to + 60 Indoor housing Shall survive 95% relative humidity

SD SA-6AL (6)TRUNK AMPLIFIER 3 Self-adjusting in-line trunk amplifier with LED signal level indicators Simplifies MDU installations by providing selfadjusting, automatic gain control for optimum signal level Provides LED indicators to show signal levels SD SA-6AL Trunk Amplifier Maximum Gain 30 db @ 2150 MHz Automatic Gain Control 22 db Weather sealed Die-Cast Housing F-Connector Power Input Variable Color Signal Indicators PS121000A DC Power Supply 12 Volt 1 Amp Interchangeable AC Cord F-Connector for DC Input Parameter UNIT SD SA-6AL Operating Frequency Range MHz 250-2150 Maximum Output (IM3, 35 dbc) 2 carriers @ 250 MHz @ 750 MHz @ 950 MHz @ 1450 MHz @ 2150 MHz -6.0 min -5.0 min -4.0 min -3.0 min -3.0 min Gain Below AGC db 20-25 min Fixed Slope Input Level (Colored LED Indicator) Red Blinking: Signal Below AGC window Green : Signal Inside AGC window Red : Signal is Above AGC window Input Signal < - 51 Input Signal @ - 50 to - 28 Input Signal > -28 Inter Stage Attenuator db 0 to 20 db min Satellite to Satellite db > 30 db Input db >10 Output db >10 Noise Figure db 7 (2150 MHz) Number of Inputs Each 6 SCTE Indoor F Number of Outputs Each 6 SCTE Indoor F Power Model PS121000A DC Power Pass (any Output to Input) ma 1000 (max) Input DC voltage VDC 10 (min.), 20 (max.) from any Output or 12 VDC from SMPS Power Adaptor Max Power Consumption ma 600 (max.) Lightning Surge Protection 32 V p-p, max shunt current 200 A; 8 msec, 1.5 kw max dissipation Ground Screws Each 2 Green Screw Ground pt. Dimensions L x W x H mm 136 x 217 x 23 Indoor Only Operating Temperature range ºC -34 to + 60 Storage Temperature ºC -50 to + 85 Shall survive 95% relative humidity

SD MST6xx MFH2 (6) TRUNK TAP 4 MFH2 Multi-Satellite Tap allows SWM expansion Chassis to be connected to a common satellite distribution backbone PARAMETER UNIT SD MST6xx SD MST6xx Trunk Tap (6) Trunk Capacity Passes DC Voltage Out-to-In DC Blocking on Tap Port 10 AWG Ground Lug LED Indicators Operating Frequency MHz 5-2150 MHz Number Input / Output / Tap Ports Each 6 SCTE Indoor DC Power Output to Input Amps 3 Ground Studs Each 2 Dimensions L x W x H mm 60 x 150 x 47 Operating Temperature ºC -34 to + 60 Indoor / Lock box Shall survive 95% relative humidity MODEL# Description UPC # SD MST606 (6) Input, 6 db Multi-Tap 609465599014 SD MST609 (6) Input, 9 db Multi-Tap 609465599021 SD MST612 (6) Input, 12 db Multi-Tap 609465599038 SD MST616 (6) Input, 16 db Multi-Tap 609465599045 SD MST606 6 db In-Out In - Tap Out - Tap INPUT OUTPUT TAP Port to Port 5-250 MHz 3.4 ±0.2 6.3 ±0.2 >18 db >12 db >12 db >12 db >45 db 250-1850 MHz 3.9 ±0.2 6.3 ±0.2 >18 db >12 db >12 db >12 db >45 db 1850-2150 MHz 5.3 ±0.2 6.9 ±0.2 >18 db >12 db >12 db >12 db >40 db SD MST609 9 db In-Out In - Tap Out - Tap INPUT OUTPUT TAP Port to Port 5-250 MHz 1.8 ±0.2 8.3 ±0.2 >18 db >12 db >12 db >12 db >45 db 250-1850 MHz 2.7 ±0.2 8.3 ±0.2 >18 db >12 db >12 db >12 db >45 db 1850-2150 MHz 5.2 ±0.2 7.2 ±0.2 >18 db >12 db >12 db >12 db >45 db SD MST612 12 db In-Out In - Tap Out - Tap INPUT OUTPUT TAP Port to Port 5-250 MHz 1.5 ±0.2 11.5 ±0.2 >18 db >12 db >12 db >12 db >35 db 250-1850 MHz 2.1 ±0.2 11.4 ±0.2 >18 db >12 db >12 db >12 db >35 db 1850-2150 MHz 3.3 ±0.2 10.6 ±0.2 >18 db >12 db >12 db >12 db >35 db SD MST616 16 db In-Out In - Tap Out - Tap INPUT OUTPUT TAP Port to Port 5-250 MHz 1.0 ±0.2 16 ±0.2 >18 db >12 db >12 db >12 db >35 db 250-1850 MHz 1.4 ±0.2 15.5 ±0.2 >18 db >12 db >12 db >12 db >35 db 1850-2150 MHz 2.2 ±0.2 15.5 ±0.2 >18 db >11 db >12 db >10 db >35 db

FLEX 1 FLEX 1 SD SA-6AL & SD MST6xx HIGH RISE MDU 5 ROOF -30 150 feet RG6-49 FLOOR 10-20 -21 99 110 119 101 103 SL5 SEQ509 worlddirect 101 95 DC SD SA-6AL FLEX 2 DC SD PI-6S PS24 2000A SD MST616-37 CA24R IN DC OUT 20 ft RG6 per floor 1 floor spacing 5 db ave loss including taps Tap per Floor, (5) Floor Amp Spacing Amplifier spacing is (5) floors with a minimum IDF output of -45. Model SD SA-6AL with automatic gain control simplifies the expansion of D Ka/Ku signals. They serve well in cascades for MDU multiple IDF applications. Note the FLEX2 port has extended bandwidth to allow amplification of Off-Air or CATV signals. Model SD MST6xx directional couplers follow amplifiers to feed distribution hubs. The typical insertion loss is listed. 9-24 SDMST616-40 MHz/ db 250 950 1450 1850 RG-6 100 ft 3.1 6.4 7.9 9.0 8-28 SDMST612-40 MST616 1.0 1.3 1.5 2.0 MST616 1.0 1.3 1.5 2.0 7-33 SDMST609-41 MST612 1.5 1.8 2.5 3.0 MST609 1.8 2.0 3.0 4.0 6-38 SDMST606-44 MST606 3.4 3.8 4.0 4.5 TOTAL 11.8 16.6 20.4 24.5-45 FLOOR 5 DC SD SA-6AL PS 12 1000 Tap output is the input level to the tap less the tap value ( -20 into a 16 db tap = -36 ) -20 SDMST616-36 SONORA measured 24 db insertion loss of the cascade for (5) taps and 100 feet of RG-6 at 1850 MHz to determine the 5 db average loss per tap. 4 3 2-23 -27-32 SDMST616-40 SDMST612-41 SDMST609-41 The loss at 250 MHz was 11 db. The SD SA-6AL internal slope compensation offsets 9 db of the 12 db slope. Select SWMBOX size and quantity based on subscriber penetration rates. 1-38 T T T T T T SDMST606-44

FLEX 1 FLEX 1 SD SA-6AL & SD MST6xx HIGH RISE MDU 6 ROOF FLOOR 16 15 14 13 12 11 10 9 FLOOR 8 7 6 5-30 150 feet RG6-45 -48-20 -21-26 -32-38 -46-20 -25 99 110 119 101 103 SL5 SEQ509 worlddirect 101 95 DC SD SA-6AL FLEX 2 DC SD PI-6S DC SD SA-6AL PS24 2000A SD MST616-37 SDMST612-38 SDMST609-41 PS 12 1000 SDMST616-36 CA24R IN DC OUT 18 ft RG6 per floor 2 floor spacing 6 db ave loss including taps SDMST606-44 SDMST612-37 Tap per (2) Floors, (8) Floor Amplifier Spacing Model SD SA-6AL amplifier spacing is (8) floors when taps are placed on alternating floors. Model SD SA-6AL is followed with model HRvT1xx taps spaced on alternating floors connected via RG-6 coax. The configuration lowers costs for low penetration buildings. Model SD MST6xx directional couplers follow amplifiers to feed distribution hubs. The typical insertion loss is listed. MHz/ db 250 950 1450 1850 RG-6 144 ft 4.7 9.2 11.4 13.0 MST616 1.0 1.3 1.5 2.0 MST612 1.5 1.8 2.5 3.0 MST609 1.8 2.0 3.0 4.0 MST606 3.4 3.8 4.0 4.5 TOTAL 12.4 18.1 22.4 26.5 Tap output is the input level to the tap less the tap value ( -20 into a 16 db tap = -36 ) SONORA measured 26 db insertion loss for the cascade of (4) taps and 144 feet of RG-6 at 1850 MHz to determine the 6 db average loss per tap. The loss at 250 MHz was 12 db. The SD SA-6AL internal slope compensation offsets 9 db of the 14 db slope. Use model SEQ509 in front of the SD SA-6AL on floor 8 for an additional 8 db slope compensation. 4 3-31 SDMST609-40 Select SWMBOX based on penetration rates. 2 1-37 T T T T T T SDMST606-43

SD SWM-E2 (2) SWM EXPANDER 7 MODEL# Description UPC # SD SWM-E2 MFH2 (6) Input splitter with Quick F interface to (2) SWM switches 609465599052 PS242000A SMPS power adaptor for SWM powering 609465599373 SD SWM-E2 SWM Expander Splits MFH2 signals to (2) SWMs Weather sealed Die-Cast Housing Precision Push-on F-Connectors (2) #10 AWG Ground Lugs Features Simplifies MDU installations by providing easy connection of (2) SWM8 or SWM16 switches Push-On adaptors are field replaceable (Model PF71-HR) Parameter UNIT SD SWM-E2 Operating Frequency Range MHz 250-2150 Number of Input Ports Each 6 Number of Output Ports Each 12 (6 per SWM Module) db -6 db Flatness @ 36 MHz db ± 0.5 In / Out db > 40 db Out / Out db 15 db typ. Input / Output db > 10 db Connectors Inputs type F female Outputs F female Output Adaptors type (10) F male to F female push on Quick F (model PF71-HR) Ground Studs Each 2 with Green Screw Dimensions L x W x H mm 60 x 150 x 47 Operating Temperature Range ºC -34 to + 60 Indoor / Lock box Shall survive 95% relative humidity PS242000A DC Power Supply 24 Volt 2 Amp Interchangeable AC Cord F-Connector for DC Input

18V 22k 18V 22k 13V 22k 13V 22k Flex Port1 Flex Port1 Flex Port2 Flex Port2 GARDEN STYLE MDU, 100 FT TO DISH 8 99 110 119 101 103 SL5 worlddirect 101 95 SD PI-6S and SD SWM-E2 FLEX 2 DC SD PI-6S DC+RF -40 (MIN) PS24 2000A DC HRFPIB 2-2300 MHz DC+RF PS24 2000A Legacy 1 Legacy 2 Legacy 3 18V 13V 99º/101º 103º/110º/119º Legacy 3 Legacy 2 Legacy 1 SWM8 99º/101º 103º/110º/119º 18V 13V Flex 18V 13V 22k 22k Port1 FACE DOWN SWM8 SWM1 PWR SWM2 OFF-AIR Flex Port2 OFF-AIR SWM2 SWM1 PWR When the dish is within 100 feet of the distribution closet, only polarity locking is required. Model SD PI-6S powers the LNBs polarity locks the internal LNB switches and blocks control signals from SWM switches from talking to the LNBs. Model SD SWM-E2 is connected to the SD PI-6S with color coded mini-jumpers model 5mJFP24. (2) TUNER 75% PENETRATION APT 1 APT 2 APT 3 APT 4 APT 5 APT 6 APT 7 APT 8 Model splitters are connected to SWM1 and SWM2 output connectors of the SWM8. Model FR0-01 band-stop filters prevent ALL multiroom viewing programs from being viewed by another apartment. APT 9 APT 10 APT 11 APT 12 99 110 119 101 103 SL5 worlddirect 101 95 SWM16 Legacy 1 SWM1 PWR Legacy 2 DC / PWR Legacy 3 SWM2 Legacy 4 FLEX1 OUT DC+RF DC+RF HRFPIB 2-2300 MHz DC SWM LA141R OUT 24V 24V 12V 12V PS 12 250 Most residential properties require more than two tuners per apartment. FLEX2 OUT FLEX 2 DC SD PI-6S PS24 2000A 99º/101º 103º/110º/119º 18V 13V Flex 18V 13V 22k 22k Port1 18V 13V 99º/101º 103º/110º/119º FLEX2 OUT FLEX1 OUT Legacy 4 FACE DOWN Flex Port2 PS24 2000A The above example can be quickly upgraded to (4) tuners per apartment (at 75% penetration) by replacing the SWM8 switches with SWM16 switches press-fit into the SD SWM-E2 expander. -40 (MIN) Legacy 3 Legacy 2 Legacy 1 SWM16 SWM2 DC / PWR SWM1 PWR (4) TUNER 75% PENETRATION Model splitters are connected to SWM1 and SWM2 output connectors of the (2) SWM16s. APT 1 APT 2 APT 3 APT 4 APT 5 APT 6 APT 7 APT 8 Model FR0-01 band-stop filters prevent ALL multiroom viewing programs from being viewed by another apartment. APT 9 APT 10 APT 11 APT 12

SONORA DESIGN DIRECTV TRUNK POWER SUPPLIES 9 PS121000A DC Power Supply Interchangeable AC Cord F-Connector for DC Output Parameter UNIT PS121000A Rated Input Voltage Vac 100 to 240 Operating Input Range Vac 90 to 264 Rated Input Frequency Hz 47 to 63 Rated Input Current A 0.4 max No Load Input Current ma < 20 Maximum Input Power W 16.58 AC Input Cable Feet 6 AC Input connector Mini 2 pin Nominal DC Output Voltage Vdc 12 Rated load current A 1 max Minimum load current A 0.05A Ripple & Noise mvp-p 120 DC Output Cable Feet 6 Switching Efficiency % 72 DC Power Connector Type Each (1) F Female DC Adaptor included Each (1) F71 Male to Male Short Circuit Protection Yes, Multi fuse Dimensions L x W x H mm 110 x 53 x 37 Indoor use only Ambient Temperature range ºC 0 to + 45 Shall survive 90% relative humidity Safety Ratings Agencies USA Canada Europe Japan Taiwan China Britain UL60950-1 CSA C22.2 NO.950 TUV/VDE-EN60950-1 J60950(H14)/J55001(H14) CNS13438 GB4943-2001 EN60950-1:2000

SONORA DESIGN DIRECTV TRUNK POWER SUPPLIES 10 PS242000A DC Power Supply Interchangeable AC Cord F-Connector for DC Output Parameter UNIT PS242000A Rated Input Voltage Vac 100 to 240 Operating Input Range Vac 90 to 264 Rated Input Frequency Hz 47 to 63 Rated Input Current A 1.2 max No Load Input Current ma < 20 Maximum Input Power W 58.6 AC Input Cable Feet 6 AC Input connector Mini 2 pin Nominal DC Output Voltage Vdc 24 Rated load current A 2.08 max Minimum load current A 0.05A Ripple & Noise mvp-p 240 Switching Efficiency % 85 DC Output Cable Feet 6 DC Power Connector Type Each (1) F Female DC Adaptor included Each (1) F71 Male to Male Short Circuit Protection Yes, Multi fuse Dimensions L x W x H mm 110 x 53 x 37 Indoor use only Ambient Temperature range ºC 0 to + 45 Shall survive 90% relative humidity Safety Ratings Agencies USA Canada Europe Japan Taiwan China Britain UL60950-1 CSA C22.2 NO.950 TUV/VDE-EN60950-1 J60950(H14)/J55001(H14) CNS13438 GB4943-2001 EN60950-1:2000

LA141R-T MFH2 SWM EXTENDER 11 SWiM Output amplifier with integrated sub-band diplexer Provides 14 db of gain which offsets an additional 200 ft of RG-6 Passes 2 to 40 MHz signals in both directions for SWM & data modem communication Parameter UNIT LA141R-T Operating Frequency Range MHz MHz MHz MHz 54-940 (Off-Air / SMATV) 950-2150 (SWiM) 2.3 (FSK Communication Channel) 30-40 (Return Path) IM2 / IM3 2 carriers @ 250 MHz (-2 Out) @ 750 MHz (-1 Out) @ 950 MHz ( 0 Out) @ 1450 MHz ( +2 Out) @ 1650 MHz (+3 Out) @ 2150 MHz (+3 Out) dbc dbc dbc dbc dbc dbc IM3 ΔF 6 MHz, IM2 ΔF 400 MHz > 45 > 45 > 45 > 45 > 45 > 45 Number of Input / Output Ports Each (1) F Input / Output 2 to 40 MHz 54 to 250 MHz 250 to 2150 MHz Gain / Loss db db db Note > 8 db > 10 db >14 db 2.3 MHz db -3 maximum 54 MHz db 8 minimum 250 MHz db 9 minimum 950 MHz db 14 minimum 2150 MHz db 16 minimum Flatness @ 36 MHz db ± 0.25 DC Power Model PS12250 DC Power pass (Output to Input) ma 1500 (max) Input DC Voltage VDC 10 (min.), 28 (max.) from Input, Output or SMPS Power Adaptor AMP DC Power Connector Type (2) F DC Power Indication Each Green LED Power Consumption W 1.2 @ 12V max Lightning Surge Protection 32V p-p, max shunt current 200A; 8 msec, 1.5kW max dissipation Ground Screw Each 1 Screw Ground point Dimensions L x W x H mm 89 x 101 x 23 Indoor Only Operating Temperature range ºC -34 to + 60 Indoor / Lock box Shall survive 95% relative humidity

SONORA DESIGN POWER SUPPLIES 12 PS12250 DC Power Supply Small Footprint F-Connector for DC Output Parameter UNIT PS12250 Rated Input Voltage Vac 100 to 240 Operating Input Range Vac 90 to 264 Rated Input Frequency Hz 47 to 63 Rated Input Current A 0.15 max No Load Input Current ma < 15 Maximum Input Power W 5.01 AC Input Connector Type US PIN Nominal DC Output Voltage Vdc 12 Rated load current A 0.25 max Minimum load current A 0.0 A Ripple & Noise mvp-p 100 DC Output Cable Feet 1 Switching Efficiency % 59 DC Power Connector Type Each (1) F Female DC Adaptor included Each (1) F71 Male to Male Short Circuit Protection Yes, Multi fuse Dimensions L x W x H mm 56 x 35 x 24 Indoor use only Ambient Temperature range ºC 0 to + 45 Shall survive 90% relative humidity Safety Ratings Agencies USA Canada Europe Japan Taiwan China Britain UL60950 CSA C22.2 NO.950 TUV/VDE-EN60950 J60950(H14)/J55001(H14) CNS13438 GB4943-2001 EN60950-1:2000