WEBS-MT/R Tower Installation Instructions

Similar documents
WEBS-MT/R Tower Installation Instructions

96 (Standard Length)

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

4832A Installation Sheet Part List

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

INSTALL INSTRUCTIONS K9-F14-PT K9/PRISONER TRANSPORTATION SYSTEM FORD EXPEDITION

How To Install Weather Pack Bulkhead Wire Connectors

Monster Tower Phone: U.S. Hwy 411 S. HS1. Installation Instructions and Owner s Manual CAUTION

Powerware Series. Eaton Rail Kit 9- and 12-Slot Cabinets Installation Guide

VHF 100/200 Series Radio Installation Instructions

Cable Tray Kit: - Cable Tray - Cable Tray Cover - Power Block Support (x2) Top Support Kit: (x2) - 2 Top Supports. Quantities are per bench

Office Partitions WARNING. Assembly Instructions. Customer Service A S S E M B LY HARDWARE H1 H2 H3 H4 H5 H8 H9 H10 H11 H12

WMA 4300 Professional Series Installation Power Amplifer Owner s Manual

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder

Qt 600. Sound Masking - Paging - Music Installation Guide. Purchase date: Install date: MAC Address

These below wires are the input RCA Plugs.

COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008

Page 1 of 6 Systems Inc.

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

Speaker Audio System Cables

INSTALLATION INSTRUCTIONS KK-K9-F14-K K9 KIT FOR FORD EXPEDITION

BIKE FILE (301)

Installation Instructions

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

RBP-1215B-RX DODGE RAM QUAD CAB RX3

MobileTrak5 Installation Instructions

2010 KIDS CENTER #6 K-06

User Instructions Multiline Otter Scoreboard Caddy Assembly

Toll Free: INSTALLATION MANUAL. Copyright 1996 Revision 1 November 2004

OFS ED-6C Instruction Sheet LIGHTGUIDE CROSS-CONNECT Comcode: LGX DISTRIBUTING FRAME INSTALLATION

VHF 100/200 Series Radio Installation Instructions

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Panel & Shelf Identification

Powerware 9155 UPS Seismic Kit Installation Instructions

ABM International, Inc. Navigator Assembly Manual

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

2.0 INSTALLATION PROCEDURE. 2.1 Open the Speaker Post. 2.2 Install the Speaker and Microphone Grills. Figure 2. SPP2 rear view

Installation Instructions Road King Classic Saddlebag Bezels

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide

SAN12 ( <00>)

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

DUAL ADJUSTABLE PULLEY IP-D9302 INSTALLATION INSTRUCTIONS


Stainless Steel Bench Stand

HARDWARE KIT # KKM or Rear Compartment: (Some hardware not used in all applications)

INSTALLATION INSTRUCTIONS / DODGE RAM CREW CAB 2500/3500

SYSTIMAX 12A1 Cable Clamp Kit Instructions For Crossply-, R/L-, and LXE-Type Cable

General Prisoner Transport Install Instructions PT-2-INST

Melamine Plastic Laminate. Toilet Partition Installation Manual

MITSUBISHI DATA BUS INTERFACE MITO-01 INSTALLATION INSTRUCTIONS

Arducopter 3DR-B Hardware

Track Rack. * Track Racks are not lockable

MS-CEFB Filter Box. Installation Guide

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Therma-Tru Door Gallery Setup Instructions Swing Unit with Hardware Kit - Hardware Part # MADGSWU15 (Swing Unit) Part # MADGHKSU10 (Hardware Kit)

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Includes Instructions on Installation, Programming, and Troubleshooting for use with G-TEL Payphones with Model Series-5 Elcotel Smart Chassis

Parts and tools needed for installation- Cleaning and Painting -

Install Instructions. NewAge Steel Welded Tall Locker

LLK-AR45 LED Lighting Heatsink Enclosure Kit. LLK-AR45 LED Illuminator Heatsink Enclosure Kit

Video Wall Installation Instructions 2W X 3H, 3W X 3H

Preference Collection and Treatment Console INSTALLATION GUIDE

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

Installation Instructions for CMS Pro Meter (with Breakout Box Type-A) for Yamaha V-Max 1700

LAN Locker Adjustable Shelves

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

BEGINNER'S GUIDE TO AUDIO CONNECTIONS Copyright 2011 by Bruce Bartlett

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

ALUMINUM POLE VAULT STANDARDS SPECIFICATIONS

BASEBALL FOUL POLES SURFACE MOUNTED

Signature Choral Riser Side Rail

VX-3000 Series Voice Alarm and Public Address System

TOYOTA TUNDRA CARGO DIVIDER Preparation. Part Number: PT

MODEL T28173/T28174 ROLLER TABLES INSTRUCTIONS

Mounting Instructions Item No.: xxx

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

5570M Series Intercom Installation and Operation Guide

Installation Instructions

4099T Parts List. Front Bow Assy. (1) Rear Bow Assy. (1) Long Mounting Rail (2) Short Mounting Rail (2)

Installation Manual February Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel

TREX POST MOUNT DECKING AND CONCRETE

Traffic Safety Corporation

Senior Swing. Caution

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

PagePac Plus AmpliCenter V /V /V

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

INSTALLATION INSTRUCTIONS

Phone #: (360) Online Tech Support: Web: Inventory

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Tutorial Building the Mono Amp Case

R/L, AND LXE TYPE CABLE

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

D. Drill Bolt Holes Through Topper Shell and Bed Rails

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

Transcription:

I. Introduction This manual is for tower installation only. For instructions on installing the anchor bolts into the foundation, see the ETP-MT/R Anchor Bolt Installation Instructions. II. Contents Before beginning installation, make sure you have all the included components. Each WEBS-MT/R tower consists of the following packages. Package #1 contains the WEBS-MT/R tower itself. Package #2, labeled MT/R BOLT KIT contains the anchor bolt install kit. Package #3, labeled TOWER PTS, contains the tower hardware and lighting installation kit. Package #4, labeled WEBS-MT/R-KIT contains the WEBS paging kit. Package #5, labeled WEBS-BACKUP (sold separately) contains the WEBS power back-up kit. Emergency phones are sold and shipped separately (with mounting screws included). MT/R BOLT KIT TOWER PTS QTY Part Number Description 4 42838 J-Bolts 1 24718 MT/R Aluminum Mounting Template QTY Part Number Description 8 42839 3/4"-10 Hex Nut 8 42840 3/4" Washer 3 42841 10-24 x 3/4" Pan Head Tamper-proof Screw 2 42843 6-32 Hex Nut 1 68590 LED Faceplate Light 1 68559 LED Blue Light (12/24VDC) WEBS-MT/R-KIT QTY Part Number Description 1 WEBS-TERMAL Terminal Blocks on D rail 1 WEBS-MIC Local Paging Microphone 1 Lower Mounting Panel 1 Main Upper Mounting Panel 1 Secondary Upper Mounting Panel 1 WEBS-AMP-1 Paging Amplifier (Attached to Main Upper Mounting Panel) WEBS-VCU WEBS-Volume Control Unit(Attached to Main Upper Mounting Panel) 1 4 19667 RCA Cable 12 42896 6-32 Hex Nut 1 WEBS-PSU Power Supply 12VDC (not included if WEBS-BACKUP is used) 6 19684A 22 AWG twisted pair Orange-Orange/Black 6 19684E 22 AWG twisted pair Gray-Gray/Black 6 6303 22 AWG pair with shielded Brown-Green Copyright 2014 Talk-A-Phone Co. All rights reserved. Rev. 01/23/2017

WEBS-BACKUP (optional) QTY Part Number Description 1 86383 WEBS-UPS 2 68594 12VDC Battery 1 25192 Mounting shelf for battery 4 4247 Screws #8-32 x 0.5 L 18 4248 Hex nut #8-32 18 42767 #10 round hole washer III. Physical Installation 1. Install one 3/4 nut and one washer on each anchor bolt 2.5-3.5" above grade to top of washer. This will allow for a 1/2" air gap between the foundation and the tower which will allow airflow and prevent moisture problems. Verify that the nuts are level (0 pitch). NOTE: To insure proper grounding of all electrical components, the tower mount should be effectively earth grounded from the grounding stud (located across from the lower access panel) with 6 AWG or better insulated, stranded copper wire to the metallic power service raceway (conduit) or an 8' or longer corrosion-resistant ground spike. 2. After removing the lower access panel of the tower, install the tower onto the bolts with the Emergency Phone opening oriented in the desired direction. Install second set of nuts and washers. Tighten the upper nuts; the bottom set is only for leveling. Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 2 of 9

Figure 1. Installing the LED Blue Light. 3. Take off the tower cap plate as shown in Figure 1. Install the LED Blue Light to the base of the LED blue light housing. Reattach the tower cap plate. 4. Remove the rear access panel (top) of the tower and mount the paging amplifier vertically aligned (power connection / speaker output side facing up and audio input side facing down) with the help of four (4) #10-32 nuts provided. Also mount the WEBS-VCU on to the upper mounting panel of the tower as shown in Figure 2, use four (4) #10-32 nuts. Connect the paging amplifier audio input channels to the respective audio outputs on the WEBS-VCU via RCA audio cables provided. (e.g. Amplifier audio input channel 1 to WEBS-VCU audio output 1). Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 3 of 9

Figure 2. Installing the Paging Amplifier and the WEBS-Volume Control Unit (WEBS-VCU). 5. If using the WEBS-BACKUP option, place the mounting shelf on the two L-brackets located in the lower section of the tower. Rest the batteries in the upright position on the shelf. Mount the WEBS- UPS-84-20 on to the mounting panel and secure the assembly in place onto the mounting screws provided. Connect the DC output end (black and white color cables with gray jacket and fuse one end) to the D Rail Terminal Block, terminal no. 23 and 25 as shown in Table 1. Connect the battery input cables (red and black cable with ring terminals on each end) to the terminals of one battery (Red cable to the positive terminal of the battery and black cable to the negative terminal of the battery). Repeat the same procedure for the second battery. Connect the 120 VAC input cable (cable with three prong connector on end) to a 120VAC power source. OR 5. Install the lower mounting panel, using the wingnut provided with the tower. Connect the power supply by connecting the Brown lead to Line, Blue lead to neutral and the Green/Yellow lead to ground. Connect the DC output to the D Rail Terminal Block, terminals no. 23(yellow) and 25(black) as shown in Table 1. Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 4 of 9

Terminal # (Side A) Connection Terminal # (Side B) 1 28 Connection 2 29 3 Emergency Phone AUX. Output # 2 30 LED Blue Light [Orange] 4 Emergency Phone AUX. Output # 2 31 LED Blue Light 5 Emergency Phone AUX. Output # 3 32 Auxiliary Device Trigger Wire 6 Emergency Phone AUX. Output # 3 33 Auxiliary Device Trigger Wire 7 8 19 10 11 12 13 14 Local Paging Microphone [White] Local Paging Microphone [Green] Local Paging Microphone 12 VDC Trigger [Red] Local Paging Microphone 12 VDC Trigger WEBS-CM-2 / VOIP-500 (AUX. Output # 1) OR WEBS-ZPS 12 VDC Trigger [Grey] WEBS-CM-2 / VOIP-500 (AUX. Output # 1) OR WEBS-ZPS 12 VDC [Grey/Black] WEBS-CM-2 / VOIP-500 OR WEBS-ZPS [Brown] WEBS-CM-2 / VOIP-500 OR WEBS-ZPS [Green] 15 WEBS-ZPS Bare Shield [Yellow] 42 16 Not Used 43 17 Not Used 44 18 Not Used 45 19 Not Used 46 34 35 36 37 38 39 40 41 WEBS- VCU [Microphone Input] [White] WEBS- VCU [Microphone Input] [Green] WEBS-VCU [Microphone Input] 12 VDC Trigger [Red] WEBS- VCU [Microphone Input] 12 VDC Trigger ZPS Input] 12 VDC Trigger [Green] ZPS Input] 12 VDC [White] ZPS Input] [Red] ZPS Input] ZPS Input] Bare Shield [Yellow] WEBS-CM-2 12 VDC Power Face Plate Light 12 VDC Power LED Blue Light 12 VDC Power Paging Amplifier 12 VDC Power 20 Not Used 47 WEBS-VCU / Paging Amplifier Shield 21 Power Supply / Battery 12 VDC 22 Connect to GROUND 49 GROUND 23 Power Supply / Battery 12 VDC [Yellow] 24 Not Used 51 25 Not Used 52 26 Not Used 53 27 Not Used 54 48 50 WEBS-VCU 12 VDC Power [Black or Green] WEBS-VCU 12 VDC Power [Red or Brown] Paging Amplifier 12 VDC Power [Red or White] LED Blue Light 12 VDC Power [White] Face Plate Light 12 VDC Power [Red] WEBS-CM-2 12 VDC Power [Red] Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 5 of 9

Table 1. WEBS-MT/R D Rail Terminal Block Connections. 6. Install the LED light board over the phone opening. Slide the LED board over the studs with the LEDs facing down. Tighten down using the enclosed #6-32 nuts. Be careful not to over tighten to avoid cracking the circuit board. 7. Install the D rail on the two welds studs behind the phone opening. Install the local paging microphone and mounting bracket inside the microphone compartment as shown in Figure 3. Attach the instructional label below (provided) on to the inner surface of the microphone compartment door. NOTE: The microphone gets activated two seconds after depressing the microphone switch. Figure 3. Installing the Local Paging Microphone, D Rail Terminal Block and Emergency Phone. 8. Attach the Emergency Phone to the tower with six (6) 10-24 oval head tamperproof screws (included with the phone). When using an ETP-400 Series Emergency Phone connect the phone line coming into the tower to the male RJ11 connector coming from the Emergency Phone. An outdoor rated RJ11 female modular jack on the end of the incoming phone line is strongly recommended. 9. Re-attach the rear access panels to the tower. NOTE: It is the installer s obligation to ensure compliance with all national, regional, and local regulations. ALL WIRG MUST USE DRIP-LOOPS. Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 6 of 9

IV. Wiring Installation 1. Make all connections to the D Rail Terminal Block as shown in Table 1. 2. Connect the Paging Amplifier to the WEBS Loudspeakers, D Rail Terminal Block and the WEBS- VCU as shown in Figure 4. Connect the speaker audio cables to their corresponding paging amplifier speaker output cables as follows: Speaker No. Speaker #1 Speaker #2 Speaker #3 Speaker #4 Amplifier Cable White and White/Black Grey and Grey/Black Green and Green/Black Purple and Purple/Black To Speaker Cables { [GREY] [PURPLE] Power - [RED] Power - Trigger [ORANGE] [RED or WHITE] [ORANGE- WHITE] POWER CABLE TRIGGER CABLE RED [ORANGE- WHITE] 55 50 37 36 }To D Rail Terminal Block Output Power Connections PAGG AMPLIFIER Input RCA Cable 1 RCA Cable 2 RCA Cable 3 RCA Cable 4 } To Output on WEBS-VCU Figure 4. Paging Amplifier, WEBS Loudspeakers, WEBS-VCU and D Rail Terminal Block Connectivity Layout Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 7 of 9

3. Connect the WEBS-VCU and the D Rail Terminal Block as shown in Figure 5. If using the IP paging module (WEBS-CM-2 or VOIP-500 Series Emergency Phone), connect the respective wires to the WEBS-CM-2 Input port on the WEBS-VCU. If using the analog paging module (WEBS-ZPS) connect the respective wires to the WEBS-ZPS Input port on the WEBS-VCU. The unused cable wires should be individually insulated from each other. To D Rail Terminal Block { 38 39 40 41 [RED] { To D Rail Terminal Block 42 43 44 45 46 [RED] [YELLOW] BARE SHIELD Microphone Input WEBS-CM-2 / WEBS-ZPS Input WEBS-VCU Power / Trigger Output 1 Output 2 Output 3 Output 4 } RCA CABLE 1 RCA CABLE 2 RCA CABLE 3 RCA CABLE 4 Paging Amplifier [ GREEN] 52 [BROWN] 54 Figure 5. WEBS-VCU, Paging Amplifier and D Rail Terminal Block Connectivity Layout 4. When using WEBS-CM-2 or VOIP-500 Series Emergency Phone make connections to the D Rail Terminal Block as shown in Figure 6. VOIP-500 / WEBS-CM-2 Output [BROWN] Auxiliary Output [Dry Contact Closure] [GRAY] [GRAY/BLACK] Line Level Twisted Shielded Pair Cable Twisted One Pair Shielded And One Pair Unshielded Cable [GRAY] 13 [GRAY/BLACK] 14 [BROWN] 15 16 }To D Rail Terminal Block Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 8 of 9

Figure 6. VOIP-500 / WEBS-CM-2 and D Rail Terminal Block Connectivity Layout 5. When using the WEBS-ZPS make connections to the D Rail Terminal Block as shown in Figure 7. MODEL WEBS- ZPS 22 AWG wire PA LPBGM LOCAL BGM LOCAL BGM LOCAL BGM BGM SRC OUT PA ZONE A ZONE A ZONE A NC COM NO NC COM RLY ONE RLY ONE HPBGM EM/SC GND AUX GND ZONE B ZONE C RD A RD B ZONE B ZONE C RD A RD B ZONE B ZONE C RD A RD B NO +12 VDC RD C RD C RD C GND ST -1.5 A RD COM RD COM RD COM 13 [RED] [YELLOW] Bare Shield [RED] [YELLOW] Bare Shield 14 15 16 17 }To D Rail Terminal Block One Pair Twisted Shielded with Bare Wire One Pair Unshielded Figure 7. WEBS-ZPS and D Rail Terminal Block Connectivity Layout Copyright 2014 Talk-A-Phone Co. All rights reserved. Page 9 of 9