Kinetix 300 Drive (single-phase and three-phase) Power Specifications

Similar documents
Kinetix 300 and Kinetix 350 EtherNet/IP Servo Drives

Kinetix 6000 Integrated Axis Modules

Use this table to size an enclosure and calculate required ventilation for your Kinetix 5500 drive system.

Kinetix 6000 Multi-axis Servo Drives

Open Type Without Enclosure

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

200 Watt Passive Shunt Module

Open Type Without Enclosure

PowerFlex 400 Submittal

IMC-316P Hardware Manual for model IMC-316P-X-D

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

High Frequency Sinewave Guardian TM Filter

Design Characteristics. FlexDrive II. Series

NEMA Contactor and Starter Specifications

3Specifications CHAPTER THREE IN THIS CHAPTER

Integrated servo motor

High Frequency SineWave Guardian TM Filter

3 - Protection components Circuit-breakers

ACH550 HVAC Drive Submittal

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Switching Power Supply Type SPP1 60W Enclosed type

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

StatiVolt. Inverter UPS Systems. Features. Contents

Solid-state Contactor Specifications

Deploying Current Transformers in Applications Greater Than 200 A

How to Choose Power Supplies

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

STANDARD ELECTRIC LINEAR SERVOACTUATION PACKAGES

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Non-Spring Return DuraDrive Modulating Actuator

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Power Supplies 3. SDN-C Compact DIN Rail Series

Spring Return DuraDrive Proportional Actuator

Please use the Q & A utility to ask us any questions concerning the material being presented.

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Modular equipment. Presentation, standards. Standard contactors TeSys GC

1394 External Shunt Resistor Kit

LFWLP W 12V 15.00A 25.00A 92%

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

PKS-PRO-AEA-EC-08-JP22

(1,5 modules per pole)

PKS-PRO-AEA-EC-02-JP22

REDUNDANT AC 300W POWER SUPPLY. Technical Specifications TD-AC-300W-MAX

PKS-PRO-AEA-EC-30-GP22

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

Harmonic Drive Actuator. D C S e r v o S y s t e m s. P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l. RH Mini Series RHS and RFS Series

New Servo Concept: Junma

RH Mini Series. Total Motion Control. Harmonic Drive acutator

The motors are described by the following numbering system: D 500 ppr encoder 1 E 1,000 ppr encoder 1 H Hall-effect only R resolver

AC Drive Technology. An Overview for the Converting Industry. Siemens Industry, Inc All rights reserved.

Maintain feedback power during a safety stop or e-stop to minimize the recovery time. Resynchronization might be required.

Inverter MICROMASTER 410

PKS-PRO-AEA-EC-20-GP22

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

847H. Description. Features. Specifications

IMCjr Hardware Manual for models IMJ-307_-X-D IMJ-31L_-4-D. Pub 330R6. A publication of

CONTENTS XV300K GB r doc XV300K 2/13

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

5320A. Multifunction Electrical Tester Calibrator. Extended Specifications

1715 Redundant I/O System Specifications

IRT AT-Small. Technical Manual. quality IN MOTION. quality IN MOTION

Installation requirements

TE W Single Output External Power Test & Measurement/Industrial Series

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

SX (400 V) System configuration

Technical Data Sheets

System overview. *Safety PLC according to IEC 61508:1998 and EN ISO 13849:2006. Logic Motion Controller C-based

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

8V General information. 2 Order data 8V

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

Phoenix DX Clean Power (18 Pulse) AC Drive

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

VarioTrane TR1. Series 2800 TR1-PRC002-E4

1715 Redundant I/O System Specifications

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

TE60 60W Single Output External Power Test & Measurement/Industrial Series

MCTS II Multi Channel Current Transducer System. Installation Manual

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Smart Power Relay E I...

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Transcription:

Chapter 4 Kinetix 3 EtherNet/IP Indexing Servo Drives Kinetix 3 Drive (single-phase and three-phase) Power Specifications Attribute 297-V33PR1 297-V33PR3 297-V33PR5 297-V33PR6 AC input voltage AC input frequency Main AC input current (1) Nom (rms) 12V input Max inrush (-pk) 12V input Nom (rms) 24V input Max inrush (-pk) 24V input 12/24V rms single-phase or three-phase 48 62 Hz 5. A 136 A 3.A 136 A 8.6 A 2.3 A 5.A 2.3 A (1) Kinetix 3 drive modules are limited to 1 AC mains power cycling per minute. 15. A 2.3 A 8.7A 2.3 A Integrated AC line filter No No No No Control power back-up input voltage Control power back-up input current Nom Max inrush (-pk) 2 26V DC 5 ma 3 A 24. A 11.3 A 13.9 A 11.3 A Continuous output current (rms) 2. A 4. A 8. A 12. A Continuous output current (-pk) 2.8 A 5.7 A 11.3 A 17. A Peak output current (rms) (2) (2) Peak RMS current allowed for up to 2 seconds with a 5% duty cycle. 6. A 12. A 24. A 36. A Peak output current (-pk) 8.5 A 17. A 33.9 A 5.9 A Continuous power output.5 kw 1. kw 2. kw 3. kw Shunt On Shunt Off Overvoltage Short circuit current rating 39 V DC 375V DC 43V DC 1, A (rms) symmetrical 234 Publication GMC-SG1O-EN-P March 21

Kinetix 3 EtherNet/IP Indexing Servo Drives Chapter 4 AC Line Filters The Kinetix 3 drives were tested by using recommended line filters. Use of these filters is also needed to meet CE requirements. 297-V32PR, 297-V32PR2, 297-V32PR4 drives have integrated AC line filters. AC Line Filter Dimensions Kinetix 3 Drive Dimensions are in mm (in.) This connector ships prewired to the AC line filter. 297-F1 and 297-F2 side-mount line filters add 35.8 mm (1.41 in.) to the width of your drive. 3 15 (5.9) 297-F1 or 297-F2 Side Mount AC Line Filters 35.8 (1.41) 166 (6.52) 297-F4, 297-F5, and 297-F6 rear-mount line filters add 48 mm (1.89 in.) to the depth of your drive. 48. (1.89) 4.1 (.16) Ø 4.6 (.18) 211 (8.31) 219 (8.62) 15.2 (.6) Dimensions are in mm (in.) 68.6 (2.7) 297-F4, 297-F5, or 297-F6 Rear Mount AC Line Filters 4.6 (.18) 38.1 (1.5) AC Line Filter Specifications This connector ships prewired to the AC line filter. Kinetix 3 Drive 48. (1.89) AC Line Filter Mount Voltage 5/6 Hz Phase Current A @ 4 C (14 F) Power Loss W 297-F1 12/24V AC 1 or 3 24. 5.2 9. Side 297-F2 48V AC 3 1. 2.8 Leakage Current ma Weight, approx. kg (lb).6 (.13) (1) Use 29-XXLF-TC116 line filter for 297-V31PR and 297-V31PR2 drives. Refer to AC Line Filter Specifications on page 463 for more information. (2) This filter is rated for multiple voltage/phase line conditions. Kinetix 3 Drive (1) 297-V33PR6 297-V34PR6 12/24V AC 1 or 3 297-V33PR1 297-F4 (2) 4.4 1.2 297-V34PR3 48V AC 3 1. Rear.8 (.18) 297-V34PR5 297-F5 (2) 6.9 1.3 297-V33PR3 12/24V AC 1 or 3 297-F6 (2) 15. 4.1 297-V33PR5 Publication GMC-SG1O-EN-P March 21 237

Chapter 4 Kinetix 3 EtherNet/IP Indexing Servo Drives Shunt Resistor Specifications The Bulletin 297 passive shunt resistor wires directly to the Kinetix 3 drive. Shunt Resistor Dimensions Dimensions are in mm (in.) 5 (19.68) Flying Leads 2.5 mm 2 (14 AWG) 12. (.47 4.3 (.17) 1. (.39 Shunt Resistor L1 L2 L3 297-R2 21 (8.3) 197 (7.7) 17 (6.7) L2 L1 L3 297-R3 21 (8.3) 197 (7.7) 17 (6.7) 297-R4 15 (5.9) 137 (5.4) 11 (4.3) 297-R6 21 (8.3) 197 (7.7) 17 (6.7) 297-R7 15 (5.9) 137 (5.4) 11 (4.3) 1. (.39 12. (.47 41. (1.6) Shunt Resistor Power Specifications Shunt Module Resistance Ω Continuous Power W Peak Power kw Specifications Peak Current A D_Application, Max (1) % Weight kg (lb) Kinetix 3 Drive 297-R2 2 7.6 19.5 1.97 297-V32PR4 15.3 (.7) 297-V33PR5 297-R3 3 5.1 13. 2.96 297-V33PR6 297-R4 4 8 3.8 9.8 2.1.2 (.4) 297-R6 75 15 7.9 1.3 1.9.3 (.7) 297-V31PR 297-V31PR2 297-V32PR 297-V32PR2 297-V33PR1 297-V33PR3 297-V34PR5 297-V34PR6 297-R7 15 8 4. 5.1 2.2.2 (.4) 297-V34PR3 (1) D_Application is the application duty cycle in percent. For the intermittent regeneration applications, use D_Application = t/t, where t is the duration when regeneration is needed and T is the time interval between two regenerations. Both t and T must use the same time units, for example, seconds. 238 Publication GMC-SG1O-EN-P March 21

Kinetix 3 EtherNet/IP Indexing Servo Drives Chapter 4 Kinetix 3 General System Specifications This section contains environmental, weight, power dissipation, circuit breaker/fuse, transformer, and contactor specifications. Also included are maximum feedback cable length specifications and dimensions for mounting your Kinetix 3 drive. Environmental Specifications Attribute Operational Range Storage Range (nonoperating) Ambient temperature 4 C (32 14 F) -1 7 C (14 158 F) Relative humidity 5 95% noncondensing 5 95% noncondensing Altitude De-rate by 1% per 3 m (1 ft) above 15 m (5 ft) 3 m (9842 ft) during transport Vibration 5 2 Hz @ 2.5 g peak,.15 mm (.6 in.) maximum displacement Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions) Weight Specifications Drive Weight, approx. kg (lb) Drive 297-V31PRO 1.3 (2.9) 297-V33PR3 1.5 (3.3) 297-V31PR2 1.5 (3.3) 297-V33PR5 2. (4.4) 297-V32PRO 1.4 (3.1) 297-V33PR6 1.9 (4.2) 297-V32PR2 1.7 (3.7) 297-V34PR3 1.5 (3.3) 297-V32PR4 2.2 (4.9) 297-V34PR5 2. (4.4) 297-V33PR1 1.3 (2.9) 297-V34PR6 1.8 (4.) Weight, approx. kg (lb) Power Dissipation Specifications Use this table to size an enclosure and calculate required ventilation for your Kinetix 3 drive system. Drive Loss, Max W Drive 297-V31PRO 28 297-V33PR3 39 297-V31PR2 39 297-V33PR5 67 297-V32PRO 28 297-V33PR6 117 297-V32PR2 39 297-V34PR3 39 297-V32PR4 67 297-V34PR5 58 297-V33PR1 28 297-V34PR6 99 Loss, Max W Publication GMC-SG1O-EN-P March 21 239

Chapter 4 Kinetix 3 EtherNet/IP Indexing Servo Drives Circuit Breaker/Fuse Specifications While circuit breakers offer some convenience, there are limitations for their use. Circuit breakers do not handle high current inrush as well as fuses. Make sure the selected components are properly coordinated and meet acceptable codes including any requirements for branch circuit protection. Evaluation of the short-circuit available current is critical and must be kept below the short-circuit current rating of the circuit breaker. Use class CC or T fast-acting current-limiting type fuses, 2, AIC, preferred. Use Bussman KTK-R, JJN, JJS or equivalent. Thermal-magnetic type breakers preferred. The following fuse examples and Allen-Bradley circuit breakers are recommended for use with Kinetix 3 drives. Fuse and Circuit Breaker Specifications Drive 297-V31PR 297-V31PR2 297-V32PR 297-V32PR2 Bussman Fuse Mains VAC Allen Bradley Circuit Breaker (1) Disconnect (2) Magnetic Contactor (3) KTK-R-2 (2 A) 1492-SP3D3 14M-F8T-C32 297-V32PR4 LPJ-45SP (45 A) 1492-SP3D4 14M-F8E-C45 297-V33PR1 297-V33PR3 297-V33PR5 KTK-R-2 (2 A) 1492-SP3D3 14M-D8T-C2 297-V33PR6 KTK-R-3 (3 A) N/A 14U-F8T-C32 297-V34PR3 297-V34PR5 297-V34PR6 KTK-R-2 (2 A) 1492-SP3D4 14M-F8T-C32 (1) When using Bulletin 1492 circuit protection devices, the maximum short circuit current available from the source is limited to 5 A. (2) Use fully-rated short-circuit protection circuit breaker for device branch circuit protection only when there is an upstream fully-rated breaker. (3) Fully-rated breaker for overload current and short circuit rating. 24 Publication GMC-SG1O-EN-P March 21

Kinetix 3 EtherNet/IP Indexing Servo Drives Chapter 4 Contactor Ratings This table lists the recommended contactor ratings for Kinetix 3 Drive. Kinetix 3 Drive (12/24V) 297-V31PR 297-V31PR2 Kinetix 3 Drive (24V) 297-V32PR 297-V32PR2 297-V32PR4 297-V33PR1 297-V33PR3 297-V33PR5 297-V33PR6 Kinetix 3 Drive (48V) 297-V34PR3 297-V34PR5 297-V34PR6 Contactor 1-C3x1 (AC coil) 1-C3Zx1 (DC coil) 1-C3x1 (AC coil) 1-C3Zx1 (DC coil) 1-C37x1 (AC coil) 1-C23Zx1 (DC coil) 1-C23x1 (AC coil) 1-C23Zx1 (DC coil) 1-C3x1 (AC coil) 1-C3x1 (DC coil) 1-C37x1 (AC coil) 1-C23Zx1 (DC coil) Transformer Specifications for Control Input Power Attribute Input volt-amperes Input voltage Output voltage Value (46V system) 75VA 46V AC 12 24V AC Publication GMC-SG1O-EN-P March 21 241

Kinetix 3 EtherNet/IP Indexing Servo Drives Chapter 4 Kinetix 3 Drive Dimensions Dimensions are in mm (in.) 7.1 (.28) 3.8 (1.2) Ø 4.57 (.18) Kinetix 3 Drive (297-V31PR is shown) 182.4 (7.18) 19.5 (7.5) 6.6 (.26) 11.8 (.46) 38.1 (1.5) 4.57 (.18) A B A mm (in.) B mm (in.) A mm (in.) B mm (in.) 297-V31PR 185.1 (7.29) 68. (2.68) 297-V33PR3 185.1 (7.29) 68.5 (2.7) 297-V31PR2 185.1 (7.29) 68.5 (2.7) 297-V33PR5 185.1 (7.29) 94.4 (3.72) 297-V32PR 229.6 (9.4) 68. (2.68) 297-V33PR6 229.6 (9.4) 68. (2.68) 297-V32PR2 229.6 (9.4) 68.5 (2.7) 297-V34PR3 185.1 (7.29) 68.5 (2.7) 297-V32PR4 229.6 (9.4) 86.8 (3.42) 297-V34PR5 185.1 (7.29) 94.4 (3.72) 297-V33PR1 185.1 (7.29) 68. (2.68) 297-V34PR6 229.6 (9.4) 68. (2.68) Publication GMC-SG1O-EN-P March 21 243

Rotary Motion System Combinations Chapter 13 Bulletin MPL Motor Performance Specifications with Kinetix 3 (24V) Drives Rotary Motor Max Speed rpm System Continuous Stall Current A -pk System Continuous Stall N m System Peak Stall Current A -pk System Peak Stall N m Motor Rated Output kw Kinetix 3 24V Drives MPL-A151V 8 1.5.26 (2.3) 3.4.77 (6.8).16 297-V33PR1 MPL-A152U 7 1.8.49 (4.3) 6.1 1.58 (13.9).27 297-V33PR1 MPL-A153U 7 2.82.9 (8.) 1.1 2.82 (24.9).39 297-V33PR3 MPL-A21V 8 3.9.55 (4.8) 1.2 1.52 (13.5).37 297-V33PR3 MPL-A22T 6 4.54 1.61 (14.2) 15.5 4.74 (41.9).62 297-V33PR3 MPL-A23P 5 5.4 2.1 (18) 23. 8.2 (72.5).86 297-V33PR5 MPL-A31F 3 3.2 1.58 (14) 9.3 3.61 (32).46 297-V33PR3 MPL-A31P 5 4.85 1.58 (14) 14 3.61 (32).73 297-V33PR3 MPL-A32H 35 6.1 3.5 (27) 19.3 7.91 (7) 1. 297-V33PR5 MPL-A32P 5 9. 3.5 (27) 29.5 7.91 (7) 1.3 297-V33PR5 MPL-A33P 5 12. 4.18 (37) 38 11.1 (98) 1.8 297-V33PR6 MPL-A42P 5 12.7 4.74 (42) 46 13.5 (12) 2. 297-V33PR6 MPL-A43H 35 12.2 6.21 (55) 45 19.8 (175) 1.8 297-V33PR6 MPL-A43P 5 16.8 5.99 (53) 51 15.7 (139) 2.2 297-V33PR6 MPL-A453F 28 13.4 8.36 (74) 42 2.3 (18) 1.9 297-V33PR6 MPL-A454C 15 9.4 1.2 (9) 29 27.1 (24) 1.5 297-V33PR6 Performance specification data and curves reflect nominal system performance of a typical system with motor at 4 C (14 F) and drive at 4 C (14 F) ambient, and rated line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later. Publication GMC-SG1O-EN-P March 21 493

Chapter 13 Rotary Motion System Combinations Kinetix 3 (24V) Drives/MP-Series Low Inertia Motor Curves.8.7 297-V33PR1 and MPL-A151V 7.8 6.19 1.6 1.4 297-V33PR1 and MPL-A152U 14.1 12.4.6 5.31 1.2 1.6.5 4.42 1. 8.85.4 3.54.8 7.8.3 2.65.6 5.31.2 1.77.4 3.54.1.88.2 1.77 2 4 6 8 2 4 6 8 4. 3.5 297-V33PR3 and MPL-A153U 3.9 1.6 1.4 297-V33PR3 and MPL-A21V 14.1 12.4 3. 26.5 1.2 1.6 2.5 22.1 1. 8.85 2..8 7.8 1.5 13.3.6 5.31 1. 8.84.4 3.54.5 4.42.2 1.77 2 4 6 8 2 4 6 8 5. 297-V33PR3 and MPL-A22T 44.2 1. 297-V33PR5 and MPL-A23P 88.5 4. 8. 7.8 3. 26.5 6. 53.1 2. 4. 1. 8.85 2. 1.77 1 2 3 4 5 6 = Intermittent operating region = Continuous operating region 1 2 3 4 5 494 Publication GMC-SG1O-EN-P March 21

Rotary Motion System Combinations Chapter 13 Kinetix 3 (24V) Drives/MP-Series Low Inertia Motor Curves, Continued 4. 297-V33PR3 and MPL-A31F 4. 297-V33PR3 and MPL-A31P 3. 26.5 3. 26.5 2. 2. 1. 8.85 1. 8.85 1 2 3 1 2 3 4 5 8. 297-V33PR5 and MPL-A32H 7.8 8. 297-V33PR5 and MPL-A32P 7.8 6. 53.1 6. 53.1 4. 4. 2. 2. 1 2 3 4 1 2 3 4 5 12. 1. 8. 297-V33PR6 and MPL-A33P 16 88.5 7.8 16. 12. 297-V33PR6 and MPL-A42P 141 16 6. 53.1 8. 7.8 4. 2. 4. 1 2 3 4 5 = Intermittent operating region = Continuous operating region 1 2 3 4 5 Publication GMC-SG1O-EN-P March 21 495

Rotary Motion System Combinations Chapter 13 Kinetix 3 (48V) Drives/MP-Series Medium Inertia Motor Curves, Continued 297-V34PR6 and MPM-B134C 28. 248 24. 212 2. 16. 12. 8. 4. 177 142 16 7.8 5 1 15 2 25 3 = Intermittent operating region = Continuous operating region = Drive operation with 4V AC (rms) input voltage Kinetix 3 (24V) Drives with MP-Series Food Grade Motors This section provides system combination information for the Kinetix 3 (24V) drives when matched with MP-Series food-grade motors. Included are motor power/brake and feedback cable catalog numbers, system performance specifications, and the optimum torque/speed curves. Bulletin MPF Motor Cable Combinations Motor (2V class) Motor Power Cable Motor Feedback Cable (1) MPF-A31P, MPF-A32H, MPF-A32P, MPF-A33P MPF-A43H 29-XXNPMF-16Sxx (2) (1) Use low-profile connector kit (catalog number 29-K2CK-D15M) or panel-mounted breakout components on drive end. Refer to Breakout Components and Connector Kits beginning on page 418. (2) These cables are available as standard (catalog number 29-XXNPMF-xxSxx) or continuous-flex (catalog number 29-CPxM7DF-xxAFxx). (3) These cables are available as standard (catalog number 29-XXNFMF-Sxx) or continuous-flex (catalog number 29-CFBM7DF-CDAFxx). 29-XXNFMF-Sxx (3) Absolute High-resolution Feedback Motor-end connector kits are available for motor power/brake and feedback cables. Refer to Motor-end Connector Kits on page 411 for catalog numbers. Cable length xx is in meters. Refer to Standard Cable Lengths beginning on page 393. Bulletin MPF Motor Performance Specifications with Kinetix 3 (24V) Drives Rotary Motor Max Speed rpm System Continuous Stall Current A -pk System Continuous Stall N m System Peak Stall Current A -pk System Peak Stall N m Motor Rated Output kw Kinetix 3 24V Drives MPF-A31P 5 4.85 1.58 (14) 14 3.61 (32).73 297-V33PR3 MPF-A32H 35 6.1 3.5 (27) 19.3 7.91 (7) 1. 297-V33PR5 MPF-A32P 5 9. 3.5 (27) 29.5 7.91 (7) 1.3 297-V33PR3 MPF-A33P 5 12. 4.18 (37) 38 11.1 (98) 1.6 297-V33PR6 MPF-A43H 35 12.2 6.21 (55) 45 19.8 (175) 1.8 297-V33PR6 Performance specification data and curves reflect nominal system performance of a typical system with motor at 4 C (14 F) and drive at 4 C (14 F) ambient, and rated line voltage. For additional information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later. Publication GMC-SG1O-EN-P March 21 53