Automotive EMI/EMC Pre-compliance Tests

Similar documents
Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

KickStart Instrument Control Software Datasheet

Isolation Addresses Common Sources of Differential Measurement Error

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

Measuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

High-voltage Differential Probes

20X Low Capacitance Probe P6158 Datasheet

Using the Ramp Rate Method for Making Quasistatic C-V Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

Stress Calibration for Jitter >1UI A Practical Method

Power Measurement and Analysis Software

Low Cost RF Sensors. application note

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer APPLICATION NOTE

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

30 A AC/DC Current Probe TCP0030A Datasheet

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

1.5 GHz Active Probe TAP1500 Datasheet

Passive Voltage Probes

Using the 4200A-CVIV Multi-Switch to Make High Voltage and High Current C-V Measurements APPLICATION NOTE

Measuring Wireless Power Charging Systems for Portable Electronics

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

S540 Power Semiconductor Test System Datasheet

10 GHz Linear Amplifier PSPL5866 Datasheet

Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope

Measurement Statistics, Histograms and Trend Plot Analysis Modes

AC Current Probes CT1 CT2 CT6 Data Sheet

Measuring Power Supply Switching Loss with an Oscilloscope

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

AC/DC Current Probe TCP0150 Datasheet

Low Capacitance Probes Minimize Impact on Circuit Operation

Soldering a P7500 to a Nexus DDR Component Interposer

Switching Between C-V and I-V Measurements Using the 4200A-CVIV Multi-Switch and 4200A-SCS Parameter Analyzer APPLICATION NOTE

S540 Power Semiconductor Test System Datasheet

P7500 Series Probes Tip Selection, Rework and Soldering Guide

TriMode Probe Family P7700 Series TriMode Probes

Active Power Factor Correction Verification Measurements with an Oscilloscope APPLICATION NOTE

High-impedance Buffer Amplifier System

Be Sure to Capture the Complete Picture

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Differential Probes P6248 P6247 P6246 Datasheet

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Time and Frequency Measurements for Oscillator Manufacturers

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Advanced Test Equipment Rentals ATEC (2832)

100GBASE-KR4/CR4 & CAUI-4 Compliance and Characterization Solution

12.5 Gb/s Driver Amplifier PSPL5865 Datasheet

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet

Z-Active Differential Probe Family P7313 P7380A P7360A P7340A Datasheet

e-guide to RF Signals UNLICENSED & ISM BANDS LAND MOBILE & PUBLIC SAFETY CELLULAR AERONAUTICAL RADIO & TELEVISION BROADCAST WEATHER RADAR

Visual Triggering. Technical Brief

Replicating Real World Signals with an Arbitrary/Function Generator

Introduction to VNA Basics PRIMER

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

Essential Capabilities of EMI Receivers. Application Note

Basics of Using the NetTek YBA250

Tektronix Logic Analyzer Probes P6800/P6900 Series Datasheet

100GBASE-KR4, 100GBASE-CR4, & CAUI-4 Compliance and Characterization Solution for Real Time Scopes

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

10GBASE-KR/KR4 Compliance and Debug Solution

Fundamentals of AC Power Measurements

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Notice to EU customers

DPO7OE1 33 GHz Optical Probe

AC/DC Current Measurement Systems

Programmable Pulse/Pattern Generator PSPL1P601 and PSPL1P602 Datasheet

GENERAL PURPOSE POWER SUPPLIES, SPECIAL PURPOSE POWER SUPPLIES, AND ELECTRONIC LOADS SELECTOR GUIDE

TriMode Probe Family. P7500 Series Data Sheet. Features & Benefits. Applications

P7600 Series TriMode Probes

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

30 Gb/s and 32 Gb/s Programmable Pattern Generator PPG Series Datasheet

Passive High Voltage Probes P5100 P5102 P5120 P6015A

TriMode Probe Family. P7500 Series Datasheet. Features & Benefits. Applications

16 Gb/s, 30 Gb/s Gb/s, and 32 Gb/s Programmable PatternPro Pattern Generator PPG PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies N6141A & W6141A EMI X-Series Measurement Application. Technical Overview

How to Troubleshoot System Problems Using an Oscilloscope with I 2 C and SPI Decoding

van der Pauw and Hall Voltage Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

Arbitrary/Function Generator AFG1000 Series Datasheet

Characterize Phase-Locked Loop Systems Using Real Time Oscilloscopes

Evaluating and Optimizing Radio Frequency Identification (RFID) Systems Using Real-Time Spectrum Analysis

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Performing Cyclic Voltammetry Measurements Using Model 2450-EC or 2460-EC Electrochemistry Lab System

Arbitrary Function Generator AFG1022 Datasheet

AC/DC Current Measurement Systems

Transcription:

Automotive EMI/EMC Pre-compliance Tests

Introduction Electromagnetic interference (EMI) regulations are in place throughout the world to provide improved reliability and safety for users of electrical and electronic equipment. The automotive industry and individual automobile manufacturers are required to meet EMI standards specifically for automotive systems. With the introduction of USB-based real-time spectrum analyzers, pre-compliance EMI testing has become significantly easier and more cost-effective for designers. This application note provides an overview of measurement regulations and EMI pre-compliance procedures. Test setups for both radiated and conducted emissions are shown using the Tektronix RSA306B with EMCVu software. EMI Pre-compliance testing Most engineers employ good design practices to minimize the potential for EMI problems. Still, to identify and address any potential EMI issues before formal compliance testing, it is considered best practice to perform in-house pre-compliance measurements during the design and prototyping stages. This reduces the risk that the product will fail final compliance tests at the test house. Also, in the event of a failure during formal testing, the ability to test in your own lab gives you the time to methodically isolate problem areas and test different corrections. AUTOMOTIVE ELECTROMAGNETIC COMPATIBILITY STANDARDS CISPR 12 and CISPR 25 are international standards containing procedures and requirements for the measurement of radio disturbances to protect off-board receivers and on-board receivers of automotive, respectively. CISPR 12 is a whole vehicle test rather than applying to subassemblies. The goal is to assure that receivers are not affected when the vehicle drives them. The test frequency range is usually from 30 MHz to 1 GHz. Only radiated tests are required. CISPR 25 measures the RF interference that is generated by the vehicle and then picked up by vehicle mounted antennas (such as the AM/FM radio or GPS antenna). The test frequency bands are the operating bands of selected wireless standards (FM and TV broadcasting, cellular service, ). In addition to CISPR 12 and CISPR 25, most manufacturers have their own set of standards to augment the CISPR guidelines. For example, Ford Motor Company has their own Electromagnetic Compatibility Specification for Electrical/ Electronic Components and Subsystems (FMC1278). Other OEMs have similar standards. Tektronix EMCVu pre-compliance software supports EMC standards including CISPR, FCC and MIL-STD for many types of devices. To automate testing, EMCVu provides a built-in standards table allowing you to choose the applicable standard for your product and the region in which it will be sold. FIGURE 1. Affordable pre-compliance testing can easily be set up to uncover potential problems so that you can minimize test time in more expensive compliance test facilities. FIGURE 2. EMI standard presets. 2 TEK.COM

SELECTING ACCESSIORES Selecting accessories is one of the keys for EMI compliance tests. It is not unusual for the cost of accessories to exceed the cost of the spectrum analyzer itself. The required accessories depend on the type of emission testing being performed. To help manage costs, there are low-cost accessories available. For example, the measurements shown Figure 1 are being made with a very low-cost PC board log periodic antenna. One or two of these, along with a biconical antenna can often cover the required frequency range. The biconical antenna is used for 20 to 200 MHz frequencies, since the longer wavelengths require a larger antenna. In this example the antennas were mounted on an inexpensive tripod. Antenna Factors (AF) and cable loss can be input into the spectrum analyzer software for field strength correction. FIGURE 3. Tektronix accessories for EMI pre-compliance tests. To achieve better measurement accuracy and avoid accessory mismatches, Tektronix offers fully-validated accessories including antennas, Line Impedance Stabilization Networks (LISN) and pre-amplifiers. You can purchase accessories individually, or in comprehensive accessory bundles for conducted and radiated tests. Characterization of accessories including gain and loss values are pre-loaded into EMCVu to provide simple set-up and greater measurement accuracy. Measurements are corrected by negating the combined impact of all the accessories gains and losses. FIGURE 4. Tektronix near field probe set for trouble shooting. TEK.COM 3

FIGURE 5. Accessory setup wizard in EMCVu. BETTER UNDERSTAND THE TEST ENVIRONMENT WITH AN AMBIENT SCAN Most designers do not have access to a dedicated anechoic chamber, and must adapt to using less ideal testing environments. A good testing location should be roomy, and free from powerful emitters such as Wi-Fi access points and noisy electrical equipment. Basements, unused commercial space, or parking garages may be good candidates. However, without a professionally built anechoic chamber, background noise and over-the-air broadcast signals will find their way to the front end of the spectrum analyzer and risk impacting measurements. This makes it critical to have a better understanding the RF environment and establish a baseline in order to achieve useful pre-compliance test results that approximate those expected from a test house. 4 TEK.COM

Spurs mainly from the air, because the math trace shows smaller readouts Spurs mainly from the DUT, because the math trace shows larger readouts Red: Violations of the limit line Blue: Could be from the ambience FIGURE 6. Using ambient scan and math trace (ambient minus peak scan) to separate the spurs from DUT and spurs from environment and spectrum analyzer. An Ambient scan tool in Tektronix EMCVu software helps establish an ambient EMI baseline by capturing emissions caused by environment or equipment. Before an ambient scan is done, the DUT (device under test) must be switched off, or completely removed from the setup. After performing an ambient scan with the DUT turned off, and then performing a scan with the DUT activated, a math trace can be used to observe the difference between the ambient signals and the spurs from the DUT. CONDUCT A QUICK SCAN WITH PEAK DETECTORS The quasi-peak detector specified in many EMI standards takes significant time to scan over wide frequency ranges. To save time, you can perform a quick scan using a peak detector, instead of a quasi-peak detector. The scan using the peak detector will give a set of worst case measurements, and you can perform quasi-peak measurements to dig deeper into outof-limit conditions. The example in Figure 6 shows a CISPR 25 radiated emission test. After the recalling the standard preset, EMCVu displays a peak scan with the trace with yellow color. The magenta trace is the ambient scan measured when the DUT is turned off. The pink trace is the math trace presents the difference between the ambient and peak scan. From the math trace, it is easy to tell the spur #1 is from the environment, because peak scan and ambient scan have almost the same value. The spur #2, #3, and #6 are likely from the DUT, because the math trace indicates the ambient scan is little compared to the peak scan. In the emission results table, the spots with ambient effects are flagged in blue. TEK.COM 5

RE-MEASURE OVERLIMIT SPOTS WITH CISPR QUASI-PEAK DETECTOR Once you have identified potential trouble areas within the spectrum, you can apply long dwell time detectors, such as quasi-peak, to only those frequencies that have exceeded limits. EMCVu offers three measurement methods for most standards Pre-scan + Manual Spot - A quick pre-scan followed by choosing spots from the results table and re-measuring them with detectors recommended by the standard (or those of your choice). Pre-scan + Auto Spot - A pre-scan followed by an automated re-measurement for a chosen number of spots fail the test criteria. The maximum number spots can be set for re-measurement. Complete Scan - A complete scan with detectors recommended by the standard this could be time consuming if detectors such as CISPR Quasi Peak or CISPR Avg are chosen. FIGURE 7. Three measurement methods in EMCVu. Remeasured results with CISPR Quasi peak and average detector Remeasured results with CISPR PK, QPK, and AVG FIGURE 8. Re-measure the selected over limit spurs with CISPR quasi-peak and average detectors. 6 TEK.COM

FIGURE 9. Complete report preview and generation. GENERATING A TEST REPORT After taking pre-compliance measurements, the results must be recorded and documented for future use. Creating a report similar to the certification lab report may help you discover potential issues and gain confidence before the formal certification tests. Whereas making notes on a general-purpose spectrum analyzer may be challenging, PC-based test and analysis software simplifies the report generation process. A report wizard in EMCVu simplifies report generation by allowing you to specify the information to include in the report, and allowing you to merge multiple test results. Reports may be output in several formats, including PDF, MHT, XLSX and several image formats. FIGURE 10. Report Generation wizard. TEK.COM 7

Troubleshooting and debugging with real-time spectrum analysis technology Once issues have been found in pre-compliance tests, what s next? You need to troubleshoot the issues and locate the sources of RF emissions. The real-time DPX technology in Tektronix spectrum analyzers can help you to discover the most difficult, hard-to-find problems. It enables you to see RF characteristics that are practically invisible to a conventional spectrum analyzer. Figure 11 shows a near-field probe being used to locate emission sources in the near-field. Figure 12 shows both the DPX spectrum and the regular spectrum displays. The DPX spectrum indicates regularly occurring spurs, even though they are hidden below wideband noise. FIGURE 11. The DPX real time spectrum analysis with a near filed probe helps you discover and locate the transient emission sources. Low power spurs under wideband noise FIGURE 12. The DPX real time spectrum analysis vs regular swept spectrum analysis. DPX can detect transient signals, and helps users to gain insights of co-channel interference. 8 TEK.COM

Summary EMI compliance testing for automotive components and subsystems is an important part of the design process, and it usually occurs quite late. Pre-compliance testing can take help mitigate stress on your project and by taking the right steps, you can have higher confidence that your design will pass at the test house. New, relatively low-cost instruments and software are available to help you minimize testing expense and achieve schedule commitments while getting your products EMI certified. TEK.COM 9

Contact Information: Australia* 1 800 709 465 Austria 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3086 Luxembourg +41 52 675 3777 Malaysia 1 800 22 55835 Mexico, Central/South America and Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 New Zealand 0800 800 238 Norway 800 16098 People s Republic of China 400 820 5835 Philippines 1 800 1601 0077 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +82 2 6917 5000 Russia / CIS +7 (495) 6647564 Singapore 800 6011 473 South Africa +41 52 675 3777 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886 (2) 2656 6688 Thailand 1 800 011 931 United Kingdom / Ireland* 00800 2255 4835 USA 1 800 833 9200 Vietnam 12060128 * European toll-free number. If not accessible, call: +41 52 675 3777 Rev. 090617 Find more valuable resources at TEK.COM Copyright Tektronix. All rights reserved. Tektronix products are coverwed by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 09/18 EA 37W-61461-0