Downlighting Project: Location: Cat.No: Calculite LED gen " round downlight, - lm Calculite LED " generation features industry leading visual comfort, excellent uniform illumination over time, and patented installation flexibility. Complete luminaire = Frame + Engine + Trim + Accessories (optional) Type: Lamps: Notes: Qty: Frame example: CRN Series Aperture Installation Voltage / Options C C Calculite LED " aperture R R Round N New construction R Remodeler Universal V/ V (specify for Power Over Ethernet configurations) 7 V (not compatible with ELV dimming) EM Emergency, LC Chicago Plenum Engine example: CLNZU Series Lumens CRI CCT Beam Dimming Voltage CL CL Calculite LED " aperture lm lm lm lm lm lm lm CRI CRI 7 K K K K N Narrow ( ) M Medium ( ) W Wide ( ) Z - V % U Universal SOL EldoLED Solo - V.% //7 V D Dali L Lutron LDE EcoSystem (fade-to-black) E ELV (V dimming only) Universal V/ V P Power over Ethernet (PoE) E Ethernet V DC Only compatible with () to () lumen configurations. Trim example: CRDLCCP Series Aperture Style Finish Flange C R DL C Calculite LED " aperture R Round DL Downlight BK Black (matte) CL Specular clear CC CD CZ Comfort clear Comfort clear diffuse Champagne bronze White (matte) P Polished F Flangeless WH White (matte) White (matte) F Flangeless SL Non-conductive WH White (matte) Not applicable Accessories CARFT Mud-in ring for use with flangeless installations (ordered with a flangeless trim) CAEM Field installable EM pack CRVPWH IP rated vandal proof matte white accessory that mounts onto a flangeless trim AMS ActiLume multi-sensor (optional accessory for Power Over Ethernet configurations) SWZDT SpaceWise wireless controller with dwell time functionality. Emergency (EM) and Chicago Plenum (LC) options are only available with New construction (N) installations.. Emergency (EM) frame comes with emergency battery pack and ceiling mountable test switch. Reflector mounted test switch requires above ceiling access. For reflector mounted test switch, order emergency frame and add "EM" suffix to reflector (example: CRDLCCEM).. CalculiteLEDgen_in_Downlight_CRDL The lm () and lm () packages /7 are only page available of with -V (Z) dimming and have marked spacing requirements (see page ).. ELV (E) dimming is only compatible with up to lm () configurations.. SpaceWise is compatible with all -V configurations (for details see "SWZDT" spec sheet).. Non-conductive flush mount lens with pre-installed gasket (matte white non-conductive flange with diffuse lens that is flush with the flange).
CRDL Calculite LED generation " round downlight New Construction (N) Chicago Plenum (LC) in in mm mm in in mm mm in in 7 7 mm mm in in 7 7 mm mm in in mm mm in in mm mm in in 7 7 mm mm in in mm mm in in mm mm in in in mm mm mm in in in mm mm mm in in mm mm in in mm mm ø ø in in mm mm ø7 ø7 in in mm mm Ceiling Cutout ø ø in in mm mm in in mm mm Maximum ceiling in thickness 7 mm in mm 7 7in in mm mm CARFT Remodeler (R) CARFT Flangeless mud-in ring (CARFT) accessory mm CA7R h mmm in 7 mm in mm ø ø 7 in 7 in mm mm ø7 ø7 in in mm mm 7 in mm in mm in 7 in mm in mm mm in D in (max.) mm mm 7 in mm in 7 mm Detail D in mm ø in mm ø7 in mm in mm D Ceiling Cutout ø in mm in mm in mm in mm Detail Maximum D ceiling thickness 7 7in in mm mm Vandal Proof (VP) accessory in in 7 7 mm mm in in mm mm in mm CASFT Maxium Ceiling Thickness Lensed Wall Wash (LW): Ceiling in mm DCutout ø in Wall Wash ø in mm (WW, DW, CW): in mm mm in ø7 in 7 in CalculiteLEDgen_in_Downlight_CRDL mm 7 mm mm /7 page of CASFT ø 7 in mm ø7 in mm in mm in mm D in mm Detail D Detail D
CRDL Calculite LED generation " round downlight in 7 mm Narrow volts freq current Drive current power LED power THD power Power factor Light engine CL_NZU V. <% >. /Hz ma W W V. <% >. CL_NZU V. <% >. /Hz ma W W V. <% >. CL_NZU V. <% >. /Hz ma W W V. <% >. CL_NZU V. <% >. /Hz ma W W V. <% >. CL_NZU V. <% >. /Hz ma W W V. <% >. CL_NZU V. <% >. /Hz ma W W V. <% >. CL_NZU V. <% >. /Hz ma 7W W V. <% >. Medium/Wide Drive LED THD Power Light engine volts freq current current power power power factor CL_MZU V. <% >. /Hz ma W W V. <% >. CL_MZU V. in <% >. /Hz ma W Wmm V. <% >. CL_MZU V. <% >. /Hz ma W W in V.7 <% >. mm CL_MZU V. <% >. /Hz ma W W V. <% >. CL_MZU V. <% >. /Hz in ma W W V. <% >. mm in CL_MZU mm. <% >. /Hz ma W W V. <% >. CL_MZU V. <% >. /Hz ma 7W W V. <% >. ø Narrow (Power over Ethernet) Medium (Power over Ethernet) Wide (Power over Ethernet) Light engine Volts Voltage Freq Current Power CL NPE V -V DC ma. W CL NPE V -V DC ma.7 W CL NPE V -V DC ma 7.7 W CL NPE V -V DC ma. W Light engine Volts Voltage Freq Current Power CL MPE V -V DC ma. W CL MPE V -V DC ma. W CL MPE V -V DC ma.7 W CL MPE V -V DC ma. W Maxium Ceiling Light engine Thickness Volts Voltage CL WPE Lensed V Wall -V Wash (LW): CL WPE Vin mm -V Freq DC DC Current ma ma Power. W. W CL WPE Wall V Wash -V DC (WW, DW, CW): in mm ma.7 W CL WPE V -V DC ma. W ø ø. Nominal input volts.. Preferred volt range. Marked spacing applications Light engine lm lm CL_ZU series X X CL_LU series CL_DU series Modules marked with an X require marked spacing: - Center-to-center of adjacent luminaires: " (mm) - Luminaire center to side building member: " (mm) Lifetime (TM-) data Lumens Narrow beam Medium/Wide beam* lm lm lm lm L @,hrs. L @,hrs. lm* lm lm L @,hrs. L @,hrs. * Lutron lm with Medium/Wide beam is L @,hrs. CalculiteLEDgen_in_Downlight_CRDL /7 page of
CRDL Calculite LED generation " round downlight Reflector Specular clear (CL): Most specular and most efficient finish, delivers maximum photometric performance but can produce a mirror image effect of the interior space. Comfort clear (CC): Semi-specular finish that softens the light at the source of the reflector and creates a subtle, even luminance from the reflector cone. Comfort clear diffuse (CD): Slightly diffuse clear finish, that eliminates iridescence and reduces the mirror image effect inherent with specular finishes. Champagne bronze (CZ): Semispecular finish that softens light at the source of the reflector while providing a warmer reflector appearance (slightly warmer). White (WH): (matte) Brightest illuminated aperture and provides the smoothest transition to most ceilings when off (white is only available with a white flange). Black (BK): (matte) Specular finish that provides the lowest aperture brightness possible and significantly reduces source identification in a ceiling. Flange White ( ): (matte) Provides the smoothest transition to ceilings when off. Polished (P): (matches aperture) Produces a continuous look throughout the reflector (aperture matching). Flangeless (F): (flush-mount) Creates a flush, virtually seamless transition from aperture to ceiling. Frame-in-kits New Construction Galvanized stamped steel for dry or plaster ceilings. Preinstalled telescoping mounting bars from " to ". For ' distances, use /" EMT, -/" x /" U or C channel. Max ceiling thickness is -/" Patented install Mounting frame With no driver attached, this versatile frame is independent of driver accommodating a wide range of lumen packages, driver types and CCTs, including V and V inputs. Pre-installed mounting bars allow for fast and tool-less installation into T-grid and hat channel ceilings. Close-cut aperture design eliminates the possibility of undesired gap between ceiling opening and reflector flange. Separate wiring compartment for wiring frame to building allows inspection prior to light engine installation. Simple plug-and-play connection between the frame and light engine from below the ceiling eliminates the need for wiring between frame and LED driver, and also saves time during installation and future replacements/upgrades. Plug-and-play receptacle accommodates technology upgrade of light engines and replacements for the life of the building. Drivers - Advance -V % dimming - Lutron Hi-lume EcoSystem H Series % dimming - EldoLED ECOdrive Dali % dimming - EldoLED SOLOdrive -V.% dimming - ELV dimming Power over Ethernet Powered via Philips PoE lighting controller: complies with FCC rules per Title 7 part (Class A) for EMI / RFI (conducted & radiated). PoE lighting controller accessible from below ceiling. Rated life:, hrs at % lumen maintenance based on IES LM-- and TM--. Optical systems Comfort throughout the space: Patented optical system combines primary and secondary optics to provide a true physical cutoff and reflected cutoff virtually eliminating the view of the light source and bright spots in the reflector. A new reflector curve reduces reflector brightness by up to % compared to existing products, allowing for the use of higher lumen packages in smaller apertures without creating bright spots in the ceiling. Quality of light: SDCM ensures color consistency from fixture to fixture and over the luminaire s long lifetime. Proprietary optical grade silicone lens with patterned surface provides soft, even beam diffusion without hotspots or dark rings. Light Engine Quick connect power pack comprised of light source and driver allow for easy installation and replacement from below ceiling with no need for additional wiring. This allows for - Frame and ceiling installation to be performed while still finalizing details such as lumen packages, CCT and control type. - Easy replacement of electronics at end of life with minimal wasted material and labor required. - Ease and upgradability of technology. Options and Accessories Flangeless mud-in ring: Use CARFT for use with flangless plaster installations.. Sloped ceilings: Compatible with sloped ceiling adapters (see SCA spec sheet). Vandal Proof: Use CRVPWH for an IP rated vandal proof matte white accessory. Must be ordered with a flangeless trim. ENERGY STAR exceptions CRI configurations Champagne Bronze and Black finishes 7V & Emergency voltage/options Dali, EldoLED Solo & PoE drivers Title exceptions lm configurations Champagne Bronze and Black finishes Labels and Listings culus listed for wet location ENERGY STAR, RoHS & CEC Title JA certified CCEA (frames with *LC suffix) IP rated with vandal proof accessory IBEW Union made (light engines & reflectors) Warranty year warranty on complete system. Complete warranty available at: http://images.philips. com/is/content/philipsconsumer/pdfdownloads/ United%States/ODLI_-UPD-en_US- Philips-warranty-indoor-PLS-us.pdf CalculiteLEDgen_in_Downlight_CRDL /7 page of
CRDL Calculite LED generation " round downlight Narrow beam, lm Engine,. lm/w or. lm/w at.w (Power over Ethernet) Candela Curve Zonal summary Single unit data Adjustment factors Frame: CRN Engine: CLNZU Trim: CRDLCL Output lumens: watts : CRI: CCT : Spacing Crit.: Beam Angle: lms. W min K. Zone Lumens %Luminaire - - - -.%.%.%.% Angle Mean CP Lumens 7 7 7 Height to lighted plane ' 7 Beam diameter (ft)*.'..'..' * Beam diameter is where drop to % of maximum. Multiple unit data - RCR Spacing on center '....7.7 Watts per sq. ft...... x x ' Room, Workplane.' above floor, //% Reflectances Efficacy:. lm/w Report : F7 Finish CCT Lumens CL = % CC = % CD = 7% CZ = % WH = 7% BK = 7% Coefficients of utilization Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % Room Cavity Ratio 7 7 CRI K = % CRI K = % CRI K = % CRI K = % CRI K = % CRI K = % 7 7 7 7 lm = % lm = % lm = % lm = % lm = % lm = % lm = % 7 7 7 7 7 Medium beam, lm Engine,. lm/w or.7 lm/w at.w (Power over Ethernet) Candela Curve Zonal summary Single unit data Adjustment factors Frame: CRN Engine: CLMZU Trim: CRDLCL Output lumens: watts : CRI: CCT : Spacing Crit.: Beam Angle: lms. W min K. Zone Lumens %Luminaire - - - -.%.%.%.% Angle Mean CP Lumens 7 7 Height to lighted plane ' Beam diameter (ft)*.'...' 7.' * Beam diameter is where drop to % of maximum. Multiple unit data - RCR Spacing on center '.7 7.... Watts per sq. ft.....7. x x ' Room, Workplane.' above floor, //% Reflectances Efficacy:. lm/w Report : F7 Finish CCT Lumens CL = % CC = % CD = 7% CZ = % WH = 7% BK = 7% Coefficients of utilization Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % Room Cavity Ratio 7 7 CRI K = % CRI K = % CRI K = % CRI K = 7% CRI K = % CRI K = 7% 7 7 7 7 7 lm = % lm = % lm = % lm = % lm = % lm = % lm = % 7 7 7 7. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. CalculiteLEDgen_in_Downlight_CRDL /7 page of
CRDL Calculite LED generation " round downlight Wide beam, lm Engine,. lm/w or 7. lm/w at.w (Power over Ethernet) Candela Curve Zonal summary Single unit data Adjustment factors Frame: CRN Engine: CLWZU Trim: CRDLCL Output lumens: watts : CRI: CCT : Spacing Crit.: Beam Angle: 7 lms. W min K. Zone Lumens %Luminaire - - - - 7.%.%.%.% Angle Mean CP Lumens 7 7 Height to lighted plane ' Beam diameter (ft)*.'. 7... * Beam diameter is where drop to % of maximum. Multiple unit data - RCR Spacing on center '....7. Watts per sq. ft.....7. x x ' Room, Workplane.' above floor, //% Reflectances Efficacy:. lm/w Report : F7 Finish CCT Lumens CL = % CC = % CD = 7% CZ = % WH = 7% BK = 7% Coefficients of utilization Ceiling % % % % % Wall RCR Zonal cavity method - Effective floor reflectance = % Room Cavity Ratio 7 7 7 7 CRI K = % CRI K = % CRI K = % CRI K = 7% CRI K = % CRI K = 7% 7 7 7 7 lm = % lm = % lm = % lm = % lm = % lm = % lm = % 7 7 7. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C.-: Specifications for the Chromaticity of Solid State Lighting Products.. Tested using absolute photometry as specified in LM: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 7 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/luminaires CalculiteLEDgen_in_Downlight_CRDL /7 page of Philips Lighting, North America Corporation Franklin Square Drive, Somerset, NJ 7 Tel. -- Philips Lighting Canada Ltd. Hillmount Rd, Markham, ON, Canada LC S Tel. --