System SLIO nalog input modules Order number Figure Type SM 0, xbit U General information SM 0, xbit I SM 0, xbit TC SM 0, xbit U Note - - Coming soon - Features outputs, inputs, inputs, inputs, oltage 0...0 Current 0()...0 m Thermocouple Output 0...0 Current consumption/power loss Current consumption from backplane bus 0 m 0 m 00 m 0 m Power loss 0. W 0. W - 0. W Technical data analog inputs Number of inputs Cable length, shielded 00 m 00 m 00 m 00 m Rated load voltage DC DC DC DC Current consumption from load voltage L+ m m 0 m m (without load) oltage inputs - - Min. input resistance (voltage range) 00 k - - 00 k Input voltage ranges 0... +0 - - 0... +0 Operational limit of voltage ranges +/-0.% - - +/-0.% Basic error limit voltage ranges +/-0.% - - +/-0.% Current inputs - - - Min. input resistance (current range) - 0 - - Input current ranges - 0 m... +0 m + m... +0 m - - Operational limit of current ranges - +/-0.%... +/-0.% - - Basic error limit current ranges - +/-0.%... +/-0.% - - Resistance inputs - - - - Resistance ranges - - - - Operational limit of resistor ranges - - - - Basic error limit - - - - Resistance thermometer inputs - - - - Resistance thermometer ranges - - - - Operational limit of resistance thermometer - - - - ranges Basic error limit thermoresistor ranges - - - - Thermocouple inputs - - - 0
nalog input modules Signal modules analog System SLIO Order number Thermocouple ranges - - type B type C type E type J type K type L type N type R type S type T - Operational limit of thermocouple ranges - - - - Basic error limit thermoelement ranges - - - - Programmable temperature compensation - - - - External temperature compensation - - - - Internal temperature compensation - - - - Resolution in bit Measurement principle successive approximation successive approximation Sigma-Delta Basic conversion time ms all channels ms all channels... ms (0 Hz)...0. ms (0 Hz) per channel successive approximation ms all channels Noise suppression for frequency 0 Hz 0 Hz 0/0 Hz 0 Hz Initial data size Byte Byte Byte Byte Status information, alarms, diagnostics Status display yes yes yes yes Interrupts no no yes no Process alarm no no yes, parameterizable no Diagnostic interrupt no no yes, parameterizable no Diagnostic functions yes yes yes yes Diagnostics information read-out possible possible possible possible Module state green LED green LED green LED green LED Module error display red LED red LED red LED red LED Channel error display red LED per channel red LED per channel red LED per channel red LED per channel Isolation Between channels - - - - Between channels of groups to - - - - Between channels and backplane bus Between channels and power supply Max. potential difference between circuits - - - - Max. potential difference between inputs DC DC - DC (Ucm) Max. potential difference between Mana - - - - and Mintern (Uiso) Max. potential difference between inputs - - - - and Mana (Ucm) Max. potential difference between inputs DC / C 0 DC / C 0 - DC / C 0 and Mintern (Uiso) Max. potential difference between Mintern and outputs - - - -
System SLIO Order number Insulation tested with DC 00 DC 00 DC 00 DC 00 Mechanical data Dimensions (WxHxD). mm. mm. mm. mm Weight 0 g 0 g 0 g 0 g Environmental conditions Operating temperature 0 C to 0 C 0 C to 0 C 0 C to 0 C 0 C to 0 C Storage temperature - C to 0 C - C to 0 C - C to 0 C - C to 0 C Certifications UL0 certification - - - -
nalog input modules Signal modules analog Connections, Interfaces System SLIO.... 0 0 0 0 DC DC DC DC
System SLIO nalog input modules Order number Figure Type SM 0, xbit I General information SM 0, xbit R, RTD Note - Coming soon Features inputs, Current 0...0 m inputs, Resistance 0...000, Resistance measurment with,, and wires Current consumption/power loss Current consumption from backplane bus 0 m m Power loss 0. W W Technical data analog inputs Number of inputs Cable length, shielded 00 m 00 m Rated load voltage DC DC Current consumption from load voltage L+ m 0 m (without load) oltage inputs - - Min. input resistance (voltage range) - - Input voltage ranges - - Operational limit of voltage ranges - - Basic error limit voltage ranges - - Current inputs - Min. input resistance (current range) 0 - Input current ranges 0 m... +0 m + m... +0 m Operational limit of current ranges +/-0.%... +/-0.% - Basic error limit current ranges +/-0.%... +/-0.% - Resistance inputs - Resistance ranges - 0... 0 Ohm 0... 00 Ohm 0... 000 Ohm Operational limit of resistor ranges - 0. % Basic error limit - 0. % Resistance thermometer inputs - Resistance thermometer ranges - Pt00 Pt000 Ni00 Ni000 -
nalog input modules Signal modules analog System SLIO Order number Operational limit of resistance thermometer - 0. % ranges Basic error limit thermoresistor ranges - 0. % Thermocouple inputs - - Thermocouple ranges - - Operational limit of thermocouple ranges - - Basic error limit thermoelement ranges - - Programmable temperature compensation - - External temperature compensation - - Internal temperature compensation - - Resolution in bit Measurement principle successive approximation Sigma-Delta Basic conversion time ms all channels... ms (0 Hz)...0. ms (0 Hz) per channel Noise suppression for frequency 0 Hz f=0/0 Hz Initial data size Byte Byte Status information, alarms, diagnostics Status display yes yes Interrupts no yes, parameterizable Process alarm no yes, parameterizable Diagnostic interrupt no yes, parameterizable Diagnostic functions yes yes Diagnostics information read-out possible possible Module state green LED green LED Module error display red LED red LED Channel error display red LED per channel red LED per channel Isolation Between channels - - Between channels of groups to - - Between channels and backplane bus Between channels and power supply Max. potential difference between circuits - - Max. potential difference between inputs DC - (Ucm) Max. potential difference between Mana - - and Mintern (Uiso) Max. potential difference between inputs - - and Mana (Ucm) Max. potential difference between inputs DC / C 0 - and Mintern (Uiso) Max. potential difference between Mintern - - and outputs Insulation tested with DC 00 DC 00
System SLIO Order number Mechanical data Dimensions (WxHxD). mm. mm Weight 0 g 0 g Environmental conditions Operating temperature 0 C to 0 C 0 C to 0 C Storage temperature - C to 0 C - C to 0 C Certifications UL0 certification - -
nalog input modules Signal modules analog Connections, Interfaces System SLIO.. 0 0 DC DC