INSTRUCTION MANUAL UTL260

Similar documents
INSTRUCTION MANUAL DL49

INSTRUCTION MANUAL Fax: (503)

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

INSTRUCTION MANUAL Fax: (503)

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

INSTRUCTION MANUAL INF Fax: (503)

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

312, 316, 318. Clamp Meter. Users Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

netzerotools.com 374/375/376 Users Manual Clamp Meter

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

USER'S MANUAL DMR-6700

OPERATOR S INSTRUCTION MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA220

DM-46 Instruction Manual

CONTENTS MS2033A. 1.Introduction Safety Information...01

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

374/375/376 Clamp Meter

INSTRUCTION MANUAL DL Fax: (503)

NOTE: Fully read and understand this manual before using this Digital Multimeter.

374/375/376 Clamp Meter

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Autoranging Multimeter Extech EX503

User Manual Digital Clamp Multimeter. model no.: MSR-C600

200Amp AC Clamp Meter + NCV Model MA250

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

INSTRUCTION MANUAL DL Fax: (503)

INSTRUCTION MANUAL ADM Fax: (503)

Digital Clamp Meter Model: &

DM-46 Instruction Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

INSTRUCTION MANUAL DMEG3/IRT Fax: (503)

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

User's Manual. Clamp-on Power Datalogger. Model

ET-3888 True RMS Clamp Meter. User Manual

374/375/376. Calibration Manual. Clamp Meter

AC/DC CLAMP METER USER S MANUAL

Model : OPERATING MANUAL Table of Contents (1)

600A Clamp Meters w/tightsight Display

Digital Multimeter, Pen Type

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User s Guide. Model MA A AC Mini Clamp-on Meter

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

R/C SMD Tweezers Multimeter Model RC200

AMM-1022 Digital Multimeter USER`S MANUAL

374 FC/375 FC/376 FC Clamp Meter

MS2030 CAT III 600 V A V AUTO RS232

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

ICM 136R Operating Instruction Electrical Clamp-Multimeter

Dawson DDM190. Digital Multimeter User s Manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

UT207A/208A/209A Operating Manual. Table of Contents

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

USER'S MANUAL DMR-2400

User Manual. All rights reserved. Specifications are subject to change without notice.

Mini Clamp Meter Model:

Model UT20B: OPERATING MANUAL Table of Contents (1)

Pen Multimeter. Model

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

374/375/376 Clamp Meter. Users Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

USER S MANUAL DMR-1500

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

User s Manual. Ground Resistance Clamp On Tester MODEL

12B/18 MultiMeter Instruction Sheet

USER'S MANUAL DMR-4350

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Table of Contents Title Page

OPERATING INSTRUCTIONS

ProfiScale MULTI Multimeter

OPERATING INSTRUCTIONS

374/375/376 Clamp Meter

902 FC. HVAC True-rms Clamp Meter

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DCM730. Digital Clamp Meter User s Manual

Pen Multimeter. Model

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Model UT201/202: OPERATING MANUAL. Table of Contents

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

3B SCIENTIFIC PHYSICS

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

323/324/325 Clamp Meter

KMD-S04 Multímetro de bolsillo

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User Manual Digital Multimeter

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model: &

Sales: Technical: Fax:

Transcription:

INSTRUCTION MANUAL UTL260 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com

Introduction The UTL260 has all the features and measurement functions that appliance technicians need. It s ruggedized and slim compact design makes for easy one handed use. Features include AC current 2A/20A/200A AC/DC voltage 600V Resistance 2kΩ Audible continuity LCD display with MAX reading 1999 Automatic indication of functions and symbols Sample rate: 2 times/sec for digital data Backlit display for use in low light application Read the safety precautions associated with the equipment being tested and seek assistance or advice when performing unfamiliar tasks. Keep your fingers away from the test lead metal probe contacts and bus-bars when making measurements. Always grip the instrument and test-leads behind the hand guards (molded into the probes). In the event of electrical shock, ALWAYS bring the victim to the emergency room for evaluation, regardless of the victim s apparent recovery. Electrical shock can cause an unstable heart rhythm that may need medical attention. International Symbols Safety Notes Before using this meter, read all safety information carefully. In this manual the word "WARNING" is used to indicate conditions or actions that may pose physical hazards to the user. The word "CAUTION" is used to indicate conditions or actions that may damage this instrument. Exceeding the specified limits of this meter is dangerous and can expose the user to serious or possibly fatal injury. DO NOT attempt to measure any voltage that exceeds 600 volts with this meter - UEi offers numerous alternatives for measuring high voltage and current Voltages above 60 volts DC or 30 volts AC may constitute a serious shock hazard DO NOT attempt to use this meter if either the meter or the test leads have been damaged. Send unit in for repair by a qualified repair facility Test leads must be fully inserted prior to taking measurements Always turn off power to a circuit (or assembly) under test before cutting, unsoldering or breaking the current path. Even small amounts of current can be dangerous Always disconnect the live test lead before disconnecting the common test lead from a circuit When measuring high voltage, disconnect the power source before making test lead connections. Connect the test leads to the meter first then to the circuit under test. Reapply power If any of the following indications occur during testing, turn off the power source to the circuit under test: Arcing Flame Smoke Extreme Heat Smell of Burning Materials Discoloration or Melting of Components C o n t rols and Indicators 1. Transformer jaws 2. Protection ring 3. Jaw opening trigger 4. Light key 5. LCD display 6. CO M t e r m i n a l 7. VΩ t e r m i n a l 8. Power key 9. R o t a ry switch 10. Hold key 1 2 3 4 5 10 9 8 6 7 UTL260-MAN P. 1

LCD Display Functional Description 1. Low battery indica t i o n 2. Hold data indica t i o n 3. C o n t i n u i ty function indica t i o n 4. Ohm measurement indica t i o n 5. Voltage measurement indica t i o n 6. Current measurement indica t i o n 7. DC input indica t i o n 8. AC input indica t i o n 9. Po l a r i ty indica t i o n 1 2 3 (Fig 1) 7 8 9 4 5 6 DC Voltage Measurement Maximum input voltage of DC V range is 600V DC. Do not attempt to take any voltage measurement that exceeds 600V DC to avoid electrical shock and/or damage to the instrument. 1. Set the rotary switch to the 600V range. Operating Instructions If the current under measurement is higher than the selected value for a long period, overheating may take place, compromising the safety and operation of inner circuits. 3. Connect the test leads to the circuit being measured and read the displayed value (Fig 2). DO NOT measure currents on high-voltage conductors (>600V) to avoid risk of discharge and/or incorrect readings. AC Current Measurement Make certain that all test leads are disconnected from the meter terminals. 1. Set the rotary switch to the desired A~range. 2. Clamp the current transducer (jaw) around one of the conductors under test. Make sure that the clamp jaw is closed (Fig 1). 3. Read the display value. 4. When only the figure 1 is displayed, it indicates over-range situation and the higher range has to be selected. (Fig 2) UTL260-MAN P. 2

AC Voltage Measurement Maximum input voltage of AC V range is 600Vrms. Do not attempt to take any voltage measurement that exceeds 600Vrms to avoid electrical shock hazard and/or damage to the instrument. 1. Set the rotary switch to the 600V~range. 3. Connect the test leads to the circuit being measured and read the displayed value (Fig 3). Continuity Measurement (Fig 4) Before taking any in-circuit resistance measurements, remove power from the circuit being tested and discharge all capacitors. 1. Set the rotary switch to Ω range. 3. Connect the test leads to the resistance in the circuit being measured (Fig 5). 4. When the test lead to the circuit is below 50Ω, it will be indicated by a continuous beeping. NOTE: Continuity test is available to check open/short of the circuit. (Fig 3) Resistance Measurement Before taking any in-circuit resistance measurements, remove power from the circuit being tested and discharge all capacitors. 1. Set the rotary switch to the 600V~range. 3. Connect the test leads to the circuit being measured and read the displayed value (Fig 4). Short Circuit Beeper Open Circuit (Fig 4) UTL260-MAN P. 3

M a i n t e n a n c e Periodic service Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or service could result in physical degradation of the meter. This could alter the protection from electrical shock and personal injury this meter provides to the operator. Perform only those maintenance tasks that you are qualified to do. These guidelines will help you attain long and reliable service from your meter: 1. Calibrate your meter annually to ensure it meets original performance specifications. 2. Keep your meter dry. If it gets wet, wipe it dry immediately. Liquids damage electronic circuits. 3. Whenever pra c t i cal, keep the meter away from dust and dirt, which can cause premature wear. 4. Although your meter is built to withstand the rigors of daily use, it can be damaged by severe impacts. Use reasonable caution when using and storing the meter. Cleaning and Decontamination Periodically clean your meter s case using a damp cloth. DO NOT use abrasives, cleaning solvents or strong detergents, as they may damage the finish or affect the reliability of the structural components. Battery Replacement Always use a fresh replacement battery of the specified size and type. Immediately remove the old or weak battery from the meter and dispose of it in accordance with your local disposal regulations. Old or defective batteries can leak chemicals that corrode electronic circuits. To avoid electric shock, be sure to turn off the meter s power and disconnect both test leads from any equipment before you remove or install batteries. Under NO circumstance should you expose batteries to extreme heat or fire as they may explode and cause injury. 3. Place a fresh 9V battery in the compartment. NOTE: If you do not plan to use the meter for a month or more, remove the battery and store it in an area that won t be damaged by a leaking battery. 4. Reattach the battery compartment cover to the meter and reinstall the screw. S p e c i f i c a t i o n s Environment conditions Installation categories II, 600V max. to earth Pollution degree 2 Altitude < 2000 m Operating temperature 0 ~40 C (<80% RH) Storage temperature -10 ~60 C (<70% RH, battery removed) Max. Voltage between 600 V rms terminals and earth ground Operating principal Dual slop integration Sample rate 2 times/sec for digital data Display 3-1/2 digits LCD display with max. Reading 1999 Automatic indication of functions and symbols Range selection Manual Over range indication LCD will display 1. If measure value is over 2000V the LCD will display 1 (AC V & DC V range) Low battery indication The is displayed when the battery is under the proper operation range Power source DC 3VX3, CR2032 Polarity indication - displayed automatically Jaw opening diameter cables 28mm Maximum conductor size 28mm Dimensions 194 (L) x 72 (W) x 35 (H) mm Weight 200g. Approx. (battery included) Accessories Manual Test leads Carrying case To install a new battery, follow these procedures: 1. Remove the screw from the battery compartment cover on the back of the meter and lift the cover. 2. Remove and discard the old battery. Always dispose of old batteries promptly in a manner consistent with local disposal regulations. UTL260-MAN P. 4

Measurement Specifications *Alignment marks MARK MARK CONDUCTOR MARK Audible Continuity Range Continuity beeper < approximately 50Ω Open circuit voltage: less than 700mV Overload protection: 250V DC or 250V AC rms Position the conductor within the jaws at the intersection of the indicated marks as much as possible in order to meet this meter s accuracy specifications. If the conductor is positioned elsewhere within the jaws, the max. additional error resulted is 1.5%. *Accuracy: ±(% of reading + number of digits) at 64 to 82 F (18 to 28 C) with relative humidity to 80%. AC Current 2A 0.001A 20A 0.01A ±(2%+5) 200A 0.1A Frequency response: 50/60Hz DC Voltage 600V 1V ±(1%+5) Input impedance: 10MΩ Maximum input voltage: 600V DC or 600V AC rms AC Voltage 600V 1V ±(1.5%+5) Input impedance: 10MΩ Frequency response: 40~400Hz Maximum input voltage: 600V DC or 600V AC rms Resistance 2kΩ 1Ω ±(1%+5) Open circuit voltage: less than 700mV Overload protection: 250V DC or 250V AC rms UTL260-MAN P. 5

UTL260 Digital Clamp-On Meter Limited Warranty The UTL260 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi s option. This warra n ty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warra n ty. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when r e p a i rable) for a service charge. Return the unit postage paid and insured to: 1-800-547-5740 FAX: (503) 643-6322 www.ueitest.com Email: info@ueitest.com UTL is distributed by UEi This warranty gives you specific legal rights. You may also have other rights which vary from state to state. PLEASE RECYCLE Copyright 2007 UEi UTL260-MAN 4/07