Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Similar documents
Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Three-phase monitoring relay CM-PFS

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Three-phase monitoring relay CM-PVE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-SDS.22

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relay CM-PBE

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Power supply CP-T 48/20.0 Primary switch mode power supply

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Three-phase monitoring relays

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relay

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-MFS.21

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-D 12/2.1

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

CP-T range Product group picture

Electronic timer CT-SDD.22

Electronic timer CT-TGD.22

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

CP-E range Benefits and advantages

CP-T range Benefits and advantages

Primary switch mode power supplies Product group picture

Power supply CP-D 24/4.2 Primary switch mode power supply

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-E 24/0.75

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Three-phase monitoring relays Product group picture

Power supply CP-E 24/2.5

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

Power supply CP-D 24/1.3

Three-phase monitoring relay

Analog signal converters CC-E I/I

Control module CP-A CM

Thermistor motor protection relays

Control module CP-A CM

CM-IWM.11 Insulation monitoring relay

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Pluggable interface relays CR-U Universal relays

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Analog signal converters CC range

Subject to changes 11/2003 Page 1/7

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Thermistor motor protection relays

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

Insulation Monitoring Relays CM range

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Switching power supplies CP range, Linear power supplies CP-L range. Content

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Transcription:

Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation monitoring relay CM-IWN.x for monitoring the insulation resistance up to 690 V AC and 1000 V DC in accordance with IEC 61557-8. The CM-IVN is available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals). 2CDC 251 027 V0012 Characteristics Expansion of the nominal voltage range of the insulation monitoring relay CM-IWN.x for monitoring the insulation resistance of unearthed IT systems up to 690 V AC and 1000 V DC According to IEC/EN 61557-8 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Part 8: Insulation monitoring devices for IT systems" Passive device, no supply voltage needed Screw connection technology or Easy Connect Technology available Housing material for highest fire protection classification UL 94 V-0 Tool-free mounting on DIN rail as well as demounting 45 mm (1.77 in) width Approvals / Marks A C R E L / a b Classifcations: EN 50155, IEC 60571, NF F 16-101/102, EN 45545-2 EN 50155, IEC 60571 Temp. Voltage supply Vibration and shock Coated pcb. class S1 S2 C1 C2 acc to IEC/EN 61373 T3 n/v n/v n/v n/v Cat 1, Class B no NF F 16-101/102 EN 45545-2 Flammability index Opticity and toxicity of smoke index Risk level achieved I2 F2 HL3 Order data Coupling unit Type Nominal voltage U n of the distribution Rated control supply voltage Connection technology Order code system to be monitored CM-IVN.P 0-690 V AC / 0-1000 V DC Passive device, no control Push-in terminals 1SVR 760 669 R9400 CM-IVN.S supply voltage needed Screw type terminals 1SVR 750 669 R9400 Accessories Type Description Order code ADP.02 Adapter for screw mounting 1SVR 440 029 R0100 MAR.01 Marker label 1SVR 366 017 R0100 COV.12 Sealable transparent cover 1SVR 750 005 R0100

Functions Application / monitoring function The coupling unit CM-IVN is designed to extend the nominal voltage range of the insulation monitoring relay CM-IWN.x up to 690 V AC and 1000 V DC. The coupling unit can be connected to the system to be monitored by means of the terminals V and. The terminal Vw has to be connected to the earth potential. The terminals, V1+,, V1-, VS and VE have to be connected to the CM-IWN.x as shown in the connection diagrams below. Supply systems with voltages U n = 0-690 V AC (15-400 Hz) or 0-1000 V DC can be connected. Measuring principle With CM-IWN.x a pulsating measuring signal is fed into the system to be monitored and the insulation resistance calculated. This pulsating measuring signal alters its form depending on the insulation resistance and system leakage capacitance. From this altered form the change in the insulation resistance is forecast. When the forecast insulation resistance corresponds to the insulation resistance calculated in the next measurement cycle and is smaller than the set threshold value, the output relays are activated or deactivated, depending on the device configuration. This measuring principle is also suitable for the detection of symmetrical insulation faults. Connection and wiring Connection diagram L1 L2 L3 N V A1 11 21 S1 S2 S3 2CDC 252 107 F0b09 CM-IVN CM-IWN.x V1+ VS VE V1- Vw 12 14 VS V1+ V1-22 24 KE A2 w 2CDC 252 107 F0009 VE Connection to CM-IWN.x - w VS Connection to CM-IWN.x - VS Connection to CM-IWN.x - V1+ Connection to CM-IWN.x - V1+ Connection to CM-IWN.x - V1- Connection to CM-IWN.x - V1- V, Measuring circuit / Measuring input Connection to the system Vw Measuring circuit / Measuring input Connection to earth 2 - Coupling unit CM-IVN Data sheet

Wiring diagrams Always connect and to different conductors. and can be connected to any of the conductors. U n 690 V AC; 1000 V DC V V 2CDC 252 082 F0009 L N 12 14 VS V1+ V1-2CDC 252 087 F0009 2CDC 252 088 F0009 PWM DC 12 14 VS V1+ V1-2CDC 252 087 F0009 2-wire AC system 2-wire DC system V V 2CDC 252 089 F0009 L1 L2 L3 12 14 VS V1+ V1-2CDC 252 094 F0009 2CDC 252 095 F0009 PWM DC PWM DC M 12 14 VS V1+ V1-2CDC 252 094 F0009 3-wire AC system 3-wire DC system V 2CDC 252 096 F0009 L1 L2 L3 N 12 14 VS V1+ V1-2CDC 252 101 F0009 4-wire AC system Data sheet Coupling unit CM-IVN - 3

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Input circuit - Measuring circuit V,, Vw Function expansion of the nominal voltage range of the insulation monitoring relay CM-IWN.x to 690 V AC or 1000 V DC, max. length of connection cable 40 cm Measuring principle see CM-IWN.x Nominal voltage U n of the distribution system to be monitored 0-690 V AC / 0-1000 V DC Voltage range of the distribution system to be monitored 0-793.5 V AC / 0-1150 V DC (tolerance +15 %) Rated frequency f N of the distribution system to be monitored DC or 15-400 Hz Tolerance of the rated frequency f N 13.5-440 Hz System leakage capacitance C e max. identical to that of the insulation monitoring relay used Extraneous DC voltage U fg (when connected to an max. 793.5 V DC AC system) Tolerance of the adjusted threshold value / Relative percentage at 1-10 kω R F M 15 %; max. ±1.5 kω uncertainty A at 10-15 kω R F ±1.5 kω at -5...+45 C, U n = 0-115 %, U s = 85-110 %, f N, f s, C e = 1µF at 15-200 kω R F ±8 % Internal impedance Z i at 50 Hz 195 kω Internal DC resistance R i 200 kω Measuring voltage U m 24 V Tolerance of measuring voltage U m +10 % Measuring current I m 0.15 ma General data MTBF on request Duty time 100 % Dimensions (W x H x D) 45 x 78 x 100 mm (1.78 x 3.07 x 3.94 in) Screw connection technology Easy Connect Technology (push-in) Weight net weight 0.179 kg (0.395 lb) 0.165 kg (0.364 lb) gross weight 0.203 kg (0.448 lb) 0.189 kg (0.417 lb) Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units not necessary 10 mm (0.39 in) at U n > 400 V Degree of protection housing / terminal IP50 / IP20 Electrical connection Connecting capacity Stripping length Tightening torque Max. length of connection cable to CM-IWN.x fine strand with(out) wire end ferrule rigid Screw connection technology 1 x 0.5-2.5 mm² (1 x 18-14 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 8 mm (0.32 in) 0.6-0.8 Nm (7.08 lb.in) 40 cm Easy Connect Technology (push-in) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) - 4 - Coupling unit CM-IVN Data sheet

Environmental data Ambient temperature ranges operation -25...+60 C (-13...+140 F) storage -40...+85 C (-40...+185 F) transport -40...+85 C (-40...+185 F) Climatic class IEC/EN 60721-3-3 3K5 (no condensation, no ice formation) Damp heat, cyclic IEC/EN 60068 2 30 6 x 24 h cycle, 55 C, 95 % RH Vibration, sinusoidal 25 Hz: 2.5 g Isolation data Rated impulse withstand voltage U imp input circuit / 8 kv Rated insulation voltage U i input circuit / 1000 V Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 60947-5-1, IEC/EN 61557-1, IEC/EN 61557-8 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Railway application standards EN 50155, IEC 60571 temperature class T3 Railway applications Electronic equipment used on rolling stock supply voltage category n/a IEC/EN 61373 Category 1, Class B Railway applications Rolling stock equipment Shock and vibration tests EN 45545-2 Railway applications Fire protection on railway vehicles part 2: HL3 Requirements for fire behavior of materials and components ISO 4589-2 LOI 32.3 % NF X-70-100-1 C.I.T. (T12) 0.45 EN ISO 5659-2 Ds max (T10.03) 104 NF F 16-101: Rolling stock. Fire behaviour. Materials choosing I2 / F2 NF F 16-102: Railway rolling stock. Fire behaviour. Materials choosing, application for electric equipment DIN 5510-2 Preventive fire protection in railway vehicles. Part 2: Fire behaviour and fire fullfilled side effects of materials and parts Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4 electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kv / 8 kv radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz) electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 kv / 5 khz surge IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit 1 kv L, 2 kv earth conducted disturbances, induced by radio-frequency IEC/EN 61000-4-6 Level 3, 10 V fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 Class 3 harmonics and interharmonics IEC/EN 61000-4-13 Class 3 Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B Data sheet Coupling unit CM-IVN - 5

Dimensions in mm and inches 114.5 4.51 107.0 4.21 45.0 1.77 85.6 3.37 104.8 4.13 2CDC 252 022 F0011 Accessories in mm and inches 11.5 0.453 45.0 0.89 9.3 0.37 5.75 0.23 45 1.772 35 1.378 6.5 0.256 60 2.362 62.5 2.461 70 2.756 10 0.394 20 0.787 2CDC 252 009 F0010 22.2 0.874 4T22 19.9 0.783 7.85 0.309 2CDC 252 020 F0011 68 2.68 front to back 111.8 4.40 2CDC 252 023 F0011 ADP.02 Adapter for screw mounting MAR.12 Marker label for devices with DIP switches COV.12 Sealable transparent cover Further documentation Document title Document type Document number Electronic products and relays Catalog 2CDC 110 004 C02xx CM-IWN.1 Instruction sheet 1SVC 750 020 M0000 CM-IWN.4, CM-IWN.5, CM-IWN.6 Instruction sheet 1SVC 750 030 M0000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls -> Measuring and monitoring relays CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls 6 - Coupling unit CM-IVN Data sheet

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 112 200 D0201 (06.2016) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2016 ABB All rights reserved