Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration

Similar documents
Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Overview.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Configuration.

Continuous level measurement Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

SITRANS L Level instruments

Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION. Configuration. Installation

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/210 Siemens FI Overview.

SITRANS LR 300: High Performance Radar for Level Measurement

OEM radar transmitter, for aggressive media level measurement

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

Level Measurement. 4/2 Product overview

Level Measurement. 4/2 Overview

Flow Measurement SITRANS F M

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Level Measurement. 4/2 Overview

LEVEL WITH US. to Effectively Minimize Process Upsets. 25 GHz pulse radar for liquids and slurries in general service and process applications

SITRANS L Level instruments

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS L Level instruments

Rosemount 3101, 3102, and 3105

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Siemens AG Level Measurement

Level measurement Radar

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

OPTIFLUX 5000 Technical Datasheet

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

Instruction Manual September sitrans LR 300

Instruction Manual September sitrans LR 300 (HART)

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

OPTIWAVE 1010 Technical Datasheet

Flow Measurement SITRANS F M

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Instruction Manual May sitrans LR300

SITRANS T measuring instruments for temperature

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

OPTIFLUX 5000 Technical Datasheet

Instruction Manual August sitrans LR 200

Instruction Manual May iq radar

Main features. Operation. LEVEL Transmitters

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

IQ RADAR 300. Instruction Manual March 2001

PiloTREK SZINTTÁVADÓK. Pulse burst radar level transmitters 5 YEARS WARRANTY

Rosemount 5400 Series Radar Level Transmitter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

2-Wire. Level Gauge BM 702

VITO LT. Global Experience. Locally Applied. A dependable choice.

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Coriolis Massflowmeter

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

Magnetostrictive Level Transmitter

Process display RIA 261

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Indumax CLS50/CLS50D. Technical Information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

Condumax CLS21 and CLS21D

Digital flow transmitter for continuous flow measurement

K-BAND RADAR FOR LIQUIDS

Rosemount 5408 and 5408:SIS Level Transmitters

OPTIWAVE 6300 C Technical Datasheet

RADIATED MICROWAVES. Application. Working frequency. 6 GHz Band C 6 GHz Band C. Working temperature C C.

IQ RADAR 160. Instruction Manual PL-550 January Rev. 3.2

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Technical Description. High Performance Radar Microwave Level Gauge

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Technical Information Condumax CLS21D/CLS21

Condumax W CLS15 and CLS15D

Ultrasonic level transmitter, non-contact

Coriolis Mass Flow Meter Model TM

OPTIWAVE 7400 C Technical Datasheet

OPTIWAVE 5200 C/F Technical Datasheet

Temperature Measurement Transmitter for field mounting/field indicator

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Resistance thermometer Model TR30, compact design

FLOWMETER. Siemens MAG 5000/6000. Overview

Temperature Measurement

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

Transcription:

Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature, pressure, agitation, and turbulence to a range of 20 m (65 ft). Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. Beam angle for horn antenna dependent on horn size The peak energy density is directly in front of and in line with the rod antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected. Mounting unit on vessel Beam angle Rod: 28 " horn: 29 6" horn: 20 8" horn: 17 Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support Communication using HART or PROFIBUS PA Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or SIMATIC PDM Application s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. It also features a built-in alphanumeric display in four languages. The has a standard Uni-Construction polypropylene rod antenna that offers excellent chemical resistance and is hermetically sealed. The Uni-Construction antenna features an internal, integrated shield that eliminates vessel nozzle interference. Startup is easy with as few as two parameters for basic operation. Installation is simplified as the electronics are mounted on a rotating head that swivels, allowing the instrument to line up with conduit or wiring connections or simply to adjust the position for easy viewing. features Process Intelligence signal-processing technology for superior reliability. Key Applications: liquid process vessels with agitators, vaporous liquids, high temperatures, asphalt Conical Mounting unit on stilling well Flat Orient front or back of device toward stillpipe slots. installation, dimensions in mm (inch) Parabolic Mounting on a nozzle Min. 10 (0.) /196 Siemens FI 01 2018

Level Measurement Integration with flange adapter for connection to optional antennas. Horn with waveguide extension. Used for high temperature isolation, long standpipes, and clearing tank obstructions. Flat faced flange connection with PTFE rod antenna. Shielded rod antenna with a stainless steel shield eliminates standpipe interference. Various lengths available. Antenna configurations for Antenna types Flat Faced Flange with Rod Shielded Rod Horn (", 6", 8" sizes available) Connection type Flat faced flange nominal pipe sizes 50, 80, 100, 150 mm (2, 3,, 6 inch) Threaded 2" NPT, R 2" (BSPT), G 2" (BSPP) or flat faced flangenominal pipe sizes 80, 100 mm (3, inch) Flat faced flangenominal pipe sizes 50, 80, 100, 150 mm (2, 3,, 6 inch) Wetted parts PTFE PTFE, 316L stainless steel, FKM O-ring 316L stainless steel PTFE, FKM O-ring Extensions 50 or 100 mm (2 or inch) PTFE or UHMW-PE 1) Maximum pressure 0.5 bar g at 60 C (7.25 psi g at 10 F) 2) Not including extensions, includes and smallest process connection 100, 150, 200 or 250 mm (, 6, 8 or 10 inch) standard shield length Use waveguide for extensions to 6 m (20 ft) long Dielectric constant > 3 > 3 > 3 Insertion length (max.) 1 cm (16.3 inch) Variable Variable with extension Purging option (liquid or gas) No No Yes Sliding waveguide option for digesters Yes No Yes 1) Weight 2) 6.5 kg (1.3 lb) 5.0 kg (11 lb) 7.5 kg (16.5 lb) Siemens FI 01 2018 /197

Technical specifications Mode of operation Measuring principle Radar level measurement Frequency C-band, approx. 6 GHz Measuring range 0.3... 20 m (1.0... 65 ft) Output Analog output... 20 ma Accuracy ± 0.02 ma Span Proportional or inversely proportional Communications HART Optional: PROFIBUS PA (Profile 3.0, Class B) Fail-safe Programmable as high, low or hold (Loss of Echo) Performance (according to reference conditions IEC60770-1) From end of antenna to 600 mm 0 mm (1.57 inch) Remainder of range 10 mm (0. inch) or 0.1 % of span (whichever is greater) Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature -0... +80 C (-0... +176 F) Installation category I Pollution degree Medium conditions Dielectric constant r r >1.6 (for r < 3, use stillpipe) Vessel temperature and pressure Varies with connection type; see Pressure/Temperature curves for more information Design Enclosure Material Aluminum, polyester powder coated Cable inlet 2 x M20 x 1.5 or 2 x ½" NPT Degree of protection Type X/NEMA X, Type 6/ NEMA 6, IP67, IP68 Weight < 2.82 kg (6.21 lb) (polypropylene rod antenna) Display (local) Multi-segment alphanumeric liquid crystal with bar graph (representing level) available in four languages Antenna Material Polypropylene rod, hermetically sealed construction, optional PTFE Dimensions Standard 100 mm ( inch) shield for maximum 100 mm ( inch) nozzle, or optional 250 mm (10 inch) long shield Optional rods and horn Refer to Antennas for optional rods and horns Process connections Process connection Flange connection 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226], or G 1½" [(BSPP), EN ISO 228-1] (polypropylene rod antenna) Refer to Antennas for more connections Power supply... 20 ma/hart General Purpose, Non-incendive, Nominal 2 V DC (max. 30 V DC) with Intrinsically Safe max. 550 Flame proof, Increased safety, Nominal 2 V DC (max. 30 V DC) with Explosion proof max. 250 PROFIBUS PA 10.5 ma Per IEC 61158-2 Certificates and approvals General CSA US/C, CE, FM, RCM Marine Lloyd s Register of Shipping ABS Type Approval Radio FCC, Industry Canada, and European (RED), RCM Hazardous Intrinsically Safe (Brazil) INMETRO Ex ia IIC T Ga Explosion Proof (Canada/USA) CSA/FM, Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, T Intrinsically Safe (Canada/USA) CSA/FM, Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, T Non-incendive (USA) FM, Class I, Div. 2, Groups A, B, C, D, T5 Flame Proof/Increased Safety NEPSI Ex d mb ia IIC T/ Ex e mb ia (China) IIC T Flame Proof (Europe) ATEX II 1/2 G Ex d mb ia IIC T Ga/ Gb Increased Safety (Europe) ATEX II 1/2 G Ex e mb ia IIC T Ga/ Gb Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T Intrinsically Safe (International) IECEx Ex ia IIC T Intrinsically Safe EAC Ex ia (Russia/Kazakhstan) Programming Intrinsically Safe Siemens handheld Infrared receiver programmer Approvals for handheld programmer IS model: ATEX II 1GD Ex ia IIC T Ga Ex iad 20 T135 C T a = -20... +50 C CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, D, E, F, G, T6 T a = +50 C Handheld communicator HART communicator 375 PC SIMATIC PDM AMS SITRANS DTM (for connecting to FDT such as PACTware or Fieldcare) Display (local) Multi-segment alphanumeric liquid crystal with bar graph (representing level) available in four languages /198 Siemens FI 01 2018

Level Measurement, Uni-Construction 7ML522- polypropylene rod antenna version 7 7 770 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Max. 3 bar g (3.5 psi g) pressure and 80 C (176 F) Click on the for the online configuration in the PIA Life Cycle Portal. Enclosure/Cable inlet Aluminum, epoxy painted 2 x ½" NPT 2 2 x M20 x 1.5 3 Polypropylene antenna type - (Max. 3 Bar pressure and 80 C) 1½" NPT [(Taper), ANSI/ASME B1.20.1], A c/w integral 100 mm shield R 1½" [(BSPT), EN 10226], B c/w integral 100 mm shield G 1½" [(BSPP), EN ISO 228-1], C c/w integral 100 mm shield 1½" NPT [(Taper), ANSI/ASME B1.20.1], D c/w integral 250 mm shield R 1½" [(BSPT), EN 10226], E c/w integral 250 mm shield G 1½" [(BSPP), EN ISO 228-1], F c/w integral 250 mm shield Approvals General Purpose, CE, RED, RCM A General Purpose, CSA, FM, Industry Canada, FCC B Intrinsically Safe, CSA Class I, II, Div. 1, C Groups A, B, C, D, E, F, G, Industry Canada Intrinsically Safe, FM Class I, II, Div. 1, D Groups A, B, C, D, E, F, G, FCC Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T, E INMETRO Ex ia IIC T, CE, RED, RCM; EAC Non incendive, FM Class I, Div. 2, F Groups A, B, C, D, FCC 1) Increased Safety, ATEX II 1/2G Ex e mb ia IIC T G Ga/Gb, CE, RED, RCM; EAC 2)3) Flame Proof, ATEX II 1/2G Ex d mb ia IIC T Ga/ H Gb, CE, RED, RCM; EAC 3) Explosion Proof, CSA/FM Class I, II, III, Groups A, J B, C, D, E, F, G, Industry Canada, FCC 1)3) Communication/Output PROFIBUS PA 2... 20 ma, HART, start-up at < 3.6 ma 3 1) Available with enclosure option 2 only 2) Available with enclosure option 3 only 3) Available with communication option 3 only Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: C11 M to DIN 55350, Part 18 and to ISO 9000 Namur NE3 compliant, device preset to failsafe N07 <3.6mA 1) Operating Instructions All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Accessories Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK HART modem/usb 7MF997-1DB (for use with a PC and SIMATIC PDM) One metallic cable gland M20 x 1.5, 7ML1930-1AP rated -0... +80 C (-0... +176 F), HART 2) One metallic cable gland M20 x 1.5, 7ML1930-1AQ rated -0... +80 C (-0... +176 F), PROFIBUS PA 2) One general purpose polymeric cable gland 7ML1930-1AM M20 x 1.5, rated -20... + 80 C (-0... +176 F) SITRANS RD100, loop powered display - 7ML571-... see Chapter 7 SITRANS RD200, universal input display with 7ML570-... Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML57-... and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML5750-... solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available with communication option 3 only 2) Product shipped with plastic cable gland, rated to -20 C. If -0 C rating required, then metallic cable gland is recommended. Siemens FI 01 2018 /199

, Flange Adapter/PTFE Rod 7ML523- Antenna Version 77777-7777 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Click on the for the online configuration in the PIA Life Cycle Portal. Antenna material (uses antenna adapter) PTFE, uses antenna adapter and 1 additional process connection below Process connection (refer to Pressure/ Temperature curves, page /20) Flanges (316L stainless steel) DN 50 PN 16, Type A, flat faced AA DN 80 PN 16, Type A, flat faced BA DN 100 PN 16, Type A, flat faced CA DN 150 PN 16, Type A, flat faced DA 2" ASME 150 lb, flat faced FB 3" ASME 150 lb, flat faced GB " ASME 150 lb, flat faced HB 6" ASME 150 lb, flat faced JB DN 50 PN 0, flat faced AC DN 80 PN 0, flat faced BC DN 100 PN 0, flat faced CC DN 150 PN 0, flat faced DC 2" ASME 300 lb, flat faced, available with FD Pressure rating option 1 only due to flange hole spacing 3" ASME 300 lb, flat faced GD " ASME 300 lb, flat faced HD 6" ASME 300 lb, flat faced JD JIS DN 50 10K AE JIS DN 80 10K BE JIS DN 100 10K CE JIS DN 150 10K DE (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1, or JIS B 2220 standard.) Threaded connection (316L stainless steel) 1½" NPT [(Taper), ANSI/ASME B1.20.1] LA 2" NPT [(Taper), ANSI/ASME B1.20.1] MA R 1½" [(BSPT), EN 10226] LC R 2" [(BSPT), EN 10226] MC G 1½" [(BSPP), EN ISO 228-1] LE G 2" [(BSPP), EN ISO 228-1] ME Antenna extensions or Inactive shield length No antenna extension 0 50 mm (2 inch) extension, PTFE 1 100 mm ( inch) extension, PTFE 2 100 mm ( inch) extension, 3 316L stainless steel shield 1) 150 mm (6 inch) extension, 316L stainless steel shield 1) 200 mm (8 inch) extension, 5 316L stainless steel shield 1) 250 mm (10 inch) extension, 6 316L stainless steel shield 1) Process seal/gasket Integral Gasket, 0 for flat faced flange process connections only, not for Antenna extension options 3... 6 FKM O-ring, 1 not available for combination of flat faced flanges with Antenna extension options 0, 1 or 2, Flange Adapter/PTFE Rod 7ML523- Antenna Version 77777-7777 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 2 2 x M20 x 1.5 3 Communication/Output PROFIBUS PA B... 20 ma, HART, start-up at < 3.6 ma C Approvals General Purpose, CE, RED, RCM A General Purpose, CSA, FM, Industry Canada, FCC B Intrinsically Safe, CSA Class I, II, Div. 1, C Groups A, B, C, D, E, F, G, Industry Canada Intrinsically Safe, FM Class I, II, Div. 1, D Groups A, B, C, D, E, F, G, FCC Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T, E INMETRO Ex ia IIC T, CE, RED, RCM; EAC Non incendive, FM Class I, Div. 2, F Groups A, B, C, D, FCC 2) Increased Safety, ATEX II 1/2G Ex e mb ia IIC T G Ga/Gb, CE, RED, RCM; EAC 3)) Flame Proof, ATEX II 1/2G Ex d mb ia IIC T Ga/ H Gb, CE, RED, RCM; EAC ) Explosion Proof, CSA/FM Class I, II, III, Groups A, J B, C, D, E, F, G, Industry Canada, FCC 2)) Pressure rating Rating per Pressure/Temperature curves in manual 0 0.5 bar g (7.25 psi g) maximum 1 1) Available with process connection options BA, CA, DA, GB, HB, JB, BC, CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only 2) Available with enclosure option 2 only 3) Available with enclosure option 3 only ) Available with communication option C only /200 Siemens FI 01 2018

Level Measurement Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 Material inspection Certificate Type 3.1 per EN 1020 Namur NE3 compliant, device preset to failsafe <3.6mA 3) Operating Instructions All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Accessories Handheld programmer, Intrinsically safe, EEx ia Antenna, rod, PTFE Antenna extension, 50 mm (2 inch), PTFE Antenna extension, 100 mm ( inch), PTFE HART modem / USB (for use with PC and SIMATIC PDM) Metallic cable gland M20 x 1.5, rated -0 C (-0 F)... 80 C (176 F), HART (two are required) Metallic cable gland M20 x 1.5, rated -0 C (-0 F)... 80 C (176 F), PROFIBUS PA (two required) One General Purpose polymeric cable gland M20 x 1.5, rating for -20 C (- F)... + 80 C (176 F) SITRANS RD100, loop powered display - see Chapter 7 SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section Order code Y15 C11 C12 N07 7ML1930-1BK 7ML1830-1HC 7ML1830-1CH 7ML1830-1CG 7MF997-1DB 7ML1930-1AP 7ML1930-1AQ 7ML1930-1AM 7ML571-... 7ML570-... 7ML57-... 7ML5750-... Siemens FI 01 2018 /201

, Flange adapter/horn Antenna version 7ML525-77777 - 7777 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Click on the for the online configuration in the PIA Life Cycle Portal. Antenna material (uses antenna adapter) 316L stainless steel with PTFE cone emitter 0 316L stainless steel with PTFE cone emitter and purge connection with 1/8" NPT inlet 1) 1 Process connection (refer to Pressure/ Temperature curves, page /20) Flanges (316L stainless steel) DN 50 PN 16 EN 1092-1 Type A flat faced 1) AA DN 80 PN 16 EN 1092-1 Type A flat faced BA DN 100 PN 16 EN 1092-1 Type A flat faced CA DN 150 PN 16 EN 1092-1 Type A flat faced DA DN 200 PN 16 EN 1092-1 Type A flat faced EA DN 80 PN 10/16 DIN EN 1092-1 Type B1 raised face 2) BF DN 100 PN 10/16 DIN EN 1092-1 Type B1 raised face 3) CF DN 150 PN 10/16 DIN EN 1092-1 Type B1 raised face 3) DF DN 200 PN 16 DIN EN 1092-1 Type B1 raised face 3) EF 2" ASME 150 lb, flat faced 1) FB 3" ASME 150 lb, flat faced GB " ASME 150 lb, flat faced HB 6" ASME 150 lb, flat faced JB 8" ASME 150 lb, flat faced KB DN 50 PN 0, flat faced 3) AC DN 80 PN 0, flat faced 3) BC DN 100 PN 0, flat faced 3) CC DN 80 PN 25/0 DIN EN 1092-1 Type B1 raised face 3) CG DN 100 PN 25/0 DIN EN 1092-1 Type B1 raised DG face 3) DN 150 PN 25/0 DIN EN 1092-1 Type B1 raised EG face 3) 2" ASME 300 lb, flat faced 1)3) FD 3" ASME 300 lb, flat faced 3) GD " ASME 300 lb, flat faced 3) HD JIS DN 50 10K 1) AE JIS DN 80 10K BE JIS DN 100 10K CE JIS DN 150 10K DE JIS DN 200 10K EE (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1, or JIS B 2220 standard.) Communication/Output PROFIBUS PA 1... 20 ma, HART, start-up at < 3.6 ma 2, 7ML525- Flange adapter/horn Antenna version 77777-7777 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Process seal/gasket FKM (-0... +200 C) 0 Nitrile (-0... +60 C) 1 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 2 2 x M20 x 1.5 3 Horn size/waveguide options 80 mm (3 inch) horn 3) B 100 mm ( inch) horn ) C 150 mm (6 inch) horn D 200 mm (8 inch) horn E 100 mm ( inch) horn with 100 mm ( inch) F ) 100 mm ( inch) horn with 150 mm (6 inch) G ) 100 mm ( inch) horn with 200 mm (8 inch) H wave-guide extension ) 100 mm ( inch) horn with 250 mm (10 inch) J ) 150 mm (6 inch) horn with 100 mm ( inch) K 150 mm (6 inch) horn with 150 mm (6 inch) L 150 mm (6 inch) horn with 200 mm (8 inch) M 150 mm (6 inch) horn with 250 mm (10 inch) N 200 mm (8 inch) horn with 100 mm ( inch) P 200 mm (8 inch) horn with 150 mm (6 inch) Q 200 mm (8 inch) horn with 200 mm (8 inch) R 200 mm (8 inch) horn with 250 mm (10 inch) S /202 Siemens FI 01 2018

Level Measurement, 7ML525- Flange adapter/horn Antenna version 77777-7777 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process vessels including high temperature and pressure, to a range of 20 m (66 ft). Approvals General Purpose, CE, RED, RCM A General Purpose, CSA, FM, Industry Canada, FCC B Intrinsically Safe, CSA Class I, II, Div. 1, C Groups A, B, C, D, E, F, G, Industry Canada Intrinsically Safe, FM Class I, II, Div. 1, D Groups A, B, C, D, E, F, G, FCC Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T, E INMETRO Ex ia IIC T, CE, RED, RCM; EAC Non incendive, FM Class I, Div. 2, F Groups A, B, C, D, FCC ) Increased Safety, ATEX II 1/2G Ex e mb ia IIC T G Ga/Gb, CE, RED, RCM; EAC 5)6) Flame Proof, ATEX II 1/2G Ex d mb ia IIC T Ga/Gb, H CE, RED, RCM; EAC 6) Explosion Proof, CSA/FM Class I, II, III, Groups A, J B, C, D, E, F, G, Industry Canada, FCC 5)6) Pressure rating Rating per Pressure/Temperature curves in manual 0 0.5 bar g (7.25 psi g) maximum 1 1) Available with pressure rating option 1 only 2) Available with Antenna Material options 0 and 1 only 3) For stillpipe applications only ) Available with enclosure option 2 only 5) Available with enclosure option 3 only 6) Available with communication option 2 only Order code Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters); specify in plain text Manufacturer's test certificate: C11 M to DIN 55350, Part 18 and to ISO 9000 Material inspection Certificate Type 3.1 per C12 EN 1020 Namur NE3 compliant, device preset to failsafe N07 <3.6mA 1) Operating Instructions All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Accessories Handheld programmer, Intrinsically safe, EEx ia 7ML1930-1BK HART modem/usb 7MF997-1DB (for use with a PC and SIMATIC PDM) One metallic cable gland M20 x 1.5, 7ML1930-1AP rated -0... +80 C (-0... +176 F), HART 2) One metallic cable gland M20 x 1.5, 7ML1930-1AQ rated -0... +80 C (-0... +176 F), PROFIBUS PA 3) One general purpose polymeric cable gland 7ML1930-1AM M20 x 1.5, rated -0... +80 C (-0... +176 F) SITRANS RD100, loop powered display - 7ML571-... see Chapter 7 SITRANS RD200, universal input display with 7ML570-... Modbus conversion - see Chapter 7 SITRANS RD300, dual line display with totalizer 7ML57-... and linearization curve and Modbus conversion - see Chapter 7 SITRANS RD500 web, universal remote monitoring 7ML5750-... solution for instrumentation - see Chapter 7 For applicable back up point level switch - see point level measurement section 1) Available with communication option 2 only 2) Product shipped with plastic cable gland, rated to -20 C. If -0 C rating required, then metallic cable gland is recommended. 3) Available with enclosure option 2 only Siemens FI 01 2018 /203

Characteristic curves Maximum flange and process temperatures versus allowable ambient temperature Ambient temperature ( C) 90 130 C 80 70 67 C 60 50 Polypropylene rod PTFE rod/ 0 horn antenna 30 20 10 0 0 20 0 60 80 100 120 10 160 180 200 220 Process flange surface temperature ( C) ambient/process flange surface temperature curve /20 Siemens FI 01 2018

Level Measurement 16.0 PTFE rod antenna with integral gasket 150# and PN 16 sizes flange series 2252, 316 stainless steel, flat face Pressure (bar, gauge) 1.0 12.0 10.0 8.0 6.0.0 (A) (B) (C) (A) 2252 50 mm/2 inch nom. 2.0 (B) 2252 80 mm/3 inch nom. 0.0-0 -20 0 20 0 60 80 100 120 10 160 180 200 Temperature ( C) (C) 2252 100 mm/ inch nom. Pressure (bar, gauge) 16.0 1.0 12.0 10.0 8.0 6.0.0 Horn antenna and/or wave guide with PTFE emitter 150# and PN 16 sizes flange series 2252, 316 stainless steel, flat face (E) (F) (G) (D) (D) 2252 80 mm/3 inch nom. (E) 2252 100 mm/ inch nom. 2.0 (F) 2252 150 mm/6 inch nom. 0.0-50 0 50 100 150 200 Temperature ( C) (G) 2252 200 mm/8 inch nom. 0.0 Threaded process 1.5" & 2" NPT, BSP, & G 35.0 Pressure (bar, gauge) 30.0 25.0 20.0 15.0 10.0 5.0 (H) (H) 1.5" and 2", thread connection 0.0-50 0 50 100 150 200 Temperature ( C) process pressure/temperature derating curves Siemens FI 01 2018 /205

Dimensional drawings with polypropylene shielded rod antenna PTFE rod antenna, threaded Threaded connection PTFE rod, external shield ½" NPT cable entry (or alternatively M20 x 1.5 cable gland) Threaded cover Nameplate Nameplate 158 (6.1) Std. 296 (11.7) min. Option: 6 (17.6) max. Std. 575 (22.6) min. Option: 725 (28.5) max. 15 (6) Enclosure/ electronics Locking ring Reference point Mounting thread Polypropylene rod antenna 165 (6.5) Reference point AISI 316, 2" NPT, R 2" (BSPT) or G 2" (BSPP) PTFE antenna Shield length (internal): Standard: 100 () Optional: 250 (10) 12 (16.3) 187 (7.) 17 (0.67) Reference point AISI 316, 2" NPT, R 2" (BSPT) or G 2" (BSPP) Antenna shield (inactive length) AISI 316 Active antenna (PTFE) Shield Length (S.L.): min. 100 () (customer specified) Overall Length (L): 37 (1.7) plus shielded length S.L. 187 (7.) 18 (0.7) L Horn antenna with flat faced flange Enclosure/electronics Reference point 187 (7.) Nameplate Locking ring Flange Ø80 (3) 131 Horn (5.16) 225.8 100 (8.89) () 150 (6) 200 (8) 325.1 (12.79), dimensions in mm (inch) /206 Siemens FI 01 2018

Level Measurement Circuit diagrams Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand programmer Notes: Gland may or may not be provided, depending on approval option. Shield for HART and PROFIBUS PA intrinsically safe versions only. 1. DC terminal shall be supplied from an SELV source in accordance with IEC 1010-1 Annex H. 2. All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable (1... 22 AWG) for HART version.. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. Part number: 7ML1930-1BK connections Siemens FI 01 2018 /207

Specials Selection and ordering data Specials Specials PROFIBUS PA Aluminum Enclosure Kit with electronics and covers (7ML522, 7ML523, 7ML52, 7ML525), calibrated for use with standard rod antenna with board stack, LUI display, 5.8 GHz, NPT cable inlet, approval option A, with HART A5E03617085 with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option E, with PROFIBUS PA communication, with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option A, with PROFIBUS PA communication, with board stack, LUI display, 6.3 GHz, M20 cable inlet, approval option C, with PROFIBUS PA communication, with board stack, LUI display, 6.3 GHz, NPT cable inlet, approval option C, with PROFIBUS PA communication, with board stack, LUI display, 5.8 GHz, NPT cable inlet, approval option E, with PROFIBUS PA communication, HART aluminum enclosure kit with electronics and covers (7ML522, 7ML523, 7ML52, 7ML525), calibrated for use with standard rod antenna A5E018320 A5E01830 A5E018356 A5E018357 A5E0183559 with board stack, LUI display, 6.3 GHz, NPT cable inlet, approval option B, with HART with board stack, LUI display, 5.8 GHz, NPT cable inlet, approval option C, with HART with board stack, LUI display, 6.3 GHz, NPT cable inlet, approval option E, with HART Sun shield for enclosure, stainless steel Horn Antenna Kits with mounting screws (no emitter supplied) A5E03617086 A5E03617087 A5E03617088 A5E3912556 with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option A, with HART with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option E, with HART with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option G, with HART with board stack, LUI display, 5.8 GHz, M20 cable inlet, approval option H, with HART A5E0295619 A5E0295620 A5E0295621 A5E0295622 80 mm (3 inch) horn antenna kit 25500K02A 100 mm ( inch) horn antenna kit 25500K03A 150 mm (6 inch) horn antenna kit 25500K05A Extension Kits for Horn Antenna with mounting screws 100 mm ( inch) extension kit for horn antenna 25501K0100A 150 mm (6 inch) extension kit for horn antenna 25501K0150A 200 mm (8 inch) extension kit for horn antenna 25501K0200A 250 mm (10 inch) extension kit for horn antenna 25501K0250A 500 mm (20 inch) extension kit for horn antenna 25501K0500A 1 000 mm (0 inch) extension kit for 25501K1000A horn antenna /208 Siemens FI 01 2018

Level Measurement Specials Specials Specials Flanged Rod Antenna Kit with 316L stainless steel flat faced flanges PTFE Rod Antenna Kit (100 mm shield) with 316L stainless steel 2" pipe thread process connection Flanged PTFE rod antenna kit, 2" ASME, 150 lb. See drawing 51003 on http://www.siemens.com/radar 1)) Flanged PTFE rod antenna kit, DN 50 PN 16. See drawing 51003 on http://www.siemens.com/radar 1)) Flanged PTFE rod antenna kit, JIS 10K DN 50. See drawing 51003 on http://www.siemens.com/radar 1)) PTFE Rod Antenna Kit with 316L stainless steel 1½" pipe thread process connection 51003K020AAAA 51003K050AJAA 51003K050AOAA PTFE rod antenna shielded kit, 2" NPT 316L stainless steel process connection, FKM O-ring, 100 mm 316L stainless steel shield. See drawing 51002 on http://www.siemens.com/radar 3)) PTFE rod antenna shielded kit, R 2" (BSPT), EN 10226 316L stainless steel process connection, FKM O-ring, 100 mm 316L stainless steel shield. See drawing 51002 on http://www.siemens.com/radar 3)) PTFE rod antenna shielded kit, 2" G 316L stainless steel process connection, FKM O-ring, 100 mm 316L stainless steel shield. See drawing 51002 on http://www.siemens.com/radar 3)) 51002K0100AAA 51002K0100BAA 51002K0100CAA PTFE rod antenna kit, R 1½" (BSPT), EN 10226 316L stainless steel process connection, FKM O-ring; see drawing 5100 on http://www.siemens.com/radar ) 5100K2AAA Horn Antenna Kit with 316L stainless steel flat faced flange, with PTFE emitter (without waveguide) PTFE rod antenna kit, 1½" G 316L stainless steel process connection, FKM O-ring; see drawing 5100 on http://www.siemens.com/radar ) PTFE Rod Antenna Kit with 316L stainless steel 2" pipe thread process connection 5100K3AAA Horn antenna kit, 2" ASME 316L stainless steel flange 3 inch horn, PTFE emitter 1)) Horn antenna kit, 2" ASME 316L stainless steel flange inch horn, PTFE emitter 1)2) Horn antenna kit, 2" ASME 316L stainless steel flange 6 inch horn, PTFE emitter 1)2) 51006K020AAAA 51006K020AABA 51006K020AACA Horn antenna kit, 2" ASME 316L stainless steel flange 8 inch horn, PTFE emitter 1)2) 51006K020AADA Horn antenna kit, DN 50 PN 16 316L stainless steel flange 80 mm horn, PTFE emitter 1)2) 51006K050AJAA PTFE rod antenna kit, 2" NPT 316L stainless steel process connection, FKM O-ring; see drawing 51005 on http://www.siemens.com/radar ) PTFE rod antenna kit, R 2" (BSPT), EN 10226 316L stainless steel process connection, FKM O-ring; see drawing 51005 on http://www.siemens.com/radar ) 51005K1AAA 51005K2AAA Horn antenna kit, DN 50 PN 16 316L stainless steel flange 100 mm horn, PTFE emitter 1)2) Horn antenna kit, DN 50 PN 16 316L stainless steel flange 150 mm horn, PTFE emitter 1)2) Horn antenna kit, DN 50 PN 16 316L stainless steel flange 200 mm horn, PTFE emitter 1)2) 51006K050AJBA 51006K050AJCA 51006K050AJDA PTFE rod antenna kit, 2" G 316L stainless steel process connection, FKM O-ring; see drawing 51005 on http://www.siemens.com/radar ) 51005K3AAA Siemens FI 01 2018 /209

Specials Specials PTFE flanged rod antenna kit with 316L stainless steel shield and 316L stainless steel flat faced flange 3" ASME 150 lb 316L stainless steel flange, 100 mm 316L stainless steel shield. 1)) DN 80 PN 16 316L stainless steel flange, 100 mm 316L stainless steel shield. 1)) 3" ASME 150 lb 316L stainless steel flange, 150 mm 316L stainless steel shield. 1)) DN 80 PN 16 316L stainless steel flange, 150 mm 316L stainless steel shield. 1)) 3" ASME 150 lb 316L stainless steel flange, 200 mm 316L stainless steel shield. 1)) DN 80 PN 16 316L stainless steel flange, 200 mm 316L stainless steel shield. 1)) 3" ASME 150 lb 316L stainless steel flange, 250 mm 316L stainless steel shield. 1)) DN 80 PN 16 316L stainless steel flange, 250 mm 316L stainless steel shield. 1)) PTFE grease Kit, PTFE grease, 5 Dupont 1 GR Polypack Cable gland One metallic cable gland M20 x 1.5, rated -0... +80 C (-0... +176 F), HART One metallic cable gland M20 x 1.5, rated -0... +80 C (-0... +176 F), PROFIBUS PA Ex-proof plugs Ex-proof plugs kit, 1/2" NPT, qty 5 Ex-proof plugs kit, M20, qty 5 5101K0100AAA 5101K0100EJA 5101K0150AAA 5101K0150EJA 5101K0200AAA 5101K0200EJA 5101K0250AAA 5101K0250EJA A5E01151626 7ML1930-1AP 7ML1930-1AQ A5E39979991 A5E39979992 1) Available in flange sizes including ASME, DIN and JIS. Please consult a local sales person for details. 2) Available with no pressure rating. Please consult a local sales person for details. 3) Available in other shield lengths. Please consult a local sales person for details. ) Available with Pressure rating. Please consult a local sales person for details. Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. /210 Siemens FI 01 2018