CS-2000/2000A. Spectroradiometer NEW

Achieving 100,000 : 1 contrast measurement

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Ultimate and Versatile 2D Spectroradiometer is finally released!

ILLUMINANCE METER T-10 Series

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

Illuminance Meter. series

Spectroradiometer series NEW

Spectroradiometer specbos 1201

Konica Minolta LS-110 Specs Provided by

Ultra low luminance measurement performance of the industry's top-level.

Broadbandradiometer specbos 1211

ILLUMINANCE METER T-10 Series

Spectrophotometer CM-3630 PaperControl Software

ILLUMINANCE METER LUMINANCE METER CHROMA METER T-10A /T-10MA/ T-10WSA/T-10WLA CL-200A CL-500A LS-100/LS-110 CS-100A CS-200

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

Contents. Contents. Part 4. Specification. Part 1. Feature. Feature Merit Configuration. Specification Dimension Diagram

Gamma Scientific Display Measurement Systems

Miniaturized Spectroradiometer

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

JETI Specbos Instruments

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

The new Konica Minolta DiMAGE Scan Dual IV film scanner

We bring quality to light. MAS 40 Mini-Array Spectrometer

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

SPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control

Imaging Photometer and Colorimeter

Nikon COOLSCAN V ED Major Features

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

COLORMUNKI DISPLAY & i1display PRO

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

DiMAGE SCAN ELITE 5400 II

High Speed, Multi-point Laser Displacement Sensor HL-D3 SERIES. panasonic.net/id/pidsx/global

SPECTROPHOTOMETER CM-2600d

Torque Station Pro TS-7700 System

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

Color Measurement with the LSS-100P

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Nikon SUPER COOLSCAN 5000 ED Major Features

185sec. 38sec. 20sec. Outstanding Image Quality with Amazing Scan Speeds

Microscope-Spectrometer

F400. Detects subtle color differences. Color-graying vision sensor. Features

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

Color & Graphics. Color & Vision. The complete display system is: We'll talk about: Model Frame Buffer Screen Eye Brain

Photometry for Traffic Engineers...

The Science Seeing of process Digital Media. The Science of Digital Media Introduction

COLOR and the human response to light

CHROMA METER CS-200. Instruction Manual. Please read before using this instrument.

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

Huvitz Digital Microscope HDS-5800

VIVID D Digitizing - Breakthrough in Process Innovation

COLOR. and the human response to light

Photometry for Traffic Engineers...

Digital Microscope. User Manual

CS 548: Computer Vision REVIEW: Digital Image Basics. Spring 2016 Dr. Michael J. Reale

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

Visual Perception. Overview. The Eye. Information Processing by Human Observer

LED Tester BTS256-LED

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

Digital Image Processing

COOLPIX " Scene Modes. Zoom-Nikkor Lens. Effective Megapixels. Macro Mode OPTICAL

HS-1800 Specifications

SIM University Color, Brightness, Contrast, Smear Reduction and Latency. Stuart Nicholson Program Architect, VE.

GL spectis 1.0 Touch The world s first smart spectrometer.

Non-contact 3D digitizer suitable for industrial applications requiring high accuracy and reliability

Coaxial Lights LFV3 series

QM-Data200 and Vision Unit

A World of Color. Session 4 Color Spaces. OLLI at Illinois Spring D. H. Tracy

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

STUDY NOTES UNIT I IMAGE PERCEPTION AND SAMPLING. Elements of Digital Image Processing Systems. Elements of Visual Perception structure of human eye

LITE-ON TECHNOLOGY CORPORATION

Images. CS 4620 Lecture Kavita Bala w/ prior instructor Steve Marschner. Cornell CS4620 Fall 2015 Lecture 38

Instruction Manual of Luminance and Spectral Radiance Calibrations

CAS 120. CCD Array Spectrometer. Two Global Leaders. One Complete Solution.

Visibility, Performance and Perception. Cooper Lighting

SCATT Biathlon shooting trainer User s Manual

PR-655 PR-670 PR-680 and PR-680L SpectraScan

VIVID D Digitizing - Breakthrough in Process Innovation

BTS2048-VL-CP-ILED-B-IS-1.0-HL

MK350 Portable Spectrometer

12/02/2017. From light to colour spaces. Electromagnetic spectrum. Colour. Correlated colour temperature. Black body radiation.

Reports. Eye-One. Evaluation of Gretag Macbeth. Brent Cavanaugh - Updated by Paul Huhtala Updated NOVEMBER 2005

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Fein. High Sensitivity Microscope Camera with Advanced Software 3DCxM20-20 Megapixels

Contrast Sensors. SICK The pioneer in contrast sensors for more than 60 years

Digital Image Processing

CUBE. Diode Laser System FEATURES & BENEFITS

LED 81x. Test Sockets for High-Power LEDs. Two Global Leaders. One Complete Solution.

ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

LINEARPYROMETER LP4. Technical Documentation KE November TN

New Product Information. Minolta Dimâge Scan Multi

Transcription:

Spectroradiometer CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. 15

World's top level capability to detect extremely low luminance * As a polychromator type spectroradiometer (As of March 014) 1,000,000:1 contrast measurement is now possible! * When the peak luminance is 500 cd/m CS-000A Opening the curtain on a new age in which people can experience theater ambiance with their home televisions. The Spectroradiometer CS-000A enables high-accuracy mega-contrast measurements of the extremes from delicate shadows to glittering wavefronts which are key to image reproduction performance. This newest addition to the Konica Minolta lineup will contribute greatly to research and development as well as quality control of the most advanced FPDs. 0.0005 cd/m opens new worlds With an additional decimal place of performance in measuring low luminosity even compared to our CS-000, which was awarded the ADY 008 grand prize, the CS- 000A helps open up a new stage of display development by enabling the measurement of contrast ratios up to 1 million to 1*1 which is being targeted by the latest FPD technology. *1 Maximum luminance 500 cd/m Measurement example: Measurement of an organic EL illumination panel during development Instruments that push the extreme boundaries of practical application and cost performance to support design and development work. CS-000 Highly accurate measurement of luminances as low as 0.003 cd/m Konica Minolta's original optical design and signal-processing technologies provide accurate measurement of luminance/ chromaticity down to extremely low luminances of 0.003 cd/m. Low-luminance measurements: From 0.003 cd/m Measurement accuracy: ±% (Luminance) Quick measurements even at low luminance Designed to thoroughly eliminate mechanical and electrical noise factors, the CS-000 makes quick measurements with good repeatability possible even at low luminance levels. Measurement time for 1 cd/m : Approx. 5 sec. (FAST mode) * Konica Minolta's previous model CS-1000: Approx. 13 sec. Low polarization error The polarization error generated when using a reflection-type diffraction grating has been minimized to % (measuring angle: 1 ). This ensures more stable measurements of display devices that use polarization, such as LCDs. Half bandwidth of 5 nm A half bandwidth of 5 nm, which is required for colorimetry (JIS Z 874-1997, CIE1-1996), is ensured for the entire wavelength range, allowing accurate chromaticity measurements. Selectable measuring angle for measurement of tiny areas The CS-000 enables you to select the optimum measuring angle according to the application. Measuring angle selection: 1, 0., 0.1 Minimum measuring area: ø0.1 mm ( when the optional closeup lens is attached) Practical design reliable operation at temperatures in actual work environments. 30 seconds. (Measuring angle: 1 ; Target luminance: 5 cd/m or more; 3 C) Stable measurement even of periodic light sources 1. Internal synchronization measurement Measurement at numerically-input frequency. External synchronization measurement Measurement with line input of vertical synchronization signal to instrument 3. Multi-integration mode measurement Measurement for reducing variations due to unsynchronized measurements or synchronized measurements of sources having irregular light-emission cycles

Measurements of various objects are possible by selecting the best-suited measuring angle. 1 is suitable for 0. is suitable for 0.1 is suitable for Typical targets such as middle- and large-size display units digital cameras used in airplane cockpits Small light sources such as LEDs and other light sources Extremely small light sources or distant lights Measuring diameter viewed through viewfinder LCD pixels Measurement Examples PDP LCD Organic EL Close-up lens for measurement of even tinier areas (Optional accessory) Optional close-up lens allows measurements of areas as tiny as ø0.1 mm. Not only general display units but also small targets can be measured. Measuring distance vs. measuring area (Units: mm) Measuring distance Measuring angle 1 0. 0.1 When a close-up lens 55.0 ø1.00 ø0.0 ø0.10 is attached 70.9 ø1.39 ø0.8 ø0.14 350 ø5.00 ø1.00 ø0.50 500 ø7.78 ø1.56 ø0.78 1,000 ø16.66 ø3.33 ø1.67,000 ø34.18 ø6.84 ø3.4 * The measuring distance is the distance from the objective lens or the end of the metal frame of the close-up lens.

Comparison of repeatability * Comparison with Konica Minolta's previous model CS-1000 for target luminance of 0.1 cd/m * The y-axis indicates the logarithm when the average of the CS-000 measured values is assumed to be 1. Luminance ( Lv ) Chromaticity ( x ) Chromaticity ( y ) Average repeatability (logarithm) 100 10 1 0.1 CS-1000 Difference: 4.7 times CS-000 Average repeatability (logarithm) 100 10 1 0.1 CS-1000 Difference: 34.7 times CS-000 Average repeatability (logarithm) 100 10 1 0.1 CS-1000 Difference: 4.3 times CS-000 High repeatability achieved by an instrument design which thoroughly eliminated mechanical and electrical noise factors. Scotopic vision measurement It is known that the sensitivity of human vision shifts to blue region in dark environments, but past instruments did not have scotopic measurement function. CS-000A achieves sufficient capability to make it possible with CS-S10w Professional (standard accessory). Scotopic vision In the human eye, there are types of photoreceptor cells, which are cone cells and rod cells. Cone cells are sensitive to color and rod cells are sensitive to only brightness. As brightness decreases, the activity of rod cells becomes stronger, and the condition in which only rod cells are working is called scotopic vision. The peak of spectral luminous efficiency of scotopic vision is shifted toward blue from the green peak of photopic vision (vision under brighter conditions) and thus blue objects are perceived to be brighter. CIE Spectral luminous intensity 1. 1.0 0.8 0.6 0.4 0. 0.0 380 411 44 473 504 535 566 597 68 659 690 71 75 Measured luminance vs. Measurement times (Units: sec.) Luminance (cd/m ) NORMAL mode FAST mode 0.003 43 35 0.01 43 35 0.1 155 7 1 19 5 10 4 4 300 3.7 3.7 Measurement subject: Standard light source A * All time indications are approximate values. Using as a reference instrument CS-000/CS-000A can be used as a reference instrument for Konica Minolta's Illuminance Meters in various industrial fields. CS-00 CS-100A Reference instrument CA-500A CA-310 System Diagram Standard accessories Optional accessories ND filter (1/10) CS-A33 (1/100) CS-A34 Lens Cap Screw for focus ring look CS-A38 CS-000 main unit Calibration certificate 3-point calibration certificate Eyepiece with ND filter CS-A1 CCD Camera Adapter CS-A36 Close-up lens CS-A35 USB cable ( m) CS-A3 Pan Head CS-A4 AC Adapter White Calibration Plate CS-A5 (without data) CS-A5 (with data) CS-A5 (with data and calibration certificate) Storage Case CS-A30 Tripod CS-A3 PC (commercially available) Data Management Software CS-S10w Professional Edition

Easy operation with color LCD screen and simple operation panel The color LCD screen and operation panel are located at the rear of the instrument. The simply arranged operation panel enables intuitive selection of necessary functions. Color space mode screen Lv 30.79 x 0. 311 y 0. 3404 Lv 30.79 T 607K duv +0. 005 cd m cd m Color LCD screen Menu screen Simple operation The desired function can be called intuitively. Easy connection via USB Data Management Software CS-S10w Professional (Standard accessory) With this software, the CS-000 and CS-000A can be controlled from a personal computer to display measured data in various graphs or lists, to transfer data to spreadsheet software, or to copy-and-paste data. CS-S10w offers various data management, analysis and evaluation options to assist in research and development or quality control. Template showing xy and u'v' chromaticity diagrams Multiple data objects can be copied and pasted to spreadsheet software. is a trademark or registered trademark of Microsoft Corporation in the USA and other countries. is a trademark of Intel Corporation in the USA and other countries. Display Color space Calculation Mode selection Spectral graph, spectral data list, chromaticity diagram L v xy, L v u'v', L v T uv, XYZ, dominant wavelength, excitation purity, scotopic luminosity Four basic arithmetic operations and function processing of spectral data Normal mode, contrast mode, RGB mode, RGB & contrast mode, object color mode Instrument control Averaging measurement, interval measurement, user calibration Data management Reading/saving files; managing data by using folders; creating, saving and reading templates with various graphs designed and laid-out by users; displaying data with graphs Data evaluation Observer/illuminant setting, color rendering property evaluation, statistic value display for each folder, box tolerance setting, multiple point setting for display evaluation, non-uniformity (mura) display, contrast display, polygonal tolerance setting System requirements OS Windows XP Professional 3 bit SP3, 64 bit SP Windows 7 Professional 3 bit, 64 bit Windows 8 Pro 3 bit, 64 bit CPU Pentium III 600 MHz equivalent or faster Memory 18 MB or more (56 MB or more recommended) Hard disk 60 MB or more of free space for installation Display 1,04 x 768, 56 colors minimum Other CD-ROM drive for installation, USB port for instrument connection

65 Main specifications of CS-000/000A Model CS-000/000A Wavelength range 380 to 780 nm Wavelength resolution 0.9 nm/pixel Display wavelength bandwidth 1.0 nm Wavelength precision ±0.3 nm (Median wavelength: 435.8 nm, 546.1 nm, 643.8 nm; Hg-Cd lamp) Spectral bandwidth 5 nm or less (half bandwidth) Measuring angle (selectable) 1 0. 0.1 Measurement luminance CS-000 0.003 to 5,000 cd/m 0.075 to 15,000 cd/m 0.3 to 500,000 cd/m range (Standard light source A) CS-000A 0.0005 to 5,000 cd/m 0.015 to 15,000 cd/m 0.05 to 500,000 cd/m Minimum measuring area ø5 mm ø1 mm ø0.5 mm (ø1 mm when using close-up lens) (ø0. mm when using close-up lens) (ø0.1 mm when using close-up lens) Minimum measuring distance 350 mm (55 mm when using close-up lens) Minimum spectral radiance display 1.0x10-9 W/sr, m, nm Accuracy: Luminance (Standard light source A)*1 ±% x,y : ±0.003 (0.003 to 0.005 cd/m ) x,y : ±0.003 (0.075 to 0.15 cd/m ) x,y : ±0.003 (0.3 to 0.5 cd/m ) Accuracy: Chromaticity x,y : ±0.00 (0.005 to 0.05 cd/m ) x,y : ±0.00 (0.15 to 1.5 cd/m ) x,y : ±0.00 (0.5 to 5 cd/m ) (Standard light source A)*1 x : ±0.0015 x : ±0.0015 x : ±0.0015 (0.05 cd/m (1.5 cd/m (5 cd/m 0.4% (0.003 to 0.05 cd/m Repeatability: Luminance (σ) ) 0.4% (0.075 to 1.5 cd/m ) 0.4% (0.3 to 5 cd/m ) 0.3% (0.05 to 0.1 cd/m (Standard light source A)* ) 0.3% (1.5 to.5 cd/m ) 0.3% (5 to 10 cd/m ) 0.15% (0.1 to 5,000 cd/m ) 0.15% (.5 to 15,000 cd/m ) 0.15% (10 to 500,000 cd/m ) CS-000 CS-000A Repeatability: Chromaticity (σ) (Standard light source A)* x,y : 0.00 (0.003 to 0.005 cd/m ) x,y : 0.001 (0.005 to 0.1 cd/m ) x,y : 0.0006 (0.1 to 0. cd/m ) x,y : 0.0004 (0. to 5,000 cd/m ) x,y : 0.00 (0.075 to 0.15 cd/m ) x,y : 0.001 (0.15 to.5 cd/m ) x,y : 0.0006 (.5 to 5 cd/m ) x,y : 0.0004 (5 to 15,000 cd/m ) x,y : 0.00 (0.3 to 0.5 cd/m ) x,y : 0.001 (0.5 to 10 cd/m ) x,y : 0.0006 (10 to 0 cd/m ) x,y : 0.0004 (0 to 500,000 cd/m ) x,y :±0.00 (0.001 to 0.05 cd/m Accuracy: Chromaticity ) x,y : ±0.00 (0.05 to 1.5 cd/m ) x,y : ±0.00 (0.1 to 5 cd/m ) x : ±0.0015 x : ±0.0015 x : ±0.0015 (Standard light source A)*1 (0.05 cd/m (1.5 cd/m (5 cd/m 1.5% (0.0005 to 0.001 cd/m ) 1.5% (0.015 to 0.05 cd/m ) 1.5% (0.05 to 0.1 cd/m ) Repeatability: Luminance (σ) 0.7% (0.001 to 0.003 cd/m ) 0.7% (0.05 to 0.075 cd/m ) 0.7% (0.1 to 0.3 cd/m ) (Standard light source A)* 0.5% (0.003 to 0.05 cd/m ) 0.15% (0.05 to 5,000 cd/m ) 0.5% (0.075 to 1.5 cd/m ) 0.15% (1.5 to 15,000 cd/m ) 0.5% (0.3 to 5 cd/m ) 0.15% (5 to 500,000 cd/m ) Repeatability: Chromaticity (σ) (Standard light source A)* x: 0.003 y:0.0035 (0.001 to 0.003 cd/m ) x: 0.001 y:0.0015 (0.003 to 0.1 cd/m ) x,y: 0.0006 (0.1 to 0. cd/m ) x,y: 0.0004 (0. to 5,000 cd/m ) x: 0.003 y: 0.0035 (0.05 to 0.075 cd/m ) x: 0.001 y: 0.0015 (0.075 to.5 cd/m ) x,y: 0.0006 (.5 to 5 cd/m ) x,y: 0.0004 (5 to 15,000 cd/m ) x: 0.003 y: 0.0035 (0.1 to 0.3 cd/m ) x: 0.001 y: 0.0015 (0.3 to 10 cd/m ) x,y : 0.0006 (10 to 0 cd/m ) x,y : 0.0004 (0 to 500,000 cd/m ) Polarization error 1 : % or less (400 to 780 nm); 0.1 and 0. : 3% or less (400 to 780 nm) Integration time Fast: 0.005 to 16 sec.; Normal: 0.005 to 10 sec. Measurement time CS-000 : Approx. sec. minimum (Manual mode) to 43 CS-000A : Approx. sec. minimum (Manual mode) to sec. maximum (Normal mode) 47 sec. maximum (Normal mode) Color space L v xy, L v u'v', L v TΔuv, XYZ, spectral graph, dominant wavelength, excitation purity, scotopic luminosity (with CS-S10w Professional) Interface USB 1.1 Operation temperature/ CS-000 : 5 to 35 C, relative humidity 80% or less with CS-000A : 5 to 30 C, relative humidity 80% or less with humidity range no condensation no condensation Storage temperature/humidity range 0 to 35 C, relative humidity 80% or less with no condensation Power AC Adapter (100-40 V, 50/60 Hz) Current consumption Approx. 0 W Size (W x H x D) 158 x 00 x 300 mm (Main unit), ø70 95mm (Lens) Weight 6. kg *1: Average of 10 measurements in Normal mode at a temperature of 3± C and a relative humidity of 65% or less. *: 10 measurements in Normal mode at a temperature of 3± C and a relative humidity of 65% or less. Dimensions (Units: mm) 67.4 Filter thread diameter: ø5 10.5 19 50 47 79 158 Reference for measuring distance 95.7 9.5 Mounting screw: M5, Depth: 6.5 Mounting screw: M5, ø15 Depth: 6.5 51 58.5 300 39 00 53 9 Optical axis Positioning pin hole (1): ø5, Depth: 4 70 170 190.4 90 Positioning pin hole (): Depth: 4 Tripod screw (ø3/8-inch screw) SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. are subject to change without notice. measurements difficult. For details, please contact your nearest Konica Minolta sales office or dealer. Certificate No : LRQ 0960094/A Registration Date : March 3, 1995 Certificate No : JQA-E-8007 Registration Date : March 1, 1997 94-489-10 BFEPK Printed in Japan