Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Rotary gear motor series AG8...

INSTRUCTION MANUAL (ATEX / IECEx)

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Electronic Air / Fuel Ratio Control System

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

658 Current to Position Converters

BFS / BFSM SERIES Installation & Maintenance Manual

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Spring Return DuraDrive Proportional Actuator

Technical Instructions Document No EA GQD June 23, OpenAir

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Overview of types. Technical data

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

AC 01.2 HART Technical data Actuator controls

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Technical Information Nivector FTC968, FTC968Z

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Functional data Factory settings Variable Settings

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Isolators A3/1. Vibration Transducer Supply Unit Series

AE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models

Technical data. Parameterisable damper actuator in the

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Universal Controller

RS /M MZ SERIES

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Rudder or propeller angular position transmitter KINAX WT720

Operating Instruction

Digital Input Output Module for Zone 1 Series 9470/32

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Industrial actuation made easy

RMA42. Technical Information

FEATURES OPTIONAL FEATURES

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

LAUREL ELECTRONICS, INC.

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

OPERATION MANUAL. Spring Return Actuator. Electrical Actuator. September, st

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn.

Non-Spring Return DuraDrive Modulating Actuator

Operating Instructions

RT-5005/5006/5007/5008

Positioner with HART Communication Type 3780

Digital Input Output Module for Zone 2 Series 9470/33

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Digital Input Output Module for Zone 2 Series 9470/33

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Electromotoric actuators for stroke valves

Trip amplifier, 1 channel

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Worcester Controls PB SMART PRODUCTS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

Rotary actuators for ball valves

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Actuators for modulating control AME 85, AME 86

General Purpose Drives

Sealed Interface Control: EC20300

Technical Documentation

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Level Limit Switch nivotester FTL 325 P

DCS-62 Series Spring Return Electronic Actuator Product Bulletin

Installation guide 971 SmartRadar LTi

SPEED CONTROL OPTIONS

AC 01.2 Modbus TCP/IP

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Power supply CP-D 24/4.2 Primary switch mode power supply

Type 3374 Electric Actuator

Transcription:

MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16

MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications...... 4 Operation MZ2, MZ3... 5 Operation MZ5... 8 Product information... 14 Ex-proof version..... 14 Standards and approvals.... 15 Description MZ servomotor is designed to operate VF and VFH butterfly valves for gas and air flow in combustion processes, with positioning by means of switching cams (MZ2, MZ3) or electronic control (MZ5). Features Electrical motor with multi-stage spur gearbox inside a metal housing. Provided with switching cams with adjusting screw. Its rugged and functional design allows a fast and easy installation. Available in Ex-proof version, for use in Zones 2 and 22, according to 2014/34/EU Directive (ATEX). Additional features for MZ5 series High positioning precision performed by a 16-bit microcontroller. Status LEDs and position indicator of the motor visible externally. Two push-buttons for manual adjustment of the position. Two push-buttons to save min./max. positions. Analogue input and output signals for electronic positioning. The same unit is suitable for 230-110-24V. Adjustable opening time from 7s up to 60s. Provided with connection for external programming terminal. WARNING This control must be installed in compliance with the rules in force. 2-15

Functioning and application - In case of combustion process being regulated by combustion air modulation, VF valves with servomotor can be used, coupled to another butterfly valve manually operated (available graduated scale and locking screw) to setup high-fire rate of the burner. VF..MZ Fig. 1 VF..MZ - In case of combustion process with excess of air or gas, VF butterfly valve can be used, coupled to a Lambda sensor for ratio correction. VF..MZ Fig. 2 - In case of combustion process with pre-heated air, VFH butterfly valve can be used with MZ servomotor. VFH..MZ Fig. 3 WARNING Location and mode of installation must be in compliance with local rules in force. 3-15

Technical specifications Tab. 1 Servomotor type Overall dimensions See fig. 4 MZ2: 2-point control by means of switching cams MZ3: 3-point control by means of switching cams MZ5: Continuous adjustment of position by analogue signals Weight 2 Kg Rotation angle 0 / 90 Position repeatability (MZ5) Ambient temperature Voltage rating ±0,25-15 C / +60 C 230VAC 50/60Hz 110VAC 50/60Hz 24V AC/DC Voltage tolerance -15% / +10% Power consumption 5 VA Protection class Class I (EN 60335-1) Enclosure IP65 (EN 60529) Cable gland M20x1,5 for cable O.D. 7 / 12 mm (EN 62444) Wires cross-section Max Torque Operating time (0-90 ) 2,5 mm 2 max MZ2-3: 3 Nm (holding torque 3 Nm) MZ5: 5 Nm (holding torque 5 Nm) MZ510: 10 Nm (holding torque 5 Nm) MZ2-3: 30s (fixed) MZ5: from 7s up to 60s (adjustable) Position switches electrical rating Voltage 250VAC Resist. Load 2A Lamp. Load 0,3A Induct. Load 0,3A Potentiometer (MZ2-3) (optional) 1KΩ 0,5W max (±2% linearity) Analogue inputs (MZ5) Signal type Overload max. Load impedance 0-10V 24Vdc 9,9KΩ 0-20mA 25mA 100Ω 4-20mA 25mA 100Ω Analogue outputs (MZ5) Signal type Load max. 0-10V 10mA 4-20mA 350Ω Fig.4 Adapter set for VF butterfly valve (Set M) Adapter set for VFH butterfly valve (Set MH) 4-15

Operation MZ2, MZ3 ELEKTROGAS Technical Sheet EE157-01/16 This unit is designed for basic applications that require a rotary movement between 0 and 90. It is controlled by a 3-point step signal (MZ3) or a 2-point step signal (MZ2). Inside the compact housing there is a synchronous electric motor, a gearbox and an electronical board. Fig.5-1 A Main terminal block F Automatic/ Manual switch (S1) B Position indicator G Opening/ Closing switch (S2) C Pot terminal block (optional) H Plastic cover D Cams (C1, C2, C3, C4) I Relay for 2-point control (optional) E Motor connection plug J Synchronous AC motor The shaft rotation angle can be controlled via switching cams (C1, C2) and any position can be freely selected within the defined operating range. The current position can be monitored via an integrated potentiometer (optional). The servomotor is provided with a switch for manual adjustment of the position during the commissioning and with two auxiliary cams (C3, C4) which activate the micro-switches for the monitoring of intermediate positions or the control of external devices. 5-15

Fig. 5-2 N 2P (0 >90 ) L 1 2P L1 3P (90 >0 ) L 1 3P (0 >90 ) L 1 MAN L1 MAX MIN Connections (1) : Neutral (2) : Line voltage for opening function in 2-point control (MZ2) (3) : Main voltage in 2-point control (MZ2) (4) : Line voltage for closing function in 3-point control (MZ3) (5) : Line voltage for opening function in 3-point control (MZ3) (6) : Line voltage for manual control (opening/ closing) (7) : Output signal for maximum position (8) : Output signal for minimum position (9,10,11) : Contact activated directly by the cam C3 for the monitoring of intermediate positions (12,13,14): Contact activated directly by the cam C4 for the monitoring of intermediate positions (15,16,17): Feedback potentiometer (optional) Manual mode For a simplified commissioning, the actuator can be operated manually. The manual mode is useful to determine the operating positions for the process, such as the High/Low fire positions. To enter in the manual mode shift the switch S1 upward. After applying power to the terminal 6, it's possible to move the valve toward the 90 posi tion (counter clockwise rotation seen from the top), or toward the 0 position (clockwise rotation seen from the top), by means of the switch S2. Remove the adjustment tool from the cam before attempting to actuate the servomotor. 6-15

Setting of the MIN and MAX positions From factory the minimum position is set up to 0 a nd the maximum is set up to 90. Different positions can be adjusted by means of the cams C1 and C2. Do not exceed the limits 0-90 when the potentiome ter is installed. Automatic mode To enter in the automatic mode shift the switch S1 downward. 2-point control (MZ2) Apply permanent power to the terminal 3. It's possible to move the valve toward the 90 position (counter clockwise rotation seen from the top), applying line voltage to the terminal 2. The rotation stops when the maximum position is reached (cam C2). If the voltage to the terminal 2 is disconnected the servo moves toward the 0 position (clockwise rotation seen from the top). The rotation stops when the minimum position is reached (cam C1). 3-point control (MZ3) It's possible to move the valve toward the 90 posi tion (counter clockwise rotation seen from the top), applying line voltage to the terminal 5. The rotation stops when the maximum position is reached (cam C2 switches the line voltage to the terminal 7) or when the voltage to the terminal 5 is disconnected. It's possible to move the valve toward the 0 posit ion (clockwise rotation seen from the top), applying line voltage to the terminal 4. The rotation stops when the minimum position is reached (cam C1 switches the line voltage to the terminal 8) or when the voltage to the terminal 4 is disconnected. Potentiometer A feedback potentiometer can be fitted to monitor the current position of the servomotor. The change in position of the actuator is transmitted to the potentiometer wiper by means of a gear set and can be measured as a changing voltage. It must be connected as a voltage divider with an high impedance load. The potentiometer cannot be retrofitted, but it must be factory installed as optional. 7-15

Operation MZ5 This unit is designed for all applications that require high precision control of rotary movement between 0 and 90. Inside the compact servo drive housing there is a DC electric motor, a gearbox and a control unit with a 16-bit microcontroller. Fig.6-1 A Main terminal block J Warning LED2 (red) B Analogue signals K Status LED3 (green) C DIP switch L MIN push button (B4) D Cams (C1, C2) M Board connector for Terminal (T1) E Closing push button (B1) N Hysteresis control F Automatic/ Manual switch (S1) O Direct motor driving G Manual operation LED1 (green) P Position indicator H Opening push button (B2) Q Plastic cover I MAX push button (B3) R DC motor The shaft rotation angle can be controlled via analogue signals and any position can be freely selected within the defined operating range. The hysteresis can be adjusted with a potentiometer in order to suppress interferences in the input signal. The current position can be monitored via output analogue signals. MZ5 servomotor is provided with buttons for manual adjustment of the position and to save minimum/maximum limits. Some LEDs visible even externally, show the current status of the unit (e.g. manual operation, memorization, errors, etc.). The most of settings can be made with an on board DIP switch (e.g. selection of analogue signals, sense of rotation, behaviour in the event of cable break, two-point operation). In the back side is also available a connection for the external programming terminal (T1), which can be used to set advanced features of the unit, to monitor some parameters (e.g. temperature, errors) or to upload new software releases. On the back side is located a socket to connect a 5-12VDC power supply and perform direct motor driving, by-passing the control unit. It can be useful when either the control unit is failed or electrical power is missing and the valve must be operated anyway. The servomotor is also provided with two auxiliary cams which activate the micro-switches for the monitoring of intermediate positions or the control of external devices. 8-15

Opening (B2) Automatic/ Manual (S1) Closing (B1) N 230-110V COM MIN MAX 24V N 0 Output Direct motor driving Terminal (T1) Hysteresis MIN (B4) LED3 LED2 MAX (B3) LED1 Setpoint Fig.6-2 Connections (1,2) : Main power supply of the device within 110Vac and 230Vac. (3,4,5) : Contacts activated directly by the cam C1 for the monitoring of intermediate positions. (6,7,8) : Contacts activated directly by the cam C2 for the monitoring of intermediate positions. (9,10,11) : Contacts activated by the microprocessor to monitor the saved positions of minimum and maximum. (12,13) : Auxiliary power supply 24Vac/dc. (14,15,16) : Input and output analogue signals for the control of the position. Make sure that the reference potential of 24V is the same as the analog input signal. Manual mode For a simplified commissioning, the actuator can be operated manually. The manual mode is useful to determine the operating positions for the process, such as the High/Low fire positions. To enter in the manual mode shift the switch S1 upward (LED1 lights up). Now it's possible to move the valve toward the 90 position (counter clo ckwise rotation seen from the top), by pressing the button B2, and to move the valve toward the 0 position (clockwise rotation seen from the top), by pressing the button B1. The initial rotation speed is 0.25 RPM, this lets operator perform an accurate adjustment of position. If the button is pressed for more than 4 seconds the rotation speed shifts to 1 RPM. 9-15

Setting of the MIN and MAX positions In manual mode it's possible to save current position as MIN (MAX) by pressing button B4 (B3) for more than 3 seconds (shorter pressing are not considered). When the position is saved, LED3 lights up permanently and the button may be released. MAX position can not be lower than MIN saved position (and vice versa). In this case the position won't be saved and an alarm will go up (see "Alarms Chart") until a new proper position is saved. Running time setting (continuous) Factory standard setting for running time is 30s for 0-90. However, requested running time is setup in the factory prior despatch according to customer s order information. In case of need, it can be modified on the field by the user by means of terminal T1 (optional) or in manual mode, according to following instructions. Press both B3 and B4 buttons at the same time, keeping the buttons pressed for the time required (LED3 lights up). Running time must be included between 7 s and 60 s, otherwise its value will not be saved and an alarm will go up (see "Alarms Chart") until a new proper time is saved. The adjusted running time will become operative as the user switches from manual mode back to automatic mode. Automatic mode In the automatic mode the angular position corresponds to the input analogue signal supplied by a setpoint device. Factory setting allows full range of operation (0-90 ) but, as above described, MIN and MAX position can be set within this range in manual mode. An output analogue signal proportional to angular position is also provided. Both input and output signals can be chosen between 0-10V, 4-20mA setting the proper DIP switch configuration (see "DIP Chart"). Behaviour without input signal (4-20mA) In the event of cable break or any other situation that a missing of input signal can happen, servomotor has to move in a defined mode. It's possible to set three different behaviour modes by the DIP switch: open position, closed position and stop (see "DIP Chart"). 2-point control The servomotor MZ5 can work as 2-point device by means of an external relay (dry contact), setting the proper DIP switch configuration (see "DIP Chart"). Main power supply must be also provided. Remote Control Unit Fig.7 If a voltage V is applied to the relay terminals (contact closed), the actuator opens. If no voltage is applied to the relay terminals (contact open), the actuator closes. 10-15

3-point control The servomotor MZ5 can work as 3-point device by means of two external relays (dry contacts) coupled with two resistors, setting the proper DIP switch configuration (see "DIP Chart"). Main power supply must be also provided. Remote Control Unit V1 0 90 V2 90 0 R1= 3,3 kω R2= 390 Ω (0,5 W) Fig. 8 The servomotor moves to MIN (0 ) or to MAX (90 ) wh en voltage is applied to the related terminal (contact closed). If the voltage is switched off, the servomotor remains in the current position and the holding torque keeps it still without any additional brake. Hysteresis and Filtration The input analogue signal is processed internally with a resolution of 12 bit, corresponding to 0,025% of full scale (i.e. 0,004mA on a 4-20mA range). In order to avoid constant corrections of the positions due to signal fluctuations or noise, the hysteresis can be modified by means of a potentiometer from 1 up to 124 LSB. Factory setting is 10 LSB. The analogue input is sampled every 1 ms (sampling rate) and a mean value is generated over 0,1s. This filtering can be prolonged by the terminal T1 (optional) up to 1s, but this also prolongs the response time to a change at the analogue input. 11-15

DIP chart = switch position Input analogue signal ON ON ON 1 2 3 4 5 6 7 8 9 10 0-10V 1 2 3 4 5 6 7 8 9 10 0-20mA 1 2 3 4 5 6 7 8 9 10 4-20mA Output analogue signal 1 2 3 4 5 6 7 8 9 10 0-10V ON 1 2 3 4 5 6 7 8 9 10 4-20mA ON Behaviour without input signal (4-20mA) 1 2 3 4 5 6 7 8 9 10 Stop ON 1 2 3 4 5 6 7 8 9 10 Open position (MAX) ON 1 2 3 4 5 6 7 8 9 10 Closed position (MIN) ON Sense of rotation ON 1 2 3 4 5 6 7 8 9 10 Right (counter clockwise seen from the top) ON 1 2 3 4 5 6 7 8 9 10 Inverted (clockwise seen from the top) Control type ON 1 2 3 4 5 6 7 8 9 10 Analogue signals 1 2 3 4 5 6 7 8 9 10 3-point control activated ON 1 2 3 4 5 6 7 8 9 10 2-point control activated ON 12-15

Operating state Normal operation Nr. Status LED3 GREEN Warning LED2 RED 1 Fast flashing Automatic mode State description Tab.2 2 Slow flashing Manual mode 3 Permanent light when position has been saved 4 Permanent light while buttons are being pressed Setting of the MIN and MAX positions (Manual mode) Running time setting (Manual mode) Fast flashing: 4 times per second Slow flashing: 1 time per second Alarms chart Alarm Nr. Status LED3 GREEN Warning LED2 RED Alarm type Description Cause 1 1 Flashing Warning Input signal is missing (4-20mA) Cable break or disconnected, remote control defective 2 2 Flashings Warning Invalid position Attempt to save an invalid position (e.g. MIN>MAX) Tab.3 3 3 Flashings Warning Invalid running time Attempt to save an invalid running time (out of 7-60s range) 4 4 Flashings Fault Motor fault Motor is defective 5 5 Flashings Warning Motor does not run Motor is disconnected, potentiometer is disconnected, torque is too high 6 6 Flashings Warning Motor overload Valve is blocked, direction of rotation is wrong 7 7 Flashings Fault Analogue signals defective Test of analogue signals has detected a malfunctioning 8 8 Flashings Warning High temperature Ambient temperature too high 9 9 Flashings Fault Unit defective Control unit defective, internal error 10 10 Flashings Warning Invalid position has been saved 11 11 Flashings Warning Invalid running time has been saved 12 12 Flashings Fault Potentiometer disconnected or loose Wrong move with T1 Wrong move with T1 - n-flashing (2 per second) followed by a longer pause (2 seconds) 13-15

Product information MZ2-3 MZ5 Model MZ2 = 2-point control (3 Nm) MZ3 = 3-point control (3 Nm) MZ5 = Analogue control (5 Nm) MZ510 = Analogue control (10 Nm) Tab.4 X = Ex-Proof execution Running time (1) 7 s 15 s 30 s 60 s 7...60 s continuous (2) Voltage A= 230VAC 50/60Hz B= 110VAC 50/60Hz C= 24VAC/DC Inputs 0-10 V 0-20 ma 4-20 ma Outputs P= potentiometer 0-10 V 0-20 ma 4-20 ma For more information about butterfly valves see their technical sheets. Standard Optional Adjustable Not available (1) to be specified if time is different from 30s and its setup has to be done in factory prior despatch (2) customized time can be set up by user Ex-proof version The servomotor can be provided in Ex-Proof version for use in Zones 2 and 22, according to 2014/34/EU Directive (ATEX): category protection mode II 3G, II 3D Ex nr IIA T4 Gc X (restricted breathing enclosure) Ex tc IIIC T135 C Dc X This version is provided with a 1/8" test port. After closing of the cover a restricted breathing test of the enclosure shall be performed (see the instructions sheet for ATEX installations). Fig. 9 14-15

Standards and approvals The product complies with the essential requirements of the following European Directives and their amendments: 2009/142/EC (Gas Appliances Directive) 2014/34/EU (ATEX) when shown upon the product 2014/30/EU (Electromagnetic Compatibility) 2014/35/EU (Low Voltage Directive) 2011/65/EU (RoHS II) Reg.-No 01MECH The product complies with the Technical Regulation TP TC 004/2011-016/2011-020/2011-032/2013 of Russia, Belarus and Kazakhstan. Certificate No.: TC RU Д-IT.PA01.B.21942 Quality Management System is certified according to UNI EN ISO 9001. Elektrogas is a brand name of: Elettromeccanica Delta S.p.A. Via Trieste 132 31030 Arcade (TV) ITALY The information in this document contains general descriptions of technical options available and based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced, without prior notice. tel +39 0422 874068 fax +39 0422 874048 www.delta-elektrogas.com info@delta-elektrogas.com Copyright 2016 All rights reserved 15-15