Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

Similar documents
Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Industrial actuation made easy

BERNARD CONTROLS ALWAYS BY YOUR SIDE. Invest in Confidence

BERNARD CONTROLS ALWAYS BY YOUR SIDE

SERIES 70 ELECTRIC ACTUATORS THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

SERIES 70 ELECTRIC ACTUATORS

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Electric Actuator. of innovated design. Introducing KIMAX CONTROLS INC. > Patented switch of manual & Motor operation. Clutchless manualoverride.

AC 01.2 HART Technical data Actuator controls

AE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models

Value Valves USA. Electric Actuator DOUBLE ACTING SPRING RETURN.

AC 01.2 Modbus TCP/IP

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

E l e c t r i c A c t u a t o r s

AE SERIES ACTUATORS. Electric Actuators. Standard Voltages 110/240/380/480V 24VAC/24VDC. Modulating Capable. 100% Duty Cycle Models Fast Acting Models

WE Series FEATURES OPTION CONFIGURATION STANDARD CONFIGURATION

Electric Actuator MULTI-TURN. ITM Series 0180 / 0450 / 0750 / 1800 / 3000

ELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Explosion proof rotary actuator - On/Off or programmable regulating actuator

FC Series Signal Conditioners

LA-5000 SERIES LINEAR VALVE ACTUATORS

VALVCON V-SERIES ACTUATOR 115VAC AND 230VAC

Overview of types. Technical data

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

ADJUSTABLE SPEED DRIVES. AS1 Drive

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

AWWA. Electric Actuators WE Series Weatherproof CSA Approved TYPE 4 & 4X ,900 in-lbs. torque C CONTROLS

FEATURES OPTIONAL FEATURES

Compact Electric Actuator. JFEW Series

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

INTEGRAL+ Integrated control

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

Invest in Confidence INTEGRAL+ Integrated control

AMRI is ISO 9001 approved. Direct 1/4 turn electric actuators ACTELEC 3, 6, 12, 25, 50, 100 and 150 Output torques up to 1500 Nm

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Series E2000P. Electrical linear actuator. Features SPECIFICATION. Valve Division Wörth am Main. A. Hock MSR- und Electronic Service GmbH

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

To be automatically connected to the nearest North American Technical Sales Office:

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

Data sheet AWD3 3-phase, bidirectional energy meter for current converter metering with integrated S0-output Controls Division

em4 local - Robust Specific characteristics Part number

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

S11 Adjustable Speed Drive Engineering Specification

Spring Return DuraDrive Proportional Actuator

BFS / BFSM SERIES Installation & Maintenance Manual

Meduim Voltage Drives

RUDOLF Digital power analyzer. Advanced Version

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Economic Style Electric Actuator. ITQ Series

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Technical data. Parameterisable damper actuator in the

Installation Instructions for the 50FY Series Hall Effect Door Interrupt System, EN954 Category III

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Supplemental Motor Protection Devices Specifications

VALVCON V Series Actuator. 115VAC and 230VAC

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Rotary gear motor series AG8...

DISCONNECT SWITCHES. UL Listed CSA Certified

1-phase AC current voltages/frequencies Volt Volt

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

Rota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications

EN 50178, IEC

MODEL: MRP6. Final Control Elements

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Functional data Factory settings Variable Settings

Supplemental Motor Protection Devices Specifications

Operating Instruction

em4 em4 alert em4 alert 2G

CONTENTS XV300K GB r doc XV300K 2/13

COMPACT-LINE. Transmitter for ph-value

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in.

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Power consumption In operation At rest For wire sizing

Non-Spring Return DuraDrive Modulating Actuator

Power consumption In operation At rest For wire sizing

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Power consumption In operation At rest For wire sizing

2-channel speed sensor GEL 247 Compact sensor for harsh applications

DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications

PHOENIX CONTACT - 09/2009

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

Worcester Controls PB SMART PRODUCTS

Transcription:

Simple Sturdy Economical LABEL by Invest in Confidence ET Weatherproof Multi-turn Actuators ET RANGE

2 Industrial actuation made easy BERNARD CONTROLS, inventor of the industrial compact quarter turn actuator, brings to its customers valve actuation solutions supported by decades of experience. Through discussions with users over the years, BERNARD CONTROLS has identified a demand for electric actuators that are both simple and sturdy. This demand is fulfilled with BERNARD CONTROLS FIRST BC labelled products. These actuators are well designed to work under moderate environmental & operational conditions. These ranges have been developed without compromising on quality, applying the unique expertise and feedback that are the cornerstones of BERNARD CONTROLS reputation. Thus, the FIRST BC label is the guarantee of actuator solutions with a total cost of ownership (TCO) among the lowest in their category, thanks to easy commissioning, proven reliability and a maintenance-free design. The quarter-turn EZ range was the first product range to meet all criteria set by the FIRST BC label. With the ET range, BC now offers a multi-turn actuator solution to its customers within the FIRST BC label criteria. 2015 - What s new? ET RANGE > New weatherproof multi-turn actuators Contents ET range overview > 3 Tech Data - Performances > 8 Main features > 4 Tech Data - Dimensions > 10 Product specifications 6 Tech Data - Product selection > 11 >

3 ET range overview Weatherproof Multi-turn Actuators SIMPLE, STURDY, ECONOMICAL Adaptation to all multi-turn valves: torque range from 30 to 200 Nm IP 67 Type of operation: Class A: On/Off Class B: Positioning Type of controls: Switches - ET SWITCH for On-Off applications Integrated control - ET LOGIC for On-Off or Positioning applications Compact industrial design & Maintenance-free ET SWITCH ET LOGIC LABEL

4 Main features FIRST BC features FIRST BC labelled actuators are technically and economically optimized for their applications: > Moderate environmental constraints (IP67 and ambiant temperatures) > Moderate operational constraints (limited operating service) ET actuators are: > Easy to install thanks to compactness, non intrusive settings for ET LOGIC models, > Easy to use with local display and signaling by LED on ET LOGIC models (integrated control), > Easy to maintain as ET are maintenance-free. in order to address perfectly customers demand for simple and sturdy actuators. ET RANGE Easy commissioning Proven reliability Maintenance-free Proven mechanical design Relying on its expertise on multi-turn actuators built-up on the ST, STX and ASM ranges, BERNARD CONTROLS has designed a compact and heavy duty multi-turn actuator with key mechanical features: > Self-locking gearing available at all speeds and lubricafication for product life-time for trouble-free operation > Adjustable torque limiter from 40 to 100% of torque value. Easy setting with screwdriver. > Reliable travel limit system: vibration-proof camblock system for ET SWITCH and hall-effect sensor for ET LOGIC > Wide range of number of turns: several ranges available from 2 to 1215 turns (please refer to ET Tech Data for details) * 1-phase motor only

5 ET SWITCH, for On-Off applications In this configuration, the control unit is designed by the customer and located in a remote cabinet. All information sent by the actuator sensors (travel limit, torque limit, thermal overload,...) have to be processed by user s control logic. Power reversing starters are also housed in the remote cabinet. As far as travel limitation adjustment is concerned, BERNARD CONTROLS original patented camblock system allows to quickly set the cams positions with a standard flat head screwdriver. Each single cam can be set independently from the others. The cams are automatically locked in their respective positions, once adjusted, and unaffected by vibrations. SWITCH control BC patented camblock ET LOGIC, for On-Off or Positioning applications ET actuators are available with integrated control for extended control features and improved userfriendliness: > Easy commissioning: non-intrusive simplified settings thanks to keys and menus on local display, > Improved compactness of integrated electronics. > Local commands with 4 keys and signaling on a 7-segment display, with position displayed in percentage of opening, BERNARD CONTROLS proposes ET LOGIC actuators for On-Off or Positioning applications which allow precise positioning (better than 2%) with position feedback. ET LOGIC Motor ET LOGIC Motor Local/Remote selection Local/Remote selection Power supply Power supply Open Close Analogic set-point Position feed-back Opened Closed Alarm Opened Closed Alarm Control station Control station ET LOGIC control board ET LOGIC integrated control On-Off version ET LOGIC integrated control Positioning version LABEL

6 Product specifications General specifications General Setting range: 40% to 100% of actuactor maximum torque by steps of 10% ET actuators include TENV* motor, gear case, emergency handwheel, travel limit control and torque control Wide range of number of turns: 2 to 1215 turns Gear design Gears are lubricated for product lifetime, and are mechanically self-locking in option. Design life 10,000 cycles Tested according to EN15714-2 Class A: On-Off & Class B: Positioning Enclosures Actuator housing in cast aluminum, polyuréthane paint Ral2010 complying with ISO 12944 C2 IP67 Motor technology Totally-enclosed, 3-phase or 1-phase asynchronous motor, class F insulation with integrated thermal overload protection Motor duty S4-25% motor duty rating to IEC 60034-1. 360 starts/hour in peak Temperature range -20... +60 C / -4... +140 F Electrical connection Screw-type terminals for controls and power supply. Internal earth grounding post Compliance with Directives & Standards Other certifications available Actuators comply with: EC directives 2004/108/EC, 2006/95/EC and standards EN 61000-6-4, EN 61000-6-2, EN 60034-1 and EN 60529 Customs Union (EAC) certified models for Belarus, Kazakhstan and Russia * Totally Enclosed & Not Ventilated ET SWITCH specifications Operation Commissioning Position indication Cable entries Anti-condensation Travel limit system Torque limiting system On/Off Easy setting of travel limit and torque limit systems with a simple screwdriver Mechanical position indicator 2 x M20 sealed by caps Heater Camblock with 4 SPDT switches ; 250 VAC-16 A / 48 VDC-2,5 Amax. (resistive load) Torque limit switch gives a maintained signal with self-locking option (and gives a pulse signal as standard). 2 contacts as standard; SPDT; 250VAC-16A / 48 VDC-2,5A max. (resistive load)

7 ET LOGIC specifications Operation On/Off or Positioning with resolution better than 2% Commissioning Non-intrusive settings Setting simplified by use of keys and menus on the display Cable entries 3 x M20 sealed by caps Anti-condensation Included in the power board Motor Supply Solid state relay (all voltages) Protections Fuse protection: - At transformer primary: 1 fuse (not exchangeable) - At transformer secondary: 1 exchangeable fuse for each output. Automatic phase correction (for 3-phase supply) Reversal rotation protection Alarm signaling (local and remote) Torque limiter Local command inhibition by local command Remote command (ON/OFF) Analog input command (Positioning) Analog inputs Local command Isolated by optocouplers by voltage: 10 to 250 V DC/AC by dry contacts (use ET LOGIC internal DC supply) Minimum pulse duration: 100ms Time of rotational direction change: 300ms Input signal and position signal are fully isolated Standard input signal: 4-20 ma Input signal: 0-20 ma (on request) Input signal: 0-10 V (on request) In current: impedance of 160 Ω In voltage: impedance of 4000 Ω 4 keys : Local-remote selector/ Open / Close / Stop Position signaling relays Alarm relay Local signaling Analog position signal Max. output impedance 1 latching relay* : valve opened 1 latching relay* : valve closed Switch configuration : Normally Opened Minimum current 10mA at 5V Max current: 5A at 250V AC or 5A at 30V DC max. (resistive load) *Latching relay allows keeping the position in case of power cut. SPDT switch Minimum current 10mA at 5V Max current: 5A at 250V AC or 5A at 30V DC max. (resistive load) Fault reported: Power supply or fuse alarm Loss a phase (with 3-phase supply) Motor overheating Motor jamming Local command in local mode Loss of 4-20mA input signal (if configured with positioner and 4-20mA) Signaling by LED: - Setting (yellow LED): ON in set-up mode - Alarm (red LED): ON if a fault appear - Local (green LED): ON in Local mode - Opened (configurable red or green LED): ON when Opened position reached. Flashing during operation. - Closed (configurable green or red LED): ON when Closed position reached. Flashing during operation. Menu & position: on 7-segment display External DC supply (12 to 30VDC) Output signal: 4-20mA if input signal is 4-20mA Output signal: 0-20 ma if input signal is 0-20 ma Output signal: 0-20 ma (0-10V using a 500Ω external resistor) if input signal is 0-10V Maximum acceptable impedance of 750 Ohms with 24VDC (without 500Ω resistor) LABEL

B E R N A R D C O N T R O L S G R O U P CORPORATE HEADQUARTERS 4 rue d Arsonval - CS 70091 / 95505 Gonesse CEDEX France / Tel. : +33 (0)1 34 07 71 00 / Fax : +33 (0)1 34 07 71 01 / mail@bernardcontrols.com OPERATING UNITS BELGIUM BERNARD CONTROLS BENELUX BRUSSELS inquiry.belgium@bernardcontrols.com inquiry.holland@bernardcontrols.com Tel. +32 (0)2 343 41 22 CHINA BERNARD CONTROLS CHINA BEIJING inquiry.china@bernardcontrols.com Tel. +86 (0) 10 6789 2861 FRANCE BERNARD CONTROLS FRANCE GONESSE (PARIS) inquiry.france@bernardcontrols.com Tel. +33 (0)1 34 07 71 00 GERMANY BERNARD CONTROLS DEUFRA TROISDORF inquiry.germany@bernardcontrols.com Tel. +49 2241 9834 0 ITALY BERNARD CONTROLS ITALIA MILANO inquiry.italy@bernardcontrols.com Tel. +39 02 931 85 233 KOREA BERNARD CONTROLS KOREA SEOUL inquiry.korea@bernardcontrols.com Tel. +82 2 553 6957 MIDDLE-EAST BERNARD CONTROLS MIDDLE-EAST DUBAI - U.A.E. inquiry.middleeast@bernardcontrols.com Tel. +971 4 880 0660 CHENNAI - INDIA inquiry.india@bernardcontrols.com Tel. +971 4 880 0660 RUSSIA BERNARD CONTROLS RUSSIA MOSCOW inquiry.russia@bernardcontrols.com Tel. +7 (499) 251 06 54 SINGAPORE BERNARD CONTROLS SINGAPORE SINGAPORE inquiry.singapore@bernardcontrols.com Tel. +65 65 654 227 SPAIN BERNARD CONTROLS SPAIN MADRID inquiry.spain@bernardcontrols.com Tel. +34 91 30 41 139 UNITED STATES BERNARD CONTROLS Inc HOUSTON inquiry.usa@bernardcontrols.com Tel. +1 281 578 66 66 More than 50 agents and distributors worldwide. Contact details on www.bernardcontrols.com Invest in Confidence CAT01-03_ENG_GRP_REV01 All data in this brochure are given for information only and are subject to change without notice.