Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR

Similar documents
Loop Powered Indicator

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

IP26 Series Current to Pneumatic Converter

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

CERTIFICATE OF COMPLIANCE

1-830 SERIES DISPLACEMENT TRANSMITTER

Miniature Temptran RTD Transmitters

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT TEL: FAX:

Level Lance Model 5100

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT

AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

Two-Wire Programmable Transmitter for:

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

ESSENTIAL INSTRUCTIONS Read this page before proceeding!

250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams

CEC VIBRATION TRANSMITTER

ISOLATED 4-20 ma TRANSMITTERS

MODEL: M2DYS SEN TRONIC AG

FLEX Ex Power Supplies

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

TIY Programmable, Isolated Thermocouple Transmitter combines

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

JM Enclosure Dimensions (in mm)

Liquid Level Sensors. M-Series Magnetostrictive Sensors

Alphaline Temperature Transmitters

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

All TXI7850 products are ROHS compliant.

Installation, Operation and Maintenance Manual

Universal Intelligent 2-wire DIN Rail Transmitters

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

User's Manual Model SE14 Magnetic Flow Converter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Triplett 3444A Power Supply Modification Notes

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Universal Intelligent 2-wire DIN Rail Transmitters

WATT TRANSDUCER. Instruction Manual

Humidity Sensor/Transmitter Assembly

Certificate of Compliance

Intrinsic Safety Control Drawing

SMART TEMPERATURE TRANSMITTERS. smar

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

AD-8100 & AD-8200 Servo Amplifiers

MODEL: W2TS. Mini-MW Series

Operating Principles

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

INSTALLATION & OPERATION MANUAL

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Universal Intelligent 2-wire In-head Transmitters

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

EN Series Installation Manual

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Tel: (949) Fax: (949) IAA100 Product Manual

General Specifications

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

General Specifications

Operator Manual 1.4 FRACSIM MINI

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Temperature Transmitters TMT 136, TMT 137

MODEL TI196 Current Loop Meter Installation and Operation Instructions

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Process Calibrator. TechChek 820

This Errata Sheet contains corrections or changes made after the publication of this manual.

MODEL AT-10 ANALOG TRANSMITTER

BA507C & BA508C loop-powered 3½ digit panel mounting indicators

FLEX Ex Thermocouple/RTD Input Module

Non-Submersible Industrial Pressure Transducer

Industrial Pressure Transducers

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

Liquid Level Transmitter Model MC420 Analog Output

ST6911 IPT ACCELERATION VIBRATION TRANSDUCER ST6917 IPT VELOCITY VIBRATION TRANSDUCER Installation Manual

Kotron Model 82 CE RF Level Transmitter

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

Transcription:

DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT 06605 203-368-6751 FAX 203-368-3747 http://www.devarinc.com e-mail: info@devarinc.com Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR R Manual No. 990649

INSTRUCTION MANUAL LD-LPIX LOOP POWERED INDICATOR General Description The LD-LPIX is a two-wire digital indicator that provides local process indication on a 3-1/2 digit liquid crystal display. The Indicator features 3-1/2, easy to read, 1 inch high active digits and a dummy zero. It is is powered directly from the 4 to 20 ma input loop, dropping less than 1 volt across the input terminals. The LD-LPIX provides a digital readout directly proportional to the current input. The indicator is calibrated at the factory to read 0 to 100.0% for a 4 to 20 ma input, however, it can easily be recalibrated in the field to read directly in engineering units, such as temperature or flow. Each indicator comes with a selection of stick-on labels of commonly used engineering units such as GPM, PSI, etc.. These labels can be attached to the display so that a user can immediately determine what the indicator is reading. Recalibration of the LD-LPIX is easily accomplished through the use of switches and trim pots. The span can be adjusted from 0 to 3998 counts in three switch selectable ranges and the zero offset can be adjusted from - 1999 to 1999 counts also in three switch selectable ranges. Fine adjustment of span and zero is made on two noninteractive 15 turn trim pots. Another feature of the LD-LPIX is a nonactive (dummy) zero, which can be enabled or disabled by means of a DIP switch. One of four decimal point positions or no decimal point is also DIP switch selectable. The LD-LPIX provides negative polarity indication, which appears when displaying quantities such as - 300 to 1000 o F. The negative sign can, if desired, be disabled by means of a DIP switch. An additional feature of the LD-LPIX is the internal calibrator. The indicator can be field calibrated while installed in a working 4 to 20 ma loop, regardless of the current through the loop, simply by switching into the calibrate mode. The indicator can also be calibrated on the bench by using a conventional calibrator or by connecting a 1 to 1.5 volt power source (flashlight battery) across the input terminals and switching to the calibrate mode. The LD-LPIX is housed in an Explosion-Proof NEMA 3, 4, 7 and 9 Epoxy painted housing. Rated Class I Groups C & D; Class II Groups E, F & G. Options are a bracket for 2 inch pipe mounting (Option M36G) and Black Lit Display (-BL -LD). Specifications 1. Input a. Range: 4 to 20 ma b. Voltage drop: 0.98V @ 20mA, 25 o C c. Forward current over range: 100 ma max. d. Reverse current: 100 ma max. 2. Display a. Type: 3-1/2 digit LCD, with dummy zero, 1" high digits b. Range: -1999 to 1999 counts c. Decimal point: four positions or absent, switch selectable d. Polarity sign: negative polarity indication or none, switch selectable e. Action: forward acting (count increases with cur rent), normal calibration; reverse acting (count decreases with current), obtained by appropriate zero setting f. Over range indication: display blanks except for most significant 1 3. Calibration a. Span range: 0 to 3998 counts, 3 ranges switch selectable, fine adjustment on 15 turn trim pot, noninteractive with zero pot b. Offset range: -1999 to 1999 counts, 3 ranges switch selectable, fine adjustment on 15 turn trim pot, noninteractive with span pot c. Resolution: better than 1 count 4. Performance a. Accuracy: ± 0.1% of span counts, ± 1 count b. Temperature effect (zero): ± 0.1 count / o C c. Temperature effect (span): ±.01% of span counts per o C d. Operating temperature: -30 to 85 o C e. Ripple rejection: less than 1 count with 1 ma peak-to-peak, 60 Hz ripple at input f. Sample rate: 2 per second DEVAR Inc. 706 Bostwick Ave., Bridgeport CT 06605-2396 Tel: (203) 368 6751 Fax: (203) 368 3747 www.devarinc.com E-Mail: info@devarinc.com

Field Wiring Field connections are made to a compression type terminal block located at the bottom of the enclosure. To expose the terminal block remove the cover from the enclosure, loosen the two screws at the corners of the PC board and remove the PC board from the enclosure. Terminals 1 and 2 are the positive and negative input terminals, terminal 3 is a spare which can be used as a tie point. The field wiring terminal block is connected to a two point terminal block located on the top left hand corner of the PC board. When bench testing the unit, input signals can be connected directly to the top terminal block without removing the PC board from the enclosure. Initial Settings 1. Set Input Voltage Drop (Factory Calibrated) : input 20 milliamps at the input terminals of the indicator. Adjust pot "P1" for a voltage drop of 0.95 volts between the input terminals. 2. Zero Adjustment (Factory Calibrated): To prevent the interaction of the span and zero pots the 4 milliamp off set is compensated for at the output of amplifier "U1". To do this, input 4 milliamps into the indicator, set switch 2. position 2 to the normal operating position, and then adjust pot "P2" for 0.000 volts between pins 3 and 6 of amplifier "U1". 3. Calibration of Internal Calibrator (Factory Calibrated): Calibrate the display to read 00.0 to 100.0 for a 4 to 20 milliamp input following the instructions for calibrating the display. With the indicator operating (the value of the input current does not matter) switch switch 2, position 2. to the Activate Internal Calibrator position. Switch switch 2, position 1 to the Calibrate Zero position and adjust pot "P3", until the display reads 00.0. Switch switch 2, position 1 to the Calibrate Span position and adjust pot "P4" until the display reads 100.0. Return switch 2, position 2 to the Normal Operating position. Note that the input current has no effect on the display while switch 2 is in the Activate Internal Calibrator posi tion. Display Calibration To calibrate the LD-LPI, proceed as follows: 1. Determine desired display for a 4 to 20 ma input. Example: -30.0 to 195.0 o F 2. Set span switches S1-1 and S1-2 for the proper span range. Example: Span = 1950 - (-300) = 2250 counts; set S1-1 off, S1-2 off; (Note: ignore decimal point) 3. Set zero switches S1-3 and S1-4 for proper zero range. Example: Zero = -300 counts; set S1-3 off, S1-4 off 4. Select decimal point. Example: Select P3 decimal point; set S1-7 on, S1-5,6,8 off 5. Enable or disable negative polarity indication. Example: Enable negative sign; set S1-10 on 6. Enable or disable dummy zero. Example: Disable dummy zero; set S1-9 off 7. Input 4 ma and set "zero pot" for bottom of range. Example: Adjust zero pot to display -30.0 8. Input 20 ma and set "span pot" for top of range. Example: Adjust span pot to display 195.0 9. The indicator is now calibrated. Note that the dummy zero is not an active digit and should not be used when determining span and zero counts. Using The Internal Calibrator The LD-LPI can be calibrated using the internal calibrator, while installed in a working loop, or it can be calibrated on the bench by connecting a 1 to 1.5 volt supply across the input terminals as a power source. To use the internal calibrator proceed as follows: 1. Set the calibrating switches for the desired span and offset ranges as described in the preceding section. 2. Set switch 2, position 2 to the Activate Internal Calibrator position. 3. Set switch 2, position 1 to the Calibrate Zero position, then adjust the "zero pot" until the bot tom of the range is displayed. 4. Set switch 2, position 1 to the Calibrate Span position, then adjust the "span pot" until the the top of the range is displayed. 5. Return switch 2, position 2 to the Normal Operation position. The indicator is now cali brated.

MOUNTING SCREW 2-2 2-1 P2 P3 P4 P1 INPUT (RED) -INPUT (BLACK) TO FIELD WIRING TERMINAL BLOCK AT BOTTOM OF ENCLOSURE 1 2 3 4 5 6 7 8 9 10 ZERO POT SWITCHES 1-1 TO 1-10 ON MOUNTING SCREW DUMMY ZERO SPAN POT NORM. OPERATION CALIBRATE ZERO ACTIVATE INTERNAL CALIBRATOR CALIBRATE SPAN DEPRESS TO ACTIVATE SWITCH 2 Fig. 1 PC Board Layout S1-1 S1-2 SPAN RANGE OFF ON 000 TO 1530 COUNTS OFF OFF 1530 TO 2470 COUNTS ON OFF 2470 TO 3998 COUNTS S1-3 S1-4 ZERO OFFSET ON OFF -573 TO -1999 COUNTS OFF OFF -573 TO 573 COUNTS OFF ON 573 TO 1999 COUNTS S1-5 ON 1. 9 9 9_ S1-6 ON 1 9. 9 9_ SELECT DECIMAL S1-7 ON 1 9 9. 9_ POINT S1-8 ON 1 9 9 9._ S1-9 ON 1 9 9 9 0 ENABLE DUMMY ZERO S1-10 ON ENABLES NEGATIVE POLARITY INDICATION Fig. 2 Switch Setting Table

OPTION -LPS ADD INTERNAL LOOP POWER SUPPLY TO LD-LPI LOOP POWERED INDICATOR The Model LD-LPI-LPS provides a regulated 24 volt DC power supply, which can be used to power an external 2-wire transmitter in a 4 to 20 ma instrumentation loop. The power supply features a split bobbin power transformer and output current limiting circuitry. The 24 volt power supply is normally connected in series with the field transmitter, the loop powered indicator and any other loads in the 4 to 20 ma loop. A two position terminal block is provided for AC power and a six position terminal block is provided for connections between the transmitter, the indicator and the power supply. Specifications: Power............... 105 to 125 V, 50/60 Hz,5 VA 210 to 250 V, 50/60 Hz, 5 VA (Option E-71) Output Voltage......... 24 VDC ±1 V Output Current......... 25 ma, Internally Limited Line Regulation........ 0.004% per Volt Typ., 0.06% per Volt Max. Load Regulation....... 0.004% Typ., 0.04% Max. Ripple............... 20 mv P-P, Max. Temperature Range.... Temperature Effect..... -40 to 85 O C 0.008% per O C, Typ.

LD-LPI-LPS 115 VAC LD-LPI DISPLAY - RED BLU POWER SUPPLY - TB2 1 2 3 4 5 6 TB1 4/20 ma - 24 VDC - INPUT SIGNAL POWER SOURCE Fig. 1 Internal Wiring of LD-LPI-LPS - - LOAD 1 2 3 4 5 6 - X T - - X T 1 2 3 4 5 6 - LOAD Fig. 2 Typical Wiring For 2-Wire Field Transmitter OPTION -BL ADD BACK LIGHTING TO THE LD-LPI Option BL adds back lighting to the LD-LPI display. This option allows the meter to be easily viewed in low light conditions as well as in normal light conditions. The back lighting derives its power from the 4 to 20 ma loop and adds a 2 volt burden to the loop. The total input voltage drop for the LD-LPI-BL is 3 volts at 20 ma.

FM APPROVED DWG NO. 515107 H ADD 18-SLPI, 18-SLPI-IV AND 18-SLPI-SR, ECN 3081A 02-08-95 I ADD LD-LPI, ECN 3154 01-22-98 J ADD SM-822P-1, SM-822P-1T, SM-822P-2 & SM-822R, ECN 3208 09-09-99 K ADD LD-LPIX & -BL BACKLIGHT OPTION, ECN 3319 09-13-05 HAZARDOUS LOCATION INDICATORS RTD T.C. TRANSMITTERS INTRINSICALLY SAFE ENTITY APPROVED DEVAR MODEL NOS. 18-811 18-812 18-212A 18-215A SM-822 P-1 SM-822 P-1T SM-822 P-2 SM-822 R INTRINSICALLY SAFE ENTITY APPROVED DEVAR MODEL NOS. 18-LPI 18-LPI-WT 18-LPI-SR 18-LPIX 18-LPIX-SR 18-LPI-1V 18-LPIX-1V 18-SLPI 18-SLPI-1V 18-SLPI-SR LD-LPI LD-LPIX -BL BACKLIGHT OPTION POTENIOMETER RHEOSTAT NOTES: 1. HAZARDOUS LOCATION RATINGS: CLASS I, DIVISION 1, GROUPS A, B, C, D 2. ENTITY PARAMETERS: Vmax = 32 V, Imax = 150 ma, Ci = 0 µf, Li = 0 mh 3. INSTALLATION OF THE SYSTEM MUST BE IN ACCORDANCE WITH ANSI/ISA RP12.6 4. CONTROL ROOM INSTRUMENTATION TO OPERATE AT LESS THAN 250V rms 5. DO NOT CONNECT ma METER TO TRANSMITTER MONITOR TERMINALS UNLESS AREA IS KNOWN TO BE SAFE 6. THE ABOVE UNITS ARE NONINCENDIVE FOR CLASS I, DIVISION 2, GROUPS A, B, C, D LOCATIONS WITH A Vmax OF 32V. BARRIERS ARE NOT REQUIRED FOR DIVISION 2 OPERATION. 7. NO REVISIONS WITHOUT PRIOR FACTORY MUTUAL APPROVAL This Drawing is the sole property of DEVAR Inc., and is submitted on the understanding that the contents hereof are not published and are not to be disclosed. to third persons without prior permission. UNSPECIFIED DIMENSION TOLERANCE DECIMAL /- 0.005" FRACTION /- 1/64" ANGLE /- 1/2 DEGREE MATERIAL FINISH NEXT ASS'Y NO. -N/A- -N/A- NONE CONTRACT NO. PREPARED CHECKED MECH ELEC DESIGN APPROVED APPROVED SH 1 REV DESCRIPTION DATE APPROVED E RELEASE ECN 2826B 04-22-91 F ADD 18-LPI-WT, ECN 3027 02-26-92 G 32V WAS 30V, ECN 3081 02-07-95 NON-HAZARDOUS LOCATION DUAL CHANNEL BARRIER 32V MAX L O A D 0V Vmax > Vt Imax > It Ci plus interconnecting wiring < Ca Li plus interconnecting wiring < La OR SINGLE CHANNEL BARRIER LOAD 32V MAX 0V Vmax > Voc Imax > Isc Ci plus interconnecting wiring < Ca Li plus interconnecting wiring < La RNT 08-16-05 DEVAR Inc. 706 Bostwick Avenue, Bridgeport, Conn. 06605 TEL: (203) 368-6751 FAX; (203) 368-3747 INTERCONNECTING DIRAM TO INTRINSICALLY SAFE APPARATUS SIZE B SCALE DRAWING NO. NONE WT SHEET 1 OF 1 REV 515107 K

DWG NO. 515380 D ADD LD-LPI; ECN 3119 06-14-96 SH 1 REV DESCRIPTION DATE APPROVED A B C PROPOSED 08-21-91 RELEASE ECN 3031A 03-20-92 ADD 18-SLPI-IV; ECN 3081A 02-13-95 HAZARDOUS LOCATION NON-HAZARDOUS LOCATION SINGLE CHANNEL BARRIER WITH DIODE RETURN RTD T.C. TRANSMITTERS INTRINSICALLY SAFE DEVAR MODEL NOS. 18-812 RTD/RESISTANCE 18-215A THERMOCOUPLE INDICATORS INTRINSICALLY SAFE DEVAR MODEL NOS. 18-LPI-1V 18-SLPI-1V LD-LPI BARRIER GROUND L O A D 28V MAX USE ANY CSA CERTIFIED SINGLE CHANNEL ZENER DIODE BARRIER HAVING PARAMETERS OF 28 VOLTS(max) / 300 OHMS(min) AND A CSA CERTIFIED DIODE RETURN BARRIER. 0V NOTES: 1. HAZARDOUS LOCATION RATINGS: CLASS I, DIVISION 1, GROUPS C, D. 2. INSTALLATION OF THE SYSTEM MUST BE IN ACCORDANCE WITH C.E.C. PART I. 3. CONTROL ROOM INSTRUMENTATION TO OPERATE AT LESS THAN 250V. 4. DO NOT CONNECT ma METER TO TRANSMITTER MONITOR TERMINALS UNLESS AREA IS KNOWN TO BE SAFE. 5. THE ABOVE UNITS ARE CSA CERTIFIED FOR CLASS I, DIVISION 2, GROUPS A, B, C, D LOCATIONS WITH A Vmax OF 30V. BARRIERS ARE NOT REQUIRED FOR DIVISION 2 OPERATION. THE TRANSMITTERS PROVIDE NON-INCENDIVE CIRCUITS TO RTD'S AND THERMOCOUPLES. 6. THE INDICATOR MAY OR MAY NOT BE IN THE LOOP. 7. THE TRANSMITTERS MUST BE INSTALLED IN (AND BONDED TO) A SUITABLE ENCLOSURE WHICH IS CONNECTED TO THE I.S. BARRIER GROUND. 8. WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. AVERTISSEMENT: LA SUBSTITUTION DE COMPOSANTS PEUT COMPROMETTRE LA SECURITE INTRINSEQUE. 9. NO REVISIONS WITHOUT PRIOR CANADIAN STANDARDS ASSOCIATION APPROVAL. BARRIER GROUND OR SINGLE CHANNEL BARRIER LOAD 28V MAX USE ANY CSA CERTIFIED SINGLE CHANNEL ZENER DIODE BARRIER HAVING PARAMETERS OF 28 VOLTS (max) / 300 OHMS (min). 0V This Drawing is the sole property of DEVAR Inc., and is submitted on the understanding that the contents hereof are not published and are not to be disclosed. to third persons without prior permission. UNSPECIFIED DIMENSION TOLERANCE DECIMAL /- 0.005" FRACTION /- 1/64" ANGLE /- 1/2 DEGREE MATERIAL FINISH NEXT ASS'Y NO. -N/A- -N/A- NONE CONTRACT NO. PREPARED CHECKED MECH ELEC DESIGN APPROVED APPROVED 4-9-92 LH 08-21-91 DEVAR Inc. SIZE B SCALE INTERCONNECTING DIRAM TO INTRINSICALLY SAFE APPARATUS DRAWING NO. NONE 515380 WT 706 Bostwick Avenue, Bridgeport, Conn. 06605 TEL: (203) 368-6751 FAX; (203) 368-3747 SHEET 1 OF 1 REV D R