Description of Version

Similar documents
TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

EMC TEST REPORT. According to

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

EMC Test report for LED Panel Light Models , , , , ,

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

For the following Product : LED CONVERTER Model Name : OLW250P701N1A

For the following Product : LED CONVERTER Model Name : OLW160P351N1A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC Test Report. Report Number: M030826

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

TEST REPORT... 1 CONTENT...

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

Test Report GUANGDONG EAST POWER CO., LTD

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

The standards relevant for the evaluation of EMC requirements are as follows:

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC test report AU01+E04

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

PT. SARANA KARYA SOLUSINDO.

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

1 SUMMARY OF STANDARDS AND RESULTS

EMC TEST REPORT For CE

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

Declaration of Conformity.

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

2620 Modular Measurement and Control System

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Test Report GUANGDONG EAST POWER CO., LTD

The standards relevant for the evaluation of EMC requirements are as follows:

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server

The standards relevant for the evaluation of EMC requirements are as follows:

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

Revision History of Report

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

FCC Verification TEST REPORT

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U

EMC TEST REPORT For LOKOLED LED Downlight Model No.: LL-17-45W-Floodlight-R-VL, LL-06-45W-18K/M

CE TEST CERTIFICATION

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Transcription:

Description of Version Edition No. Data of Revision Revision Summary Report No. 0 February 07, 2017 Original Report BWS-17-EC-0015 This Test Report shall not be reproduced, except in full, without the written approval of the BWS TECH Inc. This document may. Be altered or revised by BWS TECH Inc. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by BWS TECH Inc. will constitute fraud and shall nullify the document. Page Number : Page 2 of 51

TABLE OF CONTENTS Description of Version 3 1. General Description of EUT 4-5 2. General Information of Test 6-8 3.1 Conducted Emission Tests 9-17 3.2 Radiated Emission Tests 18-21 3.3 Radiated Electromagnetic disturbance Test 22-29 3.4 Power Frequency Harmonics and Flicker Emission Tests 30-35 3.5 Electrostatic Discharge Immunity Test 36-38 3.6 Radiated, radio-frequency, electromagnetic field immunity test 39-40 3.7 Electrical fast transient/burst immunity test 41-42 3.8 Surge immunity test 43-44 3.9 Conducted immunity test 45-46 3.10 Voltage Dips and Short interruptions immunity test 47-48 4. EUT Photographs 49-51 Page Number : Page 3 of 51

1. General Description of EUT 1.1 Applicant Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16674 Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : +82-31-8006-7677 FAX : - 1.2 Manufacturer Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16674 Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : +82-31-8006-7677 FAX : - 1.3 Factory Factory 1 : Dongguan Solum Electronics Co., Ltd. Address : Hengkeng Management Area, Liaobu Town, Dongguan City, Guangdong Province 523413, People s Republic of China Factory 2 : Dongguan Aptech Electronics Co., Ltd. Address : Jinfu 2 Road, TangChun East Area, TangChun Village, LiaoBu Town 523407 DongGuan City, GuangDong Province, People's Republic of China Factory 3 : Dongguan Yingju Power Co., Ltd. Address : No.6 Yongxing Road, Shayao Village, Shijie Town, Dongguan City, Guangdong Province, 523292, People s Republic of China Factory 4 : SOLUM VINA COMPANY LIMITED Address : Plot B3, Bathien 2 Industrial Park, Thien Ke Ward, Binh Xuyen District, Vinh Phuc Province, 281200, Vietnam Page Number : Page 4 of 51

1.4 Basic Description of EUT Trade Name : Product Name : LED CONVERTER Model Name : OLU201P701U1A ADD Model : OLU201P701U1U, OLU201P701N1A, OLU201P701N1U Serial Number : Prototype Test Voltage : AC 230 V, 50 Hz Rating : PRI Input: AC (120 277) V, 50/60 Hz, 2.0 A, 210 W SEC Output: DC (160 250) V, 0.7 A, 185 W Page Number : Page 5 of 51

2. General Information of Test 2.1 Test Facility This test was carried out by BWS TECH Inc. Test Site Location : 23, Gokhyeon-ro 480 Beon-gil, Mohyeon-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do 449-853, Korea TEL : 82-31-333-5997 FAX : 82-31-333-0017 2.2 Standard for Methods of Measurement Basic Standard Description Test Result EN 55015:2013 EN 61547:2009 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general lighting purposes EMC immunity requirements Pass Pass Fail Fail EN 61000-3-2:2014 Mains harmonics equipment up to 16A. Pass Fail EN 61000-3-3:2013 Voltage fluctuations equipment up to 16A. Pass Fail EN 61000-4-2:2009 EN 61000-4-3:2006+A2:2010 EN 61000-4-4:2012 Testing and measurement techniques. Electrostatic discharge immunity test. Testing and measurement techniques. Radiated Immunity. Testing and measurement techniques. Electrical fast transient/burst immunity test. EN 61000-4-5:2014 Testing and measurement techniques. Surge immunity test. Pass Fail EN 61000-4-6:2014 Testing and measurement techniques. Immunity to conducted disturbances induced by Pass Fail radio frequency fields. EN 61000-4-8:2010 Testing and measurement techniques. Power frequency magnetic field Immunity Test. N/A #Note 1 EN 61000-4-11:2004 Testing and measurement techniques. Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests. Pass Fail #Note 1. This test was excluded, because EUT was not containing any devices susceptible to magnetic fields. 2.3 Description of EUT Modification - N/A Pass Pass Pass Fail Fail Fail Page Number : Page 6 of 51

2.4 Model Difference Classification Model Name Difference 1 Basic model OLU201P701U1A Dimming 2 OLU201P701U1U Dimming 3 Series models OLU201P701N1A Non Dimming (UL Model) 4 OLU201P701N1U Non Dimming (UL Model) Difference between basic model and series model - Identical to the basic model except for dimmer cable. 2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be reproduced in full. Partial reproduction may only be made with the written permission of the BWS Tech Inc. 2.6 Test Conditions EUT Operating Mode EUT was tested according to the following operation modes provided by the specifications given by the manufacturer, and reported the worst emissions. Operation Modes Worst Case Mode Normal Operation Mode Performance Criteria A) Performance Criterion A During the test, no change of the luminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended. B) Performance Criterion B During the test, the luminous intensity may change to any value. After the test, the luminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given. C) Performance Criterion C During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control Page Number : Page 7 of 51

Test System layout on EUT and peripherals Interface cable Power cable EUT DIM Lever LED Jig 2.7 Description of Test System (EMI and EMS) Type of Peripheral Equipment Used: Description Model Name Serial No. Manufacturer EUT OLU201P701U1A Prototype SoluM Co., Ltd. LED Jig N/A N/A N/A DIM Lever NTSTV-DV N/A N/A Type of Cables Used: Device from I/O Port Device to I/O Port Length(m) Type of Shield AC IN AC Power Socket AC OUT 1.2 Unshielded EUT DC OUT LED Jig DC IN 0.3 Unshielded DIM DIM Lever DIM 0.8 Unshielded Page Number : Page 8 of 51

3.1 Conducted Emission Tests Conducted Emissions were measured from 9 khz to 150 khz with a bandwidth of 200 Hz, 150 khz to 30 MHz with a bandwidth of 9 khz on the 230 V AC power and return leads of the EUT according to the methods defined in European Standard EN 55015:2013 Clause 8. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 3.1.5. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions. 3.1.1 Test Condition 3.1.2 Test Standard Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : February 06, 2017 Temperature/Humidity : 18 C / 38 % R.H. Item Main Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak 0.009-0.05 110-0.05-0.15 90 to 80-0.15-0.5 66 to 56 56 to 46 0.5-5.0 56 46 5.0-30 60 50 Item Control Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak 0.15-0.5 84 to 74 74 to 64 0.5-30 74 64 3.1.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use EMI Test Receiver ESR ROHDE & SCHWARZ 101450 03. 25. 2017 LISN LN2-16N EMCIS LN16005 03. 24. 2017 HIGH VOLTAGE PROBE TK9420 SCHWARZBECK 9420-587 05. 15. 2017 Page Number : Page 9 of 51

3.1.4 Test Result of Conducted Emission EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Maximum light output level L1 Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 10 of 51

EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Maximum light output level N Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 11 of 51

EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Maximum light output level DIM Conducted Emission Test Results: PASS Test data sheets follow. Control Terminal Conducted Emission Test Data Page Number : Page 12 of 51

EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Minimum light output level L1 Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 13 of 51

EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Minimum light output level N Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 14 of 51

EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Minimum light output level DIM Conducted Emission Test Results: PASS Test data sheets follow. Control Terminal Conducted Emission Test Data Notes 1. Margin = Limit - Emission Level 2. All modes of operation were investigated and the worst-case emissions are reported. See the photos in next pages. 3. Measurement uncertainty estimated at 3.72 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. 4. The EUT was independent transformers and convertors for LED lamps. So, Insertion loss test was not applied. Page Number : Page 15 of 51

3.1.5 Photographs of Conducted Emission Test Configuration [Conducted Emission Test-Main Terminals] Page Number : Page 16 of 51

[Conducted Emission Test-Control Terminal] Page Number : Page 17 of 51

3.2 Radiated Emission Tests Radiated emissions form 30 MHz to 300 MHz were measured with a bandwidth of 120 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand in the 10 m chamber, 0.8 meter above the ground plane, as shown in section 3.2.5. The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions. 3.2.1 Test Condition Frequency Range of Test : 30 MHz to 300 MHz Test Standard : EN 55015:2013 Test Date : February 06, 2017 Temperature/Humidity : 16 C / 37 % R.H. 3.2.2 Test Standard Frequency Range (MHz) Limit (dbuv) Quasi-Peak 30 ~ 230 30 230 ~ 300 37 3.2.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Bilog Antenna VULB 9160 SCHWARZBECK 9160-3052 10. 06. 2017 EMI Test Receiver ESR ROHDE & SCHWARZ 101320 03. 25. 2017 RF AMPLFIER MPA-10-40 RF Bay 21163921 10. 10. 2017 Antenna Mast ( 4 m) AM 4.0 MATURO Positioner Controller CO2000 MATURO AM4.0/225/17 240915 NCU/459/172 40915 N/A N/A Page Number : Page 18 of 51

3.2.4 Test Result of Radiated Emission EUT : OLU201P701U1A Test distance : Maximum light output level 10 m Radiated Emission Test Results : PASS Test data sheets follow. Radiated Emission Test Data Page Number : Page 19 of 51

EUT : OLU201P701U1A Test distance : Minimum light output level 10 m Radiated Emission Test Results : PASS Test data sheets follow. Radiated Emission Test Data Notes 1. * H : Horizontal polarization, ** V : Vertical polarization 2. Margin value = Emission Level Limit (QuasiPeak) 3. Corr. = Correction factor (Antenna factor + Cable loss AMP gain) 4. Measurement uncertainty estimated at 5.49 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 20 of 51

3.2.5 Photographs of Radiated Emission Test Configuration [Radiated Emission Test] Page Number : Page 21 of 51

3.3 Radiated Electromagnetic disturbance Test Radiated emissions form 9 khz to 30 MHz were measured with a bandwidth of 200 Hz, 9 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand as shown in section 3.3.5. 3.3.1 Test Condition Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : February 06, 2017 Loop Antenna Size : 2 m Temperature/Humidity : 20 C / 31 % R.H. 3.3.2 Test Standard Frequency Range (MHz) Quasi-Peak Limit (dbuv) Average-Peak 0.009-0.07 88 N/A 0.07-0.15 88 to 58 N/A 0.15-3.0 58 to 26 N/A 3.0-30 22 N/A 3.3.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Loop Antenna HXYZ 9170 SCHWARZBECK HXYZ9170-215 N/A EMI Test Receiver ESPI ROHDE & SCHWARZ 100012 01. 06. 2018 Page Number : Page 22 of 51

3.3.4 Test Result of Radiated Emission EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Maximum light output level X-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 23 of 51

EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Maximum light output level Y-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 24 of 51

EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Maximum light output level Z-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 25 of 51

EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Minimum light output level X-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 26 of 51

EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Minimum light output level Y-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 27 of 51

EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Minimum light output level Z-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Notes 1. Margin value = Limit - Emission Level 2. All other emissions not reported were more than 25 db below the permitted limit. 3. Measurement uncertainty estimated at 2.99 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 28 of 51

3.3.5 Photographs of Radiated Electromagnetic disturbance Test. [Radiated Electromagnetic disturbance Test] Page Number : Page 29 of 51

3.4 Power Frequency Harmonics and Flicker Emission Tests 3.4.1 Test Procedure Power Frequency Harmonics Tests : The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in Clause 7 of EN 61000-3-2:2014 Flicker Emission Tests : The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of 8 % is achieved during the whole assessment procedure. 3.4.2 Test Condition EUT : OLU201P701U1A Test Standard : EN 61000-3-2:2014 EN 61000-3-3:2013 Test Date : February 06, 2017 Device Class : C Temperature/Humidity : 23 C / 35 % R.H. 3.4.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compliance Test System PACS-1 California Instruments 71980 N/A AC Power Source 5001IX California Instruments 54549 01. 05. 2018 3.4.4 Test Result of Power Frequency Harmonics and Flicker Emission Tests Power Frequency Harmonics : PASS Flicker Emission Tests : PASS Page Number : Page 30 of 51

V o l t a g e ( V o l t s ) Harmonics Class-C (Run time) EUT: OLU201P701U1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass C u r r e n t ( A m p s ) Current & voltage waveforms C u r r e n t R M S ( A m p s ) 1. 5 1. 0 0. 5 0. 0-0. 5-1. 0-1. 5 Harmonics and Class C limit line 0. 3 5 0. 3 0 0. 2 5 0. 2 0 0. 1 5 0. 1 0 0. 0 5 0. 0 0 Source qualification: Normal European Limits 300 200 100 0-1 0 0-2 0 0-3 0 0 4 8 12 16 20 24 28 32 36 40 H a r m o n i c # Test result: Pass Worst harmonics H11-58.27% of 100% limit, H11-39.16% of 150% limit. Page Number : Page 31 of 51

Current Test Result Summary (Run time) EUT: OLU201P701U1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal THC(A): 0.05 I-THD(%): 5.79 POHC(A): 0.000 POHC Limit(A): 0.075 Highest parameter values during test: V_RMS (Volts): 229.68 Frequency(Hz): 50.00 I_Peak (Amps): 1.173 I_RMS (Amps): 0.798 I_Fund (Amps): 0.790 Crest Factor: 1.480 Power (Watts): 179.0 Power Factor: 0.977 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 0.016 0.0 0.000 0.024 0.00 Pass 3 0.017 0.232 7.3 0.017 0.348 4.92 Pass 4 0.000 5 0.024 0.079 30.8 0.025 0.119 20.73 Pass 6 0.000 7 0.026 0.055 46.4 0.026 0.083 30.98 Pass 8 0.000 9 0.014 0.040 36.0 0.014 0.059 24.16 Pass 10 0.000 11 0.014 0.024 58.3 0.014 0.036 39.16 Pass 12 0.000 13 0.008 0.024 32.7 0.008 0.036 22.19 Pass 14 0.000 15 0.008 0.024 33.7 0.008 0.036 22.75 Pass 16 0.000 17 0.003 0.024 0.0 0.003 0.036 0.00 Pass 18 0.000 19 0.004 0.024 0.0 0.004 0.036 0.00 Pass 20 0.000 21 0.001 0.024 0.0 0.001 0.035 0.00 Pass 22 0.000 23 0.002 0.024 0.0 0.002 0.035 0.00 Pass 24 0.000 25 0.001 0.024 0.0 0.001 0.036 0.00 Pass 26 0.000 27 0.001 0.024 0.0 0.001 0.035 0.00 Pass 28 0.000 29 0.001 0.024 0.0 0.001 0.036 0.00 Pass 30 0.000 31 0.000 0.024 0.0 0.001 0.035 0.00 Pass 32 0.000 33 0.001 0.024 0.0 0.001 0.035 0.00 Pass 34 0.000 35 0.000 0.024 0.0 0.000 0.035 0.00 Pass 36 0.000 37 0.001 0.024 0.0 0.001 0.035 0.00 Pass 38 0.000 39 0.000 0.024 0.0 0.000 0.035 0.00 Pass 40 0.000 Note: Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. Page Number : Page 32 of 51

Voltage Source Verification Data (Run time) EUT: OLU201P701U1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal Highest parameter values during test: Voltage (Vrms): 229.68 Frequency(Hz): 50.00 I_Peak (Amps): 1.173 I_RMS (Amps): 0.798 I_Fund (Amps): 0.790 Crest Factor: 1.480 Power (Watts): 179.0 Power Factor: 0.977 Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 0.101 0.459 21.95 OK 3 0.510 2.067 24.69 OK 4 0.016 0.459 3.45 OK 5 0.045 0.919 4.90 OK 6 0.020 0.459 4.25 OK 7 0.032 0.689 4.59 OK 8 0.016 0.459 3.47 OK 9 0.031 0.459 6.76 OK 10 0.013 0.459 2.86 OK 11 0.018 0.230 7.92 OK 12 0.021 0.230 9.03 OK 13 0.015 0.230 6.52 OK 14 0.009 0.230 3.79 OK 15 0.009 0.230 4.06 OK 16 0.011 0.230 4.79 OK 17 0.013 0.230 5.76 OK 18 0.013 0.230 5.49 OK 19 0.012 0.230 5.29 OK 20 0.015 0.230 6.53 OK 21 0.008 0.230 3.43 OK 22 0.007 0.230 3.10 OK 23 0.006 0.230 2.78 OK 24 0.006 0.230 2.60 OK 25 0.009 0.230 3.86 OK 26 0.008 0.230 3.27 OK 27 0.007 0.230 2.94 OK 28 0.005 0.230 2.35 OK 29 0.004 0.230 1.68 OK 30 0.006 0.230 2.61 OK 31 0.005 0.230 2.05 OK 32 0.005 0.230 2.13 OK 33 0.005 0.230 2.27 OK 34 0.002 0.230 0.84 OK 35 0.004 0.230 1.68 OK 36 0.003 0.230 1.33 OK 37 0.003 0.230 1.35 OK 38 0.003 0.230 1.14 OK 39 0.004 0.230 1.65 OK 40 0.009 0.230 3.98 OK Page Number : Page 33 of 51

1 0 : 4 9 : 2 3 1 0 : 4 9 : 2 3 Flicker (Run time) EUT: OLU201P701U1A Tested by: ks.yoon Test category: All parameters (European limits) Test Margin: 100 Test duration (min): 10 Customer: SoluM Co., Ltd. Test Result: Pass Psti and limit line Status: Test Completed European Limits P s t 1. 0 0 0. 7 5 0. 5 0 0. 2 5 Plt and limit line P l t 0. 5 0 0. 2 5 0. 0 0 Parameter values recorded during the test: Vrms at the end of test (Volt): 229.61 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.028 Test limit: 0.650 Pass Page Number : Page 34 of 51

3.4.5 Photographs of Power Frequency Harmonics and Flicker Emission Tests Configuration. [Power Frequency Harmonics and Flicker Emission Tests- Harmonics] [Power Frequency Harmonics and Flicker Emission Tests- Flicker] Page Number : Page 35 of 51

3.5 Electrostatic Discharge Immunity Test In order to minimize the impact of environmental parameters on test results, the tests shall be carried out in climatic and electromagnetic reference conditions as specified in EN 61547:2009. The test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. The testing shall be performed by direct and indirect application of discharges to the EUT according to a test plan. 3.5.1 Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-2:2009 Test Date : February 06, 2017 Test Voltage : Contact 4 kv, Air (2,4,8) kv Performance criterion : B Temperature/Humidity/Pressure : 24 C / 36 % R.H. / 100.8 kpa 3.5.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use ESD Simulator EDS30V 3CTEST ES0121601 04. 01. 2017 3.5.3 Test Result of Electrostatic Discharge Immunity Test Electrostatic Discharge Immunity Test : PASS The equipment meets the requirements. Page Number : Page 36 of 51

Test data sheet follows. Test Point Discharge Type CD=Contact AD=Air Test Voltage(kV) Tested No Observation Result VCP CD 4 kv Each 10 times Normal PASS (A) HCP CD 4 kv Each 10 times Normal PASS (A) EUT Metal Case CD 4 kv Each 10 times Normal PASS (A) EUT Screw CD 4 kv Each 10 times Normal PASS (A) EUT Rubber AD (2,4,8) kv Each 10 times Normal PASS (A) [Test Point] AD CD Front Top Side Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Page Number : Page 37 of 51

3.5.4 Photographs of Electrostatic Discharge Immunity Test Configuration [Electrostatic Discharge Immunity Test] Page Number : Page 38 of 51

3.6 Radiated, radio-frequency, electromagnetic field immunity test Tests were conducted in accordance with EN 61547:2009 over the frequency range of 80 MHz to 1 000 MHz. The transmitting antenna was located 3 meters from the EUT at a height of 1 meter above the floor. Front, sides and back of the EUT were exposed to a uniform field of 3 V/m using both horizontal and vertical antenna polarizations. 3.6.1 Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-3:2006+A2:2010 Test Date : February 06, 2017 Test field strength (V/m) : 3 V/m Performance criterion : A Temperature/Humidity/Pressure : 23 C / 34 % R.H. / 100.8 kpa 3.6.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Signal Generator SME06 ROHDE & SCHWARZ 838529/090 06. 08. 2017 RF Power Amplifier ITA0300KL-500 Infinitech N/A 06. 22. 2017 RF Power Amplifier ITA0750KL-500 Infinitech N/A 06. 22. 2017 Log periodic Antenna K9128 Airlinklab 2016-001 N/A 3.6.3 Test Result of Radiated, radio-frequency, electromagnetic field immunity test Electromagnetic field immunity test : PASS The equipment meets the requirements. Page Number : Page 39 of 51

Test data sheet follows. Frequency Range (MHz) Position (Angle) Antenna Polarity Field Strength (V/m) Modulation Result 80-1 000 Front Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Rear Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Right Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Left Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Front Horizontal 3 80 % AM (1 khz) PASS (A) 80-1 000 Rear Horizontal 3 80 % AM (1 khz) PASS (A) 80-1 000 Right Horizontal 3 80 % AM (1 khz) PASS (A) 80-1 000 Left Horizontal 3 80 % AM (1 khz) PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 3.6.4 Photographs of Radiated, radio-frequency, electromagnetic field immunity test Configuration [Radiated, radio-frequency, electromagnetic field immunity test] Page Number : Page 40 of 51

3.7 Electrical fast transient/burst immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1 kv to AC power lines. 3.7.1 Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-4:2012 Test Date : February 06, 2017 Test Voltage : 1 kv(power lines) Performance criterion : B Temperature/Humidity/Pressure : 24 C / 36 % R.H. / 100.8 kpa 3.7.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES0801543 09. 10. 2017 3.7.3 Test Result of Electrical fast transient/burst immunity test Electrical fast transient/burst immunity test : PASS The equipment meets the requirements. Page Number : Page 41 of 51

Test data sheet follows. Line Voltage Coupling Inject Time (sec) Result L1-N-PE 1 kv Direct 120 PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 3.7.4 Photographs of Electrical fast transient/burst immunity test Configuration [Electrical fast transient/burst immunity test] Page Number : Page 42 of 51

3.8 Surge immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1.0 kv to AC Line to Line and 2.0 kv to Line to Ground. 3.8.1 Test Condition Test Voltage Test levels EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-5:2014 EUT Input : AC 230 V, 50 Hz Test Date : February 06, 2017 Test Voltage : 1.0 kv (Line to Line), 2.0 kv (Line to Ground) Performance criterion : C Temperature/Humidity/Pressure : 24 C / 36 % R.H. / 100.8 kpa Characteristics Self-ballasted lamps and semi-luminaires Test levels Device Luminaries and independent auxiliaries Input Power 25 W > 25 W Wave-shape data 1.2/50 µs 1.2/50 µs 1.2/50 µs Line to Line 0.5 kv 0.5 kv 1.0 kv Line to Ground 1.0 kv 1.0 kv 2.0 kv 3.8.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES0801543 09. 10. 2017 3.8.3 Test Result of Surge immunity test Surge immunity test : PASS The equipment meets the requirements. Page Number : Page 43 of 51

Test data sheet follows. Line Voltage (kv) Coupling Phase(Degree) Inject (count - min) Result L1-N (0.5, 1.0) kv 18 F 90, 270 5 times - 5 min PASS (A) L1-PE (0.5, 1.0, 2.0) kv 9 F, 10 Ω 90, 270 5 times - 5 min PASS (A) N-PE (0.5, 1.0, 2.0) kv 9 F, 10 Ω 90, 270 5 times - 5 min PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 3.8.4 Photographs of Surge immunity test Configuration [Surge immunity test] Page Number : Page 44 of 51

3.9 Conducted immunity test Tests were conducted in accordance with EN 61547:2009. Over the frequency range of 150 khz to 80 MHz. Tests were performed at 3 V on power line. 3.9.1 Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method EN 61000-4-6:2014 Test Date : February 06, 2017 Test Voltage : 3 V Performance criterion : A Temperature/Humidity/Pressure : 24 C / 36 % R.H. / 100.8 kpa 3.9.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use RF Power Amplifier 75A250 Amplifier Research 0325567 02. 28. 2017 Signal Generator SMT02 ROHDE & SCHWARZ DE27053 08. 09. 2017 Attenuator 100W6dB N/A N/A 03. 25. 2017 CDN FCC-801-M3-16A FCC 521345 05. 12. 2017 3.9.3 Test Result of Conducted immunity test Conducted immunity test : PASS The equipment meets the requirements. Page Number : Page 45 of 51

Test data sheet follows. Frequency Test port (MHz) Coupling Dwell time Modulation Step Size Result Power 0.15 80 CDN (M3) 1 s 80 % AM (1 khz) 1.0 % PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 3.9.4 Photographs of Conducted immunity test Configuration [Conducted immunity test] Page Number : Page 46 of 51

3.10 Voltage Dips and Short interruptions immunity test Voltage variations tests were conducted in accordance with EN 61547:2009. 3.10.1 Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-11:2004 Test Date : February 06, 2017 Voltage Dip : 70 % (10 period) Short interruptions : 0 % (0.5 period) Performance criterion : 70 % (10 period) - C, 0 % (0.5 period) - B Temperature/Humidity/Pressure : 24 C / 36 % R.H. / 100.8 kpa 3.10.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES0801543 03. 24. 2017 3.10.3 Test Result of Voltage Dips and Short interruptions immunity test Voltage Dips and Short interruptions immunity test : PASS The equipment meets the requirements. Page Number : Page 47 of 51

Test data sheet follows. Test voltage level % Number of periods Angle ( ) Criteria Result 70 10 0, 180 C PASS (A) 0 0.5 0, 180 B PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 3.10.4 Photographs of Voltage Dips and Short interruptions immunity test Configuration [Voltage Dips and Short interruptions immunity test] Page Number : Page 48 of 51

4. EUT PHOTOGRAPHS [Front of EUT] [Top of EUT] Page Number : Page 49 of 51

[Internal of EUT] Page Number : Page 50 of 51

[Front of Main Board] [Rear of Main Board] Page Number : Page 51 of 51