Series CL Three and four pole contactors 9 to 05 (C3) 25 to 40 (C) Contactors lternating current up to 690V Direct current up to 440V Terminal numbering in accordance with EN 50005 and EN 5002 Fixing by clipping onto 35mm DIN rail EN 50022-35 or by screws Screws protected against accidental contact in accordance with VDE 006 T.00, VBG4 Ring terminal version Three coil terminals Mounting possibilities of front/side instantaneous auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor block and interface modules Degree of protection: IP20 to CL00... CL02 IP0 to CL25... CL0 Maximum number of auxiliary contacts: 4 for CL00... CL25 6 for CL04... CL45 8 for CL06... CL0 Standards Standard voltages B C IEC/EN 60947- IEC/EN 60947-4- IEC/EN 60947-5- EN 50005 UL 508 NEM ICS BS 5424 & 775 CS 22.2/4 NFC 63-0 SE 025 VDE 0660/02 CENELEC HD 49 To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit. (other voltages on request)* lternating current (V). Dual-frequency coil 2 9 3 4 5 6 7 3 8 5 C 24 42 48 20 220 230 240 400 440 480 50/60Hz 5 D E F pprovals culus SETI IMQ (hasta Ith=32) lternating current (V). E K L N T U W Y Z C 32 27 220 380 45 500 660 50Hz 230 400 690 C 208 277 380 480 460 600 60Hz Direct current (V) For contactors type CL...D / Operating limits: 0.80....0 x Us B D E F G H I J K N P R T X G H Lloyd s Register Bureau Veritas RIN Voltage 2 24 36 42 48 60 72 20 220 230 240 250 440 25 Coil with electronic module for contactors CL...E (can also be used with alternating current) D F H J N Y Voltage 24 42 60 220 440 28 48 72 25 250 I X CE Order codes uxiliary contact blocks ccessories Dimensions pg. C. pg. C.5 pg. C.5 pg. C.24 Direct current (V). Coil with wide voltage range (0.70....30 x Us) For contactors type CL...D Coil with electronic module for contactors CL...E WB WD WE WF WG WH WI WJ WK WN WP WR WT WX DC 2 24 33 42 48 60 72 25 220 230 240 250 440 WD WE WF WH WJ WN Voltage 24 33 48 72 0 220 Maximun number of add-on auxiliary contact blocks: CL00D...CL02D : 2NO or NC CL03D...CL45D : NO and NC CL05D...CL0D : 4NO or 2NC CL05E...CL0E : 4 cont. aux. Different auxiliary contact configurations, contact us. * Please Consult GE for non standard Coil Voltages C.0
Series CL Three pole contactors. Screw terminal Max.oper.current Noninductive load C Motors <440V, 3 ~ 50/60Hz C3 25 9 25 2 32 8 45 25 45 25 60 32 60 40 dmissible power C3 220V 380V 45V 500V 230V 400V 440V kw kw kw kw HP HP HP HP Electrical ux. endurance contacts Cat. C3 Operations 2.2 4 4 5.5 2x0 6 0 0 3 5.5 5.5 7.5 0 3 5.5 5.5 7.5 2x0 6 0 0 4 7.5 7.5 0 4 7.5 7.5.7x0 6 0 0 5.5 3.5 0 7.5 5.2x0 6 0 0 5 5 20 7.5 2 2 5 2x0 6 0 0 6 6 2 0 9 6 6 8.5 2x0 6 0 0 2 22 22 25 0 8.5 22 25 2x0 6 0 0 5 25 30 34 3 4 2 lternating current Cat. no. () CL453M 0 Direct current Coil with electronic module (C/DC) Ref. no. see bottom Ref. no. see bottom Ref. no. see bottom CL00300T 5 CL0030T 5 CL0030T 5 CL0300T 5 CL030T 5 CL030T 5 CL02300T 5 CL0230T 5 CL0230T 5 CL25300T 5 CL03300M 0 CL0330M 0 CL0330M 0 CL04300M 0 CL0430M 0 CL0430M 0 CL45300M 0 Cat. no. () CL00D30T 0 CL00D30T 0 CL0D30T 0 CL0D30T 0 CL02D30T 0 CL02D30T 0 CL25D300T 0 CL03D30M 0 CL03D30M 0 CL04D30M 0 CL04D30M 0 CL45D300M 0 Cat. no. () 3P and 4P contactors 90 50 5 22 25 3.8x0 6 0 0 20 30 34 4 CL06300M CL063M CL06D300M CL06E300M B 0 65 8.5 30 37 4.7x0 6 0 0 25 40 50 55 CL07300M CL073M CL07D300M CL07E300M C 0 80 40 95 22 37 45 45.5x0 6 0 0 30 50 60 6 25 45 50 55.7x0 6 0 0 34 60 68 75 CL08300M CL083M CL09300M CL093M CL08D300M CL09D300M CL08E300M CL09E300M D 405 30 55 55 65.5x0 6 0 0 40 75 75 88 CL0300M CL03M CL0D300M CL0E300M E Spare coils CL00 - CL25 CL03 - CL45 CL06 - CL0 coil + electronic module CL06E - CL0E LB 5 LB3 5 LB4 5 LBD 5 LB3D 5 LB4D LB4E F G H () To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit (see C.0). Equipped with two blocks BCLF Multipack, see C.9 I X C.
20hp @ 460V C-3 Contactor Selection and Data (6 kw @ 380/45V, 50 Hz) C Contactors Full Voltage Non-Reversing CL0430M* Reversing LR04* DC Contactors Full Voltage Non-Reversing CL04D30M* Reversing LDR04* Maximum ux. Contacts 6 ux. Contacts 4 Front-Mount plus Side- Maximum Contact Block Mount, or 2 Front-Mount plus Configuration Side-Mount on each side ux. Contacts (600, P600) (Built in) NO Continuous mp Rating (UL) 54 C- mperes (IEC) 60 Max. FL 32 Max. Hp (-Phase) 5 Volts 2 230 Volts 5 C-2/C-3 Max. Hp (3-Phase) 200 Volts 0 230 Volts 0 460 Volts 20 575 Volts 25 200 Volts 0 C-4 Max. Hp 230 Volts 0 460 Volts 20 575 Volts 25 Mechanical Life (millions of operations) 20 Elec. Endurance (C-3) t Rated Current 2 (millions of operations) C- 200 ops./hour 54 Maximum Operational 3000 ops./hour 27 Current C-3 200 ops./hour 32 460V and 3000 ops./hour.2 Below C-4 360 ops./hour max 32 Net Weight 3-Pole Contactors 20 HP (460V) 32 FL Contactor catalog numbers are shown in the shaded area in the Contactor Selection and Data table. To complete the catalog number, replace the asterisk (*) with the appropriate digit from the shaded area in the Coil Selection table. dditional coil information is shown in the Coil Data table. Contactor Class 0 Overload Relay lb. 2 oz. 7 oz. Wire Size - Power Terminals 75 C (Cu) WG 4-8 Torque (Main) in.-lb. 6 Noise (dba) 25 Coil Selection C Voltage DC Coil * 60 Hz 50 Hz Voltage Suffix 24 24 2 B 24 D 48 42 F 48 G 20 J 25 K 208 L 277 220/230 M 240 S 250 T 480 380/400 U 45 W 600 500 Y C DC Voltage Voltage Burden Inrush 88 V 7.5 W Holding 9 V 7.5 W Pick-up Voltage (% Of Coil Volts) 85-0 80-0 Coil Data Drop-Out Voltage (% Of Coil Volts) 40-55 5-30 Switching Delay (ms) Switching Delay On Coil Voltage at +0% to -20% 7-25 35-70 Coil Voltage t Rated Value 0-9 40-65 Switching Delay Off Coil Voltage at +0% to -20% 5-25 40-65 Coil Voltage t Rated Value 5-25 40-65 Maximum Operations per Hour No Load 9000 3600 Rated Load C, C3 20200 Rated Load C4 360 360 REFERENCES Standards and Listings...Page 4 Overload Relays...Pages 26-29 ccessories...pages 30-37 Life Curves...Pages 42-44 dditional Coil Information...Page 37 Instruction Sheet...GEH-6224 UL File Number...E76233 CS File Number...LR3082 6
C-2000 Contactors & Starters 3-Pole Contactors 20 HP (460V) 32 FL Legend and Notes for Illustration Extra uxiliary Contacts, Side Mounted (if used) B Extra uxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor dd 2 inch for electrical clearance to enclosure. 4 mounting holes for #8 or M4 Screws Contactor - Front View Starter - Front View Engineering Outline Drawings C Contactor...55-25783 Starter...55-25825 Reversing Contactor...55-25792 Reversing Starter...55-25793 DC Contactor...55-25836 Starter...55-25869 Reversing Contactor...55-25777 Reversing Starter...55-25808 Reversing Contactor - Front View Reversing Starter - Front View DC Contactor - Side View C Contactor - Side View C Starter - Side View 7
Standards nd Listings IEC 947- BS 5424 CS C.22.2/4 IEC 947-4 BS 775 EN 50005 IEC 58- CEI 7-3/252 UNE 2009 GENELEC HD49 SE 025 VDE 0660/02 NFC.63-0 UL 508 CE Mark C-2000 Contactors & Starters General Specifications Pending Standards nd Listings mbient Temperature Operating Storage SEMKO, NEMKO, DEMKO, Lloyds Register -3 to +3 F/-25 to +55 C -58 to +76 F/-50 to +80 C ltitude Derating Up to 0,000 ft. Nominal Values (3,000 m) 0,000 to 3,200 ft. 90% rated current (3,000 to 4,000 m) 3,200 to 6,000 ft. 80% rated current (4,000 to 5,000 m) Rated Insulation Voltage 600 VC, U I = 000V (IEC 947-) Mounting Position 3-Pole and 4-Pole CL Contactors (5-75 hp) To maintain operating integrity, the contactor must be mounted in one of the positions shown below: 3-Pole and 4-Pole CK Contactors (00-500 hp) The contactor must be installed vertically or tilted a maximum of 30 from vertical, as shown below: 4