Temperature Sensor G1/2" Standard

Similar documents
Temperature Sensor G1/2" Standard

Temperature Sensor with M12 hygienic

Pharma-Temperature Sensor M12 hygienic

Temperature Sensor without thread

Temperature Sensor with M12 hygienic

Pharma Temperature Sensor G3/8"

Temperature Sensor with G1/2" hygienic

Temperature Sensor with Thread G1/4" FLEXadapt

Temperature Sensor Tri-Clamp

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor Tri-Clamp

Temperature Sensor for Build-In System G3/8" FLEXadapt

Pharma Temperature Sensor G3/8"

Temperature Sensor Tri-Clamp

Pharma Temperature Sensor TFP-EX

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Continuous Level Sensor NSL-M

Inductive Conductivity Meter ILM

Capacitive Limit Switch Pharma NCS

Capacitive Limit Switch Pharma NCS

Capacitive Limit Switch Pharma NCS

Continuous Level Sensor NSL-M-00

Magnetic-Inductive flow Meter fmi

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

ph or ORP Transmitter

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Model TR33, thread-mounted

Screw-in resistance thermometers with plug connector

Resistance thermometer Model TR30, compact design

Digital inductive conductivity transmitter

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR30, compact design

Conductivity Transmitter

RoHS. High shaft load capacity. Shock / vibration resistant

Mineral-insulated resistance thermometers to EN

INLINE flowmeter for continuous flow measurement

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Absolute Encoders - Singleturn

Resistance thermometer Model TR31, miniature design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Valve Island with Electronic I/O

OPTITEMP TT 20 Technical Datasheet

Digital flow ELEMENT transmitter for continuous flow measurement

Resistance Thermometers Model Series TR7X0, Sheathed Design

INSERTION paddle wheel flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

PLATINUM SENSORS FOR MEASURING TEMPERATURES UP TO 400 C 28.11a

CombiTemp TCR6 Standard RTD temperature sensor

Float switch For industrial applications, plastic version Model RLS-2000

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Rotary Measurement Technology Incremental Encoders

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a

Absolute Encoders - Singleturn

Digital flowmeter for continuous flow measurement

Ultrasonic level transmitter, non-contact

Electromagnetic Flow Transmitter

ENCODER. SSI Multiturn. Series , Key-Features: Content:

Pressure transmitter for general industrial applications Model A-10

Technical Information Memosens CLS82D

Absolute Encoders Multiturn

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

ENCODER. Analog Multiturn Encoder. Serie 8.M5861. Key-Features:

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

Resistance thermometers for process technology

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Technical Information Smartec CLD18

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

INLINE flowmeter for continuous flow measurement

Screw-in resistance thermometers with terminal head Form B

ED701 General Industry Pressure Transmitter

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Hygro-ThermoTransmitter-compact xxx

Phone: Fax: Web: -

Absolute Encoders Singleturn

In-Line Resistance Thermometers Model TR25

Rotary Position Technology Incremental Encoders

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:

Pressure transmitter for general industrial applications Model A-10

High-quality pressure transmitter For general industrial applications Model S-10

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Inductive Standard Displacement Transducers

Technical Information Smartec CLD18

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure Transmitter SIL

Transcription:

SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-40, -50, -60, -160, -180 FOOD Temperature Sensor G1/2" Standard Application / Specified Usage Temperature measurement in vessels and pipes No product contacting of the sensor if using the weld-in thermowell ESH Demounting the sensor without opening the process if using the weld-in thermowell ESH Authorizations Application Examples Temperature measurement in pressure pipes Measurement of paste products in pipes Temperature monitoring in UHT-plants Temperature sensor TFP-40 Hygienic Design / Process Connection Hygienic and easy sterilizable installation by using thermowell ESH Product contacting materials compliant to FDA Sensor and thermowell completely made of stainless steel Features Integrated transmitter optional Different types of electrical connections possible Protection class is IP 69 K with electrical connection M12-plug Options / Accessories 2 x Pt100 (not retrofittable) 2 x Pt100 with two transmitters (not retrofittable) Programmable transmitters MPU-4 as well as MPU-M with output 4...20 ma, 2-wire Integrated transmitters for Profibus PA and HART-protocol Programming adapter MPU-P 9701 Integrated transmitter MPU-LCD with display in connecting head Pt100 chip with other classes of accuracy (1/3B, 1/10B) Fast response sensor tip 3 mm and 4 mm Spacer for high temperature up to 250 C permanent temperature up to 450 C (on request) Pre-assembled connecting cable for M12-plug Fixed cable in other lengths and material available Temperature sensor TFP-160 /... / MPU-M

FOOD Specification 2 Temperature sensor Process connection thread G1/2" gap-free with weld-in thermowell, e.g. ESH-G1/2"/050 Insertion length standard 35...500 mm (inclusive thread) Materialis Operating pressure Temperature ranges connecting head thermowell without weld-in thermowell with weld-in thermowell ambient sensor tip Sensing resistor acc. to DIN EN 60751 Pt100 Electrical connection Protection class cable gland cabel connection fixed cable 2.5 m fixed cable 2.5 m ( 90 C) stainless steel 1.4305 stainless steel 1.4404 10 bar maximum 50 bar maximum -50...+80 C -50...+250 C M16 x 1.5 M12-plug 1.4305, 4-pins LIYY 4 x 0.25 mm² PTFE 4 x 0.14 mm² IP 69 K (with electrical connection M12-plug) Transmitter MPU-4, MPU-10, MPU-H, MPU-M Temperature ranges Measuring ranges ambient storage MPU-4, MPU-H, MPU-M MPU-10-40...+85 C -55...+90 C Accuracy input < ±0.25 C Temperature drift zero, span < 0.01 % / K Supply Output MPU-M, MPU-4 MPU-10 accuracy signal accuracy burden Humidity without condensation 0...98 % standard: -10...40 C, 0...50 / 100 / 150 / 200 C special ranges free programable standard: -200...850 C configuration occurs with Profibus 8...35 V DC 9...32 V DC 0.01 % / V (reference: 12 V DC) analog 4...20 ma (not for MPU-10) < ±0.1 % of measurement range < 600 Ω (at U B = 24 V) Accuracy classes of temperature sensors Tolerances for Pt100 acc. to DIN EN 60751 Pt100 A 1/3 B 1/10 B 0 C / 100 Ω ±0,15 K / ±0,06 Ω ±0,10 K / ±0,04 Ω ±0,03 K / ±0,01 Ω 100 C / 138,5 Ω ±0,35 K / ±0,13 Ω ±0,27 K / ±0,10 Ω ±0,08 K / ±0,03 Ω

3 Electrical Connection FOOD Elektrischer Electrical connection Anschluss without ohne Kopftransmitter Elektrischer Electrical connection Anschluss with mit Kopftransmitter With 1 x M12 plug Belegung Configuration 1. M12-Stecker 1st plug 1 2 3 4 M12-Stecker With plug Configuration Belegung M12 plug M12-Stecker 1: + supply 2: - supply 4...20 ma 3: not connected 4: not connected With 2 x M12 plug Mit With Kabelverschraubung cable gland Belegung Configuration 2. M12-Stecker 2nd plug 1 2 3 4 PLC 4...20 ma current Stromschleife loop With cable gland Belegung Configuration Klemmen strip terminal 1 2 3 4 Pt100 Electrical connection with two transmitter (TFP-60) With fixed cable Klemmen clamps for für 1st 1. Pt100 Klemmen clamps for für 2nd 2. Pt100 (bei (at version Ausführung 2 x Pt100) 2 x Pt100) Belegung Fixed cable Kabel connection mit 1 with x Pt100 1 x Pt100 wh ws ge ye bn br gn Standard standard rd rt rd rt ws wh ws wh PTFE Pt100 With 1 x M12-plug (sensor 1 + sensor 2) With 2 x M12-plug (sensor 1) Configuration M12-plug 1: + supply (sensor 1) 2: - supply 4...20 ma (sensor 1) 3: - supply 4...20 ma (sensor 2) 4: + supply (sensor 2) Configuration M12-plug 1: + supply (sensor 1) 2: - supply 4...20 ma (sensor 1) 3: not connected 4: not connected Belegung Fixed cable Kabel connection mit 2 with x Pt100 2 x Pt100 (LIYY) (LIYY) wh ye bn gn 1st Pt100 rd bu pk gy 2nd Pt100 Pt100 Fixed Belegung cable Kabel connection mit with 2 x Pt100 2 x Pt100 (PTFE) (PTFE) rd rd wh 1st Pt100 vt vt ye 2nd Pt100 Pt100 With 2 x M12-plug (sensor 2) Configuration M12-plug 1: + supply (sensor 2) 2: - supply 4...20 ma (sensor 2) 3: not connected 4: not connected

FOOD Dimensional Drawings 4 TFP-40 TFP-40.2 TFP-60 TFP-50 TFP-50.2 52 59 52 Important installation advice Tighten the sensor only at the lower spanner flat (BE = 22 mm)! TFP-160 TFP-160 /... / MPU-M TFP-180 TFP-180.2

5 Dimensional Drawings FOOD Sensor tip diameter and response time All temperature sensors are available with smaller sensor tips, to ensure a shorter response time. The below-mentioned times were measured by emersing a temperature sensor from room temperature into boiling water. Sensor tip Ø 6 mm with thermowell Sensor tip Ø 6 mm Sensor tip Ø 4 mm Sensor tip Ø 3 mm 50 %-time: t 50 8.8 s 90 %-time: t 90 24.5 s 50 %-time: t 50 3.0 s 90 %-time: t 90 8.0 s 50 %-time: t 50 2.4 s 90 %-time: t 90 6.5 s 50 %-time: t 50 0.5 s 90 %-time: t 90 1.5 s Ø6 Ø6 Ø6 Ø6 Ø8,8 Ø4 Ø3 Thermowell ESH-G1/2" Note When using weld-in thermowells we recommend to use heat-conductive paste too. This can reduce the response time up to 50 %. Detailed Information to Thermowell ESH you will find in product information CLEANadapt.

FOOD Advices Option MPU-LCD 6 Mechanical Connection / Installation Check the compatibility of the sensor length to the used thermowell. Conventional Usage Not suitable for applications in explosive areas. Not suitable for applications in security-relevant equipments (SIL). Transport / Storage No outdoor storage Dry and dust free Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage temperature -55...+90 C Relative humidity maximum 98 % Cleaning / Maintenance In case of using pressure washers, dont t point nozzle directly to electrical connections! Standards and Guidelines You have to comply with applicable regulations and directives. Note on CE Applicable directives: Electromagnetic Compatibility Directive 2014/30/EU Compliance with the applicable EU directives is identified by the CE label on the product. The operating company is responsible for complying with the guidelines applicable to the entire installation. Reshipment Sensors shall be clean and free of media or heatconductive paste and must not be contaminated with dangerous media! Use suitable transport packaging only to avoid damage of the equipment! Disposal Electrical devices should not be disposed of with household trash. They must be recycled in accordance with national laws and regulations. Take the device directly to a specialized recycling company and do not use municipal collection points. Temperature Transmitter MPU-LCD with Display Application / Specified Usage 4...20mA transmitter with LCD for Pt100 temperature sensor For installation in temperature sensor Sensor monitoring Option MPU-LCD (display in the connection head) Features 4-digit display with green backlight Temperature measurement in C and F Easy range select by one button Lower costs for wiring because of 2-wire technology Note See product information MPU-LCD for details.

7 Order Code TFP-40, -50, -160, -180 FOOD Order code for version with 1 x Pt100 TFP-40 TFP-50 TFP-160 TFP-180 (connecting head Ø 55 mm (connecting head Ø 55 with spacer) (connecting head Ø 18 mm, electrical connection via M12-plug) (connecting head Ø 18 mm,electrical connection via 2,5 m PVC-cable; other lengths: see accessories; no transmitter possible) Sensor Length EL in mm incl. thread connection 16,5 mm! 035...500 (in steps of 5 mm) xxx (special length) Diameter thermowell in mm 6 8 10 12 Diameter sensor tip in mm X (no reduction) 3 (only with thermowell 6 mm) 4 (only with thermowell 6 mm and 8 mm) 6 (only with thermowell 8 mm and 10 mm) 8 (only with thermowell 12 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (not selectable at TFP-160 and -180) PG (cable gland M16x1,5) M12 (M12 plug, standard with MPU-LCD) Transmitter X (without) for TFP-40 and -50 MPU-4 (programmable) MPU-10 (Profibus PA) MPU-H (HART-protocol) MPU-LCD (with display) only for TFP-160 (not for TFP-180) MPU-M (programmable) Measuring range MPU (only for types with transmitter; not for MPU-LCD) -10...40 C 0...50 C 0...100 C 0...150 C 0...200 C xx...yy (special range) TFP-40 / 100 / 6 / 6 / A / M12 MPU-4 / 0...100 C Accessories PVC-cable with M12-connection PVC-cable with M12-connection made of 1.4305, IP 69 K, unshielded M12-PVC / 4-5 m M12-PVC / 4-10 m M12-PVC / 4-25 m PVC-cable 4-pin, length 5 m PVC-cable 4-pin, length 10 m PVC-cable 4-pin, length 25 m

FOOD Product Information TFP-40, -50, -60, -160, -180 8 Order code for version with 2 x Pt100 TFP-40.2 TFP-50.2 TFP-60 TFP-60-H TFP-180.2 (connecting head Ø 55 mm, 2 x Pt100, no transmitter possible!) (connecting head Ø 55 mm, 2 x Pt100, with spacer, no transmitter possible!) (higher connecting head Ø 55 mm, 2 x Pt100, prepared for 2 x transmitter) (like TFP-60, but with spacer) (connecting head Ø 18 mm, electrical connection 2,5 m PTFE-cable; other lengths: see at accessories) Sensor Length in mm, incl. thread connection piece 16,5 mm! 035...500 (in steps of 5 mm) xxx (special length) Diameter thermowell in mm 6 8 10 12 Diameter sensor tip in mm X (no reduction) 3 (only with thermowell 6 mm) 4 (only with thermowell 6 mm and 8 mm) 6 (only with thermowell 8 mm and 10 mm) 8 (only with thermowell 12 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (only for TFP-40.2 and TFP-50.2) PG (cable gland M16x1,5) 2PG (2 x cable gland M16x1,5) 2M12 (2 x M12-plug) Electrical connection (only for TFP-60 and TFP-60-H) M12 (M12-plug) 2M12 (2 x M12-plug) Continue if TFP-60 oder TFP-60-H is selected! No further options for TFP-40.2, -50.2, -180.2! 1. Transmitter MPU-4 (programmable) Measuring Range 1. MPU -10...40 (measuring range -10...40 C) 0...50 (measuring range 0...+50 C) 0...100 (measuring range 0...+100 C) 0...150 (measuring range 0...+150 C) 0...200 (measuring range 0...+200 C) xx...yy (special range) 2. Transmitter MPU-4 (programmable) Measuring Range 2. MPU -10...40 (-10...40 C) 0...50 (0...+50 C) 0...100 (0...+100 C) 0...150 (0...+150 C) 0...200 (0...+200 C) xx...yy (special) TFP-60 / 100 / 6 / X / A / M12 / MPU-4 / 0...50 / MPU-4 / 0...50 50006 / 6.1 / 2018-08-08 / AR / EU NEGELE MESSTECHNIK GMBH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720