BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

Similar documents
SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

DWDM SFP+ Series DWDM EML

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

Part No. Data Rate Wavelength Interface Temp. DDMI /1.25Gbps 1310nm SC Industrial NO EOLS-BI I

SFP Series. Features. Applications. Ordering information. Single-Mode 155Mbps SC Single-Fiber SFP Transceiver RoHS6 Compliant

4.25Gbps SFP Transceiver

SFP Series EOLS-BI Series EOLS-BI Series

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

DWDM SFP Series. Laser

SFP28 Series Preliminary EOLP-8525G-02-R. Features. Applications. Ordering information

SFP Series. EOLS X Series. Features. Applications. Ordering Information

2.5Gbps SFP Transceiver

OCTECH 1.25Gbps SFP Transceiver

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

1.25Gbps SFP Transceiver

DWDM SFP Series. DIxx-SFP-LC.S120. Features. Applications. Ordering Information

SFP Series. EOLS-1348-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm FC/2FC/4FC Duplex SFP Transceiver RoHS6 Compliant

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

850nm SFP28 Multi-Mode Transceiver, With Diagnostic Monitoring and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type.

SFP+ Series EOLP M-I. Features. Applications. Ordering information

SO-SFP-1000BASE-ZXD-I

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

OCTECH 1.25Gbps SFP Transceiver

SFP Series. EOLS-BI CL XX Series EOLS-BI LC XX Series. Features. Applications. Ordering Information

SFP+ BIDI Series GigaStream BIDI-10G-SFP-40A & BIDI-10G-SFP-40B

Fiber Distance* (note2) Temp. Connector DDM

SO-CSFP-100Base-BX20D-34-O2 -I

SFP Series IOLS-1624-XX-XX. 2.5Gbps APD High Sensitivity Receiver. version 0.1 FEATURES PRODUCT DESCRIPTION

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

SFP-BIDI G 1310/1490nm BIDI

SFP+ Series SFP-10G-SR

SFP+ BIDI Series JB1270-SFP-LC.S20

SFP+ Series. 1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

DWDM SFP+ Series DWDM EML DWDM EML

SFP Series EOLS X. Features. Applications. Ordering Information

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

DWDM SFP+ Series. EOLP XXXN series. Features. Applications. Ordering Information

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP Series. EOLS-1312-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm 1.25Gbps FC/GBE Duplex SFP Transceiver RoHS Compliant

SFP Series. Distance * (note2) Interface Temp. DDMI

Regulatory Compliance Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge To the enclosure Elect

CWDM EML. SMF 23dB YES LC. note1: X refers to CWDM Wavelength range 1470nm to 1610nm, X=K~R, denotes 1470~1610nm.

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note1) Interface Temp. DDMI.

SFP+-10GB-ZR. 10Gbps SFP+ Optical Transceiver, 80km Reach

SFF Series EOLF Series EOLF Series

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

SFP+-CWDM-xx-40D. 10Gbps CWDM SFP+ Optical Transceiver, 40km Reach

DWDM SFP+ Series. EOLP XXXN MSA Series. Features. Applications. Ordering Information

SFP+ Series EOLP Features. Applications. Ordering information

DATASHEET 4.1. SFP, 100Mbps-2.7Gbps, Multirate, 1310nm, SM, DDM, 8dB, 2km, ind.temp.

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP+-DWDM-xx-80D. 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach

SFP+ Series EOLP XN MSA Series

SFF Series EOLF Series

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

SFF Series. EOLF Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1250Mbps Duplex SFF Transceiver RoHS6 Compliant

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-EW/ER Duplex SFP+ Transceiver, RoHS 6 Compliant. Fiber Type.

SFP+ BIDI Series EOLP-BI1696-9ADL & EOLP-BI1696-9DAL Series

ASF Features. Applications. 1310nm SFP Single-Mode for 1.25G FC/GBE Duplex SFP Transceiver RoHS 6 Compliant

DWDM SFP Series. Power budget* (note2) Laser

SNR-SFP+W73-20 SNR-SFP+W db Power Budget BIDI SFP+ 10GbE Transceiver

XFP Series. JCxxxx-XFP-LC.S40. Features. Applications. Ordering Information

Optical Transceiver Module - SFP

Part No. Data Rate Wavelength Interface Temp. DDMI

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

SFP+ Tunable Preliminary. EOLP-1696-TDW-23XXXN MSA Series. Features. Applications. Ordering Information

Part No. Data Rate Fiber Distance Interface Temperature DDMI

DWDM SFP+ Series EOLP XXN MSA Series

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gbps CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

SFP Series. Fiber Distance* (note2) Interface Temp. DDMI

DWDM SFP Series. Power budget* (note2) Laser

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SNR-SFP+LR-2 10Gbps. Applications 10GBASE-LR at 10.31Gbps 10GBASE-LW at 9.95Gbps Other optical links

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

DWDM SFP+ Transceiver With Digital Diagnostic Function

Fiber Distance* (note2) Interface Temperature DDMI Rate

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

Fiber Channel Links Standard: 0 ~+70 Industrial: -40 ~+85 Compliant with GBIC Specification Rev. 5.5

PON Series. EOLS-GN- 25-XX Series. Features. Applications. Ordering Information. Link Budget. Input/ Output. DDMI Interface Temp. Part No.

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

WDM SFP+ модули предназначены для создания каналов связи по одноволоконному SM кабелю на расстояние до 20км.

XFP Series. JCxxxx-XFP-LC.S80. Features. Applications. Ordering Information

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

DWDM SFP Series. Power budget* (note2) Laser

PERFORMANCE SPECIFICATIONS - ELECTRICAL

SFP Series. EOLS X Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1xFC /GBE Duplex SFP Transceiver RoHS6 Compliant

Features Gigabit Ethernet

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

Part No. Input Output Burst-mode Fiber Interface Temp.

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

Transcription:

GB1310-SFP-SC.S10 GB1550-SFP-SC.S10 Single-Mode 100Mbps to 1.25Gbps FE/GBE SC Single-Fiber SFP Transceiver RoHS6 Compliant Features Support 1.25Gbps Data Links A type: 1310nm FP TX /1550nm RX B type: 1550nm DFB TX /1310nm RX 10km with 9/125 µm SMF Single 3. 3V Power supply and TTL Logic Interface Hot-Pluggable SFP Footprint Simplex SC Connector Interface Class 1 FDA and IEC60825-1 Laser Safety Compliant Operating Case Temperature Applications Fiber Channel Links WDM Gigabit Ethernet Links Other Optical Links FTTX Applicatio Standard: 0 ~+70 Industrial:-40 +85 Compliant with SFP MSA Specification Compliant with Digital Diagnostic Monitor Interface SFF-8472 Ordering Information Part No. Data Rate Wavelength Interface Temp. DDMI GB1310-SFP-SC.S10 GB1550-SFP-SC.S10 GB1310-SFP-SC.S10(WT) GB1550-SFP-SC.S10(WT) 1.063/1.25Gbps 1310nm SC Standard YES 1.063/1.25Gbps 1550nm SC Standard YES 1.063/1.25Gbps 1310nm SC Industrial YES 1.063/1.25Gbps 1550nm SC Industrial YES Note1: Standard version Page 1 of 9

Regulatory Compliance* Note2 Product Certificate Certificate Number Applicable Standard TUV R50135086 EN 60950-1:2006+A11+A1+A12 EN 60825-1:2007 EN 60825-2:2004+A1+A2 UL E317337 UL 60950-1 CSA C22.2 No. 60950-1-07 EMC CE AE 50285865 0001 EN 55022:2010 EN 55024:2010 CB JPTUV-049251 IEC 60825-1 IEC 60950-1 FCC WTF14F0514437E 47 CFR PART 15 OCT., 2013 FDA 1331340-000 CDRH 1040.10 ROHS RHS01G006464 2011/65/EU Note2: The above certificate number updated to June 2014, because some certificate will be updated every year, such as FCC, FDA and ROHS. For the latest certification information, please check with. Product Description The GB1310/1550-SFP-SC.S10 series is small form factor pluggable module for Gigabit Ethernet 1000BASE-BX and Fiber Channel single fiber applications by using 1310nm / 1550nm transmitter and 1550nm / 1310nm receiver. It is with the SFP 20-pin connector to allow hot plug capability. The transmitter section uses a multiple quantum well A type / B type laser and is a class 1 laser compliant according to International Safety Standard IEC 60825. The receiver section uses an integrated B type / A type detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. The GB1310/1550-SFP-SC.S10 series are designed to be compliant with SFF-8472 Multi-source Agreement (MSA). Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Temperature Ts -40 +85 C Supply Voltage Vcc -0.5 3.6 V Operating Relative Humidity - 95 % *Exceeding any one of these values may destroy the device immediately. Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit Operating Case GB1310/1550-SFP-SC.S10 0 +70 Temperature Tc GB1310/1550-SFP-SC.S10(WT) -40 +85 C Power Supply Voltage Vcc 3.15 3.3 3.45 V Power Supply Current Icc 300 ma FC 1.063 Gbps Date Rate GBE 1.25 Gbps Page 2 of 9

Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes LVPECL Inputs(Differential) Input Impedance (Differential) TX_Dis TX_FAULT LVPECL Outputs (Differential) Output Impedance (Differential) RX_LOS MOD_DEF ( 0:2 ) Transmitter Vin 400 2000 mvpp Zin 85 100 115 ohm Disable 2 Vcc+0.3 Enable 0 0.8 Fault 2 Vcc+0.3 Normal 0 0.5 Receiver Vout 400 2000 mvpp Zout 85 100 115 ohm LOS 2 Vcc+0.3 V Normal 0 0.8 V Optical and Electrical Characteristics VoH 2.5 V VoL 0 0.5 V (GB1310-SFP-SC.S10, 1310nm FP and PIN, 10km) V V AC coupled inputs* (note5) Rin > 100 kohm @ DC AC coupled outputs* (note5) With Serial ID Parameter Symbol Min. Typical Max. Unit 9µm Core Diameter SMF L 10 km Data Rate 1063/1250 Mbps Transmitter Center Wavelength λc 1270 1310 1350 nm Spectral Width (RMS) Δλ 3.5 nm Average Output Power* (note3) Pout -9-3 dbm Extinction Ratio @ 1250Mbps ER 6 9 db Rise/Fall Time(20%~80%) tr/tf 0.26 ns Total Jitter TJ 260 ps Output Optical Eye* (note4) Compliant with IEEE 802.3ah-2004* (note7)) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Receiver Center Wavelength λc 1530 1550 1570 nm Receiver Sensitivity* (note6) @1250Mbps Pmin -21 dbm Receiver Overload Pmax -3 dbm LOS De-Assert@1250Mbps LOSD -22 dbm LOS Assert LOSA -35 dbm LOS Hysteresis* (note8) 0.5 db Page 3 of 9

(GB1550-SFP-SC.S10 1550nm DFB and PIN, 10km) Parameter Symbol Min. Typical Max. Unit 9µm Core Diameter SMF L 10 km Data Rate 1063/1250 Mbps Transmitter Center Wavelength λc 1520 1550 1580 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note3) Pout -9-3 dbm Extinction Ratio @ 1250Mbps ER 6 9 db Rise/Fall Time(20%~80%) tr/tf 260 ps Output Optical Eye* (note4) Compliant with IEEE 802.3ah-2004* (note7) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Receiver Center Wavelength λc 1260 1360 nm Receiver Pmin -21 dbm Sensitivity* (note6) @1250Mbps Receiver Overload Pmax -3 dbm Return Loss 12 db Optical Path Penalty 1 db LOS De-Assert@1250Mbps -22 dbm LOSD LOS De-Assert@100Mbps -22 dbm LOS Assert LOSA -35 dbm LOS Hysteresis* (note8) 0.5 db Note3: Output is coupled into a 9/125μm single-mode fiber. Note4: Filtered, measured with a PRBS 2 7-1. Note5: LVPECL logic, internally AC coupled. Note6: Measured at all data rates specified in Data Rate table with ER=9 db, 27-1 PRBS data pattern, BER <1E-12. Note7: Eye Pattern Mask Note8: LOS Hysteresis Page 4 of 9

Functional Description of Transceiver SFP Transceiver Electrical Pad Layout Page 5 of 9

Pin Function Definitions Pin NO. Name Function 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates Page 6 of 9 Plug Seq. Notes 1 VeeT Transmitter Ground 1 5) 2 TX Fault Transmitter Fault Indication 3 1) 3 TX Disable Transmitter Disable 3 2) Module disables on high or open 4 MOD-DEF2 Module Definition 2 3 3) Data line for Serial ID. 5 MOD-DEF1 Module Definition 1 3 3) Clock line for Serial ID. 6 MOD-DEF0 Module Definition 0 3 3) Grounded within the module. 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 4) 9 VeeR Receiver Ground 1 5) 10 VeeR Receiver Ground 1 5) 11 VeeR Receiver Ground 1 5) 12 RD- Inv. Received Data Out 3 6) 13 RD+ Received Data Out 3 6) 14 VeeR Receiver Ground 1 5) 15 VccR Receiver Power 2 7) 3.3 ± 5% 16 VccT Transmitter Power 2 7) 3.3 ± 5% 17 VeeT Transmitter Ground 1 5) 18 TD+ Transmit Data In 3 8) 19 TD- Inv. Transmit Data In 3 8) 20 VeeT Transmitter Ground 1 5) Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 10 KΩ resistor. Its states are: Low (0 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K 10K resistor on the host board. The pull-up voltage shall be VccT or VccR. Mod-Def 0 is grounded by the module to indicate that the module is present Mod- Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID

normal operation. In the low state, the output will be pulled to < 0.8V. 5) VeeR and VeeT may be internally connected within the SFP module. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. 7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and isthus not required on the host board. EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2H. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3. Page 7 of 9

Recommended Circuit Schematic Page 8 of 9

Mechanical Specifications SC Laser Emission Obtaining Document You can visit our website: http://www.dci.jp Or contact. listed at the end of the documentation to get the latest document. Revision History Revision Revision History Release Date V1.2 Released. Mar. 2010 Updated Optical Specification Mar.2018 Notice: reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add:9F Onoue Boueki Ueno Bldg., 3-17-4 Ueno, Taito-ku, Tokyo Japan. 110-0005 Tel: (+81) 3-3836-5611 FAX: +81-3-3836-5614 E-mail: info@dci.jp http://www..com Page 9 of 9