FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

Similar documents
FREQUENCY-CONVERTER MFR 600A

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Operating Instructions. for. Controller SMS 150 / 151

Series BDF for Process

Amplifier Series BASIC. Installation & Operations Manual

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

Sine Wave Power Inverter GD150/GD300 Series User s Manual

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

Silencer Series Brushless Controllers

POWER SUPPLIES SPS1000 SERIES CIRCUIT DESCRIPTION AND OPERATING MANUAL

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

SX (400V) System configuration

OPERATING INSTRUCTION

Brief description of KR 15 controllers

ATBG280/6 Bench Grinder Bench Grinder ATBG280/6 230V-50Hz 280 Watt 150mm x 25mm Wheel size

BC145 SIGNAL ISOLATOR BOARD

SX (400 V) System configuration

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

AMM-1022 Digital Multimeter USER`S MANUAL

400 (±2,5 V/ V/ ,3% V4A

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

Operating Instructions. for. Controller SMS 160 / 161

Industrial motor controller for brushed DC motors 24 VDC

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

TOSVERT VF-PS1 series BACnet option unit Instruction Manual BCN001Z

OLA2 Open Loop Amplifier. Installation and Operating Manual Release May 2013

Kattegat JP Groningen, The Netherlands High Efficiency High Power Audio SMPS

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

SX (690 V) System configuration

SCA-SS (70V, 10A)

USER'S MANUAL DMR-6700

INSTRUCTION MANUAL (ATEX / IECEx)

Power supply CP-D 24/4.2 Primary switch mode power supply

SMPS1200A400 SMPS1200A700

Vert-X 31E - 5V / % Ub. Applications Concrete pump Access control system Fork lift

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Analog Servo Drive 30A20AC

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

VT1586A Rack Mount Terminal Panel Installation and User s Manual

EN 50178, IEC

DMM8900 SERIES USERS MANUAL

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Manual SCA-SS V /02 page 1

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Electrical Multimeter

6/24/02 DigiMod 500 DigiMod 1000 DigiMod 1500 DigiMod 2000HV DigiMod 1000NPS. User Manual

KSC-10 Kelvin Speed controller 10A Rev.00 of 23/01/17

MINI-PS AC/2X15DC/1

TOSVERT VF-PS1 series Metasys N2 option unit Instruction Manual MTS001Z

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

MAC-AFRIC USER S MANUAL MODEL: D.C.INVERTER WELDER 160/200 AMP

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

SET Installation and Operating Instructions. Level switch for two sensors

External brake resistor AX2090-BW5x

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Power supply CP-E 24/2.5

Model 4007DDS. 7 MHz Sweep Function Generator

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

Capacitive Proximity Sensor

Disc Gap Control DGC-2. Technical Manual

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

DigiMod 3000PFC DigiMod 3000PFCsu

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Power supply CP-E 24/20.0

Vert-X 31E - 24V / SPI. Applications Concrete pump Access control system Fork lift

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

DVM1190 DIGITAL MULTIMETER

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Vert-X 27E - 24V / 4-20mA. Applications Harvesting machine Fork lift Hydraulic pump

Dynamo Brushless DC Motor and GreenDriveTM Manual

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Emotron FDU 2.0 Variable Speed Drive

LT3000 ULTRASONIC LEVEL TRANSMITTER

Electrical Multimeter

Hydraulic Valve Interface Products

NX series Constant and variable torque Variable Speed Drives for induction motors

Owner s Manual Rev 2.0

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Technical Document. for the. CB 016N6 Driver Card

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

TOA 500 SERIES MIXER POWER AMPLIFIER

MRG 96RM-E Flex RCM Mobile universal measurement device Supplementary description to the operation manual UMG 96RM-E

maxon motor maxon motor control 1-Q-EC Amplifier DECS 50/5 Order number

Transcription:

Technical documentation for: FREQUENCY-CONVERTER MFR 600A / 1500A Version 2 Contents: 1. General description 2. Technical data 3. Function of the ramp generator 4. Electrical connection, examples for the control 5. Mechanical dimensions, assembling 6. Start of operation, adjustments 7. Safety considerations 1. General description The frequency converter MFR 600 / MFR 1500 are designed for the speed - variation of standard 3-phase asynchronious induction motors from zero up to an adjustable maximum speed. The mechanical design provides the assembling instead of the normal terminal case of a standard motor. By use of corresponding sealings protection levels up to IP68 are possible. The main advantage of the assembling on the motor is the fact, that the connections to the motor are inside of the closed metal case. This is very important because the radiation of this connections is prohibited and there is also no capacitive load for the inverter to drive. This reduces both the power losses and the RFI level on the mains. The drives are working with a chopper frequency of appr. 10 khz ( switchable to 15kHz ), providing smooth running of the motor also in the low speed region. The drives are designed for 2-quadrant operation ( driving in both directions ). Braking is possible up to a power level equal to the power losses of the motor. While braking the induction of the motor is increased and therefore also the power losses of the motor. Technical description for MFR 600/1500 1

By means of a DIP-switch ( detailled description at 6.2 ) the drives can be switched to the following operation modes: In the Normal - operation the frequency range reachesup to 150 Hz. In the low speed range the motor voltage can be increased by the adjustment of trimpot Boost ( P1 ). The increase of the motor voltage causes at zero speed a DC-current in the motor. This DC-current provides braking down to zero speed and is automatically switched off 4 seconds after reaching zero frequency. This switch off is necessary to avoid heat-up of the motor at zero speed. In the Pump - operation - mode the maximum frequency reaches only 55 Hz and the ramp time is fix at 5 sec. The trimpotis Boost and Ramp are in this operation mode not active. In This mode the voltage to frequency - ratio is reduced with the frequency. This reduces the power - losses of the motor at reduced speeds. In the High - frequency - operation - mode the maximum frequency - range reaches up to 600 Hz. In this mode the trimpot boost is used to adjust the required voltage to frequency - ratio. In the operation - mode long ramp the ramp - time - adjustment - range is switched from 0.2-15 sec to 4-300 sec ( for a frequency - step of 150 Hz / 600 Hz ). This Mode is not combinable with the pump-operation mode. The operation - mode Motorpot enables to control the speed of the drive by 2 keys ( see 4.5 ). The operation - mode 200 Hz let the inverter automatically speed up to 200 Hz after switch on. The ramp-time is fixed to 1 sec, all control - signals and trimpotentiometers are inactive. The selection of the required operation - mode without voltage on the mains and inside the inverter. After disconnecting the drive from the mains the circuit needs appr. 30 sec to be free of voltage. After this time a switch from one to another operation - mode can be done. For the connections of the mains, motor and control lines there are plug - in - terminals used. To protect the drive against dust, humidity, mechanical shock and vibrations the electronic unit is embedded in a soft casting resin inside an aluminium case. The control - imputs of the drive are protection - isolated ( in accordance with VDE 0884 ). The drives are also protected against a direct short between motor - lines or between motor - line and earth. The electronic limiter of the motor - current allows at case temperatures up to 70 C a maximum motor - power of appr. 150 % of nominal power. The thermal - protection is switching off the drive at appr. 85 C. The reset of the thermal switch off must be done by switch off the mains for at least 10 sec. To control the drive signals from potentiometer, ext. voltage 0...10V, ext. current 0...20 ma or 4...20 ma are possible. The adaption of the input - circuit to correspond to the control - signal is made by the jumper B1 and B2. Attention! If the input - circuit is set for control from a potentiometer or with 0...10 V, a disconnection of the control - input ( terminal 2 ) causes a control signal of half the adjusted maximum! Open control - input is therefore to be avoided. To enable the drive a closed loop must be connected to the enable - input. The temperature protection circuit of the motor is designed to accept loops with up to 1040 ohm as closed loops, higher resistance values as open loops. This makes it possible to use a PTC - sensor or a thermistor in the motor. The drive delivers an output signal (Inverter OK) if mains is ok and no error is detected. Control - lines with a length of more than 2 meters must be shielded. The shield should be connected to terminal 4. Below the length of 2 meters shielding is recommanded if a high disturbance - level is present in the surrounding. Technical description for MFR 600/1500 2

2. Technical data MFR 600 A MFR 1500 A Mains - voltage 230 VAC 230 VAC With reduced load switchable to 115 VAC 115 VAC Tolerance of the mains-voltage +- 15% +- 15% Frequency of the mains-voltage 50-60 Hz 50-60 Hz recommanded fuse in the mains 6.3 A slow 10 A slow rec. max. motor size 375 W 750 W Nominal voltage of the motor 3 X 230 VAC 3 X 230 VAC Motor - current ( max. at 30 C case-temp.) >3 A RMS >5.5 A RMS Temperature - range ( case - temperature ) 0...70 C 0...70 C Mechanical size 150 X 100 X 70 mm 150 X 100 X 70 mm Weight 0.85 kg 0.88 kg Output - frequency - ranges: - Normal - operation 0...150 Hz - Pump - operation 0...55 Hz - High - frequency - operation 0...600 Hz Adjustment - range of the min. frequency (trimpot P4) 0...50% of the preadjusted maximum Ramp - times: Normal - operation, frequency - step = 150 Hz - DS 5 off 0.1... 15 sec - DS 5 on 4... 300 sec High - frequency - mode, frequency step = 600 Hz - DS 5 off 0.2... 15 sec - DS 5 on 1.5...250sec Pump - operation - mode, frequ. step = 55 Hz 7 sec 200 Hz - operation - mode 1 sec Control - signals: B1 and B2 open B1 closed, B2 open B1 and B2 closed Input - resistance of the control - input: B1 open B1 closed Enalble - signal: Reversing - signal: Temperatur protection input: Inverter OK output : Poetentiometer or ext. voltage 0...10 VDC 0... 20 ma DC 4... 20 ma DC > 500 kohm 470 ohm closed loop or +24V / 3-5 ma DC open / closed loop or +24V / 3-5 ma DC closed loop with R < 1040 ohm Loop current appr. 1 ma open collector NPN, max. load 27V DC / 100 ma Technical description for MFR 600/1500 3

3. Function of the ramp - generator: 3.1 Normal - or high - frequency - operation - mode: The adjustment of the ramp - time is made by trimpot P2. With DS 5 off the range of t is 0.1... 15 sec. ( for a frequ. step of 150 Hz resp. 600 Hz ) With DS 5 on the range of t is 1.5... 250sec. 3.2 In the mode pump - operation the ramp - time is fixed to 7 sec. ( for a frequ. step of 55 Hz ). 3.3 In the operation - mode 200 Hz the ramp time is fixed to 1 sec. 4. Electrical connection and examples for the control of the drive: 4.1 Control by potentiometer: set-point F D T OK U V W PE N L1 8 7 6 5 4 3 2 1 D = direction F = enable T = Motor-temp. OK = Inverter OK motor 3x230V L1 N PE mains 230 VAC Technical description for MFR 600/1500 4

4.2 Control by external voltage 0...10 V DC: F D T OK = + ext. control voltage 0...10V DC 8 7 6 5 4 3 2 1 D = direction F = enable T = Motor-temp. OK = Inverter OK 4.3 Control by external current 0...20 ma DC ( 4... 20 ma DC ): F D T OK = + ext. control current 0...20mA rsp. 4...20mA 8 7 6 5 4 3 2 1 D = direction F = enable T = Motor-temp. OK = Inverter OK 4.4 Control by 2 keys in the mode Motorpot : control keys F D T - key + key OK 8 7 6 5 4 3 2 1 D = direction F = enable T = Motor-temp. OK = Inverter OK Technical description for MFR 600/1500 5

5. Mechanical dimensions, assembling on the motor: ( Drawn is one possible assembling. In accordance to the requirements the drive can also be assembled in different modes ) Upper part with the inverter Sealing Lower part Motor Sealing Range for the cableterminations Assembling - steps: 1. Drilling and milling of the lower part of the case in accordance to the flange of the motor - terminal - case. Drilling the holes for the cable - terminations. Caution! Take care that the capacitors of the drive do not bump into the terminals of the motor! 2. Assembling of the lower part of the case on the motor. 3. Assembling of the cable - terminations. 4. Assembling and fastening of the cables. 5. Connecting of the plug-in - terminals to the wires of the cables and the motor. 6. Placing the seal. 7. Plug - in the connectors to the converter. 9. Fixing of the upper case on the lower case. Technical description for MFR 600/1500 6

6. Start of operation, adjustments: Because of the fact, that an adjustment is impossible if the drive is assembled, parameters and limits must be adjusted before assembling. It is recommanded to make the requ. adjustments within the incoming inspection. For OEM applications we offer as a special service without additional costs to make the adjustments within the final inspections in our house. 6.1 Position of the switches, jumpers and trimpots: LED status 1 2 3 4 5 6 P1 Boost P2 Ram N1 N2 P3 Max. B1 B2 P4 Min. 8 7 6 5 4 3 2 1 U V W PE N L1 6.2 Selection of the requ. operation - mode: DS1 DS2 Normal operation ON ON Pump operation OFF ON High frequency operation ON OFF 200 Hz operation OFF OFF Selection of the requ. Additional modes ( can be combined ): Control mode Motorpot Clock frequency 16 khz Long ramptime Inverter not self starting DS 3 ON DS 4 ON DS 5 ON DS 6 ON Selection of the control modes: Control by potentiometer or ext. Voltage 0 10V: Control by current 0 20 ma: Control by current 4 20 ma: B1 and B2 open B1 closed, B2 open B1 and B2 closed Technical description for MFR 600/1500 7

6.3 Adjustment of the trimpotis in the Normal - operation - mode: 6.31 Connect mains, motor and control - circuits. 6.32 Switch on mains, close the enable - loop. Turn set - point - potentiometer to the maximum CW. Adjust the requ. maximum speed at trimpot P3. 6.33 Turn set - point - potentiometer to the maximum CCW. Adjust the requ. minimum speed at trimpot P4. 6.34 Turn the set - point - potentiometer fast from CCW to CW and return. Adjust the requ. ramp time at trimpot P2. 6.35 If in the low - speed -range additional torque is necessary, adjust the boost - ratio at trimpot P1. 6.4 Adjustment of the trimpotis in the High - frequency - operation mode: The adjustment runs similar to 6.31-6.34. The requ. voltage to frequency - ratio must be adjusted at trimpot P1, the boost - function is inactive. 6.5 Adjustment of the trimpotis in the Pump - operation - mode: The adjustment runs similar to 6.31-6.33, steps 6.34 and 6.35 are inactive. After this adjustments the converter - unit can be assembled on the motor and operation can start. 7. Safety considerations The following safety considerations must be observed during all phases of operation, service and repair of this device. Failure to comply with this precautions violates the intended use of this device. To minimize the shock - hazard the drive must be connected to an electrical ground. Terminal PE or the metal-case must be connected to the electrical ground ( safety - ground ) of the power - outlet. Do not operate in an explosive atmosphere! Operation of this device in the presence of flammable gases, fumes or dusts may cause of an ignition of this atmosphere and is to prevent. CAUTION! To prevent potential shock hazards do not expose this device in the open state to moisture, rain or wetness. Wetness inside the case may cause an electrical connection between mains and the inputs. Installation, ajustment and service of this device must be made by qualified personal. Works at the electrical parts of the device are very dangerous because of the high voltage the device is working with. This high voltage is capable of causing death and is present even after disconnecting mains. Before starting of service it is necessary to wait at least 30 sec. after disconnecting mains. This device must not used as an electrical disconnection. It is not allowed to work at the output lines without a mechanical disconnection from mains, even if the driven motor does not carry voltage or current. Do not attempt internal service or adjustment unless another person, capable of disconnecting mains and rendering first aid is present. Do not touch the electrical parts of this device. During operation the electrical parts are carrying dangerous voltages. Out of operation a touch may cause a defect by electrostatic discharge. To prevent additional hazards, do not make modifications at this device. Technical description for MFR 600/1500 8