imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

Similar documents
AUDIO2-4 for imc CRONOSflex (CRFX/AUDIO2-4)

ICPU2-8 for imc CRONOSflex (CRFX/ICPU2-8)

LV3-8 for imc CRONOS-PL/-SL/compact

imc C-SERIES: CS-1016-N, CL-1032-N

imc C-SERIES: CS-3008-N, CL-3016-N

imc C-SERIES: CS-5008-FD

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Modular Smart Interfaces

SCXI 8-Channel Isolated Analog Input Modules

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Analog Isolation Amplifiers

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Transducer for Measurement Bridges SCM90, SIGS15

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

USB-2404-UI Specifications

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Process displays For standard signals, temperature, resistance measurement

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Q.raxx A101-8 slimline RS / EC

CAN-IO Custom IO remote module

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

DS10000ULFS-10V/10kA

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Assembly. Front view. Parametrization interface. Power Bus

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

S200 I/O System Units

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

VersaPoint I/O Module

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Model Channels Input type Sample rate Resolution

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Advanced Test Equipment Rentals ATEC (2832)

Specifications. PCI Bus. Analog Input Input Characteristics

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Q.raxx A slimline RS / EC

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

Kistler LabAmp for DynoWare

PFXLM4B01 D * * (1) (2) (3) (4)

Analog Isolation Amplifiers

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

Temperature head transmitter itemp PCP TMT 181

Components Signal Conditioning For Your Computer Instruments Standard Models

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Fluke Norma 4000/5000

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Analog Signal Conditioning Accessories

QUAD PROGRAMMABLE FILTER/AMPLIFIERS For the and Signal Conditioning Systems

8558A 8 1/2 Digit Multimeter

Isolators A3/1.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

MX1615. Data sheet. Bridge/strain gauge amplifier

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

CSM High-Voltage Measurement Systems

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

Uni-Mux XQL Multi-Channel Data Acquisition Module

High Performance Current Transducer ITL 900-T = A

Temperature Measurement

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Power Quality Analyzer Topas 2000

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

High-precision process calibrator Model CED7000

CONTA-ELECTRONICS. Converter Units

RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS FEATURES. 32-Channel Thermocouple Measurement System

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

QUAD-CHANNEL CONDITIONER BALANCED CURRENT EXCITATION ±10 V Common Mode; 255 or 510 Cutoff Frequencies

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

Temperature measurement TMD 832 head transmitter

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Transcription:

Data Sheet Version 1.9 imc CANSAS-L-HCI8 High isolated module for the capture of temperature, voltage, current (20 ma) and resistance The imc CANSAS module (CANSAS-L-HCI8) enable measurement of low voltage signals riding on a high or indeterminate common mode level of up to 800 V. Highlights: isolated measurement of low voltages, resistance, current and temperature (TE and Pt100) at a high common mode level 440 Hz bandwidth with max. 1 ksps/channel sampling rate Measurement and sampling rates can be imc CANSAS-L-HCI8-2T set per channel in steps of 1, 2, 5 16 bit resolution (with internal 24 bit processing) Supports imc Plug & Measure TEDS (Transducer Electronic Data Sheets, IEEE 1451.4) Support of TEDS for storing and exporting sensor information. Parameterization of a measurement channel at the click of a mouse. Typical applications: Measurements on high voltage battery or fuel cell terminals, e.g. Hybrid or Electric vehicles. General characteristics of imc CANSAS modules Operating conditions: extended temperature range, including humidity / condensation mechanically robust CAN interface: configurable baud rate up to 1 MBit/s galvanically isolated Synchronization: simultaneous sampling of all module's channels synchronizing of multiple imc CANSAS modules and with global CAN logger both via dedicated SYNC signal or based on CAN messages Power supply: galvanically isolated wide input voltage range supply via CAN cable possible automatic self start upon power-up Onboard signal processing: "virtual channels" integrated signal processor (DSP) for online processing: data reduction, filtering, scaling, statistics etc. programmable multi function status LED (front panel) Housing and Connectors: variety of different housings and connections 1

Software Configuration: with imc CANSAS Software (included) Supports the CANopen protocol according "CiA DS 301 V4.0.2" and "CiA DS 404V1.2"; 4 TPDO (Transmit Process Data Objects) in INT16, INT32, and FLOAT. The supported capabilities, more standards and the settings which can be edited via CANopen are described in the "CANSAS CANopen " documentation. Capable of automatic start upon power up with preloaded configuration; also available preconfigured ex-factory. The module's current configuration can be extracted and exported by the software; this makes it possible to transfer configurations made by others by means of just the module. The "-L" and "-K" models, when installed and operated in the 19" subrack backplane, can automatically identify their slot position within the rack and pass this information on to automation software. The module can send a CAN-Bus message at intervals ("heartbeat ). This periodic message can serve the purpose of monitoring whether the correct module is being used with the correct configuration. Measurement operation: simple measurement operation with imc CANSASpro using CAN interface such as imc CAN-USB or any other 3rd party PC CAN interface Data logger operation Software: imc STUDIO or imc DEVICES Hardware: imc measurement systems with CAN interface such as imc BUSDAQ, imc CRONOS series (CRC, CRFX, CRSL, CRPL), imc C-SERIES, imc SPARTAN any 3.rd party CAN data logger systems Overview of the available variants Order Code article number housing signal-plug CAN-plug CANSAS-L-HCI8 1050292 aluminum housing PHOENIX DSUB-9 CANSAS-L-HCI8-2T 1050343 aluminum housing thermo plug (female) type K for high voltages CANSAS-L-HCI4-2T 1050355 aluminum housing thermo plug (female) type K for high voltages DSUB-9 DSUB-9 imc CANSAS-L-HCI8-2T 2

Housing types Operating conditions for Alu profile and cassette Operating temperature: -30 C to 85 C condensation allowed Shock resistance 50 g pk over 5 ms Included accessories Calibration certificate as per DIN EN ISO 9001 Instruction manual (Getting started) Suitable power input plug: PHOENIX plugable terminal block (aluminum profile housing) Optional accessories Mounting brackets for fixed installations of CANSAS modules with Alu profile housing CAN/BRACKET-90 mounting bracket 90 (1050319) CAN/BRACKET-DIN-S mounting bracket for DIN-Rail (1050324) CAN/BRACKET-DIN-M mounting bracket for DIN-Rail (1050325) Mounting brackets for fixed installations of CANSAS-SL modules CAN/SL-BRACKET-CON interconnect bracket (1150048) CAN/SL-BRACKET-90 mounting bracket 90 (1150047) CAN/SL-BRACKET-180 mounting bracket 180 (1150049) 3

Technical Specs - HCI8 Data Sheet Version 1.9 Parameter Value Remarks Inputs HCI8 HCI4 Measurement modes PHOENIX spring clamp Measurement modes Thermo plug (-2T) Sampling rate/channel 8 4 Voltage Current Resistor Thermocouples, RTD (Pt100) Thermocouples type K 1 khz Bandwidth 440 Hz -3 db Filter cutoff frequency Filter characteristics Connection terminals inputs CAN (in / out) Supply isolated analog channels with high common mode voltage 1/6 of sampling rate digital low-pass, Butterworth and 5 terminals / channel (+IN, -IN, +I, +PT, -PT) PHOENIX FFKDS 3,81 spring clamp terminals 8x Thermo plug type K 4x Thermo plug type K 2x DSUB-9 PHOENIX (MC 1.5/4STF-3.81) Bessel, 2nd order CANSAS-L-HCI8 CANSAS-L-HCI8-2T CANSAS-L-HCI4-2T 4

Voltage and current measurement Parameter Value typ. min. / max. Remarks Voltage input 20 mv / 50 mv / 100 mv / 200 mv / 500 mv / 1 V / 2 V / 5 V / 10 V / 20 V / 60 V Current input Gain uncertainty <0.025 % Offset uncertainty <0.07 % 10 ma / 20 ma <0.05 % <0.15 % 0.02% 0.05% 0.08% 50 internal shunt voltage, 25 C current of range range > range 50 mv 50 mv Non-linearity <120 ppm 10 V input range Gain drift 15 ppm/k 50 ppm/k 2 V 5 V over entire temperature range Offsetdrift 1 µv/k over entire temperature range Input voltage noise (RTI) Channel isolation >1 G, <40 pf Crosstalk >1 G, <10 pf >165 db (50 Hz) >92 db (50 Hz) 2 µv rms bandwidth 0.1 to 440 Hz range 20 mv 12 µv pp R source = 0 to system ground chanel-to-channel 2 V 5 V R source 100 Temperature measurement - Thermocouples Input R, S, B, J, T, E, K, L, N per IEC 584 Resolution 0.025 K < 0.028 K dependent on type (16-bit) Measurement uncertainty < 0.5 K Type K, range: -150 C to 1200 C Temperature drift Uncertainty of cold junction compensation Drift of cold junction compensation 0.001 K/K T a 0.02 K/K T a T a = T a -25 C ambient temperature T a < 0.8 K T i = T i -25 C ambient temp T i Temperature measurement Pt100 Input -200 C to +850 C -50 C to +150 C Resolution Measurement uncertainty Temperature drift 0.016 K 0.003 K < 0.25 K < 0.05 % Sensor power supply (Pt100) 250 µa individual current sources, isolated input range: -200 to +850 C (16-bit) input range: -50 to +150 C (16-bit) -200 C to +850 C, four-wire measurement plus measurement value 0.01 K/K T a T a = T a -25 C ; ambient temp T a 5

Resistor measurement Parameter Value Remarks Input range 0 to 1000 0 to 500 0 to 250 0 to 150 General Parameter Value typ. min. / max. Remarks Isolation: (common mode) General Pollution degree test voltage to system ground Automotive Measurement category Working voltage transients, diff. overvoltage Supply network Measurement category Assessment voltage Overvoltage protection (differential) IMR (isolation mode rejection) Input coupling configuration Input impedance Input current normal at overload TEDS - Transducer Electronic Data Sheets CANopen mode 2 2300 V CAT I 800 V 500 V CAT II 300 V 600 V ESD 2 kv Transient protection: automotive load dump ISO 7637, test impulse 6 >105 db (50 Hz) 0.01 ppm/hz 40 db >70 db (50 Hz) 0.12 ppm/hz 18 db DC differential, isolated 6.7 M 1 M 50 1 na 1 ma conformant to IEEE 1451.4 Class II MMI "CiA DS 301 V4.0.2" and "CiA DS 404V1.2" per IEC (EN) 61010-1:2001 1 min impulses per ISO 7637-2 diff. input voltage, 1 min. human body model Test impulse 6 Ri=30, td=300 µs, tr<60 µs Ranges < 1 MHz 1 MHz Ranges < 1 MHz 1 MHz 2 V 5 V R source = 0 isolated from system ground (housing, CHASSIS, function ground) Ranges 2 V Ranges 5 V and with device deactivaed current input under operating conditions Vin > 5 V for < 5 V or deactivated special order only when equipped with custom connectors from CANSAS version 1.6R12 6

General Parameter Value typ. min. / max. Remarks supports 4 TPDOs in INT16, INT32, and FLOAT Supply voltage 10 V to 50 V DC common mode Power consumption 4 W < 5.5 W depending on supply voltage and operating mode Operating temperature -30 C to 85 C Dimensions (W x H x D) Weight 75 x 111 x 145 mm 790 g tested in this mounting orientation CANSAS-L-HCI8(-2T) CANSAS-L-HCI8 7