Current Probes. User Manual

Similar documents
Model Series. Current Probes MANUAL L L. ETS-Lindgren February 2005 Rev D PN

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Broadband Current Probe Series Operation Manual

Log Periodic Dipole Array Antenna

Bulk Current Injection Probe Test Procedure

Model 3104C. Biconical Antenna. User Manual

Broadband Current Probe Series Operation Manual

Model Biconical Antenna. User Manual

Current Probe Fixture Instruction Manual

Advanced Test Equipment Rentals ATEC (2832)

Model 3180B Mini-Bicon Antenna User Manual

Model BiConiLog Antenna. User Manual

Model Biconical Antenna. User Manual

Model 3140B BiConiLog Antenna User Manual

Double-Ridged Waveguide Horn Antennas

FISCHER CUSTOM COMMUNICATIONS, INC.

Model 3106 Double-Ridged Waveguide Horn

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Model Near-Field Probe Set. User Manual

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

Calibration Comparison System

Model 3116 Double-Ridged Waveguide Horn

Model 9305 Fast Preamplifier Operating and Service Manual

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

Advanced Test Equipment Rentals ATEC (2832)

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

Model 3110B Biconical Antenna

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

MODEL 3810/2 Line Impedance Stabilization Network

SAS-562B Active Loop Antenna Operation Manual

SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

Electromagnetic Compatibility

MG7095 Tunable S-Band Magnetron

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03

Agilent 1146A AC/DC Oscilloscope Current Probe

Trees, vegetation, buildings etc.

Model 113 Scintillation Preamplifier Operating and Service Manual

INSTRUCTION MANUAL. March 11, 2003, Revision 3

SAS-563B Active Loop Antenna Operation Manual

411LA Broadband Power Amplifier

AMP-13 OPERATOR S MANUAL

Flexible AC current probes

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

MG5223F S-Band Magnetron

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

A-E01D1. Austin E-Cap Series Isolation Transformer

Application Note (Revision NEW) Original Instructions. EMI Control in Electronic Governing Systems

Instruction Manual CT-6 High Frequency AC Current Probe

MS2030 CAT III 600 V A V AUTO RS232

CONTENTS MS2033A. 1.Introduction Safety Information...01

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Specification for Conducted Emission Test

CLA Series: Silicon Limiter Diodes Packaged and Bondable Chips

DM-46 Instruction Manual

ELECTROSURGICAL UNIT ANALYZER

Model 935A Current Source Operation Manual

MG MW S-Band Magnetron

AC/DC Current Oscilloscope Probe Model SL261

Model 863 Quad Timing Filter Amplifier Operating and Service Manual

10 Safety earthing/grounding does not help EMC at RF

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Keysight U9397A/C FET Solid State Switch (SPDT)

Current clamps for AC current

GaAs MMIC Non-Linear Transmission Line. Description Package Green Status

High Performance Current Transducer ITL 900-T = A

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Model 3148 & Log-Periodic Dipole Array Antenna

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

E2V Technologies MG5223F S-Band Magnetron

MG5193 Tunable S-Band Magnetron

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

M5028 Precision Tuned Magnetron

Model 9302 Amplifier-Discriminator Operating and Service Manual

400 MHz Passive High-Voltage Probe R&S RT-ZH

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

80i-110s AC/DC CURRENT PROBE

SPM-50 RF Spectrum Power Meter PC Software User Manual

VT1586A Rack Mount Terminal Panel Installation and User s Manual

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

mblc-10, mblw-10 Block Up Converter User Manual

esa Space Station Electromagnetic Emission and Susceptibility Requirements International Space Station Revision C May 31, 1996 SSP Revision C

DM-46 Instruction Manual

Digivance External Notch Filter Installation Instructions

High Current, High Power OPERATIONAL AMPLIFIER

R-X SERIES. Decade Resistor

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

RCTrms Technical Notes

201AP Charge Amplifier User Manual

Reducing Motor Drive Radiated Emissions

Model 7000 Low Noise Differential Preamplifier

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

Model 416A Gate and Delay Generator Operating and Service Manual

Active Monopole Antenna

Voltage Probe Manual and Data North Star High Voltage, Inc. Rev January 2016

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Transcription:

Current Probes User Manual

ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall constitute ETS-Lindgren Inc. assuming any liability whatsoever arising out of the application or use of any product or circuit described herein. ETS-Lindgren Inc. does not convey any license under its patent rights or the rights of others. Copyright 2008-2018 by ETS-Lindgren Inc. All Rights Reserved. No part of this document may be copied by any means without written permission from ETS-Lindgren Inc. Trademarks used in this document: The ETS-Lindgren logo is a trademark of ETS-Lindgren L.P. Revision Record MANUAL DESCRIPTION Part #399297, Rev. C Revision Description Date A Initial Release December, 2008 B Corrected spec for 91550-2 August, 2017 C Removed discontinued probes July, 2018 ii

Table of Contents Notes, Cautions, and Warnings... v 1.0 Introduction... 7 ETS-Lindgren Product Information Bulletin... 8 2.0 Maintenance... 9 Annual Calibration... 9 Service Procedures... 9 3.0 Specifications... 11 Model 91550-1 Current Probe... 11 Model 91550-1 Physical Specifications... 11 Model 91550-1 Electrical Specifications... 11 Model 91550-1 Pulse Power Limits... 12 Model 93686-8 Current Probe... 12 Model 93686-8 Physical Specifications... 12 Model 93686-8 Electrical Specifications... 12 Model 94111-1 Current Probe... 13 Model 94111-1 Physical Specifications... 13 Model 94111-1 Electrical Specifications... 14 Model 94111-1 Pulse Power Limits... 14 4.0 Principles of Operation... 15 Circuit... 15 Basic RF Transformer... 16 Sensitivity... 17 Model 91550-1 Typical Sensitivity... 17 Model 93686-8 Typical Sensitivity... 17 Model 94111-1 Typical Sensitivity... 18 Core Saturation and Intermodulation... 18 Transfer Impedance... 19 5.0 Assembly and Installation... 21 Equipment Setup to Measure RF Current... 21 For a Single Conductor... 21 For a Two-Conductor Cable... 21 For Multi-Conductor Cables... 21 iii

To Evaluate Shielding Effectiveness... 22 Installation Instructions... 22 Sample Test Configuration... 23 6.0 Operation... 25 Signal Measurement... 26 Signal Injection... 29 7.0 Typical Data... 31 Model 91550-1 Current Probe... 31 Model 91550-1 Transfer Impedance... 31 Model 93686-8 Current Probe... 32 Model 93686-8 Transfer Impedance... 32 Model 94111-1 Current Probe... 32 Model 94111-1 Transfer Impedance... 32 Appendix A: Warranty... 33 iv

Notes, Cautions, and Warnings Note: Denotes helpful information intended to provide tips for better use of the product. Caution: Denotes a hazard. Failure to follow instructions could result in minor personal injury and/or property damage. Included text gives proper procedures. Warning: Denotes a hazard. Failure to follow instructions could result in SEVERE personal injury and/or property damage. Included text gives proper procedures. See the ETS-Lindgren Product Information Bulletin for safety, regulatory, and other product marking information. v

This page intentionally left blank. vi

1.0 Introduction The ETS-Lindgren Current Probe is a clamp-on RF current transformer that determines the intensity of RF current present in an electrical conductor or group of conductors. The current probe is designed for use with electromagnetic interference (EMI) test receivers or spectrum analyzers, or with any similar instrument having a 50-ohm input impedance. Model 94111-1 Current Probe A current probe provides a way to accurately measure net (common mode) radio frequency current flowing on a wire or bundle of wires without requiring a direct connection to the conductor(s) of interest. The probe clamps around the test conductor which becomes a one turn primary winding; the probe forms the core and secondary winding of an RF transformer. Measurements can be made on single-conductor and multi-conductor cables, grounding and bonding straps, outer conductors of shielding conduits and coaxial cables, and so on. Introduction 7

This manual includes these ETS-Lindgren current probes: Model 91550-1 Model 93686-8 Model 94111-1 ETS-Lindgren Product Information Bulletin See the ETS-Lindgren Product Information Bulletin included with your shipment for the following: Warranty information Safety, regulatory, and other product marking information Steps to receive your shipment Steps to return a component for service ETS-Lindgren calibration service ETS-Lindgren contact information 8 Introduction

2.0 Maintenance Before performing any maintenance, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. WARRANTY Maintenance is limited to external components such as cables or connectors. If you have any questions concerning maintenance, contact ETS-Lindgren Customer Service. Annual Calibration See the Product Information Bulletin included with your shipment for information on ETS-Lindgren calibration services. Service Procedures For the steps to return a system or system component to ETS-Lindgren for service, see the Product Information Bulletin included with your shipment. Maintenance 9

This page intentionally left blank. 10 Maintenance

3.0 Specifications At the lower frequencies, the signal current IP level can be as great as allowed for maximum power current. When both signal and power currents are high, their sum should not exceed the given limits. L model current probes are calibrated down to 20 Hz. Model 91550-1 Current Probe MODEL 91550-1 PHYSICAL SPECIFICATIONS Window Diameter: Outside Diameter: Width: Output Connector: Weight: Impedance: 3.18 cm (1.25 in) 8.89 cm (3.5 in) 7.29 cm (2.87 in) Type N 0.6 kg (1.31 lb) 50 Ω MODEL 91550-1 ELECTRICAL SPECIFICATIONS Frequency Range : Transfer Impedance (Nominal): RF Current Range (RF CW): RF Current Range (Pulse): Maximum Power Current (DC 60 Hz): Maximum Power Current (400 Hz): 10 khz 100 MHz 5.0 Ω ± 3 db 1 MHz 100 MHz 42 amps 100 amps 350 amps 350 amps, 50 Hz 1500 Hz Specifications 11

Maximum Power Voltage: Internal Loading: Rated Output Load Impedance: Sensitivity Under Rated Load: No limitation; subject to adequate conductor insulation No 50 Ω 0.17 microampere with 1 microvolt sensitivity receiver and 6 ohm transfer impedance MODEL 91550-1 PULSE POWER LIMITS RF Current Range (Pulse): 100 amps Model 93686-8 Current Probe MODEL 93686-8 PHYSICAL SPECIFICATIONS Window Diameter: Outside Diameter: Width: Output Connector: Weight: Impedance: 6.65 cm (2.62 in) 13.97 cm (5.5 in) 5.38 cm (2.12 in) Type N 2.27 kg (5 lb) 50 Ω MODEL 93686-8 ELECTRICAL SPECIFICATIONS Frequency Range: Transfer Impedance (Nominal): RF Current Range (RF CW): RF Current Range (Pulse): 10 khz 200 MHz 8.0 Ω ± 3 db 10 MHz 200 MHz 0 amps 62 amps 62 amps 12 Specifications

Maximum Power Current (DC 60 Hz): Maximum Power Current (400 Hz): Maximum Power Voltage: Sensitivity Under Rated Load: Model Maximum Power Current (400 Hz): Maximum Power Voltage: Rated Output Load Impedance: Sensitivity Under Rated Load: 300 amps 300 amps No limitation; subject to adequate conductor insulation 0.125 microampere with 1 microvolt sensitivity receiver and 8 ohm transfer impedance 200 amps No limitation; subject to adequate conductor insulation 50 Ω 0.1 microampere with 1 microvolt sensitivity receiver and 10 ohm transfer impedance Model 94111-1 Current Probe MODEL 94111-1 PHYSICAL SPECIFICATIONS Window Diameter: Outside Diameter: Width: Output Connector: Weight: Impedance: 3.18 cm (1.25 in) 8.89 cm (3.5 in) 3.56 cm (1.4 in) Type N 0.42 kg (15 oz) 50 Ω Specifications 13

MODEL 94111-1 ELECTRICAL SPECIFICATIONS Frequency Range: Transfer Impedance (Nominal): 1 MHz 1000 MHz 0.9Ω(-1dB Ω) ±3dB @1 MHz 2.5Ω (8dB Ω) ±3dB @10 MHz 5Ω(14dB Ω) ±3dB @100 MHz 5.6Ω(15dB Ω) ± 3dB @500 MHz RF Current Range (RF CW): RF Current Range (Pulse): Maximum Power Current (DC 400 Hz): 20.0 amps 50 amps 200 amps Maximum Power Voltage: Sensitivity Under Rated Load: No limitation; subject to adequate conductor insulation 0.2 microampere with 1 microvolt sensitivity receiver and 5 ohms transfer impedance MODEL 94111-1 PULSE POWER LIMITS RF Current Range (Pulse): Maximum Power Current 50 amps for duty cycle less than 0.4 (DC to 1500 Hz) 300 amps When both signal and power currents are high, their sum should not exceed the given limits 14 Specifications

4.0 Principles of Operation Before connecting any components or operating the probe, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. The current probe is an inserted-primary type of radio frequency current transformer. When the probe is clamped over the conductor or cable in which current is to be measured, the conductor forms the primary winding. The clamp-on feature of this probe enables easy placement around any conductor or cable. Circuit The circuit is that of a radio frequency transformer, as illustrated on page 16. Because the current probe is intended for clamp-on operation, the primary shown on page 16 is the electrical conductor in which interference currents are to be measured. This primary is considered as one turn since it is assumed that the noise currents flow through the conductor and return to the source by way of a ground conductor such as a frame, common ground plane, or earth. On some current probe models the secondary output terminals are resistively loaded internally to provide substantially constant transfer impedance over a wide frequency range. Principles of Operation 15

BASIC RF TRANSFORMER 16 Principles of Operation

Sensitivity Probe sensitivity in microamperes depends on the sensitivity in microvolts of the receiving equipment with which it is used. The following tables show the relationship of receiving sensitivity in microvolts to the overall sensitivity of the probe and receiver in microamperes. This data is based on the transfer impedance of each model. MODEL 91550-1 TYPICAL SENSITIVITY Test Equipment Sensitivity in Microvolts 91550-1 ZT = 5.0 Ω 5 1 2 0.4 1 0.2 0.1 0.02 MODEL 93686-8 TYPICAL SENSITIVITY Test Equipment Sensitivity in Microvolts 93686-8 ZT = 8.0 Ω 4 0.5 2 0.25 1 0.125 0.1 0.0125 Principles of Operation 17

MODEL 94111-1 TYPICAL SENSITIVITY Test Equipment Sensitivity in Microvolts 94111-1 ZT = 5.0 Ω 5 1 2 0.4 1 0.2 0.1 0.02 Core Saturation and Intermodulation The magnetizing effects of a primary conductor carrying large currents at power line frequencies can saturate the current probe core material. Core saturation produces non-linear transforming action and can result in: A decrease in the current probe RF output for a given RF current input. Modulation of the RF output by the power line frequency. The specified pulse duty cycle should not be exceeded or the current probe internal load resistor (if applicable) may be subject to damage. The load resistor must also be protected from excessive line currents. The influence of intermodulation on the current probe output as measured with the EMI test equipment is negligible for primary conductor power frequency currents under 300 amperes. For primary power currents above 300 amperes, measurements taken by the EMI test equipment generally will not be affected by intermodulation due to the averaging characteristics for the quasi-peak and peak functions; the readings will increase with current. 18 Principles of Operation

Transfer Impedance The RF current (IP) in microamps in the conductor under test is determined from the reading of the current probe output in microvolts (ES) divided by the current probe transfer impedance (ZT). I E Z Or, in db: I dbµa E dbµv Z db The typical transfer impedance of the current probe throughout the frequency range is shown in Typical Data on page 31. It is determined by passing a known RF current (IP) through the primary test conductor and noting the voltage (ES), developed across a 50-ohm load. Z E I Principles of Operation 19

This page intentionally left blank. 20 Principles of Operation

5.0 Assembly and Installation Before connecting any components, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. Equipment Setup to Measure RF Current Standing waves can exist on the test conductor under test at or near the resonant frequency. Under these conditions, several measurements taken along the line will provide a complete picture of the RF current distribution and amplitude. FOR A SINGLE CONDUCTOR 1. Place the probe jaws around the conductor so that the conductor passes through the center opening. 2. Lock the jaws together. FOR A TWO-CONDUCTOR CABLE To evaluate the common mode component of the noise current (the net effect of the currents leaving and returning): Place the probe over both conductors at the same time. To measure the interference current in either conductor separately: Place the probe over each wire individually. FOR MULTI-CONDUCTOR CABLES The probe will measure the net external effects of all the currents in the conductors that pass through the center of the probe. Assembly and Installation 21

TO EVALUATE SHIELDING EFFECTIVENESS When placed over shielding conduit, coaxial cable, or ignition shielding, the probe measures the current flowing on the external surface of the shield. Installation Instructions The window (aperture) of the probe will accommodate cables up to the following maximum outside diameters. Current Probe Maximum Outside Diameter Model 91550-1 1.25 inches Model 94111-1 1.25 inches Model 93686-8 2.62 inches For greatest accuracy, the conductor under measurement should be centered in the window of the current probe. Place the probe around the conductor(s) to be measured and then carefully lock the probe jaws. Otherwise, inadequate shielding or incorrect air gap will result and the measurement will not be accurate. The connecting cable used between the current probe and the EMI test equipment must have 50-ohm characteristic impedance and matching cable connectors. The current probe is calibrated for use only with a 50-ohm load. Therefore, the EMI test equipment must have a 50-ohm input impedance. Observe precautions regarding minimum bending radius when installing and using the cable. For long cables and at high frequencies, cable loss may also be a factor. Use low loss cables and perform cable loss corrections if necessary. The probe rejection of any external pickup from conductors not passing through the window is better than 60 db. The presence of very strong magnetic fields will likely have an effect on probe sensitivity. Do not place the unit close to permanent magnets or the magnetic field structures of motors or generators. 22 Assembly and Installation

Sample Test Configuration Assembly and Installation 23

This page intentionally left blank. 24 Assembly and Installation

6.0 Operation Before connecting any components, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. If measuring uninsulated conductors: Use extreme care when installing the current probe and taking measurements. If possible, de-energize the test sample during assembly and disassembly of the setup. Also, arrange to center the test conductor in the current probe window for additional voltage breakdown protection. Do not permit the uninsulated current probe connector and cable connectors to come in contact with the ground plane or other nearby conductors. This will prevent possible measurement error due to ground loops, and will avoid danger from high voltages. Ensure that the 50-ohm load is capable of safely dissipating the incurred power. Should the load become disconnected, the developed voltage will be come much greater and may be very dangerous. The RF current probe is a broadband RF transformer for use with EMI test equipment. Radio frequency currents can be measured in cables without physically disturbing the circuit. Operation 25

Signal Measurement OSCILLOSCOPE USE: IN TERMS OF RF AMPERES 1. Standardize the gain of the oscilloscope to correctly read the voltage (ES) applied to the input terminals. 2. Divide ES in volts by the average current probe transfer impedance ZT in ohms. The result is the value of the RF signal in terms of amperes in the test conductor. Example: Assume an oscilloscope peak voltage measurement of 5 volts and the average ZT to be 1.06 ohms. Then: 5/1.06 = 4.71 amperes in the test conductor. The example is valid providing that the oscilloscope rise time (T = 0.3/BW) is shorter than RF signal pulse duration. This also applies to the current probe which has a rise time of about 3 nanoseconds based on a 100 megahertz bandwidth. IN TERMS OF db ABOVE ONE MICROAMPERE AT METER INPUT (CW CONDUCTED MEASUREMENTS) 1. Adjust the EMI test equipment for standard gain and make a measurement of the CW signal (voltage output from the current probe) in terms of db above one microvolt. Use procedures outlined in the EMI test equipment instruction manual. 2. Subtract the transfer impedance of the current probe in db at the test frequency from the db measurement of the previous step. The result is the value of the conducted CW signal in terms of db above one microamp at meter input. At meter input as used in the MIL-I-26600 and MIL-I-6181D specifications refers to the current in the test sample lead. 26 Operation

Example: Frequency is 10.0 khz; step 1 measurement is 52 db above one microvolt. For example, suppose the transfer impedance of the current probe used in the example was 8.0 db below one ohm at 10.0 khz. Then, as outlined in step 2: 52 db + 8.0 db = 60 db above one microampere at meter input. IN TERMS OF db ABOVE ONE MICROAMPERE PER MEGAHERTZ AT METER INPUT (BROADBAND INTERFERENCE MEASUREMENT) 1. Adjust the EMI test equipment for standard gain and make a peak measurement of the broadband interference (voltage output from the current probe) in terms of db above one microvolt per megahertz. Use procedures outlined in the EMI test equipment instruction manual. 2. Subtract the transfer impedance of the current probe in db at the test frequency from the db measurement of the previous step. The result is the value of the broadband interference in terms of db above one microamp per megahertz at meter input. At meter input as used in the MIL-I-26600 and MIL-I-6181D specifications refers to the current in the test sample lead. Example: Frequency is 100 khz; step 1 measurement is 41 db above one microvolt per megahertz. For example, suppose the transfer impedance of the current probe was 8.0 db below one ohm at 100 khz. Then, as outlined in step 2: 41 db + 8.0 db = 49 db above one microamp per megahertz at meter input. This result is beyond the limit of 46.2 db above one microamp per megahertz. Operation 27

IN TERMS OF MICROAMPERE IN TEST SAMPLE LEAD (CW CONDUCTED MEASUREMENTS) 1. Adjust the EMI test equipment for standard gain and make a measurement of the CW signal (voltage output from current probe) in terms of microvolts at meter input. Use procedures outlined in the EMI test equipment instruction manual. 2. Divide the microvolt measurement of the previous step by the transfer impedance in ohms at the test frequency. The result is the value of conducted CW signal in terms of microamperes in the test sample lead. Example: Frequency is 3.0 khz; step 1 measurement is 150 microvolts. For example, suppose the transfer impedance of the current probe was 0.34 ohms. Then, as outlined in step 2, 150/0.34 = 441.1 microamperes in the test sample lead. IN TERMS OF MICROAMPERE PER MEGAHERTZ IN TEST SAMPLE LEAD (BROADBAND INTERFERENCE MEASUREMENT) 1. Adjust the EMI test equipment for standard gain and make a measurement of the broadband interference (voltage output from current probe), in terms of microvolts per megahertz at meter input. Use procedures outlined in the EMI test equipment instruction manual. 2. Divide the microvolt per megahertz measurement of the previous step by the transfer impedance in ohms at the test frequency. The result is the value of conducted broadband interference in terms of microamps per megahertz in the test sample lead. Example: Frequency is 10.0 khz; step 1 measurement is 8000 microvolts per megahertz. For example, suppose the transfer impedance of the current probe was 0.39 ohms. Then, as outlined in step 2, 8000/0.39 = 20513 microamps per megahertz in test sample lead. 28 Operation

Signal Injection Applies to Model 94111-1 only. Current probes may be used to inject RF currents into test conductors when performing susceptibility tests. Injection is best accomplished with current probes that do not have internal loading. Internal loading will absorb part (or most) of the driving power and can seriously limit the maximum levels of voltage and current that the current probe can handle as an injection device. The current probe does not have an internal load and therefore is suited for signal injection. However, it will be limited by connector voltage rating (500 V) and by the thermal limit of the coil windings. A maximum continuous injection current into the current probe coils of 4.2 amps may be used; two or three times this level may be used for short periods of time. When injecting pulse signals, the average current should be held within the above limits, and the peak voltage held below 500 V. Because of variable circuit impedances, there is no easy way to compute the RF current that may be injected into the test conductor. The practical way to determine the injected current is to measure it with a second current probe on the test conductor. The second current probe can be any model that covers the frequency range of interest. Operation 29

This page intentionally left blank. 30 Operation

7.0 Typical Data Model 91550-1 Current Probe MODEL 91550-1 TRANSFER IMPEDANCE Typical Data 31

Model 93686-8 Current Probe MODEL 93686-8 TRANSFER IMPEDANCE Model 94111-1 Current Probe MODEL 94111-1 TRANSFER IMPEDANCE 32 Typical Data

Appendix A: Warranty See the Product Information Bulletin included with your shipment for the complete ETS-Lindgren warranty. DURATION OF WARRANTIES All product warranties, except the warranty of title, and all remedies for warranty failures are limited to two years. Product Warranted Model 91550-1 Current Probe Model 93686-8 Current Probe Model 94111-1 Current Probe Duration of Warranty Period 2 Years 2 Years 2 Years Warranty 33