FAQs. Not directly. The pe-100 Control Pod does have a BNC connector to allow for TTL triggering.

Similar documents
User Manual. pe-2. LED Excitation for Fluorescence. DOC-010 Iss 5 1

TouchBright Ver. 7.51

High Intensity LumiBright LE LED Light Engine

Exp. No. 13 Measuring the runtime of light in the fiber

Description of options, upgrades and accessories for the laser beam stabilization system Compact

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Cobolt Optogenetics Laser Solution

APE Autocorrelator Product Family

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

11Beamage-3. CMOS Beam Profiling Cameras

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Microscope-Spectrometer

FiberLight D2 Portfolio UV-Vis Light Source for high measurement consistency

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Single Frequency Laser/Single Longitudinal Mode Laser

LRS-0532-PF SERIES INFORMATION SHEET

LumaSpec 800S User Manual

Oriel MS260i TM 1/4 m Imaging Spectrograph

FiberLight Miniature UV-Vis Light Source for Mobile Spectroscopy and Online Process Control

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

Cobolt Optogenetics Laser Solutions

Cobolt Optogenetics Laser Solutions

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

Power. Warranty. 30 <1.5 <3% Near TEM ~4.0 one year. 50 <1.5 <5% Near TEM ~4.0 one year

Operating longitudinal mode Several Polarization ratio > 100:1. Power. Warranty. 30 <1.5 <5% Near TEM ~4.0 one year

Table 8 Overview light sources

pulsecheck The Modular Autocorrelator

AvaLight-DHc Full-range Compact Light Source

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

400 MHz Photoreceiver with Si PIN Photodiode

Solea. Supercontinuum Laser. Applications

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

Genesis CX STM-Series

200 MHz Photoreceiver with Si PIN Photodiode

Compact High Intensity Light Source

Spotlight 150 and 200 FT-IR Microscopy Systems

ModBox - Spectral Broadening Unit

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

High Performance Thin Film Optical Coatings Technical Reference Document 09/13. Coatings Capabilities. Heat Control - Hot Mirror Filters

Machine Vision Lyte-MV 2

10 Things to Consider when Acquiring a Nanopositioning System

P-736 PInano Z Microscope Scanner for Microtiter Plates

UV LED ILLUMINATION STEPPER OFFERS HIGH PERFORMANCE AND LOW COST OF OWNERSHIP

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

WORLD LEADING PRODUCTS FOR LASER SCIENTISTS AND ENGINEERS

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

Things to check before start-up.

Light Sources. Tip. Light Sources

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

Information & Instructions

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

Lab Junior Educational UV-VIS Spectrometer

OPERATING INSTRUCTIONS

MS260i 1/4 M IMAGING SPECTROGRAPHS

Integrated Diode Laser System DioPower

User-configured for Maximum Flexibility

THE ULTIMATE DOCUMENT EXAMINATION SYSTEM STATE-OF-THE-ART SPECTRAL ANALYSIS FORENSIC LABS SECURITY PRINTERS IMMIGRATION AUTHORITIES

intelliweld smart welding

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

Wavelength Meter Sensitive and compact wavemeter with a large spectral range for high speed measurements of pulsed and continuous lasers.

Nmark AGV-HPO. High Accuracy, Open Frame, Thermally Stable Galvo Scanner. Highest accuracy scanner available attains singledigit,

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

A Ray of Light. Fluorescence Light Sources. Fluorescence Illumination Mercury, Xenon and LED

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

Model Number Guide. M= Material. S= Apperture Size. P= Options

We bring quality to light. MAS 40 Mini-Array Spectrometer

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Where Image Quality Begins

1.2 BeamTrack Power / Position / Size Sensors

TURNKEY, ULTRA STABLE, OEM LASER DIODE SOURCE OZ-1000 & OZ-2000 SERIES

UV COBRA Slim Supplementary information

Instruction Manual RT-93285SL RR-93285SL Thirty-two Channel Video Multiplexer With Two Bi-directional Data Channels

Optional AR coating and wedge windows are available

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

The absorption of the light may be intrinsic or extrinsic

AvaLight-HAL-S-MINI Tungsten-Halogen Light Source

Fabry Perot Resonator (CA-1140)

Detailed Scientific Barrier Filter Discussion

INDIAN INSTITUTE OF TECHNOLOGY-KANPUR (DEPARTMENT OF MECHANICAL ENGINEERING)

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Power Sensors Introduction

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING

Tunable KiloArc. Tunable Broadband Light Source.

FIBER OUTPUT LIGHT SOURCE for ANALYSIS and EXPERIMENT

Automated Double Aperture Accessory

Zeiss 880 Training Notes Zen 2.3

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

idonus UV-LED exposure system for photolithography

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Quick Start Guide. Leica SP5 X

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

Zeiss 780 Training Notes

Installing the detector filter assembly (G )

WITec Alpha 300R Quick Operation Summary October 2018

Fiber Coupled Single Bar Diode Laser (CW)

Guide to SPEX Optical Spectrometer

HORTICULTURAL COB LEDs

Installation and Operation Manual Document Number 000-specc

Transcription:

pe-100 FAQs Can it be controlled through software? Not directly. The pe-100 Control Pod does have a BNC connector to allow for TTL triggering. What are the combination options? There is currently a choice of 20 different LED wavelengths ranging from 365nm to 770nm. Is there a fiber/llg version? The pe-100 is available as a liquid light guide version. This is fitted with a 3mm diameter light guide which is available in a variety of lengths. Also available as a fiber version. This accepts an SMA connector and can be ordered with a choice of SMA or cleaved end output. Fibers can be ordered in a variety of core diameters, numerical apertures and lengths. pe-300 white How many LEDs are inside? There are three arrays of LEDs in the pe-300 white. A choice of UV or Violet, as well as Blue and GYR (green to red excitation light). Can you control or trigger each channel? Yes, the system is fitted with a single BNC for TTL triggering. This will trigger any wavelength that has been selected using the control pod. DOC-029 Iss 1 1

Is it software controllable? The pe-300 white can be operated under the most popular imaging software packages. See the CoolLED website for a comprehensive list. Imaging Software - CoolLED Is it okay for FISH applications? The pe-300 white is suitable for many FISH applications. This depends on whether well suited filter sets are used in conjunction with the Light Source. Is there a fiber/llg version? The pe-300 white is available as a light guide version. This allows a 3mm core liquid light guide to be fitted, which is available in a variety of lengths. Is there intensity loss in the light guide? The specifications of the light guide states that between 400-700nm roughly 75% of the light entering the light guide is transmitted through. This percentage is lower in the UV and IR wavelengths, but still greater than 60% transmission. If comparing the direct fit to the light guide version however, you can expect the light guide version to deliver roughly half of the power of the direct fit. What does SB/MB stand for? SB and MB stand for single band and multi-band. This refers to the filter sets that are fitted in the microscope. This choice is necessary as DAPI can be excited at either 365nm or 400nm and microscopes typically have a filter set which allows one of these wavelengths to be transmitted. A microscope which is populated with a number of single band (SB) filter sets will typically have DAPI excitation at 365nm and a microscope with a multi-band (MB) filter has excitation at 400nm. The user can specify the configuration which is appropriate for their microscope. pe-2 Can all channels be used simultaneously? Wavelengths greater than and including 595nm cannot be used in simultaneous mode. All other channels can be used in simultaneous mode. Is there intensity loss in the light guide? The specifications of the light guide states that between 400-700nm roughly 75% of the light entering the light guide is transmitted through. This percentage is lower in the UV and IR wavelengths, but still greater than 60% transmission. DOC-029 Iss 1 2

Can it be controlled by Imaging Software? The pe-2 is recognized and able to be controlled by most common imaging software packages (such as µmanager, CellSens, NIS Elements, MetaMorph etc.). See the CoolLED website for further details- Imaging Software - CoolLED. Is the GYR better than individual LAMs? The GYR delivers roughly twice the power output of a single dedicated LAM in the green region. This is illustrated in the graph. Please note that the GYR LAM will take up two of the four positions in a pe-2 system. Can the pe-1 be upgraded to pe-2? Yes. Please contact CoolLED s support team (support@coolled.com) about upgrading a system. They will provide further details about this process. What does analogue control mean? The analogue function is no longer an available option for the pe-2 system. How fast can wavelengths be changed? When using TTL control, a switching time of 300 microseconds is achieved. When controlling through the USB, a switching time of <10 milliseconds can be achieved. DOC-029 Iss 1 3

pe-4000 Have I really got 15/16 wavelengths installed? Yes, there are 16 selectable wavelengths (15 installed LAMs). These are installed as standard. Can you use all wavelengths simultaneously? You can have up to four wavelengths switched on simultaneously at any time. One from each of the four channels. This is shown below in the wavelength grouping concept diagram. DOC-029 Iss 1 4

Can it be controlled by Imaging Software? The pe-4000 can be controlled by most common imaging software. The majority of these providers have now fully integrated the pe-4000 to allow all functions to be controlled in software. Some of these providers have not fully integrated the pe-4000. In which case the system will be viewed as a pe-2 by the software and only allow limited functions. Please view the CoolLED website for further information Imaging Software - CoolLED. Is there a focus problem with all wavelengths using the same light guide/fiber? No, there should be no issue focusing the light output from a fiber or light guide between wavelengths. Is the light guide/fiber damaged by certain wavelengths? The use of certain wavelengths (particularly UV & IR) can decrease the lifetime of the light guide. This is not by a significant amount however, in comparison to a metal halide system due to some of the advantages of LED systems: No warm up time (the light won t be transmitting through the light guide for as long of a period). Independent wavelength selection (only the spectral region(s) of interest will be transmitted through the light guide, eliminating any additional wavelengths that may potentially be damaging). Can you change/alter LAMs inside the pe-4000? LAMs inside the pe-4000 cannot be altered or changed. Due to the large choice of wavelengths that cover from the UV to the IR part of the spectrum, the pe-4000 should be suited to most typical filter sets as standard. Can a single trigger sequentially trigger channel 1,2,3,4? This cannot presently be done with a single trigger, but a sequence can be setup in software to cycle through the channels in this way. What does analogue control mean? Analogue control is a mode on the pe-4000 that allows a selected wavelength to be controlled by a voltage of 0-10V that is applied to the corresponding analogue input pin of the 25 way D-type connector. A voltage of 0-10V relates to an intensity of 0-100% intensity of the selected wavelength. For example, if a voltage of 6.2V is applied to a corresponding analogue input pin of a wavelength set to analogue mode, then the wavelength will be set to 62% intensity. DOC-029 Iss 1 5

Can you put excitation filters in front of all of the LEDs in the pe-4000? Excitation filter holders that accept 25mm filters can be added to the pe-4000. Four filters can be added to the system at any one time (one in the optical path of each of the four channels). How easy is it to put in filters? Fitting excitation filters into the pe-4000 is a straight forward process. A side panel needs to be removed (held in place by two catches) to gain access to the slots. Filters then fit in to the filter holder slides (not supplied as standard) and easily push into the correct position. Arrows are displayed next to the filter slots to indicate the direction of light. How quickly can the LEDs change in the same channel (e.g. 365 & 385nm)? Wavelengths on the same channel can be moved between in <2 seconds. Does the system get hot? The system should not get externally hot. As long as sufficient space of at least 200mm is allowed either side of the Light Source then the system shall be able to effectively cool itself. Is the system noisy? There is noise from the cooling fans intermittently to stabilize the Light Source temperature and from the stepper motors during initialization and when changing wavelength. DOC-029 Iss 1 6