Coherent Laser Measurement and Control Beam Diagnostics

Similar documents
Beam Diagnostics Introduction

3.4 Introduction to Scanning-Slit Profilers

3.4 Introduction to Scanning-Slit Profilers

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Beam Analysis NanoScan 2. Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement. Capabilities.

NanoScan 2s Standard Version Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement

OBIS CellX. The Universal Light Engine FEATURES

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder.

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc.

CUBE. Diode Laser System FEATURES

CUBE. Diode Laser System FEATURES & BENEFITS

Power. Warranty. 30 <1.5 <3% Near TEM ~4.0 one year. 50 <1.5 <5% Near TEM ~4.0 one year

Operating longitudinal mode Several Polarization ratio > 100:1. Power. Warranty. 30 <1.5 <5% Near TEM ~4.0 one year

Genesis CX STM-Series

Information & Instructions

Laser Beam Analysis Using Image Processing

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

Power Sensors Introduction

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

White Paper: Modifying Laser Beams No Way Around It, So Here s How

Description of options, upgrades and accessories for the laser beam stabilization system Compact

DPSS 266nm Deep UV Laser Module

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

ADVANCED OPTICS LAB -ECEN 5606

11Beamage-3. CMOS Beam Profiling Cameras

ignis TECHNICAL DATA SHEET high specification red laser CW 660nm laser Extremely low noise Power 500mW

DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner

Single Slit Diffraction

Test procedures Page: 1 of 5

OBIS CORE LS. Next Generation Miniaturized OEM Laser Module FEATURES

Properties of Structured Light

User s Guide Modulator Alignment Procedure

Nmark AGV-HPO. High Accuracy, Open Frame, Thermally Stable Galvo Scanner. Highest accuracy scanner available attains singledigit,

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

FIBER EVO. Miniaturized laser module complete with controller and USB power supply all within an incredibly small package

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Sapphire LP. CW Visible Lasers from Deep Blue to Orange. Superior Reliability & Performance. Sapphire LP Features:

Design Description Document

Lasers for Life Sciences

Radial Polarization Converter With LC Driver USER MANUAL

Autotracker III. Applications...

gem TECHNICAL DATA SHEET CW 532nm laser Extremely low noise Power from 50mW - 750mW 532nm high spec OEM laser

User s Guide Modulator Alignment Procedure

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

FireFly Green. It is a self-contained laser that offers the user increased stability over a wide operating temperature and with a faster warm up time.

Be aware that there is no universal notation for the various quantities.

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

Laser Telemetric System (Metrology)

OPERATING MANUAL. 100 MHz CENTER FREQUENCY OFF AXIS ACOUSTO-OPTIC BEAM DEFLECTOR MODEL NUMBER: DEG-.51 DOCUMENT NUMBER: 51A12229A

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

APPLICATION NOTE. Computer Controlled Variable Attenuator for Lasers. Technology and Applications Center Newport Corporation

Angular Drift of CrystalTech (1064nm, 80MHz) AOMs due to Thermal Transients. Alex Piggott

Aurora II Integra OPO Integrated Nd:YAG Pumped Type II BBO OPO

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

9. Microwaves. 9.1 Introduction. Safety consideration

Nmark AGV-HP(O) High Accuracy, Thermally Stable Galvo Scanner

Polarization Experiments Using Jones Calculus

Nmark AGV-HP(O) High Accuracy, Thermally Stable Galvo Scanner

Kit for building your own THz Time-Domain Spectrometer

User s Guide Modulator Alignment Procedure

Experimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza

Actively Stabilized Scanning Single Frequency. Ti:Sa /Dye Ring Laser

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner

The Beam Characteristics of High Power Diode Laser Stack

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Single Frequency DPSS Lasers

BLUE SKY RESEARCH BLUE

Fiber Optic Communications

1.2 BeamTrack Power / Position / Size Sensors

iflex-iris Laser Systems Product features include:

arxiv:physics/ v1 [physics.optics] 12 May 2006

Instructions LASNIX Polarization Sensors Models 601, 605, option H

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

DataRay Software. Feature Highlights. Beam Profiling Camera Based WinCamDTM Series. Software Aperture/ISO measurements

EUV Plasma Source with IR Power Recycling

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

Premier & Acculase Range Modular Modulatable Lasers

4GHz / 6GHz Radiation Measurement System

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Vixar High Power Array Technology

OPTI 511L Fall (Part 1 of 2)

BeamPro 3.0 Series User Manual Revision WARRANTY

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

Model Number Guide. M= Material. S= Apperture Size. P= Options

Commissioning of Thomson Scattering on the Pegasus Toroidal Experiment

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

High Power and Energy Femtosecond Lasers

Laser Measurement and Control

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

LTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2

Transcription:

Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination of waist location and diameters (including D4σ diameter) and Rayleigh Range Angular and translational beam-pointing stability Coherent pioneered M 2 beam propagation analysis with the ModeMaster system a decade ago. Now, Coherent introduces the ModeMaster PC, the newest version of the ModeMaster line of M 2 Laser Propagation Analyzers. The combines all the ISO-compliant accuracy and powerful features for measuring M 2 and other beam propagation analysis functions for CW lasers. It also provides the added flexibility and value of using a personal computer to provide optimum user control, data processing, storage and results display. The includes a Universal Serial Bus (USB) Control/Interface Console and Windows software for operation with the latest MS Windows-based PC computers supporting a USB interface (for MS Windows 98, ME, 2000 or XP). The is also compatible with all existing ModeMaster systems, allowing current users to easily upgrade their system for use on a supported PC computer. Easy Alignment The precision 5-axis head mount and beam position display provides easy angular alignment and translational centering of the lens and scan axis to the beam propagation path. Propagation Display Second Moment Diameters diameter is a critical parameter in beam propagation measurements. Second moment diameters (D4σ) give the best theoretical answers for beam propagation calculations. The measures second moment diameters directly. The software also includes conversion algorithms from its knife-edge measurements to second moment diameter measurements that are valid for stable resonator modes with M 2 of 1 to 4 (covering most commercially available lasers). Also included are conversions to D86 and slit diameters to allow comparison to other measurements. Real-Time Density Adjustment In most laser applications, it s not laser power that does the work, it s power density. Using the, the point of maximum power density can be quickly located. The s convenient power density tuning screen displays power density as a pseudo analog tune bar, giving real-time feedback as the laser mirrors are adjusted. 77

Coherent Laser Measurement and Control Real-Time Display Pointing Stability Display Real-Time M 2 and Profiles The provides real-time measurement and display for fine tuning of M 2 and many other beam propagation parameters, along with the near-field or far-field pinhole intensity beam profiles. Pointing and Translational Stability ModeMaster is able to measure and display both translational (parallel to the beam axis) or angular (from a pivot point) beam movement over a period of 2 minutes to 24 hours. The angular pivot point of the beam axis (often a single optical surface) can be located along the beam path. Statistical analysis of the beam axis location and angle are displayed for both the X and Y axes. Three levels of filtering reduce noise and increase the sensitivity of pointing stability measurements. Expanded On-line Help The provides complete on-line help. Help messages are also displayed when beam parameter limits are exceeded and messages suggest corrective measures. Upgrading to the All previous versions of the ModeMaster systems can be upgraded to the by replacing the original console unit and the LabMaster display with the ModeMaster PC Control/Interface Module and Software installed in a usersupplied compatible PC computer (see requirements below). All original ModeMaster Scan Heads are fully compatible and can be plugged into the Control/Interface Module, which can be ordered separately and includes the software. RS-232 Interface The can provide measured beam data, analysis results and focus scan control through the RS-232 interface for remote data logging, results monitoring and measurement control. Minimum Computer Requirements MS Windows 98, ME, 2000 or XP USB port available Laptop or desktop PC with 586 (Pentium II) 233 MHz processor or better 64-Mb of RAM 30-Mb of free hard disk space SVGA graphics card and display (800 x 600 recommended) Serial communication port (for remote operation) Astigmatism and Asymmetry Changes in shape of a propagating beam can be astigmatic, asymmetric or both. The beam shown at the near right has pure astigmatism; the waists (W0) in the horizontal and vertical directions are the same size, but occur at different propagation distances (Z0). In asymmetric beams (far right), the two waists occur together, but are of different diameters. The provides complete analysis of these beam characteristics. Pure Astigmatism Z ox Z oy W ox = W oy Pure Asymmetry Z ox = Z oy W ox W oy 78

Coherent Laser Measurement and Control Complete Geometric Characterization Along the Laser Path Rotating Drum Sensor propagation is concerned with the energy distribution in a beam and the change of that distribution along the beam path. The ModeMaster Propagation Analyzer established an entirely new laser beam quality parameter, M 2, which has now become an ISO measurement standard. M 2 describes how close to perfect-gaussian a laser beam is, and it can be used to predict the beam size, beam shape and the smallest spot that can be created from the beam further down range. How Does It Work? The head is a dual knife-edge beam profiler integrated with a diffraction-limited precision scanning lens, which is translated along the beam propagation axis. The lens focuses the beam to create an internal beam waist and the two orthogonal knife edges (X and Y), mounted on a rotating drum, measure the beam diameter and beam axis location at 256 planes along the beam waist as the lens is translated. The powerful software then derives the M 2 factor, the size and location of the beam waist, the far-field divergence angle, the pointing direction, astigmatism, asymmetry and the Rayleigh Range. Measurements also include ISO D4σ, second moment, knifeedge, slit and D86 beam diameters. This entire process occurs in less than 30 seconds. Servo- Driven Lens Quality M 2 Diameter Waist Diameter & Location Angle Rayleigh Range Pointing Stability Density Knife- Edges Pinholes The also provides special weighting functions to help eliminate effects on measurement accuracy due to intermittent beam noise, vignetting or other transients during the focus scan. Additionally, real-time displays allow laser peaking or adjustment for minimum M 2, divergence, maximum power density, far-field pinhole profiles and pointing angle. Profiles Second Moment Diameters Astigmatism Waist Asymmetry Asymmetry Laser Quality The closer a real laser beam is to diffraction-limited, the more tightly it can be focused, the greater the depth of field, and the smaller the diameter of beam-handling optics needed to Real Z Normalizing Gaussian transmit the beam. M 2 is the ratio of the divergence of the real beam to that of a theoretical diffraction-limited beam of the θ Θ Z same waist size in the TEM oo mode. Thus, the angular size of the beam in the far field will be M 2 larger than calculated for a perfect Gaussian beam. 2W M 2 = Θ θ Θ = M 2 x 2λ / (πwo), for a beam waist diameter 2Wo. www.coherent.com 1 LMC.sales@coherent.com (971) 327-2700 79

Coherent Laser Measurement and Control Selecting a System Configuration The systems are available in eight standard configurations (including scanning head, 5-axis mount, USB Control/Interface Console, cables, PC software and manual). These configurations provide measurements in four wavelength ranges, with two divergence ranges (high divergence and low divergence) within each wavelength range. Use the following steps, along with the Nomogram Chart and Configuration Table (below), to select a configuration. 1 2 3 4 5 Choose between the four spectral ranges: UV (220-680 nm), VIS (340-1,000 nm), N (800-1,800 nm) and (1,800-15,000 nm). Determine the approximate divergence of your laser beam and use the Nomogram ( vs. Wavelength) Chart to select the low divergence or high divergence configuration. Confirm your beam size is <25 mm diameter for the low divergence configuration or <12 mm for the high divergence configuration. Use the table below to determine the selected configuration part number and verify all other beam specifications. If more than one configuration is indicated to cover all needed beam parameter ranges, optional Scanning Head Modular Components can be ordered to change the configuration of the system to cover other ranges (see back page for details). (mr) 20.0 10.0 8.0 6.0 4.0 2.0 1.0 0.8 0.6 0.4 0.3 0.2 M 2 = 1 0.1 100 200 400 600 800 1,000 2,000 5,000 10,000 20,000 UV Nomogram VIS N Wavelength (nm) High High Low Low STANDARD CONFIGURATIONS UV Low UV High VIS Low VIS High N Low N High High Low Part Number 33-1843-000 33-2106-000 33-2221-000 33-2239-000 33-2387-000 33-2395-000 33-2429-000 33-2437-000 Model MM -1-1 S -2-2S -3-3S -4-5 Range 0.22-0.68 µm 0.34-1.00 µm 0.80-1.80 µm 1.80-15 µm Detector Type Silicon Germanium Pyroelectric INPUT BEAM REQUEMENTS AT TEST WAVELENGTH Test Wavelength a 351 nm 514 nm 1.06 µm 10.6 µm Minimum b 7.5 mw c 2.5 mw c 2.5 mw 400 mw Maximum b 10W c 25W c 2.5W 20W Noise <2% RMS and <5% peak-to-peak Min. (mrad) 0.24 0.46 0.24 0.46 0.25 e 0.47 e 2.7 1.3 Max. (mrad) d 1.7 3.2 2.0 3.6 2.7 5.0 14 7.2 Max. Dia. (mm) f 25 12 25 12 25 12 12 25 a Wavelength-dependent quantities are input power levels, and minimum and maximum divergence (see notes b, e, f). b levels are proportional to the inverse of the spectral response of the detector. The silicon detector peaks at 900 nm and is at half-peak sensitivity at 510 nm and 1050 nm. The germanium detector peaks at 1500 nm and is at half-peak sensitivity at 1100 nm and 1650 nm. The pyroelectric detector has a flat spectral response. c These limits can be reduced by a factor of 10 (higher sensitivity) by user-removal of the light-restricting aperture in front of detector. d The maximum divergence limit is fixed by the inability to accurately locate the internal waist when the internal beam diameter growth (over the span of the drum) is too slight. Limits shown are for M 2 = 1 and test wavelength; limits scale as the square root of M 2 (test wavelength). e Minimum divergence in this wavelength range scales as the square root of M 2 (test wavelength). f Diameters are approximate; divergence takes precedence in choosing options. Refer to nomogram. 80

Coherent Laser Measurement and Control Components for Other Wavelength and Ranges The body design of the scanning head has modular lens and detector sets that allow quick changes to other wavelength or divergence ranges to suit your measurement needs. High- Lens () Lens Tube Body Detector P y r o The body can only be used with the (Pyroelectric - Pyro) detector and either the low- or high-divergence heads. But, the UV-VIS-N body can be used in any of the UV, VIS or N spectral regions, with the appropriate detector (Silicon - Si for the UV and VIS; Germanium - Ge for the N) and low- or high-divergence lenses. The UV lens can be used with the Silicon detector and the VIS-N lens can be used with either the Silicon or Germanium Detectors. Part Number Region(s) Description 33-2072-000 UV, VIS Silicon Detector (0.22-1.0 µm) 33-2080-000 N Germanium Detector (0.8-1.8 µm) 33-2098-000 Pyroelectric Detector (1.8-20 µm) 33-2114-000 UV High- Lens Kit (UV-VIS-N Body Only) 33-2130-000 UV Low- Lens Kit (UV-VIS-N Body Only) 33-2122-000 VIS, N High- Lens Kit (UV-VIS-N Body Only) 33-2148-000 VIS, N Low- Lens Kit (UV-VIS-N Body Only) 33-2155-000 High- Lens Kit ( Body Only) 33-2166-000 Low- Lens Kit ( Body Only) Lens Tube Extension + Low- Lens () High- Lens (UV or VIS-N) Visible Lens Tube Low- Lens (UV or VIS-N) Body Detector Si Ge UV VIS N SPECIFICATIONS Accuracies Waist Diameter ±2% Waist Location ±8% of input beam Rayleigh Range Quality - M 2 ±5% ±5% Translation ±[5% of waist diameter +0.1 mm] Pointing Angle ±[5% of divergence +0.04 mrad] Azimuth Angle Readout ±2 (10-200 ) Knife-Edge Clip Levels User-adjustable 0% to 100% in 1.5% steps Control/ Interface Module Update Rate Analog Outputs Digital Outputs <8 Hz (M 2, divergence, power density, waist diameter, profiles) Detector signal output, 0-13V maximum. A/D control signal out, 0-5V pulse. Trigger (syncs to drum rotation), 0-5V pulse. RS-232 interface. Front and back knife-edge widths and pinhole profiles available in digitized form via RS-232. Scan Head and Precision Mount 108 mm (4.25 in.) Control/Interface Console 86 mm (3.4 in.) L 305 mm (12.0 in.) VIS UV N 358 mm (14.1 in.) High- 409 mm (16.1 in.) Low- 45 mm (1.8 in.) 235 mm (9.25 in.) ModeMaster PC 310 mm (12.2 in.) 360 mm (14.2 in.) 65 mm to 235 mm (2.56 in. to 9.25 in.) 100-240 VAC, 47 to 63 Hz, 40W maximum 299 mm (11.8 in.) M 2 Propagation Analyzer (Standard System Configuration) Part Number Description 33-1843-000 Scan Head, Mount, Control/Interface Console and Software for UV, Low- s 33-2106-000 Scan Head, Mount, Control/Interface Console and Software for UV, High- s 33-2221-000 Scan Head, Mount, Control/Interface Console and Software for VIS, Low- s 33-2239-000 Scan Head, Mount, Control/Interface Console and Software for VIS, High- s 33-2387-000 Scan Head, Mount, Control/Interface Console and Software for N, Low- s 33-2395-000 Scan Head, Mount, Control/Interface Console and Software for N, High- s 33-2429-000 Scan Head, Mount, Control/Interface Console and Software for, High- s 33-2437-000 Scan Head, Mount, Control/Interface Console and Software for, Low- s 33-1710-000 Control/Interface Console and Software 81