Telemetrie-Messtechnik Schnorrenberg

Similar documents
Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

User Manual CTP4/8/16

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

Kraus Messtechnik GmbH

MTP-NT. Preliminary version Sophisticated multi-channel telemetry system for rotating application, fully software programmable with 16 bit resolution

MTP-NT INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

User Manual MTP Multi-channel telemetry system for rotating application, full software programmable with 16 bit resolution

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

SC-4/M User manual 4-channel measuring amplifier

KMT - Kraus Messtechnik GmbH

Dx: Digital Multi-Channel Telemetry System

KMT - Kraus Messtechnik GmbH

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

KMT - Kraus Messtechnik GmbH

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Series GLET Accessory for dataloggers series GL in modular enclosure

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Calibration and Testing

The wireless alternative to expensive cabling...

Digital Telemetry Solutions

Torque Sensor Accessories and Services

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Wind Transmitter First Class

Digital Telemetry Solutions

Analog Signal Conditioning Accessories

ICPU2-8 for imc CRONOSflex (CRFX/ICPU2-8)

PCM - Sensor Telemetry for Turbo Prop/Jet Application

Series CCS-37S/CS-37S Miniature DC 18 GHz Failsafe TRANSFER Coaxial Switch

Series CCS-47/CS-47 High Power DC 12 GHz Failsafe TRANSFER Coaxial Switch

Kistler LabAmp for DynoWare

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Series CCS-37S/CS-37S Miniature DC 18 GHz Latching TRANSFER Coaxial Switch

Series CCT-59S/CT-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

Modular Radio Telemetry System

Modular Radio Telemetry System

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Temperature Transmitters - Head Mounted

The wireless alternative to expensive cabling...

FC Series Signal Conditioners

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Model 140 Inline Amplifier

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

MX1615. Data sheet. Bridge/strain gauge amplifier

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

Load Cell Accessories and Services

Series CCS-47/CS-47 High Power DC 12 GHz Latching TRANSFER Coaxial Switch

Wind Transmitter First Class Advanced Classified according to IEC ( )

MICROTC LINEAR THERMOCOUPLE AMPLIFIER OPERATOR S MANUAL

CSG110 Strain Gauge Universal Amplifier

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Signal Conditioning Amplifier

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

WIND VANE THIES FIRST CLASS 2014 TMR

The wireless alternative to expensive cabling...

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Series CCT-38S/CT-38S Multi-Throw DC 18 GHz/DC-22 GHz Normally Open Coaxial Switch

WIND VANE THIES COMPACT

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Series CCR-39S/CR-39S Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

This Errata Sheet contains corrections or changes made after the publication of this manual.

Series CCR-48K/CR-48K Multi-Throw DC 40 GHz Normally Open Coaxial Switch

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

200, 201 Series Radio Telemetry Transmitters

Modular Smart Interfaces

IBV 100/EXE 100 Interpolation and Digitizing Electronics

Digital RMC-Sensor-Telemetry with 16 Bit resolution and direct PC Interface

Series CCR-33S/CR-33S Miniature DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

Series CCR-33K/CR-33 K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Temperature Transmitters - DIN Rail Mounted

GSV-2MSD-DI IP43. Highlights

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Pressure Transmitter SIL

Series CCT-38S Multi-Throw DC 12 GHz, SP7T & SP8T Normally Open Coaxial Switch

Transcription:

Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53, Mobil: 0171-8902387 Bankverbindung: Sparkasse KölnBonn, Kto.-Nr: 1900310663, BLZ: 370 501 98

General functions: 16 x Sensor cables CT16-Wheel encoder / transmitter Receiving antenna CT16-Rotate receiver DC power cable AC/DC Converter (OPTION) ECIA PCM Interface with cable (OPTION) Battery charger Cover lift help Hexagon screw driver 350 Ohm test bridge PCM serial to parallel adapter (OPTION) CT16-Wheel is an telemetry system designed for easy mounting onto rotating Wheels to provide non-contact transmission of measured parameters such as pressure, force, temperature, acceleration and voltage. Sensors inputs are connected via screw on, waterproof connectors. Measured values are prepared in analog format, digitized and transmitted via radio frequencies. Four different carrier frequencies are provided, this allows up to four systems (e.g. for four wheels) to operate in parallel. The complete transmitter assembly is waterproofed to IP65 specifications. The following sensors can be connected to the system: (STG) Strain gages sensors in full-, half- and quarter-bridge configuration (350 ohm or greater), Type K Thermocouples -50 to 1000 C (full galvanic isolated), ICP and capacitive sensors. Voltage inputs of +/-5V and +/-10V are available. The measured values are processed and output as +/-5V analog signals at the BNC sockets (optional digital output for special PCM interface into a PC) on the stationary receiver located in a vehicle. Resolution of 12 bits is standard; this enables an amplitude dynamic of 72 db. The analog signal bandwidth is 0-95 Hz (-3dB) when configured as an eight channel unit, other bandwidth on request! The measurement accuracy is +/-0.25 % (without sensor). The CT4/8-Wheel is suited for operation at ambient temperatures of -20 to +70 C. The transmission distance between transmitter and receiving antenna is of the order of 20m (60 feet) - depend of application! Version 2012-11 2 Technical Data are subject to change without notice!

CT16-Wheel Transmitting Unit Technical Data (Encoder) Encoder in IP65 Aluminum housing Encoder inside SC Module STG: Sensor: Bridge completion: Excitation: Gain: Offset SC Module ICP: Constant current: Gain: SC Module POT: Sensor: Excitation: SC Module TH-K: Sensor: measuring range: SC Module VOLT: High-level inputs: System Parameters: Channels: Resolution: Line-of-sight distance: Powering: Power consumption: Analog signal bandwidth: Transmitter carrier frequency: Transmission: Transmission Power: Weight: Operating temperature: Housing: Humidity: Vibration: Static acceleration: Shock: strain gage, > 350 Ohms full, half and quarter-bridge (optional quarter-bridge with 120Ohme) 4 VDC (fixed), short-circuit protection up to 20mA 200 or 1000 - selectable by solder jumpers (5mV/V or 1mV/V) Zero adjustment by potentiometer or optional Auto-zero function (which is not lost by power-off), offset range up to 80% of full scale. 1, 4, or 10mA 2x, 4x, 8x, 16x or 32x Potentiometer Sensor >350 Ohms 4 VDC (fixed) thermo-couple, type K ( with cold junction compensation) Inputs full galvanic isolated! -50 C to +1000 C (other on request) +/- 5 Volt or +/- 10 Volt 16 (may be configured using 1 to 16 channels) 12 bit A/D converter with anti aliasing filter, simultaneous sampling of all channels 20m with 10mW transmitting power, (433MHz Band, FSK modulation) Li Ion Accumulator 7.2V, 2000mA, capacity for 6-8 hours. 350 ma using 16x STG full bridge sensors 350 Ohms 16 x 0 375Hz (scanning rate 1632Hz) with 320kbit/s transmitter (-3dB) 1 x 433,3 MHz with 320kbit/s Digital PCM Miller format - FSK 10mW 2.1 kg without cables - 20 +70 C Aluminum anodized, waterproofed (IP65) 20... 80% no condensing 5g Mil Standard 810C, Curve C 100g in all directions 200g in all directions Version 2012-11 3 Technical Data are subject to change without notice!

Technical data: Receiving Unit CT16-Wheel DEC with analoge and digital out (Decoder) Male 37 pole Sub-D connector for analog signal outputsochannels 1 to 16 Female TNC connector Field strength display Power LED Power Switch 7-pole female TUCHEL connector for power supply input (10 30V DC) Syncloss LED PC Interface out Front side view Auto Zero LED indicator Rear side view Pin connection 37pol Sub-D male Optional BNC16 Box. Connect on 37pol Sub-D Version 2012-11 4 Technical Data are subject to change without notice!

System Parameters: Channel: Resolution: Dynamic: Power supply input: Current consumption: Transmitter carrier frequency: Transmission: Dimensions: Weight: Overall system accuracy between encoder input and decoder output: Environmental Operating: Humidity: Vibration: Static acceleration: Shock: 16 +/-5V analog outputs via Sub-D male socket 12 bit D/A converter, with smoothing filter 72dB 10-30 VDC, power consumption 3 Watt 300mA at 10V, 100mA at 30V 433,3 MHz with 320kbit/s Digital PCM Miller Format - FSK 205 x 105 x 65mm 1.25 kg without cables and antenna +/-0.25% without sensor influences -20 +70 C 20... 80% not condensing 5g Mil Standard 810C, Curve C 10g in all directions 100g in all directions Technical specifications are subject to change without notice! Version 2012-11 5 Technical Data are subject to change without notice!

Functions: 16 Channel CT16-Wheel ENC (encoder/transmitter) Sensor Inputs CH1... 16 Battery charge Input socket Green = Power ON Red = Batt. empty Antenna ON/OFF Switch Untwist to open the housing with hexagon screw driver 2mm To lift the cover, use the slot! Picture shows the CT16-Rotate as example! Take care with the O-ring seal, it is lubricated with silicone grease! Version 2012-11 6 Technical Data are subject to change without notice!

Connection, STG bridge configuration: CT16-Wheel ENC (encoder) Black = IN - White = IN + Brown = EXC + Blue = EXC - STG module Type: Strain gage >350 Ohms Excitation: 4 VDC (fixed) Gain: 200 or 1000 Sensor cable Sensor modules Sensor socket Offset Potentiometer Plug at CT16-Wheel ENC CH: 1-2-3-4-5-6-7-8-9-10-11-12-13-14-15-16 Gain Gain 1000 - factory setting! Offset Plug bridge configuration at STG e.g.: Offset calibration and Gain setting: Gain 200 or 1000 Offset potentiometers by solder bridge Auto Zero calibration Optional! Version 2012-11 7 Technical Data are subject to change without notice!

Connection POT: POT module Type: Potentiometer >350 Ohms Excitation: 4 VDC (fixed) Attention: The POT modules must be configured as a Half Bridge Unit. Don t change offset and gain!! Connection Volt +/- +/- Volt module Type: Range: Volt +/-5 or +/-10V Attentions: At Volt modules must plug the plug bridge on Half Bridge Unit. Don t change offset!! Connection ICP Gain: 32 16 8 4 ICP module Type: ICP Gain: 2x, 4x, 8x, 16x or 32x Constant current: 1, 4 or 10mA Attentions: At Volt modules must plug the plug bridge on Half Bridge Unit. Current: 10 4 1 Version 2012-11 8 Technical Data are subject to change without notice!

Connection Th K (without galvanic isolation!) Thermo couple Type: K Range: 0 1000 C Bandwidth: 0-20Hz (more on request) Not galvanic isolated! Attentions: At Thermo couple must plug the plug bridge on Half Bridge Unit. Don t change offset!! 0-5,003 250-2,546 500 0,002 750 2,558 50-4,515 300-2,044 550 0,515 800 3,061 100-4,009 350-1,538 600 1,031 850 3,550 150-3,516 400-1,029 650 1,542 900 4,035 200-3,031 450-0,515 700 2,052 1000 5,000 Connection Th K-ISO (with galvanic isolation!) Thermo couple Type: K Range: -50 C 1000 C Bandwidth: 0-20Hz (more on request) Galvanic isolated! Attentions: At Thermo couple must plug the plug bridge on Half Bridge Unit. Don t change offset!! -50-0.220 250 1.236 550 2.754 850 4.262 0 0.013 300 1.482 600 3.010 900 4.506 50 0.254 350 1.734 650 3.266 950 4.746 100 0.504 400 1.990 700 3.519 1000 4.980 150 0.752 450 2.242 750 3.700 200 0.992 500 2.498 800 4.015 With option +/-10V output you must multiply the table value with *2 Version 2012-11 9 Technical Data are subject to change without notice!

Configuration example: CH. 1-3-5-7-9-11-13-15 with STG and CH. 2-4-6-8-10-12-16 with+/-5 Volt input modules Don, t change the offest at Volt modules!! Volt = 16 14 12 10 8 6 4 2 STG = 15 13 11 9 7 5 3 1 Version 2012-11 10 Technical Data are subject to change without notice!

Li Ion Re-Chargeable Battery with Charger Unit for CT16-Wheel (CT4-Wheel) Pin connection Battery charger CT16-Rotate 1. Plug the 3- pole socket (charger) in to the CT16-Wheel encoder. 2. Plug banana plugs on to a battery or AC/DC power supply with a voltage range of 10-30V DC. 3. If charging not begins, press for 1 second the switch to begin charging. The battery will now charge. Charge time 5-6 hours. Press to start 1s Charge Batt. LED Full status LED Attention: Li Ion battery (7.2V, 2000mA) has a capacity for 5 hours. If the red LED indicator (Control) on the CT16-Encoder is ON the battery is 80% discharged and the device will switch off after 20 minutes! Mounting hole dimensions: Hole diameter 8.2mm Hole circle diameter 206mm Base plate side Version 2012-11 11 Technical Data are subject to change without notice!

Dimensions: 190mm 220mm 81m 66mm Total weight 2.1kg Version 2012-11 12 Technical Data are subject to change without notice!