Application of AGPU for Matrix Converters

Similar documents
Closed Loop Single Phase Bidirectional AC to AC Buck Boost Converter for Power Quality Improvement

DUAL CONVERTER CONTROLLED SINGLE PHASE MATRIX CONVERTER FED DC DRIVE

Modeling and Simulation of a Single Phase Matrix Converter with Reduce Switch Count as a Buck/Boost Rectifier with Close Loop Control

Implementation of a Single Phase Z-Source Buck-Boost Matrix Converter using PWM Technique

Control of buck-boost chopper type AC voltage regulator

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

Overview of Single Phase Matrix Converter Application

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

Single Phase Matrix Converter as a Frequency Changer with Sinusoidal Pulse Width Modulation using Matlab

Multilevel Inverter for Single Phase System with Reduced Number of Switches

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

Modified Single Stage AC-AC Converter

SIMULATION OF FOUR SWITCH PWM AC CHOPPER FED SINGLE PHASE INDUCTION MOTOR. M. Narendra Kumar and K.S.R. Anjaneyulu

Literature Review. Chapter 2

Modified Resonant Transition Switching for Buck Converter

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

Selected paper. Voltage Controlled Single Phase Matrix Converter with Low Harmonics

New model multilevel inverter using Nearest Level Control Technique

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

A Novel Single-Phase Z-Source Buck-Boost Matrix Converter

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

Generation of Switching pulses for a 3 x 3 Matrix Converter

A New Soft Switching ZCS and ZVS High Frequency Boost Converter with an HI-Bridge Auxiliary Resonant Circuit to Drive a BLDC Motor

Development of a Single-Phase PWM AC Controller

International Journal of Pure and Applied Mathematics

Minimization Of Total Harmonic Distortion Using Pulse Width Modulation Technique

Comparison of SPWM,THIPWM and PDPWM Technique Based Voltage Source Inverters for Application in Renewable Energy

Lecture Note. DC-AC PWM Inverters. Prepared by Dr. Oday A Ahmed Website:

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

Anfis Based Soft Switched Dc-Dc Buck Converter with Coupled Inductor

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

A Hybrid Cascaded Multilevel Inverter for Interfacing with Renewable Energy Resources

Transient and Steady State Analysis of Modified Three Phase Multilevel Inverter for Photovoltaic System

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Simulation and Experimental Results of 7-Level Inverter System

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

Speed Control of Induction Motor using Multilevel Inverter

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

Modeling and Implementation of Closed Loop PI Controller for 3 Phase to 3 Phase Power Conversion Using Matrix Converter

SWITCHING FREQUENCY HARMONIC SELECTION FOR SINGLE PHASE MULTILEVEL CASCADED H-BRIDGE INVERTERS

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES

Lecture 19 - Single-phase square-wave inverter

AN EFFICIENT CLOSED LOOP CONTROLLED BRIDGELESS CUK RECTIFIER FOR PFC APPLICATIONS

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

International Journal of Advance Engineering and Research Development

COMPARATIVE HARMONIC ANALYSIS OF VSI FED INDUCTION MOTOR DRIVE

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

A Predictive Control Strategy for Power Factor Correction

A Five Level Inverter for Grid Connected PV System Employing Fuzzy Controller

Design and Implementation of Photovoltaic Inverter system using Multi-cell Interleaved Fly-back Topology

ADVANCES in NATURAL and APPLIED SCIENCES

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

Buck Boost AC Chopper

A Three Phase Seven Level Inverter for Grid Connected Photovoltaic System by Employing PID Controller

PF and THD Measurement for Power Electronic Converter

This paper deals with a new family of high boostvoltage inverters, called switched-inductor quasi-z-source inverters.

Closed Loop Control of Three-Phase Induction Motor using Xilinx

Performance Analysis of The Simple Low Cost Buck-Boost Ac-Ac Converter

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Micro-controller Based Three-phase Voltage Source Inverter for Alternative Energy Source. Abstract

29 Level H- Bridge VSC for HVDC Application

Application of Fuzzy Logic Controller in Shunt Active Power Filter

BIDIRECTIONAL SOFT-SWITCHING SERIES AC-LINK INVERTER WITH PI CONTROLLER

Symmetrical Multilevel Inverter with Reduced Number of switches With Level Doubling Network

Implementation Full Bridge Series Resonant Buck Boost Inverter

Inter Harmonics of Cycloconveter Excited Induction Motor and Design its Filter Circuit

Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

SIMULATION OF THREE PHASE MULTI- LEVEL INVERTER WITH LESS NUMBER OF POWER SWITCHES USING PWM METHODS

Simulation of Solar Powered PMBLDC Motor Drive

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

IMPLEMENTATION OF FM-ZCS-QUASI RESONANT CONVERTER FED DC SERVO DRIVE

CHAPTER 2 MATRIX CONVERTER (MC)

Simulation of AC-DC Converter for High Power Application

Student Department of EEE (M.E-PED), 2 Assitant Professor of EEE Selvam College of Technology Namakkal, India

Analysis of Solar PV Inverter based on PIC Microcontroller and Sinusoidal Pulse Width Modulation

PV MICROINVERTER TOPOLOGY USING SOFT SWITCHING HALF- WAVE CYCLOCONVERTER

CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

ISSN Vol.07,Issue.16, November-2015, Pages:

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

SVPWM Rectifier-Inverter Nine Switch Topology for Three Phase UPS Applications

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

A New Active Power Factor Correction Controller Using Boost Converter

A Five-Level Single-Phase Grid-Connected Converter for Renewable Distributed Systems

Design of Three Phase PWM Voltage Source Inverter for Induction Heater

Unipolar and Bipolar PWM Inverter

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

SIMULATION OF SINGLE PHASE H- BRIDGE INVERTER TO AVOID COMPLEX BEHAVIOUR

Closed Loop Control of Boost Converter for a Grid Connected Photovoltaic System

Transcription:

International Journal of Power Electronics and Drive System (IJPEDS) Vol. 5, No. 1, July 214, pp. 129~134 ISSN: 288-8694 129 Application of AGPU for Matrix Converters Nithin T Abraham, C.A Pradeep Kumar, Shaema Lizbeth Mathew Departement of Electrical and Electronics Engineering, Karunya University, Coimbatore, Tamil Nadu, India Article Info Article history: Received Dec 11, 213 Revised May 25, 214 Accepted Jun 2, 214 Keyword: Matrix Converter, sinusoidal PWM, Aviation ground power unit, PI control loop. ABSTRACT A simple PI control loop for the matrix converter system is designed in the simulation to maintain a constant output voltage inspite of any disturbance in the source. The single phase matrix converter employs a modified safecommutation strategy, which results in the elimination of voltage spikes on switches, without the need of a snubber circuit when there is an inductive load being utilized. This is facilitated through the proper switching control algorithm. The sine PWM pulses are generated as switching pulses to the converter to reduce the THD. Copyright 21x Institute of Advanced Engineering and Science. All rights reserved. Corresponding Author: Nithin T Abraham, Departement of Electrical and Electronics Engineering, Karunya University, Coimbatore,Tamil Nadu,India Email: nithinthamaravelil@gmail.com 1. INTRODUCTION The topology was first introduced by Gyugyi and Pelly [1] in 1976. In 198, Venturini and Alesina described it as a generalized transformer a bidirectional sinusoidal waveform frequency converter [2]. The single phase version called the Single-phase Matrix Converter (SPMC) was first introduced by Zuckerberger [3], based on the direct AC-AC converter.static power converters are used for many applications, like frequency converters for motors, uninterruptible power supplies, (UPS), general power supplies and also for Ground Power Units (GPU) for airplanes.a new control strategy for a Ground Power Unit (GPU) is proposed, which is used for airplanes on the ground [4]. The control is performed by a PWM-modulator and a voltage controller. It is concluded from the experiments, that the new controller gives a high output performance both stationary and dynamic, at linear and non-linear loads.in this paper, a SPMC with a modified safecommutation technique that gives an output of 11V/4 Hz, is designed. As this modified safe-commutation scheme provides a continuous current path in dead time also, it eliminates voltage spikes on switches without the need for a snubber circuit. The operation and basic behaviour of the same is examined through computer simulation. A voltage controller gives the input to the modulator, which controls the converter. The Single Phase Matrix Converter, for voltage applications like the AGPUs, requires step-changed frequency, and/or variable amplitude. 2. AVIATION GROUND POWER UNIT An Aviation Ground Power Unit supplies airplanes with external electrical power, during stopover in airports. Its application is presently well-established in airports all over the world, primarily due to airport regulations that require the transition to external power in order to reduce acoustic noise and air pollution from jet engines. GPUs have both been built as rotating motor-generator systems and recently as solid-state converters. The solid-state solution has been accepted as a standard, due to low maintenance, lower price, high Journal homepage: http://iaesjournal.com/online/index.php/ijpeds

13 ISSN: 288-8694 reliability and efficiency. This increases continuously the demands of advancement in the GPU. The development of GPUs is benefited from the development of micro-controllers and power semiconductors. With enormous computational power, digital control units are becoming much faster, more advanced and low price. GPUs have a need for great computational power, because of the 4 Hz fundamental frequency and the increasing demands of the GPUs. The high fundamental frequency results in a low ratio between the switching frequency (2-1 khz in the present power range) of the converter and the fundamental output frequency (4 Hz). Existing systems have been equipped with optimized modulation schemes like sine pulse width modulation and equal pulse width modulation scheme, which minimize the harmonic distortion. Thus, the need for filtering is reduced and smaller filter components are sufficient. 3. MATRIX CONVERTER FOR AGPU Figure 1 shows the block diagram of the SPMC. The frequency of the input voltage is modulated in the SPMC. Thus, the output voltage is obtained with a step-changed frequency and variable amplitude. The LC input filter is required to reduce the switching ripple in an input current. Figure 2 shows the matlab simulation circuit of the SPMC. It uses four bi-directional switches to serve as an SPMC. This arrangement has the advantage of an independent control of the current in both directions. Since these bidirectional switches are not available at present, they are substituted with two diodes and two IGBT s, connected anti-parallel. IGBTs are used because of their high switching capabilities and high current carrying capabilities, leading to high power applications. Diodes are included to provide the reverse voltage blocking capability. Figure 1. Block diagram of SPMC Figure 2. Matlab simulation Circuit diagram of Single Phase Matrix Converter Implementing this SPMC requires different switching arrangements based on the desired amplitude and frequency. The amplitude of the output voltage is controlled by varying the modulation index of the sine/equal PWM pulses, and the frequency of the output voltage depends on the switching strategy. Furthermore, if inductive loads are used, a change in instantaneous current across the inductance will produce large voltage spikes, that will destroy switches in use, due to stress. A systematic switching sequence is thus required, that allows for the energy flowing in the IGBTs to dissipate within the system. In this paper, the frequency of the input voltage is taken as 5Hz, and the desired output frequency is assumed to be 4Hz. The switching strategies for this desired output frequency is given further in detail for better understanding. 4. SWITCHING STRATEGY The operation of the SPMC can be explained in four modes as shown in figure 3. The desired output frequency is then synthesized by the proper sequencing of these four modes. IJPEDS Vol. 5, No. 1, July 214 : 129 134

IJPEDS ISSN: 288-8694 131 (a) (b) (c) (d) Figure 3. Equivalent Circuits for (a) Mode-1, (b) Mode-2, (c) Mode-3, (d) Mode-4 The sequence of the switching control for an output frequency of 4Hz without safe commutation is given in Table 1. Table 1. Sequence of Switching Control Input Output Mode Switches frequency frequency on 5Hz 4Hz To generate sinusoidal PWM signals for the switches of the matrix converter, a model is developed, and the same is shown as a separate subsystem in Figure 4.The state selector signal portion implements the operation of the required switching state of Table 1. Here, the square wave pulse represents the desired output frequency, which is generated by the "pulse generator" block. The final switching pattern for the SPMC is Application of AGPU for Matrix Converters (Nithin T Abraham)

132 ISSN: 288-8694 produced, by multiplying the output from the SPWM generator with the state selector signal, using the "multiply" block. Each output from the "pulse generator" is multiplied with both outputs from the SPWM. Figure 4. Four subsystems to generate Sine PWM pulses 5. RESULTS AND DISCUSSIONS The simulation results of the SPMC for R and RL Loads without and with safe commutation strategy is discussed below. 5.1. Simulation Results of the SPMC for R Load output voltage in volts 25 2 15 1 5-5 -1-15 -2-25.5.1.15.2.25.3.35.4 time in secs Figure 5. Output voltage for R Load: 4 Hz 5.2. Simulation Results of the SPMC for RL Load without safe commutation The single phase matrix converter for RL load without safe commutation delivers an output voltage as shown in the waveform below in the figure.6 for 4 Hz consist of spike with magnitude up to ten times higher than the normal output voltage which needs to be eliminated by following a safe commutation technique without engaging a separate snubber circuit. output voltage in volts 3 2 1-1 -2-3.5.1.15.2.25.3.35.4 time in secs Figure 6. Output voltage of RL Load without safe commutation strategy: 4 Hz IJPEDS Vol. 5, No. 1, July 214 : 129 134

IJPEDS ISSN: 288-8694 133 5.3. Simulation Results of open loop simulink model with disturbance in AGPU 25 2 output rms voltage 15 1 5.1.2.3.4.5.6.7.8.9 1 Figure 7. Output voltage waveform of open loop with disturbance 5.4. Simulation Results of closed loop simulink model with disturbance in AGPU 12 1 output rms voltage 8 6 4 2.1.2.3.4.5.6.7.8.9 1 time in secs Figure 8. Output voltage waveform of closed loop with disturbance 6. CONCLUSION Thus the output voltage waveform shown in figure.8 is suitable for the avionics use due to its consistency even during the distortions. Also the output voltage rms with a magnitude of 11V/4Hz is obtained to supply the airplanes during stopovers at the airports. The Single Phase Matrix Converter, with Sinusoidal pulse width modulation switching techniques, has been used with for R and RL loads. The spikes generated in the output voltage during switch transitions, are reduced with a safe commutation strategy, which provides a continuous current path in dead time, without a snubber circuit. The simulation using this simple PI control structure is carried out, to verify the consistency of the output voltage. Also, the proposed structure provides a compact solution with no DC link. REFERENCES [1] L.Gyugyi and B.R.Pelly, Static Power Frequency Changers: Theory, Performance and Application. New York: Wiley, 1976. [2] Nithin T Abraham, K Vinoth Kumar, Vicky jose, Dona maria Mathew, S.suresh kumar, SAR Algorithm Method in Photovoltaic Systems Using MPPT, in International journal of Power electronics and drives systems (IJPEDS), Vol 3,no 4, December 213, pp:438-443. [3] M.Venturini and A.Alesina, The generalized transformer: A new bidirectional sinusoidal waveform frequency converter with continuously adjustable input power factor, in Proc. IEEE PESC 198, pp. 242-252. [4] A.Zuckerberger, D.Weinstock and A.Alexandrovitz, Single-phase matrix converter, in Proc. Inst. Electrical Engineering Electric Power Application, 1997, Vol. 144, pp. 235-24. [5] Uffe Borup Jensen, Morten Peter Rasmussen,,Tonny Mortensen. A New Control Method for 4 Hz Ground Power Units for Airplanes, IEEE 1998, pp. 464-47. [6] R.Baharom, Hasim M.K.Hamzah, Omar, A new single-phase controlled rectifier using SPMC, IEEE PECon 26, pp. 453-458. [7] Kwon, B.-H., Min, B.-D., Kim, J.-H., "Novel Commutation Technique of AC-AC Converters," Electric Power Application, (e) EE Proceedings-, Vol. 145 (4), July 1998, pp. 295-3. Application of AGPU for Matrix Converters (Nithin T Abraham)

134 ISSN: 288-8694 BIOGRAPHIES OF AUTHORS Nithin T.Abraham received his B.Tech. degree in Electrical and Electronics Engineering from Karunya University, Coimbatore, Tamil Nadu, India. Presently he is pursuing M.Tech in Renewable Energy Technologies from Karunya University, Coimbatore, Tamil Nadu, India. His present research interests are Neural Networks and Fuzzy Logic, Special machines, Application of Soft Computing Technique, Solar PV based power generation. C.A Pradeep Kumar received his B.Tech. degree in Electrical and Electronics Engineering from park college of engineering and technology, Coimbatore, Tamil Nadu, India. Presently he is pursuing M.Tech in Renewable Energy Technologies from Karunya University, Coimbatore, Tamil Nadu, India. His present research interests are Application of Soft Computing Technique, Hybrid vehicles, Renewable energy. Shaema Lizbeth Mathew received her engineering degree in Electrical and Electronics from Federal Institute of Science and Technology (FISAT), Ernakulam in 211. She is pursuing her master s degree in Renewable Energy Technologies from Karunya University, Coimbatore. Her field of interest concerns the photovoltaic power and MATLAB coding. IJPEDS Vol. 5, No. 1, July 214 : 129 134