Parallel. Parallel. data transmission. Technical Information TR - ECE - TI - GB /05/2016

Similar documents
Absolute encoder HE-65

PT100N - Operating instructions

Laser Measuring Device LE-200

User Manual. LP System. LA System. Absolute linear encoder LA/LP with CAN DeviceNet interface. Linear Encoders. System. Motion.

PU202 Level converter & encoder signal generator without potential separation

Operating Instructions. for. Controller SMS 150 / 151

IF30. User's manual. Description. Table of contents IF30

MAI-4. Technical Documentation Analog Input Submodule. Please keep for further use!

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Rotary Measuring Technology

Incremental encoders 6

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Rotary Measuring Technology

Operating instructions Electronic level sensor LK / / 2008

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

SIMATIC. ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB52-0AB0) Preface. Properties 1. Parameters 2.

IP 251 Universal Signal Converter SSI parallel RS232 parallel SSI RS232

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

LD200. User manual. Description. Chapters LD200

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

Max. sp Min. spe Negativ speed s Synchro out speed refere selection Menu 13. g t x (-1) UMV 4301

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

LENORD. +BAUER... automates motion. GEL 2037 with heavy duty flange or tooth wheel adapter. Technical information Version General.

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

IT 251. Level Converter and Programmable Impulse Divider. Operating Instructions. control motion interface

Position Transmitter TGS 40 (RAM)

F4-08RTD 8-Channel RTD Input

Glossary of Technical Terms

Operating Instructions. for. Controller SMS 160 / 161

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

ECOS SRIF Operating Instructions

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Power supply CP-D 12/2.1

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Advanced Test Equipment Rentals ATEC (2832)

Ref /b VARMECA 10 Variable speed motors and geared motors. Parameter-setting manual

External brake resistor AX2090-BW5x

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

Operating instructions Fail-safe delay timer AZS About this document. Content

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

UNIVERSAL-DDS-VFO UDV ( 1 Hz to 10 MHz)

8902/RE and 8902/RR Resolver Speed Feedback Options

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

TECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION

MV110-8AS. Analog input module 8 channel. User guide

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

HITACHI INVERTER INSTRUCTION MANUAL

Digital Interface Option "OPC-E1-DIO"

Installation guide 971 SmartRadar LTi

Power supply CP-T 48/5.0 Primary switch mode power supply

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Application Note (Revision NEW) Original Instructions. EMI Control in Electronic Governing Systems

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

This Errata Sheet contains corrections or changes made after the publication of this manual.

Product Data. (Cat. No DE)

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution

Power supply CP-T 48/20.0 Primary switch mode power supply

RMV25 / RMV50 RMU25 / RMU45

PU202. Encoder Signal Generator and Level Converter. Operating Instructions. control motion interface

1800 Series Attachable Loop-Powered Digital Indicators Operating Manual

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

937CU-AITXF-DC1 Installation Instructions. Transmitter Supply Converter

Select datum Page backward in. parameter list

F4 04DAS 1 4-Channel Isolated 4 20mA Output

Analogue Demo Multimeter ADM

User's guide SMA5 + MTA5. Absolute linear encoder. Smart encoders & actuators

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

Absolute encoder GEL 15X F. Serial (SSI) or parallel interface, PC-programmable. Technical information version 01.06

ENS31 Automatic Isolation Unit Product Description

Electrical data Units FVS 58, FHS 58. Operating voltage (PELV) [VDC] Current consumption at 24 VDC [ma] 85

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Operating Instructions

MultiMeter-Pocket CAT III 1000 V

Drive Electronics pq11

Absolute Encoders Singleturn

VARAN Stepper Module VST 012

Operating Instructions

This section is specifically about safety matters

Instruction manual for STA 1 sectional door operator

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

Power supply CP-T 24/10.0 Primary switch mode power supply

Absolute encoders - SSI Shaft with clamping or synchro flange Optical multiturn encoders 14 bit ST / 12 bit MT

Agilent AEDA-3300 Series Ultra Miniature, High Resolution Incremental Kit Encoders Data Sheet

Power supply CP-T 24/40.0 Primary switch mode power supply

Берг АБ Тел. (495) , факс (495) Initial operation and diagnosis

Power supply CP-E 24/20.0

This section is specifically about safety matters

Your Global Automation Partner. IMX12-DI01 Isolating Switching Amplifier. Safety Manual

Tube Facing Tool.

Series CE-65-S... INFO

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

Transcription:

TR - ECE - TI - GB - 0054-01 04/05/2016 Parallel Parallel data transmission Technical Information

TR-Electronic GmbH D-78647 Trossingen Eglishalde 6 Tel.: (0049) 07425/228-0 Fax: (0049) 07425/228-33 email: info@tr-electronic.de www.tr-electronic.com Copyright protection This Manual, including the illustrations contained therein, is subject to copyright protection. Use of this Manual by third parties in contravention of copyright regulations is not permitted. Reproduction, translation as well as electronic and photographic archiving and modification require the written content of the manufacturer. Violations shall be subject to claims for damages. Subject to modifications The right to make any changes in the interest of technical progress is reserved. Document information Release date / Rev. date: 04/05/2016 Document / Rev. no.: TR - ECE - TI - GB - 0054-01 File name: TR-ECE-TI-GB-0054-01.docx Author: MÜJ Font styles Italic or bold font styles are used for the title of a document or are used for highlighting. Courier font displays text, which is visible on the display or screen and software menu selections. < > indicates keys on your computer keyboard (such as <RETURN>). Page 2 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

Contents Contents... 3 Revision index... 4 1 Safety... 5 1.1 General hazard potential... 5 1.2 Safety information... 5 1.2.1 Hints on installation... 6 1.2.1.1 Screening... 7 1.2.1.2 General interference suppression measures... 7 1.3 Intended use... 8 1.4 Authorised operators... 9 1.5 Safety measures at the assembly site... 9 2 Parallel - Interface... 10 2.1 Description... 10 2.1.1 Principle block circuit diagram Push-Pull... 10 2.2 Control inputs... 11 2.3 Control outputs... 12 2.4 Codes... 14 2.5 Data outputs... 17 3 Data Transmission / Data Consistency... 18 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 3 of 18

Revision index Revision index Revision Date Index First release 20.02.01 00 General modifications 04/05/16 01 Page 4 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

1 Safety 1.1 General hazard potential The TR encoder can t function as a stand-alone unit, i.e. it is a component part that is intended to be installed in a complete system consisting of several such components working together. For this reason, the encoder does not have a protective device of its own. Depending of the encoder type, via the parallel interface different status bits can be transferred such as "encoder error" or "parity". This means that it is crucial to integrate the error bits into your own safety concept by means of the PLC's evaluation software. Further information about encoder control mechanisms can be taken from the documentation of the respective encoder type. If the encoder interface offers no possibility to check the encoder actual values or the transferred data to the control the user must take up corresponding measures. All persons involved in the assembly, start-up and operation of the device. must be appropriately qualified must follow the instructions in this manual exactly. This is for your own safety and the safety of your equipment! 1.2 Safety information This operating manual contains information which have to be considered to ensure your personal safety and to avoid damage to property. The information is emphasized by warning triangles, which have different appearances according to the degree of danger: Warning Means that death, severe injury or considerable damage to property can occur if the relevant safety measures are ignored. i Caution Means that slight injury or damage to property can occur if the relevant safety measures are ignored. Note Emphasizes important information about the product, its properties or helpful hints for using it. 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 5 of 18

Safety 1.2.1 Hints on installation In view of the fact that the TR encoder is normally used as a component part of a larger system, this information is intended as a guideline for the safe integration of the rotary encoder into its environment. Warning Observe the safety and accident prevention regulations relevant to the specific application. In the case of equipment with a fixed connection (stationary installations/systems) without all-pole mains switches and/or fuses, you must install a mains switch or fuse in the system and connect the equipment to a protective earth conductor. Before starting up devices that are run on mains voltage, check to make sure the set rated voltage range matches the local mains voltage. With a 24-V supply, ensure safe electrical isolation of the extra-low voltage. Only use mains units that comply with the standards IEC 364-4-41 or HD 384.04.41 (VDE 0100 Part 410). Fluctuations or deviations from the rated mains voltage may not exceed the tolerances stated in the technical data. If they do, functional failures of the electrical components and hazardous conditions cannot be ruled out. You must take precautions to ensure that an interrupted program can be resumed normally following voltage dips and failures. In this context, no dangerous operating status conditions may occur even for a brief period of time. If necessary, you must force an EMERGENCY STOP. EMERGENCY STOP devices that comply with EN 60204/IEC 204 (VDE 0113) must remain effective in all the operating modes of the automation equipment. Unlocking the EMERGENCY STOP devices must not result in an uncontrolled or undefined restart. Install the connecting and signal lines so that inductive and capacitive interference does not adversely affect the automation functions. Install automation technology equipment and its operator input elements so that they are sufficiently protected against accidental actuation. Take appropriate hardware and software precautions in the I/O link to prevent possible cable or wire breakage's on the signal side leading to undefined status conditions in the automation equipment. Page 6 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

1.2.1.1 Screening The use of electronic sensor active systems in modern machines necessitates a consistent and correctly executed interference suppression and wiring strategy. These conditions are the only guarantee that systems containing electronic measuring systems will function properly. Recommended screened cable wiring Switching Cabinet Measuring Systems Machine Control Unit 0V bar with screen terminal for measuring system cable Power Unit Measuring system and control cable Power Cable Ground cable 10 mm² (R ground cable << R screen ) 1.2.1.2 General interference suppression measures Route (screened) lines connecting to the encoder either a long way from or completely physically separated from energy lines that carry disturbances. Only use completely screened lines for data transfer and ensure that they are well earthed. In the case of differential data transfer, (RS422, RS485 etc.), you must use twisted-pair lines in addition. Use cables with a minimum cross-section of 0.22 mm² for data transfer. Use a ground cable with a minimum cross-section of 10 mm² to avoid equipotential current via the screen. Please note that the ground cable resistance must be much lower than that of the screen. Wire the screen continuously keeping a large area in contact with special screen connecting terminals. Avoid crossing cables. If this is not possible, the cables should only cross at rightangles. 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 7 of 18

Safety 1.3 Intended use The parallel encoder are used for the electronic interception of a rotating or linear movement as well as for the preparation of measured data for a controller with a parallel interface connected on the load side. Warning De-energize the system before carrying out wiring or opening and closing electrical connections! Short-circuits, voltage peaks etc. can lead to malfunctions and uncontrolled states in the system or to serious personal injury or damage to property. Check all electrical connections before switching on the system! Connections that are made incorrectly can lead to system malfunctions; wrong connections may result in serious personal injury or damage to property. Mechanical or electrical modifications to the measuring systems are prohibited for safety reasons! i Note Always follow the start-up, operating and programming instructions specified in this manual or in the corresponding encoder documentation. Page 8 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

1.4 Authorised operators The start-up and operation of this device may only be performed by qualified personnel. In the context of the safety-related information in this document, the term "qualified personnel" refers to persons who are authorized to commission, ground and mark circuits, equipment and systems in accordance with recognized safety standards. 1.5 Safety measures at the assembly site Warning Do not carry out welding if the encoder has already been wired up or is switched on! Potential fluctuations can destroy the encoder or impair its operation. Do not touch connector contacts with the hands! Static chargings could destroy electronic components of the encoder. Unused inputs may not be connected (see pin assignment)! i Keep to the supply voltage range Note Ensure that the area around the assembly site is protected from corrosive media (acid, etc.) 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 9 of 18

Parallel - Interface 2 Parallel - Interface 2.1 Description The digital position value will transfer parallelly in the parallel interface. In this case, every signal bit has a separate physical line. In addition to the pure signal-lines, status -lines and control-lines exist, which activate special functions in the encoder or contain its output signals. The transcription of the digital position value into a signal pattern can be realized according to different codes. The most essential codes are explained and itemized in this description. The described signals refer to the at the moment available, maximum performance range. Among other things, the functions implemented in the encoder in actual fact are dependent from the encoder family and the chosen physical interface (number of possible lines, number of pins of the connector). Depending on expansion, some via signal-line accessible functions are also programmable. The represented input and output functions as well represent possibilities. The available functions are dependent on the encoder type. See the programming instructions and manuals of the respective devices to this. 2.1.1 Principle block circuit diagram Push-Pull 7 Tristate Us Logic Data output 7 Page 10 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

2.2 Control inputs V/R Absolute encoder In the case of absolute encoders, the counting direction is defined as increasing with each clockwise rotation (in relation to the shaft). The V/R input can be used to reverse the counting direction while maintaining the same direction of rotation. Linear-absolute position sensor In the case of linear-absolute position sensors, the counting direction is defined as increasing as the position sensor moves towards the end of the rod. The V/R input can be used to reverse the counting direction while maintaining the same direction of rotation. Latch The latch input serves to "freeze" the output data, so that the application electronics reads a static value without edge transitions. Preset The preset input serves to set the position value at the outputs to the programmed preset value. This allows the measuring system to be electronically adjusted. Bus If several devices are operated in the data bus, the bus input can be used to transfer the relevant information of the data output to the bus line. This means, the output drivers are switched active or tristate. PT+/PT- Connection for programming terminal PT100N / PC adapter with PC software (e.g. EPROG) or TA-MINI display. 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 11 of 18

Parallel - Interface 2.3 Control outputs Going up, going down This is a combination of direction indicator and zero-speed relay. The signal bit is set when the position moves in the relevant direction, and deleted once it has remained unchanged for 50 milliseconds. The movement detector has a hysteresis for suppressing vibrations. This is one increment in relation to the resolution of the central wheel for hardware encoders (HE), and 2 mm for position sensors (LA). After a reversal of the rotational direction, a distance corresponding at least to the hysteresis must be traveled before a movement or change of direction is reported. Gone up This signal bit is set when "Going up" is set and deleted when "Going down" is set. The movement detector has a hysteresis for suppressing vibrations. This is one increment in relation to the resolution of the central wheel for hardware encoders (HE), and 2 mm for position sensors (LA). After a reversal of the rotational direction, a distance corresponding at least to the hysteresis must be traveled before a movement or change of direction is reported. Movement This signal bit is set as long as either "Going up" or "Going down" is set. The movement detector has a hysteresis for suppressing vibrations. This is one increment in relation to the resolution of the central wheel for hardware encoders (HE), and 2 mm for position sensors (LA). After a reversal of the rotational direction, a distance corresponding at least to the hysteresis must be traveled before a movement or change of direction is reported. Static and dynamic error (watchdog) As long as the position data can be measured and transferred without error, the signal bit "Static error" is deleted and the signal bit "Dynamic error" supplies a square-wave frequency of 250 Hz. In case of error, the "Static error" is set and the "Dynamic error" stops at an undefined level. Where possible, the dynamic error should be used rather than the static error, as it increases the probability of detecting a faulty program sequence in the device. Even parity, even error parity Uneven parities are obtained by inversion. The error parity corresponds exactly to the normal parity as long as there is no encoder error. In case of error, it is inverted. Its purpose is to save additional transmission of the encoder error. The parity is calculated from the data bits only, i.e. either cams or positions with signs if applicable. All other bits are ignored. Page 12 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

Maximum speed This signal bit is set if the set maximum speed is exceeded. Overspeed This signal bit is set if the set overspeed is exceeded. Limit switch The signal bit of a limit switch is set as long as the position is at or above the switchon point and below the switch-off point. The switch-off point must be higher than the switch-on point. If the opposite case is necessary, the two switching points must be reversed and the signal bit inverted. Logical "0" This signal bit is set to logical "0". 2^0 strobe Siemens specification: with this method, the read-out is synchronized with the pos. and neg. edge of the 2 0 bit. In the case of multi-step codes (binary code), the 2 0 bit changes whenever any other bit is changed. When the 2 0 track changes, the data word is read out after a short delay. Incorrect values (pseudo-tetrades) are not possible. When this function is activated, the 2 0 bit switches from low to high approx. 5 to 10 times. Since the 2 0 bit does not change (either "H" or "L") when the supply voltage is switched on and the shaft stationary, an initial data transfer would not normally be possible before the encoder shaft begins to move. For this reason, the 2 0 bit is allowed to jump four times (high, low, high, low) before switching on the encoder. 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 13 of 18

Parallel - Interface 2.4 Codes The code is a method of forming digital numbers. A code word is a bit pattern which expresses a numerical value. The code describes the assignment of values to code words. In the case of multi-step codes, changing the numerical value by 1 results in a new code word which differs from the previous one in terms of several bits. In single-step codes, only one bit of the code word changes in this case. In decade codes, four bits are grouped to form each decimal number. The following codes are used: Gray As a single-step code, the Gray code can be transmitted parallel without synchronization and can be converted very easily to binary code. To ensure a single-step transition from the lower to the upper range value, it is necessary to select clipped Gray code. In clipped Gray code, the value range used, i.e. the measuring length in increments, is rounded up to the next highest 2 nd power. The value range is then set in the middle of this 2 nd power by adding half the difference between the 2 nd power and the value range before outputting the data. After decoding at the user end, this value must be subtracted again in order to obtain the actual position. Example: in clipped Gray code with 360 increments, half the difference equals (2 9-360)/2=(512-360)/2=76. Clipped code is only possible when the lower range value is 0. Gray code Decimal number Significance 16 8 4 2 1 0 0 0 0 0 0 1 0 0 0 0 1 2 0 0 0 1 1 3 0 0 0 1 0 4 0 0 1 1 0 5 0 0 1 1 1 6 0 0 1 0 1 7 0 0 1 0 0 8 0 1 1 0 0 9 0 1 1 0 1 10 0 1 1 1 1 11 0 1 1 1 0 12 0 1 0 1 0 13 0 1 0 1 1 14 0 1 0 0 1 15 0 1 0 0 0 16 1 1 0 0 0 17 1 1 0 0 1 18 1 1 0 1 1 19 1 1 0 1 0 20 1 1 1 1 0 Page 14 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

Binary The binary code is a multi-step code which allows extremely simple switching circuits for arithmetical operations. Binary code Decimal number Significance 32 16 8 4 2 1 0 0 0 0 0 0 0 1 0 0 0 0 0 1 2 0 0 0 0 1 0 3 0 0 0 0 1 1 4 0 0 0 1 0 0 5 0 0 0 1 0 1 6 0 0 0 1 1 0 7 0 0 0 1 1 1 8 0 0 1 0 0 0 9 0 0 1 0 0 1 10 0 0 1 0 1 0 11 0 0 1 0 1 1 12 0 0 1 1 0 0 13 0 0 1 1 0 1 14 0 0 1 1 1 0 15 0 0 1 1 1 1 16 0 1 0 0 0 0 17 0 1 0 0 0 1 18 0 1 0 0 1 0 19 0 1 0 0 1 1 20 0 1 0 1 0 0 BCD The BCD code is a multi-step decade code which allows extremely simple switching circuits for decimal displays. BCD code (8-4-2-1) Decimal number 2 nd decade 1 st decade 8 4 2 1 8 4 2 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 2 0 0 0 0 0 0 1 0 3 0 0 0 0 0 0 1 1 4 0 0 0 0 0 1 0 0 5 0 0 0 0 0 1 0 1 6 0 0 0 0 0 1 1 0 7 0 0 0 0 0 1 1 1 8 0 0 0 0 1 0 0 0 9 0 0 0 0 1 0 0 1 10 0 0 0 1 0 0 0 0 11 0 0 0 1 0 0 0 1 12 0 0 0 1 0 0 1 0 13 0 0 0 1 0 0 1 1 14 0 0 0 1 0 1 0 0 15 0 0 0 1 0 1 0 1 16 0 0 0 1 0 1 1 0 17 0 0 0 1 0 1 1 1 18 0 0 0 1 1 0 0 0 19 0 0 0 1 1 0 0 1 20 0 0 1 0 0 0 0 0 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 15 of 18

Parallel - Interface Excess-3 Excess-3 is a decade code which, being a single-step code, can be transferred parallel without synchronization and can be converted to BCD code very easily. To ensure a single-step transition from the lower to the upper range value, it is necessary to select clipped Gray excess-3 code. In clipped Gray excess-3 code, the value range used, i.e. the measuring length in increments, is rounded up to the next highest 10 th power. The value range is then set in the middle of this 10 th power by adding half the difference between the 10 th power and the value range before outputting the data. After decoding at the user end, this value must be subtracted again in order to obtain the actual position. Example: In clipped Gray excess-3 code with 720 increments, half the difference equals (10 3-720)/2=(1000-720)/2=140. Clipped code is only possible if the lower range value is 0. Excess-3 code Decimal number 2 nd decade 1 st decade 8 4 2 1 8 4 2 1 0 0 0 1 0 0 0 1 0 1 0 0 1 0 0 1 1 0 2 0 0 1 0 0 1 1 1 3 0 0 1 0 0 1 0 1 4 0 0 1 0 0 1 0 0 5 0 0 1 0 1 1 0 0 6 0 0 1 0 1 1 0 1 7 0 0 1 0 1 1 1 1 8 0 0 1 0 1 1 1 0 9 0 0 1 0 1 0 1 0 10 0 1 1 0 1 0 1 0 11 0 1 1 0 1 1 1 0 12 0 1 1 0 1 1 1 1 13 0 1 1 0 1 1 0 1 14 0 1 1 0 1 1 0 0 15 0 1 1 0 0 1 0 0 16 0 1 1 0 0 1 0 1 17 0 1 1 0 0 1 1 1 18 0 1 1 0 0 1 1 0 19 0 1 1 0 0 0 1 0 20 0 1 1 1 0 0 1 0 Page 16 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016

2.5 Data outputs The data outputs transfer the encoder actual value with the corresponding code to a sequence electronics. If several devices are operated in the data bus, via the tristate input (optionally) the corresponding information of the data output can be transferred to the bus-line. Us corresponds to the encoder voltage supply and is dependent on the encoder type. The output load can be switched dependently by the used logic either to 0 V or to US. Tristate Us 7 max. 35V R L Logic max. 100mA short-circuit proof R L 7 04/05/2016 TR - ECE - TI - GB - 0054-01 Page 17 of 18

Data Transmission / Data Consistency 3 Data Transmission / Data Consistency Short-timely unvalid bit combinations can occur at multi-step codes such as Binary or BCD code. As a rule, the read-in cycle of the evaluation electronic isn't synchronous to the output cycle of the encoder. This indicates that the evaluation electronic can carry out the read operation at the moment of the data freshening of the encoder. At this a bit-combination-change takes place at which is changes more than one bit, the following problem results: The outputs of the encoder have a different condition, therefore the loading- or unloading curves (i.e., no endless steep edges) of the output signal levels are different. Since the switching threshold between "1" and "0" is not in general in the middle of the level range, invalid bit combinations result on a short-term basis. These express in short-term value skips for the customer. How long the unvalid (inconsistent) data be present depends of the cable capacity (quality/length) and also of the input time delay of the digital inputs. Partly, these times absolutely are in the milliseconds area. Remedies: 1. Use of Gray code: Function see chapter "Codes", page 14. 2. Use of software filters in the PLC: - Lock all interrupts - Read inputs and store intermediately - Read inputs again and compare them with the stored value - Are the values identical, takeover, goto :END - Are the values not identical, read inputs again, takeover : END - Unlock interrupts i Note Short waiting times are requiredly possible between the individual read operations. 3. Use of the Latch function: Function see chapter "Control inputs", page 11. i Note Two possible error sources: Level assignment exchanged for latch function and delay time after connecting the latch input is too short. Page 18 of 18 TR - ECE - TI - GB - 0054-01 04/05/2016