TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

Similar documents
TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

DCD ST - SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 500 KHZ WITH 1,000 W

LD 200N100 GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" I ELEKTRONICZNYM PRZEŁĄCZNIKIEM BATERII

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

LD 200N LOAD DUMP GENERATOR WITH CLIPPING-MODULE

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 250 KHZ (500 KHZ) WITH 1,000 W

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.

LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

COMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

Voltage Transient Emission Test

LD 200N. Advanced Test Equipment Rentals ATEC (2832) LOAD DUMP GENERATOR FOR TESTS ACCORDING TO...

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W

NETWAVE SERIES (1-PHASE) PROGRAMOWALNE WIELOFUNKCYJNE ŹRÓDŁO AC/DC

ISO/TS ELECTRICAL DISTURBANCES BY CONDUCTION AND COUPLING PART 4: ELECTRICAL TRANSIENT CONDUCTION ALONG SHIELDED HIGH VOLTAGE SUPPLY LINES ONLY

IEC Electrical fast transient / Burst immunity test

MONITORING DEVICE 4 khz to 400 MHz

Surge Generator for MIL-STD 1275

V1.3. TBLC08 50mH AC-LISN TBLC08

50 μh Line Impedance Stabilisation Network (AC LISN)

EMI Test & Debugging Solution

Wide-band Models from DC to 100 MHz

Application Note MX860803A/MX860903A. cdma Measurement Software. MS8608A/MS8609A Digital Mobile Radio Transmitter Tester

LCR Meter. Product Specification

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

ISOLATED DC/DC CONVERTERS 48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick Converter

Model 310H Fast 800V Pulse Generator

Proper Bias-T Usage to Avoid PPG Damage

Low Frequency Measuring System

MGA Magnetic field system. DC khz

Advanced Test Equipment Rentals ATEC (2832)

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Signal Generator SML

Advanced Test Equipment Rentals ATEC (2832) EMC Calibration ServiCES. Reliable fast worldwide

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

1. General Instructions 2 2. Safety 2 3. Lamp Starting Test Instrument LSTI 5 3

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

EV series of AC voltage amplifiers

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Keysight N9310A RF Signal Generator

Voltage dips short interruptions with PFS and Netwave

World-Class Accuracy & Measurement Range (40 Conventional Models)

AC/DC Current Measurement Systems

Wide-band Models from DC to 100 MHz

Product Introduction. MF2400C Series. Microwave Frequency Counter

Product Introduction. MF2400C Series. Microwave Frequency Counter

NON-ISOLATED DC/DC CONVERTERS 5 Vdc Vdc Input 0.6 Vdc Vdc/40 A Output

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Specification for Conducted Emission Test

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

CAR - TEST - SYSTEM 14

Fast Transient / Burst Simulator

RF Signal Generator SM300

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Fast transient burst simulator

Wide-band Models from DC to 100 MHz

Conducted Spurious Emission into VSWR Measurement Method

Vector Network Analyzers ZVB

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Measuring Power Line Impedance

Compact VNA - TR7530. Extended Specifications EXTEND YOUR REACH TM

Application Note. Calibration of 7000 Series Precision LCR Meters

U3771/3772 Spectrum Analyzers

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A Output

NON-ISOLATED DC/DC CONVERTERS 9.0 Vdc - 18 Vdc Input 5 Vdc - 12 Vdc/1A Output

Part 1: General. Part 3: Mechanical loads Part 4: Climatic loads Part 5: Chemical loads

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

DECLARATION OF CONFORMITY

Transcription:

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO 7637-2 SELON LES NORMES SUIVANTES... > ISO 7637-2:2004 > ISO 7637-2:2011 TEST SET FOR THE MEASUREMENT OF AUTOMOTIVE TRANSIENT EMISSIONS AS PER ISO 7637 The measurement of automotive transient emissions as per ISO 7637-2 requires an electronic switch, a mechancical switch and an artificial network. The electronic switch is a repeatable, calibrated 300 ns semiconductor switch, which is used in most applications, both fast and slow. While, the BS 200N100 can be used up to 1000 V, the standard recommends a mechanical switch for transient emissions over 400 V. The artifical network represents the typical impedance of the wiring harness. The AN 200N100 is designed to meet the requirements of ISO 7637-2, CISPR 25 / ISO 11452-4 and CISPR 16-1-2 and can be switched accordingly. HIGHLIGHTS > BS 200N100 - Electronic switch, 60V DC/100A: DOMAINES D'APPLICATION AUTOMOBILE > - Volt.Drop <1.2V@100A, <0.2V@25A > - Peak voltage max. 1,000V > - Reverse-polarity/short-circuit protected > BSM 200N40 - Mechanical switch, 12/24V DC/40A > AN 200N100 - ISO 7637-2, CISPR 25, CISPR 16-1-2 > - Frequency range 100kHz - 125MHz EM TEST > PAGE 1/5

TRANSIENT EMISSION SET - THE BENEFITS MULTI-PURPOSE AN 200N100 The EM TEST Transient Emission Set consisting of the BS 200N100 electronic switch, the artificial network AN 200N100 and the BSM 200N40 mechanical switch is an easy-to-use, economic and compact solution, fully compliant to ISO 7637-2. Small size of the equipment and short interconnections allow to meet the distances specified by the standard. An optional resistor box RS-Box with shunt resistor is available for transient emission measurements as per ISO 7637-2:2004 and ISO 7637-2:2011. The RS-Box offers the required 40ohm shunt resistor and other demanding shunt resistors values of e.g. 10ohm, 20ohm and 120ohm. THREE-IN-ONE ARTIFICIAL NETWORK The AN 200N100 is the multi-purpose artificial network designed to cover four different test requirements. The various configurations are selected by two switches. One switch is used to configure the AN 200N100 mains input (no capacitor as per ISO 7637-2, 1uF capacitor accross the mains input as per CISPR 25 and ISO 11452-4 or 2uF capacitors in series with a 1ohm resistor as per CISPR 16-1-2). A second switch is used to switch in the internal 50ohm termination resistor as required. The AN 200N100 is fully adapted to the various test requirements and shows the typical impedance characteristics according to the different standards. EM TEST > PAGE 2/5

BS 200N100 - ELECTRONIC SWITCH AN 200N100 - ARTIFICIAL NETWORK SPECIFICATION TECHNICAL DATA Max. 60V DC Max. 100A continuous Peak voltage Max. 1,000V Inrush current Max. 400A for 200ms Voltage drop < 1.2V at 100A < 0.2V at 25A as per ISO 7637-2, CISPR 25, ISO 11452-4 and CISPR 16-1-2, switchable Frequency range 0.1 to 125MHz 1,000V DC/250V AC up to 1kHz Max. 100A AC/DC continuous Inrush current Max. 400A for 200ms Overvoltage protection By varistors Impedance 5uH // 50ohm for details see diagrams on page 2 Overload protection Short-circuit protected Reverse-polarity protected Insertion loss less than 3dB DUT to receiver output Inductance 5uH +/-10% air-core coil Coupling capacitor 0.1uF SWITCH CHARACTERISTICS Switching time 300ns +/- 20% into test load 50uH/0.6ohm On/Off time 10ms to 500ms, continuously selectable via potentiometer Operation mode Indicatied by LED TRIGGER Power supply/dut connection High-current connectors up to 100A 4mm safety lab connectors up to 32A Test output BNC-connection Manual Manual trigger of a single event Auto Automatic trigger with min. 0.1Hz to max. 1Hz repetition, continuously selectable by potentiometer External In CONNECTIONS Dimensions 318 x 126 x 122 mm (L x W x H) Weight approx. 2.8kg Enternal trigger, negative going edge 0V, BNC input 10V MEASUREMENT Voltage monitor BNC output; divider 1:200 +/-5% Trigger Out BNC output; negative going edge 0V Dimensions, weight 90mm x 125mm x 120mm (LxWxH) approx. 1.3kg Supply voltage 24V DC via mains supply adapter EM TEST > PAGE 3/5

BSM 200N40 - MECHANICAL SWITCH OPTIONS SPECIFICATIONS OPTIONAL ACCESSORIES DUT supply 12V/24V CA BS 200N Max. 40A DC continuous, resistive load Calibration load 0.6ohm and 50uH for the verification of the electronic switch characteristic RS-BOX Shunt resistor box with Rs = 10ohm, 20ohm, 40ohm and 120ohm Maximum current Imax 40A @13.5V 20A @27.0V Contact high purity silver contacts, no suppression across relay contact, insulated from the coil circuit SWITCH CHARACTERISTICS Pulse duration > 50ms up to 500ms Pulse repetition 1s to > 10s Operating mode Indicatied by LED TRIGGER Manual Manual trigger of a single event Auto Automatic trigger with min. 0.1Hz to max. 1Hz repetition, continuously selectable by potentiometer External External trigger negative going edge 0V, BNC input Operation Indicated by LED MEASUREMENT Voltage monitor BNC output; divider 1:200 +/-5% CRO trigger BNC output, negative going edge 0V Dimensions, weight 90mm x 105mm x 104mm (LxWxH) approx. 0.8kg Supply voltage 24V DC via mains supply adapter EM TEST > PAGE 4/5

COMPÉTENCE DANS TOUS LES DOMAINES CONTACTEZ DIRECTEMENT EM TEST Suisse Chine AMETEK CTS GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Téléphone +41 (0)61 204 41 11 > Fax +41 (0)61 204 41 00 Internet: www.ametek-cts.com > E-mail: sales.conducted.cts@ametek.com E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Téléphone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: > E-mail: info@emtest.com.cn Allemagne AMETEK CTS Europe GmbH > Customer Care Center EMEA > Lünener Straße 211 > 59174 Kamen > Germany Téléphone +49 (0) 2307 26070-0 > Fax +49 (0) 2307 17050 Internet: www.ametek-cts.com > E-mail: info.cts.de@ametek.com Pologne République de Corée EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Téléphone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr AMETEK CTS Europe GmbH > Biuro w Polsce > ul. Twarda 44 > 00-831 Warsaw > Poland Téléphone +48 (0) 518 643 12 Internet: www.ametek-cts.com > E-mail: Infopolska.cts@ametek.com Singapour USA / Canada Grande Bretagne AMETEK CTS US > 52 Mayfield Ave > Edison > NJ 08837 > USA Téléphone +1 732 417 0501 Internet: www.ametek-cts.com > E-mail: usasales.cts@ametek.com AMETEK GB > 5 Ashville Way > Molly Millars Lane > Wokingham > Berkshire RG41 2 PL > Great Britain Téléphone +44 845 074 0660 Internet: www.ametek-cts.com AMETEK Singapore Pte. Ltd > No. 43 Changi South Avenue 2 > 04-01 Singapore 48164 Internet: www.ametek-cts.com > E-mail: singaporesales.cts@ametek.com Les informations sur l\'étendue de la livraison, la présentation visuelle et les données techniques correspondent à l\'état de développement du produit au moment de la mise en circulation de la fiche technique. Les données techniques sont susceptibles de changement sans préavis. EM TEST > PAGE 5/5