Neural Network Controlled Hybrid Active Power Filter with Distorted Mains for PMSM Drive

Similar documents
Shunt active filter algorithms for a three phase system fed to adjustable speed drive

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Power Quality improvement of a three phase four wire system using UPQC

Fuzzy Logic and PI Controller Based Shunt Active Power Filter For Harmonic Elimination

Performance Analysis Based On Hybrid Active Power Filter for Three Phase Four Wire System

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Literature Review for Shunt Active Power Filters

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Control of Shunt Active Power Filter for Improvement of Power Quality

COMPENSATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

2020 P a g e. Figure.2: Line diagram of series active power filter.

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Power Quality Improvement using Shunt Passive Filter

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Enhancement of Power Quality Using Advanced Series Active Power Filters

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

Enhancement of Power Quality using D-Statcom Fed Induction Motor Drive

Key-Words: - NARX Neural Network; Nonlinear Loads; Shunt Active Power Filter; Instantaneous Reactive Power Algorithm

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Power Quality Improvement using Active shunt Power filter using PI Controller

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

A Time Domain Reference-Algorithm for Shunt Active Power Filters

Review on Shunt Active Power Filter for Three Phase Four Wire System

Harmonic Analysis in Non-linear Load by using Hybrid UPQC

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Improvement of Power Quality Using a Hybrid Interline UPQC

Figure1. Hybrid Filter Configuration

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Analysis & Function of Unified Power Quality Conditioner for Power Quality Improvement of Distributed Network

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

Power Quality Improvement by Using Active Filter with Hysteresis Band Controller

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

World Journal of Engineering Research and Technology WJERT

Unified Power Quality Conditioner Based on Neural-Network Controller for Mitigation of Voltage and Current Source Harmonics

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Implementation of UPQC for Voltage Sag Mitigation

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

ISSN Vol.04,Issue.16, October-2016, Pages:

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

p. 1 p. 6 p. 22 p. 46 p. 58

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Performance Analysis of Shunt Active Power Filter Base On Active Reactive Power Theory

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Implementation of Sparse LMS Control Algorithm in DSTATCOM

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

A Voltage Controlled DSTATCOM using Hybrid Renewable Energy DC Link VSI for Power Quality Improvement

Reactive Power Compensation of LC Coupling Hybrid Active Power Filters by DC Link Voltage Controls

Harmonics Elimination Using Shunt Active Filter

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A Power Control Scheme for UPQC for Power Quality Improvement

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

Mitigation of Voltage Sag, Swell and Load Hamonics by the Combined Opertation of Series APF and Solar System

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

Neuro-Fuzzy Control Technique in Hybrid Power Filter for Power. Quality Improvement in a Three-Phase Three-Wire Power System

Power Quality Analysis in Power System with Non Linear Load

Mitigation of Harmonics in Distribution System Using SAPF

Shunt Active Power Filter for Compensation of System Harmonics

Harmonic Reduction and Power Factor improvement in three phase three wire system by using Passive Filters

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

Power Quality Improvement in Fourteen Bus System using UPQC

Development of Multilevel Inverters for Control Applications

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

B.Tech Academic Projects EEE (Simulation)

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

DYNAMIC VOLTAGE RESTORER FOR EFFICIENT DETECTION AND COMPENSATION OF VOLTAGE SAG USING ANN BASED LMS AS A NEW CONTROL STRATEGY

Real Time Implementation of Shunt Active Power Filter (SAPF) for Harmonic suppression and Power Quality Improvement

Exploration in Power Quality Furtherance on Shunt Active Power Filter

Design of UPQC with constant frequency controlled scheme for removal of Total Harmonic Distortion

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Kalman Filter Based Unified Power Quality Conditioner for Output Regulation

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

ABSTRACT I. INTRODUCTION

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

Transcription:

International Journal of Scientific Research Engineering & Technology (IJSRET), ISSN 2278 882 Volume 4, Issue 2, February 21 126 Neural Network Controlled Hybrid Active Power Filter with Distorted Mains for PMSM Drive Shweta Mishra 1, Satya Prakash Dubey 2 1 (Department of Electrical Engineering, CSVTU University, Bhilai 2 (Department of Electrical Engineering, CSVTU University, Bhilai ABSTRACT The present paper describes dynamic neural network controlled Hybrid Active Power Filter (HAPF) designed for harmonic compensation under variable conditions. A Neural Network based Controller is employed to extract the fundamental component of current from nonsinusoidal and unbalanced source currents of the considered supply system. Hybrid filter utilizing the merits of both shunt passive and active filter for better compensation performance is applied in this work. Simulations are carried out using MATLAB/Simulink to show effectiveness of proposed methodology. The experimental results show excellent behavior of Neural Network Controller and performances of HAPF under various conditions. Keywords - Artificial neural network (ANN) controller, Hybrid active power filter, Permanent magnet synchronous motor (PMSM), Total Harmonic Distortion (THD) I. INTRODUCTION Nowadays the power quality problems are mostly faced by the equipments based on the power electronic devices which are used by the industry. The need of these devices is not only the high quality energy for proper working but also the major cause for decreasing of the power quality. By these conditions of the electric power the customers are increasingly affected. Therefore, a power quality problem exists if any of the voltage, current or frequency deviation from sinusoidal nature occurs. Power quality problems are common in industrial, commercial and utility networks as power electronics appliances are widely used in these fields. These appliances generate harmonics and reactive power. Therefore it is very important to compensate the dominant harmonics and thus Total Harmonic Distortion (THD) below % as specified in IEEE 19 harmonic standard [1]. On the improvement of power quality, utilities and researches all over the world have for decades worked. To the power quality problems there are many sets of conventional solutions which have existed for long time. Nowadays the equipment made up of semiconductor devices is sensitive as well as polluting. Increase in reactive power demand by the equivalent load is due to the non linear devices like power electronic converters which also results in injection of harmonic currents in distribution grid. As it is well known that reactive power demand increases the losses and cause a drop in feeder, which also results in additional losses, voltage waveform distortion and poor power quality. So it is necessary to include some sort of compensation to keep the power quality within limits proposed by standards. The shunt active power filter (APF) is a device that is connected in parallel and cancels the reactive and harmonic currents from a nonlinear load. The resulting total current drawn from ac main is sinusoidal. Ideally, the APF needs to generate the reactive and harmonic current to compensate the nonlinear loads in the line. In an APF depicted, current controlled voltage source inverter is used to generate the compensating current and is injected into utility power source grid. It cancels the harmonic components drawn by nonlinear load and keeps the utility line current sinusoidal. A voltage-source inverter (VSI) having IGBT switches and an energy storage capacitor on dc bus are implemented as a shunt APF. The main aim of the APF is to compensate the harmonics and reactive power [3]. Active power filter is a dynamic and flexible solution for mitigation of harmonic current due to their compact size, no requirement of tuning and stable operation. Active power filter acts as harmonic current source to provide the emphatic result to compensate for harmonic currents as well as reactive power. It has the capability to inject harmonic current into ac system with the same amplitude but in opposite phase of the load [2]. As the HAPF is complex with cost effective parameter control, the hybrid active power filter has been preferable in subject of harmonic solution. HAPF gives the efficacious combination of passive and active filter, which implies the advantages of both and eliminates the short-comes of each one. [4].

International Journal of Scientific Research Engineering & Technology (IJSRET), ISSN 2278 882 Volume 4, Issue 2, February 21 127 In this paper, a new hybrid filter topology is proposed to reduce torque ripples, voltage harmonics in PMSM. The filter topology consists of the IGBT active filter (AF). Power circuit for APF is proposed as an IGBT based three-phase voltage source inverter with DC storage capacitor for the better compensation of non-linear unbalanced /balanced loads. ANN controller is used to generate the fundamental from non-ideal voltage source. The extracted fundamental currents are then subtracted from the source current to evaluate the reference signal i.e. harmonic current. The proposed controller has selflearning with high accuracy and simple architecture and it can be successfully applied for the harmonic filtering under various power system operating conditions. Therefore, this paper presents a hybrid power filter using neural network-controller to control the harmonics under different non-sinusoidal and unbalanced source/load conditions for its performance []. II. PROPOSED TOPOLOGY Three phase three wire hybrid power filter is used; Shunt active power filter is used to generate the compensation current in opposite phase. Power circuit for APF is proposed as an IGBT based three-phase voltage source inverter with DC storage capacitor for the better compensation of loads. In this paper the load is Permanent Magnet Synchronous Motor (PMSM). Active power filter has control scheme; neutral network controller that accounts for reference current generation.ann comprises three adaptive linear neurons to extract the fundamental components of three phase voltages from non-sinusoidal supply. The capacitors are designed to limit the dc voltage ripple to a specified value, typically 1 to 2 %. In this case the capacitor should be designed for worst case. Since the active filter will operate in several modes (balanced or unbalanced load), then the injection of compensation current is done in order to nullify or mitigate the harmonic currents. Injection of this compensation current gives improved power quality. The performance of the active power filters is dependent to a great extent upon the method used for the calculation of reference current. III. CONTROL STRATEGY 1. Neural Network Controller ANNs have the ability to approximate the input output relations with acceptable accuracy regardless of the complexity involved. This, in addition to many other abilities of parallel computation and adaptiveness to external disturbances, has made ANN a promising approximation technique in power system applications. The most commonly used ANN structures for fundamental and/or harmonic extraction are the ADALINE and feed-forward MNN. The focus of this paper is on how to implement the ANN techniques in power system. Power quality enhancement using shunt APF is considered for the effective illustration. The architecture of proposed ADALINE neural network has two layer (input and output) network having n-inputs and a single output [6]. Fig. 1: Proposed topology of Shunt Active Power Filter Fig. 2: Internal block of neural network

Voltage(V) Speed(rad/sec) Torque(Nm) Mag (% of Fundamental) International Journal of Scientific Research Engineering & Technology (IJSRET), ISSN 2278 882 Volume 4, Issue 2, February 21 128 4 3 2 1-1 -2-3 -4 Fig. 3: Input/output relationship of transfer function The basic blocks of this network are input signal delay vector, a purelin transfer function, weight matrix and bias is shown in figure 3. The input output relationship is expressed as: Y= n* i n + b (1) Where b is bias, w is weight, and i is the input to the Neural Network. The input to the network is a time delayed series of the signal whose fundamental component is to be extracted. The length of this delay series is 61, which has been decided considering expected maximum distortion and unbalance in 3-phase input signal [4]. The input of the ANN system is supply voltage and current and the output of the system is APF reference current. The weight adjustment is performed during the training process of the ADALINE using Widrow-Hoff delta rule [6]. The ADALINE is a twolayer neural network consisting of an input layer and output layer. It was invented by Widrow and Hoff when they were trying to implement their famous training algorithm, the least mean square (LMS). It can estimate functions that have linear input output relations, and can work fairly even with some nonlinear real-world applications [6]. IV. RESULT The system was subjected to different load conditions and the Permanent Magnet Synchronous Motor was operated for a reference speed of 2.3rad/sec under the following conditions: Case I: At no load with rated speed. 1 -.1.2.3.4..6.7.8.9.1 4 3 2 1-1 -2-3 -4 - -.1.2.3.4..6.7.8.9.1 1 1 1.3.2.2.1.1. Selected signal: cycles. FFT window (in red): 2 cycles.2.4.6.8.1 Fundamental (Hz) = 7.833, THD= 1.84% 2 4 6 8 1 -.1.2.3.4..6.7.8.9.1 6 4 3 (e) 8 6 2 4 1 2-2 -4-6 -8-1.1.2.3.4..6.7.8.9.1.1.2.3.4..6.7.8.9.1 Fig. 4: Source Voltage, Load Current, Source Current, THD, (e) Motor Torque, Speed response Case II: On Load with rated speed.

Torque(Nm) Torque(Nm) Mag (% of Fundamental) Mag (% of Fundamental) Voltage(V) Voltage(V) International Journal of Scientific Research Engineering & Technology (IJSRET), ISSN 2278 882 Volume 4, Issue 2, February 21 129 1 1 8 8 6 6 4 4 2 2-2 -2-4 -4-6 -6-8 -8-1.1.2.3.4..6.7.8.9.1-1.1.2.3.4..6.7.8.9.1 4 4 3 3 2 2 1 1-1 -2-3 -4-1 -2-3 -4 -.1.2.3.4..6.7.8.9.1 4 3 -.1.2.3.4..6.7.8.9.1 4 3 2 2 1 1-1 Selected signal: cycles. FFT window (in red): 2 cycles -2 1-3 1-4 - -.1.2.3.4..6.7.8.9.1 Time(seec).2.4.6.8.1-1 -2 Selected signal: cycles. FFT window (in red): 2 cycles 1-3 1-4 -.1.2.3.4..6.7.8.9.1 -.2.4.6.8.1 Fundamental (Hz) = 7.862, THD= 3.4% Fundamental (Hz) = 7.86, THD= 3.28%.8.6.4.2 1.8.6.4.2 2 4 6 8 1 1 2 4 6 8 1 1 8 6 4 2-2 -.1.2.3.4..6.7.8.9.1 Fig. : Source Voltage, Load Current, Source Current, THD, (e) Motor Torque, Speed response Case III: Change in load with rated speed. -4.1.2.3.4..6.7.8.9.1 (e)

Mag (% of Fundamental) Voltage(V) Speed(rad/sec) Speed(rad/sec) Torque(Nm) International Journal of Scientific Research Engineering & Technology (IJSRET), ISSN 2278 882 Volume 4, Issue 2, February 21 13 6 1 4 8 6 4 3 2 2 1-2 -4-6 -1.1.2.3.4..6.7.8.9.1 Fig. 6: Source Voltage, Load Current, Source Current, THD, (e) Motor Torque, Speed response -8.1.2.3.4..6.7.8.9.1 6 (e) Case IV: On Load with change in Speed. 1 8 4 3 2 6 4 1 2-2 -4-6 -8-1.1.2.3.4..6.7.8.9.1 4 3 2 1-1 4 3 2 1-1 -2-3 -4 -.1.2.3.4..6.7.8.9.1-2 1-3 1 Selected signal: cycles. FFT window (in red): 2 cycles -4 - -.1.2.3.4..6.7.8.9.1.4.3.2.1.2.4.6.8.1 Fundamental (Hz) = 7.82, THD= 2.22% 2 4 6 8 1.1.2.3.4..6.7.8.9.1 Fig. 7: Source Voltage, Load Current, Source Current, THD, (e) Motor Torque, Speed response V. CONCLUSION In this paper, a new Hybrid Active Power Filter topology has been presented and analyzed. The filter topology combines the compensation characteristics of the shunt active power filter and passive filter. The proposed topology has been shown to be capable of reducing the torque ripple and current harmonics, and providing almost sinusoidal voltage to motor terminals, which was reflected in a smoother line current waveform. REFERENCES [1] Roger C.Dugan, Mark F. McGranaghan, Surya Santoso and H.Wayne Beaty, Electrical power system quality, Mcgraw-Hill. [2] H. Akagi, Trends in active power line conditioners, IEEE Trans. Power Electronics, vol. 9, no. 3, pp. 263-268,May 1994 [3] J. Yongtao Dai, Wenjin Dai, Harmonic and Reactive Power Compensation with Artificial Neural Network Technology, IEEE, 28. [4] Laxmi Devi Sahu, S.P Dubey, ANN based Hybrid Active Power Filter for Harmonics Elimination with Distorted Mains,IJPEDS, Vol. 2, No. 3, pp. 241~248, September 212. [] Ali Ahmed Adam, Kayhan Gulez, Torque ripples and EMI Noise Minimization in PMSM Using Hybrid Filter, SICE annual conference, Sept.17-2,Kagawa University,27.

International Journal of Scientific Research Engineering & Technology (IJSRET), ISSN 2278 882 Volume 4, Issue 2, February 21 131 [6] Mohammed Qasim, Vinod Khadkikar, Application of Artificial Neural Networks for Shunt Active Power Filter Control, IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, VOL. 1, NO. 3, AUGUST 214. [7] A. A. James and E. Rosenfeld, Bernard widrow, in Talking Nets: An Oral History of Neural Networks. Cambridge, MA, USA: MIT Press, ch. 3, pp. 4 69,1998. [8] Satya Prakash Dubey,Pukhraj Singh and H.V.Manjunath, DSP based neural network controlled hybrid active power filter,international Journal of Emerging Electric Power System,Vol.4,No.2,pp.1-16,2. [9] N.Gupta,S.P.Dubey and S.P.Singh, Neural Network-based shunt active filter with direct current control for power quality conditioning, International Journal of Power Electronics, InderScience Publishers Vol.6,No.3,pp.97-62,211. [1] Kayhan Gulez, Ali Ahmed Adam, and Halit Pastaci, Torque Ripple and EMI Noise Minimization in PMSM Using Active Filter Topology and Field- Oriented Control, IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL., NO. 1, JANUARY 28. [11] K. Sangsun, and P. N. Enjeti, "A new hybrid active power filter (APF) topology", IEEE Transactions on Power Electronics, vol.17, no. 1, pp. 48-4,22. [12] Kiran Boby, Prof.Acy M Kottalil, N.P.Ananthamoorthy, Simulation of PMSM Vector Control System with Fuzzy Self-Adjusting PID Controller Using MATLAB, International Journal of Scientific and Research Publications, Volume 3, Issue 3,ISSN 22-313, March 213. [13] H.Akagi, New Trends in active power line conditioning, IEEE Trans. Indu.Applica., vol.32, no.6, Nov./Dec. 1996. [14] Dr.T.Govindaraj, Dhivya.N.M, Simulation Modelling on Artificial Neural Network Based Voltage Source Inverter Fed PMSM, INTERNATIONAL JOURNAL OF INNOVATIVE RESEARCH IN ELECTRICAL, ELECTRONICS, INSTRUMENTATION AND CONTROL ENGINEERING Vol. 2, Issue 1, January 214.